Loading...
HomeMy WebLinkAboutProduct Approval - underlayments Florida Building Code Online Page 1 of 2 File Copy Business & Professional Regulation (� SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications j FBC Staff SCIS Site Map Links Search ba "ONOEALED FAS i ENtRS OH Ai TAOHf,�F?i Product Approval re 0 USER:Public User )",RE THE RESPONSIBILITY OF THE: Product Approval Menu>Product or Application Search>Application List>Application Detail CONTRACTOR OF RECOR[' FL# FL11602-R3 AND Application Type Revision ;;SSE rPLANS AND "' L PROPOSED WORK Code Version Approved ARE SUBJECT TO ANY CORRECTIONS Application Status Approved REQUIRED BY FIELD INSPECTORS THAT Comments F1gp,Y BE NECF� RY IIS ORDEP�TO MAY Archived 0"1PLY.���II' H LL r�RLICAt.E CODES: Product Manufacturer InterWrap,Inc. Address/Phone/Email 32923 Mission Way Mission,NON US 00000 '� ST. (551)574-2939 ,t.LI C mtupas@interwrap.com ;ZFV1F1i LO FO di�'LL!: F r"- Mil Authorized Signature Eduardo Lozano DA i C elozano@interwrap.com PLANS AND PERMIT R1UST RE KEPT C-- J()-- Technical Representative Eduardo Lozano Address/Phone/Email 32923 Mission Way Mission,NON-US 00000 (778)945-2891 elozano@interwrap.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Vii Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA,Inc. Quality Assurance Contract Expiration Date 11/19/2017 Validated By John W. Knezevich, PE -*�, Validation Checklist-Hardcopy Received Certificate of Independence FL11602 R3 COI 2015 01 COI Nieminen.Ddf Referenced Standard and Year(of Standard) Equivalence of Product Standards Certified By Sections from the Code 1507.2.3 1507.2.4 1507.2.8 1507.2.9.2 1507.3.3 1507.4.5.1 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f Fr... 7/25/2017 Florida Building Code Online Page 2 of 2 1507.4.5.2 1507.5.3 1507.7.3 1507.8.3 1507.9.3 1523.6.5.2.1 Product Approval Method Method 2 Option B Date Submitted 05/01/2015 `• Date Validated 05/01/2015 Date Pending FBC Approval 05/10/2015 Date Approved 06/22/2015 Summary of Products FL# Model,Number or Name Description 11602.1 Titanium Roof Underlayments Synthetic sheet-type roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL11602 R3 II 2015 05 FINAL ER INTERWRAP FL11602- Approved for use outside HVHZ:Yes R3.Ddf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-45 Created by Independent Third Party: Yes Other: 1.)The design pressure noted herein pertains to Evaluation Reports use of a specific underlayment system beneath foam-on tile FL11602 R3 AE 2015 05 FINAL ER INTERWRAP F1 11602- sytsems. Refer to ER Section 5.6.3 for details. 2.)Refer to R3.1)df ER Sections 5 and 6 for other Limits of Use. I Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibi lite Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here Product Approval Accepts: Credit Card Safe http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f Fr... 7/25/2017 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 353 CHRISTIAN STREET, UNIT#13 ., TRINITY ERD OXFORD,CT 06478 PHONE:(203) 262-9245 FAX:(203) 262-9243 EVALUATION REPORT Interwrap,Inc. Evaluation Report 111980.11.08-R3 32923 Mission Way FL11602-R3 Mission, BC V2V-6E4 Date of Issuance: 11/03/2008 Canada Revision 3:05/01/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition(2014) Florida Building Code sections noted herein. DESCRIPTION: Titanium'" Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: o%, .,,�_ '' :ems F ,: The facsimile seal appearing was authorized by Robert Nieminen, Robert J.M. Nieminen,P.E. �%s c'` -,U�;n. aL�s�` P.E.on 05/01/2015.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 r"' document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityJERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Titanium— Roof Underlayments, as produced by Interwrap, Inc., have demonstrated compliance with the intent of the following sections of the Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3,1507.3.3,1507.5.3,1507.7.3, Unrolling,Breaking Strength,Pliability, ASTM D226 2006 T1507.8,1507.8.3,1507.9.3 Loss on Heating 1507.2.4,1507.2.8,1507.2.9.2, Thickness,Load-Strain,Adhesion,Thermal ASTM D1970 2009 1507.4.5.1,1507.4.5.2,1507.5.3, Stability,Flexibility,Tear,Permeance 1507.5.3.2,1507.7.3,1507.7.3.2 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 1523.6.5.2.1 Physical Properties(2-ply system) TAS 103 1995 TAS 110 Accelerated Weathering TAS 110 2000 3. REFERENCES: Kati Examination Reference Date ERD(TST6049) Physical Properties 115010.04.09 04/29/2009 ERD(TST6049) Physical Properties 115010.05.10 05/14/2010 ERD(TST6049) Physical Properties 135520.06.11 06/15/2011 ERD(TST6049) Wind Uplift 135520.08.11-1 08/12/2011 ITS(TST1509) Physical Properties 3146738COQ-003A 03/28/2008 ITS(TST1509) Physical Properties 3146738COQ-003B 03/28/2008 ITS(TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS(QUA1673) Quality Control ITS Listings Current ITS(QUA1673) Quality Control Inspection Report 11/19/2014 4. PRODUCT DESCRIPTION: 4.1 Self-Adhering Underlavments: 4.1.1 Titanium— PSU-30 is an unreinforced polymer modified bitumen material adhered to the underside of a polymer- coated,synthetic woven sheet. The underside is backed with a release film. Unit weight 24 lbs/square. 4.2 Mechanically Fastened Underlavments: 4.2.1 Titanium— UDL-25 is a synthetic sheet-type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.5 lbs/square. 4.2.2 Titanium"UDL-25 PLUS is a synthetic sheet-type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.9 lbs/square. 4.2.3 Titanium— UDL-30 is a synthetic sheet-type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.0 lbs/square. 4.2.4 Titanium— UDL-50 is a synthetic sheet-type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.7 lbs/square. 4.2.5 Titanium— UDL-TT is a synthetic sheet-type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.9 lbs/square 4.2.6 Titanium— UDL-TF is a synthetic sheet-type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 2.9 lbs/square. 4.2.7 UDL-TTMC300 is a synthetic sheet-type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 3.2 lbs/square. Exterior Research and Design,I.I.C. Evaluation Report 111980.11.08-R3 Certificate ojAuthori:otion#9503 FL11602-113 Revision 3:05/01/2015 Page 2 of 6 TRINITY ERD 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Titanium" Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: Table 1: Roof Cover Options Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate Shingles Shingles PSU-30 Yes Yes Yes Yes Yes Yes (See 5.5.1) UDL-ZS Yes No No Yes Yes Yes Yes Yes UDL-25 PLUS Yes (base layer in 2- (base layer in 2- Yes Yes Yes ply system) ply system) Yes Yes UDL-30 Yes (base layer in 2- (base layer in 2- Yes Yes Yes ply system) ply system) UDL-50 Yes No No Yes Yes Yes UDL-TT Yes No No Yes Yes Yes UDL-TF Yes No No Yes Yes Yes 'UDL-TTMC300 Yes No No Yes Yes Yes Private Labeled 5.5.1 "Foam-On Tile" is limited to use of 3M'"2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow TILE BOND'"Roof Tile Adhesive (FL717) applications unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. 5.6 Allowable Substrates;Titanium PSU-30: 5.6.1 Direct-Bond to Deck: ➢ New untreated plywood; ➢ Existing untreated plywood,primed as needed with D41 primer to achieve bond. 5.6.2 Bond to Mechanically Attached Base Sheet: ➢ ASTM D226,Type I or II felt. ➢ Titanium UDL-25 PLUS,UDL-30(primed with D41 primer)or UDL-30(inverted). 5.6.3 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012(04-12)does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. 5.6.3.1 Maximum Design Pressure=-45 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)ASTM D41 Underlayment: Titanium PSU-30,self-adhered Exterior Research and Design,LLC. Evaluation Report 111980.11.08-R3 Certificate oJAuthoriration#9503 FL11602-R3 Revision 3:05/01/2015 Page 3 of 6 '\\J TRINITY ERD 5.6.3.2 Maximum Design Pressure=-30 psf*. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Titanium UDL-25 PLUS or UDL-30(inverted) Fasteners: Mechanically attached with 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min.32 ga., 1-5/8"diameter tin caps Spacing: 6-inch o.c.at 4-inch wide side laps and 12-inch o.c.at three(3),equally spaced center rows. Primer: ASTM D41 primer required at all tin-caps. Underlayment: Titanium PSU 30,self-adhered 5.6.3.3 Maximum Design Pressure=-30 psf*. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Titanium UDL-30(printed side up) Fasteners: Mechanically attached with 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min.32 ga., 1-5/8"diameter tin caps. Spacing: 6-inch o.c.at 4-inch wide side laps and 12-inch o.c.at three(3),equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: Titanium PSU 30,self-adhered 5.6.3.4 Maximum Design Pressure=-45 psf*. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Titanium UDL-25 PLUS or UDL-30(inverted) Fasteners: Mechanically attached with 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min.32 ga.,1-5/8"diameter tin caps Spacing: 6-inch o.c.at 4-inch wide side laps and 8-inch o.c.at three(3),equally spaced center rows. Primer: ASTM D41 primer required at all tin-caps. Underlayment: Titanium PSU 30,self-adhered 5.6.3.5 Maximum Design Pressure=-45 psf*. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Titanium UDL-30(printed side up) Fasteners: Mechanically attached with 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min.32 ga., 1-5/8"diameter tin caps. Spacing: 6-inch o.c.at 4-inch wide side laps and 8-inch o.c.at three(3),equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: Titanium PSU 30,self-adhered 5.6.3.6 For mechanically attached base sheet in a 2-ply system,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.1.5.1(a)of FM LPDS 1-29 for Zone 2/3 enhancements 5.7 Exposure Limitations: Titanium UDL-25,UDL-25 PLUS,UDL-30,UDL-50,UDL-TT or UDL-TF shall not be left exposed for longer than 30-days. Titanium PSU-30 shall not be left exposed for longer than 90-days. UDL-TTMC300 not be left exposed for longer than 180-days. Exterior Research and Design,LLC. Evaluation Report 111980.11.08-R3 Certificate of Authorization#9503 FL11602-R3 Revision 3:05/01/2015 Page 4 of 6 P � � TRINITY ERD 6. INSTALLATION: 6.1 Titanium Roof Underlayments shall be installed in accordance with Interwrap published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Titanium—UDL-25,UDL-25 PLUS,UDL-30,UDL-50,UDL-TT,UDL-TF and(Private labeled)UDL-TTMC300: 6.3.1 Install in compliance with manufacturer's published installation instructions and the requirements for ASTM D226,Type I and II underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Fasteners: Mechanical attachment of Titanium UDL-25, UDL-25 PLUS and UDL-30 is limited to ring shank roofing nails with minimum 1-inch diameter plastic caps. Mechanical attachment of UDL-50, UDL-TT, UDL-TF and(Private Labeled) UDL-TTMC300 is limited to ring shank roofing nails with minimum 3/8-inch diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and plates;or plastic cap staples. 6.3.3 Slopes of 4:12 or greater: End(vertical)laps shall be minimum 6-inches and side(horizontal)laps shall be minimum 4-inches. Minimum attachment shall be 12-inches o.c. vertically and 24-inches o.c. horizontally in accordance with the surface markings on the exposed face of the underlayment. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.4 Slopes of 2:12 to less than 4:12: Double layer application; begin by fastening a 25-inch wide strip along the eaves. Place a full-width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.3.3, but maintaining minimum 25-inch side (horizontal)laps,resulting in a double-layer application. 6.4 Titanium—PSU-30: 6.4.1 Install in compliance with manufacturer's published installation instructions and the requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 Direct-to-Deck with Mechanically Fastened Roof Cover: Cut manageable sections and re-roll with the release film side out. Membrane Application: ➢ Peel back release film approximately 1 to 2 feet and align with the lower edge of the roof and set in place, printed side up. ➢ Apply the balance of the membrane to the substrate by removing the film and firmly pressing the membrane into place. ➢ Apply subsequent courses parallel to the eave in a shingle-type,water-shedding manner. ➢ End(vertical)laps shall be minimum 12-inches and side(horizontal)laps shall be minimum 3-inches. ➢ If the membrane becomes misaligned,cut the roll and re-start. ➢ Upon completion,inspect the membrane and repair any defects or fish-mouths. The use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact Interwrap for approved sealant or mastic types. 6.4.3 Direct-to-Deck with Adhesive-Set Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 and Section 5.6.2 herein, using the instructions noted above as a guideline. Wait a minimum of 24 hours prior to loading roof tiles.Tiles shall be staged so as to avoid slippage and/or damage to the roof underlayment. The use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact Interwrap for approved sealant or mastic types. Exterior Research and Design,I.I.C. Evaluation Report 111980.11.08-R3 Certificate of Authorization#9503 FL11602-113 Revision 3:05/01/2015 Page 5 of 6 TRINITY ERS 6.5 Titanium 2-Ply System: 6.5.1 The Titanium System consists of a base layer of Titanium UDL-PLUS or UDL-30 (top-surface primed or inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30,self-adhered. 6.5.2 Non-Tile Applications: Install Titanium UDL-25 PLUS or UDL-30 (top surface primed or inverted) in accordance with Sections 6.3.1 through 6.3.3 followed by Titanium PSU-30 in accordance with Section 6.4. 6.5.3 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing,refer to Interwrap published installation instructions, but not less than FRSA/TRI April 2012(04-12),Table 1. For adhesive-set tile roofing,refer to Section 5.6.3 herein. Wait a minimum of 24 hours prior to loading roof tiles. Tiles shall be staged so as to avoid slippage and/or damage to the roof underlayment. The use of sealant or mastic at tile fastener penetrations is required for all tile roofing installations. Contact Interwrap for approved sealant or mastic types. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA agency for information on production locations covered by F.A.C.Rule 61G20-3 CIA requirements. 9. QUALITY ASSURANCE ENTITY: Intertek Testing Services NA Inc.-ETL/Warnock Hersey—QUA1673;(604)520-3321 -END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 111980.11.08-R3 Certificate of Authorization#9503 FL11602-R3 Revision 3:05/01/2015 Page 6 of 6