Loading...
HomeMy WebLinkAboutProduct Approval File Copy �7e R t• � � A I A ®. A 4 S S' SCIS Home Log In User Registration Hot Topics ' Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map I Links Search dF1oii a ra [ - c ( a' ®' Product Approval )ji� A6E�i fr',o. tH'CH Vfl�i� Itilf�fiif l\ju USER:Public User ARE B1LIT10F il'R Product Approval Menu>Product or Application Search>Application List>Application Detail o F R n 4RV ° FL# FL11651-R2 Application Type Revision � q �+ {� y�5 gg ++�� �* C��9,Rf Code Version 2014 �t3E f✓IrAIVS WIVE! rales�ilU��iS�N �V®f11� Application Status Approved ARE SUBJECT TO ANY CORRECTIONS Comments REQUIRED BY FIELD INSPECTORS THAT �p �g Ap h �g Archived ❑ �a ff BN I�ECESCs R 3:IM ORDEP'TO f Product Manufacturer Gulf Coast Supply&Manufactuting,-LLC:' Address/Phone/Email 4020 S.W.449th Street Horseshoe Beach,FL 32648 (352)498-7852 ray@g ulfcoastsupply.com Authorized Signature Ray Bowen 41, l _ / �U I ray@gulfcoastsupply.com' L fy �; 'rTV�vR7+i` P rDTST7cT N Technical Representative !T, , ivl..TL-17 IAN Address/Phone/Email RLQ V�� ` DATE 7D PER T MUST RE IaPT ON JOB Quality Assurance Representative O?;NO, R sSPEC IONN WILL BE Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Daniel S.Kuhn the Evaluation Report Florida License PE-75519 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/12/2024 Validated By Locke Bowden I] Validation Checklist-Hardcopy Received Certificate of Independence FL11651 R2 COI Cert of Ind Kuhn Eng.pdf FL11651 R2 COI Letter of Name chanoe.ndf Referenced Standard and Year(of Standard) Standard Year FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2004 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/01/2015 Date Validated 07/10/2015 Date Pending FBC Approval 07/18/2015 Date Approved 08/18/2015 Summary of Products Go to Page Page 1/2 FL# Model,Number or Name Description 11651.1 0.032"Aluminum 5V Crimp 0.032"5 V Crimp Aluminum Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 14FL11651 1 R2 0325vCrimp 15- Approved for use outside HVHZ:Yes 32Plvwood NonHVHZ.Ddf Impact Resistant:N/A FL11651 R2 II 14FL11651 1 R2 Metal Roof Panel Detail odf Design Pressure:+N/A/-108.5PSF Verified By: Dan Kuhn,P.E.75519 Other:-108.5 psf @ 12"o.c.Install per manufacturers Created by Independent Third Party:Yes details.Not for use in HVHZ Zones. Evaluation Reports FL11651 R2 AE 14FL11651 1 R2 0325vCrimp 15- 32Plywood NonHVHZ.odf Created by Independent Third Party:Yes 11651.2 0.032"Aluminum Gulf Lok 0.032"Aluminum Gulf Lok 16"Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 14FL11651 2 R2 032GulfLok 16 15- Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf Impact Resistant:N/A FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail pdf Design Pressure:+N/A/-116.OPSF Verified By:Dan Kuhn,P.E.75519 Other:-52.5 psf @ 5 3/16"o.c.fastener spacing. Created by Independent Third Party:Yes -116.0 psf @ 5 3/16"o.c.fastener spacing.Install per Evaluation Reports manufacturers details. Not for use In HVHZ Zones. FL11651 R2 AE 14FL11651 2 R2 032GuifLok 16 15- 32Plywood NonHVHZ.Ddf Created by Independent Third Party:Yes 11651.3 1"24ga.Gulf Snap 1"Gulf Snap 24 Ga. 17"wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail.odf Approved for use outside HVHZ:Yes FL11651 R2 II 14FL11651 3 R2 1 24GulfSnao 17 15- Impact Resistant:N/A 32Plvwood HVHZ..odf Design Pressure:+N/A/--131.OPS Verified By: Dan Kuhn,P.E.75519 Other:-67.3 psf @ 24"o.c.clip spacing.-131 psf @ 6" Created by Independent Third Party:Yes o.c.clip spacing.Install per manufacturers details.For Evaluation Reports use in HVHZ Zones. FL11651 R2 AE 14FL11651 3 R2 1 24GulfSnao 17 15- 32Plywood HVHZ..odf Created by Independent Third Party:Yes 11651.4 1"24ga.VersaLoc 1"VersaLoc 24ga 16.5"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 4 R2 24VersaLoc SR 16.5 15- Approved for use outside HVHZ:Yes 32Plvwood HVHZ..odf Impact Resistant:N/A FL11651 R2 II 14FL11651 4 R2 Metal Roof Panel Detail..odf Design Pressure:+N/A/-138.5PSF Verified By: Dan Kuhn,P.E.75519 Other:-71 psf @ 24"o.c.clip spacing.-138.5 psf @ 6" Created by Independent Third Party:Yes o.c.clip spacing.Install per manufacturers details.For Evaluation Reports use in HVHZ Zones. FL11651 R2 AE 14FL11651 4 R2 24VersaLoc SR 16.5 15- 32Plywood HVHZ..odf Created by Independent Third Party:Yes 11651.5 1"VersaLoc.032"Aluminum 1"VersaLoc.032"Aluminum over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 5 R2 lin 032VersaLoc SR 16 15- Approved for use outside HVHZ:Yes 32Plvwood HVHZ..odf Impact Resistant:N/A FL11651 R2 II 14FL11651 5 R2 Metal Roof Panel Detail odf Design Pressure:+N/A/-101.0PSF Verified By: Dan Kuhn,P.E.75519 Other:-63.3 psf @ 24"o.c.clip spacing.-101.0 psf @ Created by Independent Third Party:Yes 6"o.c.clip spacing.Install per manufacturers details. Evaluation Reports For use in HVHZ Zones. FL11651 R2 AE 14FL11651 5 R2 lin 032VersaLoc SR 16 15- 32Plvwood HVHZ..odf Created by Independent Third Party:Yes J 5 11651.6 1.5"24ga.Gulf Snap 1.5"Gulf Snap 24ga. 16"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 6 R2 1.5 24GulfSnap 16 15- Approved for use outside HVHZ:Yes 32Plywood HVHZ..Ddf Impact Resistant:N/A FL11651 R2 II 14FL11651 6 R2 Metal Roof Panel Detail-odf Design Pressure:+N/A/-116.OPSF Verified By: Dan Kuhn,P.E.75519 Other:-86.0 psf @ 24"o.c.clip spacing.-108.5 psf @ Created by Independent Third Party:Yes 12"o.c.clip spacing.-116.0 psf @ 6"o.c.clip spacing. Evaluation Reports Install per manufacturers detals.For use in HVHZ Zones. FL11651 R2 AE 14FL11651 6 R2 1.5 24GulfSnap 16 15- 32Plvwood HVHZ..odf Created by Independent Third Party:Yes 11651.7 1.5"24ga.VersaLoc 1.5"VersaLoc 24ga. 16"wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 7 R2 1.5 24VersaLoc 16 15- Approved for use outside HVHZ:Yes 32Plywood HVHZ..Edf Impact Resistant:N/A FL11651 R2 1I 14FL11651 7 R2 Metal Roof Panel Detail odf Design Pressure:+N/A/-123.SPSF Verified By: Dan Kuhn,P.E.75519 Other:-59.75 psf @ 24"o.c.clip spacing.-123.5 psf @ Created by Independent Third Party:Yes 12"o.c.clip spacing.Install per manufacturers details. Evaluation Reports For use in HVHZ Zones. FL11651 R2 AE 14FL11651 7 R2 1.5 24VersaLoc 16 15- 32Plywood HVHZ..pdf Created by Independent Third Party:Yes 11651.8 2"24ga.MegaLoc 24 Ga.2"MegaLoc 18"wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 11 14FL11651 8 R2 24MeoaLoc 18 IS- Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf Impact Resistant:N/A FL11651 R2 II 14FL11651 8 R2 Metal Roof Panel Detail odf Design Pressure:+N/A/-108.5PSF Verified By: Dan Kuhn,P.E.75519 Other:-71.0 psf @ 24"o.c.clip spacing.-108.5 psf @ Created by Independent Third Party:Yes 12"o.c.clip spacing.Install per manufacturers details. Evaluation Reports Not for use in HVHZ Zones. FL11651 R2 AE 14FL11651 8 R2 24MeaaLoc 18 15- 32Plywood NonHVHZ.pdf Created by Independent Third Party:Yes 11651.9 24 Ga.Gulf Lok 24 Ga.Gulf Lok 16"Wide over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 14FL11651 9 R2 24GulfLok 16 1S- Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf Impact Resistant:N/A FL11651 R2 II 14FL11651 9 R2 Metal Roof Panel De ail pdf Design Pressure:+N/A/-96.7PSF Verified By: Dan Kuhn,P.E.75519 Other:-81.75 psf @ 10-1/4"o.c.fastener spacing. Created by Independent Third Party:Yes -96.76 psf @ 5-1/8"o.c.fastener spacing.-121.75 psf @ Evaluation Reports 5-1/8"fastener spacing.-161 psf @ 5-1/8"fastener FL11651 R2 AE 14FL11651 9 R2 24GulfLok 16 15- spacing.Install per manufacturers details.Not for use in 32Plywood NonHVHZ pdf HVHZ Zones. Created by Independent Third Party:Yes 11651.10 24 Ga.Gulf Seam 24 Ga.Gulf Seam 16"Wide Roof Panel over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 14FL11651 10 R2 24GulfSeam 16 1x4 15- Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf Impact Resistant:N/A FL11651 R2 II 14FL11651 10 R2 Metal Roof Panel Detail odf Design Pressure:+N/A/-93.5PSF Verified By: Dan Kuhn,P.E.75519 Other:-93.5 psf @ 18"o.c.Install per manufacturers Created by Independent Third Party:Yes details.Not for use in HVHZ Zones. Evaluation Reports FL11651 R2 AE 14FL11651 10 R2 24GulfSeam 16 1x4 15- 32Plywood NonHVHZ.Ddf Created by Independent Third Party:Yes 11651.11 24 Ga.Gulf Seam 24 Ga.Gulf Seam,13/4"Snap Lock, 18"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 14FL11651 11 R2 24GulfSeam 18 IS- Approved for use outside HVHZ:Yes 32Plywood NonHVHZ odf Impact Resistant:N/A FL11651 R2 11 14FL11651 11 R2 Metal Roof Panel Detail pdf Design Pressure:+N/A/-108.5PSF Verified By: Dan Kuhn,P.E.75519 Other:-69.25 psf @ 24"o.c.clip spacing.-108.5 psf @ Created by Independent Third Party:Yes 12"o.c.clip spacing.Install per manufacturers details. Evaluation Reports Not for use in HVHZ FL11651 R2 AE 14FL11651 11 R2 24GulfSeam 18 15- 32Plywood NonHVHZ.odf Created by Independent Third Party:Yes 11651.12 26 Ga.5V Crimp 26 Ga.5V Crimp Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II14FL11651 12 R2 265vCrimo IS- Approved for use outside HVHZ:Yes 32Plywood HVHZ.pdf ov J Impact Resistant:N/A FL11651 R2 II 14FL11651 12 R2 Metal Roof Panel Detail.pdf Design Pressure:+N/A/-156.5PSF Verified By: Dan Kuhn,P.E.75519 Other:-108.5 psf @ 12"o.c.fastener spacing.-156.5 Created by Independent Third Party:Yes psf a 6"o.c.fastener spacing.Install per manufacturers Evaluation Reports details.For use in HVHZ Zones. FL11651 R2 AE 14FL11651 12 R2 265vCrimo 15- 32Plvwood HVHZ.Ddf Created by Independent Third Party:Yes 1 .13 26 Ga.5V Crimp 26 Ga.5V Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 14FL11651 13 R2 265vCrimo 15- Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf Impact Resistant:N/A FL11651 R2 II 14FL11651 13 R2 Metal Roof Panel Detail.ndf Design Pressure:+N/A/-131.PSF Verified By: Dan Kuhn,P.E.75519 Other:-94.25 psf @ 16"o.c.fastener pattern.-131.0 Created by Independent Third Party:Yes psf @ 16"o.c.fastener pattern.Install per Evaluation Reports manufacturers details.Not for use in HVHZ Zones. FL11651 R2 AE 14FL11651 13 R2 265vCrimo 15- 32Plvwood NonHVHZ.Ddf Created by Independent Third Party:Yes 11651.14 26 Ga.5V Crimp 26 Ga.5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 14FL11651 14 R2 265vCrimo 1x4 15- Approved for use outside HVHZ:Yes 32Plvwood NonHVHZ.Ddf impact Resistant:N/A FL116S1 R2 II 14FL11651 14 R2 Metal Roof Panel Detail.odf Design Pressure:+N/A/-156.5PSF Verified By: Dan Kuhn,P.E.75519 Other:-108.5 psf @ 12"o.c.fastener spacing.-156.5 Created by Independent Third Party:Yes psf @ 6"o.c.fastener spacing.Install per manufacturers Evaluation Reports details.For use in HVHZ Zones. FL11651 R2 AE 14FL11651 14 R2 265vCrimo 1x4 15- 32Plvwood NonHVHZ.Ddf Created by Independent Third Party:Yes 11651.15 26 Ga.Gulf Lok 26 Ga.Gulf Lok 16"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 15 R2 26Gulfl-ok 16 15- Approved for use outside HVHZ:Yes 32Plvwood HVHZ.odf Impact Resistant:N/A FL11651 R2 II 14FL11651 15 R2 Metal Roof Panel Detail odf Design Pressure:+N/A/-161.OPSF Verified By: Dan Kuhn,P.E.75519 Other:-63.5 psf @ 5 3/16"o.c.fastener spacing. Created by Independent Third Party:Yes -121.75 psf @ 5 3/16"spacing.-161.0 psf @ 5 3/16" Evaluation Reports o.c.fastener spacing.Install per manufacturers details. FL11651 R2 AE 14FL11651 15 R2 26GulfLok 16 15- For use in HVHZ Zones. 32Plvwood HVHZ.odf Created by Independent Third Party:Yes 11651.16 26 Ga.Gulf Lok 26 Ga.Gulf Lok 16"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 14FL11651 16 R2 26GuifLok 16 15- Approved for use outside HVHZ:Yes 32Plywood NonHVHZ.pdf Impact Resistant:N/A FL11651 R2 II 14FL11651 16 R2 Metal Roof Panel Detail.odf Design Pressure:+N/A/-63.5PSF Verified By: Dan Kuhn,P.E.75519 Other:-63.5 psf @ 5 3/16"o.c.fastener spacing. Created by Independent Third Party:Yes -121.75 psf @ 5 3/16"fastener spacing.-161 psf @ 5 Evaluation Reports 3/16"fastener spacing.Install per manufacturers FL11651 R2 AE 14FL11651 16 R2 26GulfLok 16 15- details.Not for use in HVHZ Zones. 32Plvwood NonHVHZ.odf Created by Independent Third Party:Yes 11651.17 26 Ga.GulfPBR 26 Ga.Gulf PBR Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 17 R2 26GulfPBR 15-32Plywood NonHVHZ.Ddf Approved for use outside HVHZ:Yes FL11651 R2 II 17 R2 Metal Roof Panel Detail pdF Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-154.7PSF Created by Independent Third Party:Yes Other:-59.25 psf @ 24"o.c.fastener pattern.-154.75 Evaluation Reports psf @ 12"o.c.fastener pattern.Install per manufacturer FI-11651 R2 AE 17 R2. 26GulfPBR 15- details.Not for use in HVHZ 32Plvwood NonHVHZ.Ddf Created by Independent Third Party:Yes 11651.18 26 Ga.GulfPBR 26 Ga.GulfPBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 18 R2 26GulfPBR 1x4 15- Approved for use outside HVHZ:Yes 32Plywood HVHZ.odf Impact Resistant:N/A FL11651 R2 II 18 R2 Metal Roof Panel Detail.odf Design Pressure: +N/A/-151.7PSF Verified By: Dan Kuhn,P.E.75519 Other:-100.5 psf @ 24"o.c.fastener spacing.-151.75 Created by Independent Third Party:Yes psf @ 12"fastener spacing.Install per manufacturer's Evaluation Reports details.For use in HVHZ Zones FL11651 R2 AE 14FL11651 18 R2 26GulfPBR 1x4 15- I 32Piywood HVHZ.Ddf Created by Independent Third Party:Yes 11651.19 26 Ga.GulfPBR 26 Ga.GulfPBR over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R2 II 14FL11651 19 R2 26GulfPBR 15- Approved for use outside HVHZ:Yes 32Plvwood HVHZ.Ddf Impact Resistant:N/A FL11651 R2 II 19 R2 Metal Roof Panel Detail.pdf Design Pressure:+N/A/-154.7PSF Verified By: Dan Kuhn,P.E.75519 Other:-60.5 psf @ 24"o.c.fastener spacing.-154.75 Created by Independent Third Party:Yes psf @ 12"o.c,fastener spacing.Install per Evaluation Reports manufacturer's details.For use in HVHZ Zones. FL11651 R2 AE 14FL11651 19 R2 26GulfPBR 15- 32Plvwood HVHZ.pdf Created by Independent Third Party:Yes 11651.20 26 Ga.GulfPBR 26 Ga.GulfPBR over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R2 II 20 R2 26GulfPBR 1x4 15- Approved for use outside HVHZ:Yes 32Plvwood NonHVHZ.pdf Impact Resistant:N/A FL11651 R2 II 20 R2 Metal Roof Panel Detail.Ddf Design Pressure:+N/A/-151.7PSF Verified By: Dan Kuhn,P.E.75519 Other:-94.25 psf @ 24"o.c.fastener spacing.-151.75 Created by Independent Third Party:Yes psf @ 12"fastener spacing.Install per manufacturer's Evaluation Reports details.Not for use in HVHZ Zones FL11651 R2 AE 20 R2 26GuifPBR 1x4 15- 32Plvwood NOnHVHZ.Ddf Created by Independent Third Party:Yes Go to Page 1a 40 Page 1/2 Oack Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: Credit Card Safe oa iNwix T A GuIfCca�t SUPPLY & MANUFACTURING 5VCR ;,,a 26 GA. •IMP ROOF PANEL LORIDA PRODUCT APPROVAL NO. 11651.13 R2 TM Product Evaluation Report GULF COAST SUPPLY& /MANUFACTURING, LLC. 26 Ga. 5V Crimp Roof Panel over 15132"Plywood Florida Product Approval #11651.13 R2 Florida Building Code 2014 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61 G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 rUEI- S,•k'�, OoCE/Vs• Engineer Evaluator: *: No. 75518 ®an Kuhn, P.E. #75519 _ - Florida Evaluation ANE ID: 10743 _— : S -: gyp . TATE OF �Fsi•� OR1DP •���: Validator: Locke Bowden, P.E. #49704 �'A ONAL SO ,0% 9450 Alysbury Place o.6 1I 0 � Montgomery, AL 36117 /3 Zo9$ Contents: Evaluation Report Pages 1 - 5 FL# 11651.13 R2•JUNE 15,2015 ENGINEERING, Vaal . , PRGIDUCT APPROVAL Gulfs SUPPLY & MANUFACTURING 5VCRIMP 26 GA. 5VCRIMP ROOF PANEL OVER • • FLORIDA PRODUCT APPROVAL NO. 11651.13 R2 TM Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage,through fastened roof panel with fasteners in the panel flat over minimum 15/32" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel,ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.4.3. Paint Finish Optional Yield Strength: 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 24" Coverage Rib Height: 38" Major Rib Panel Fastener: #9-15x1.5" with sealing washing in the flat of the panel or approved equal, 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: Minimum 75/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2014. Design Uplift Pressures: Table"A" =Mmum Total Uplifgt Design Pressure =94.05f 131.© psf Fastener Pattern 12"-12" 9.5"-2"-9.5" Fa;te r Pa,tferm Spacing s mmier� v Design Pressure includes a Safety Factor=2.0. FL#11651.13 R2•JUNE 15,2015 ENGINEERING, CoALO ® A DU C ! • ■ oO Gulf SUPPLY & MANUFACTURING 5VCRNMT1 GA..5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD* FLORIDA d PRODUCTAPPROVAL j (•E 11651.13 R2 TM Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-04- Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 117-0053T-05 & 117-0331 T-08 2. Certificate of Independence By Dan Kuhn, P.E. (FL#75519)® Kuhn Engineering, LLC (FBC Organization #ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FL#11651.13 R2•JUNE 15,2015 • • ® ® ® • ENGINEERING,KUHN SUPPLY & MANUFACTURING G61 'CoA FLORIDA PRODUCTAPPROVAL a 5VCRIMP 26 GA. 5VCRIMP ROOF PANEL OVER PLYWOOD* FLORIDA PRODUCT APPROVAL NO. 11651.13 R2 TM Design Procedure: For roofs within the parameters listed on the load table,fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design.The maximum fastener spacing listed herein shall not be exceeded.This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#11651.13 R2•JUNE 15,2015 PRObutT EVAALVATIMWRE`110�01111 , ENGINEERING,KUHN SUPPLY &IENGI N 1E.E R .s L01A T"LE WEC Gull 'Caa� 5VCmKh' IMP IMP ROOF PANEL OVER 15/32" PLYWOOD* 26 GA. 5VCR FLORIDA • , . P • • , APPROVAL • . •, 11651.13 R2 "TM ENGINEER LOAD TABLE: 26 Ga. 5VCrimp Roof Panel over 15/32"Plywood Buildings having¢a5Roof�I 8"'0 Hel4�15 ' 0�" R f Sit lope Z�/1 Z 1 Gable or Hip Roof;Wintl Speeds 1 ZO- a '#¢c s�rsrr�i r - 1?80rnphExposure�� 'MM .-'B dosetll ull1a, based,on Florida Building Code 2014,. 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE (MIN.1/4" SPEED penetration) (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE 1 #915X1 5�' Plywood 16 TYPE 1 16 TYPE1 �16 TYPE 1 16"TYPE 1 16"TYPE 1 116"TYPE 1 1b"T 1'PE 1 ZONE 2 #9-15x1.5" Plywood 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 ZONE3 F #915x15- , 11God 10'TYPE16 TYPE1��6`}TYP,E^1 16"TYPE 1 96"TYPE 1 16"TYPE 2 1'6"TYPE 2 1.)PANEL DESCRIPTION:5V CRIMP, MIN. 26 GA.,GRADE 80,24"COVERAGE. 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER W/MIN. A" PENETRATION. 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:-94.25 PSF® 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN,-131.0 PSF®16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.)PLYWOOD DECKING:MIN.1-/32"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2014 ZONE 2 HIP ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or r ZONE 3 �l a 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be ------------�' less than either 4%of the minimum width of the building or 3 feet. `�� t RIDGE ; TYPE 1 FASTENER PATTERN --- ` (1) #9-15 x 1-1/2" HWH w/Sealing Washer n�, E1 \�� �� 12111211- ---------� EavE At Panel Lap ZONE 2 GABLE ROOF ."^\ lr�--5a TYPE 2 FASTENER PATTERN RIDGE (1) #9-15 x 1-1/2" HWH w/Sealing Washer +--------------------- a I ZONE 1 I I ZONE 3 EAVE FL#11651.13 R2•JUNE 15,2015 ® ® VAILUAVON ® .