Loading...
HomeMy WebLinkAboutCompaction testSoil Nuclear Gauge Client: Project: G °r�• Report Date: 3/20/2017 GHO Homes Corporation 15-0338.00 �y,RNA�Dap" Test Method: ASTM D 6938 590 NW Mercantile Place Meadowood Golf & Country Club Port St. Lucie Port St. Lucie, FL 34986 Fort Pierce, Florida FBPE CA # 4930 521 NW Enterprise Drive Port St. Lucie, FL 34986 Phone: 772-924-35751 Fax: 772-924-3580 Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 34 3/17/17 P-3 N/A 11.2 113.3 9.9 110.9 12 98 95 / 105 Pass 35 3/17/17 P-3 N/A 11.2 113.3 8.3 113.9 12 101 95 / 105 Pass 36 3/17/17 P-3 N/A 11.2 113.3 9.2 113.0 12 100 95 / 105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN Field Technician 34 Below Slab Grade: Lot 269, foundation pad, southeast corner 0-1 Troxler 3430 25093 Smith, Johnnie 35 Below Slab Grade: Lot 269, foundation pad, northwest corner 0-1 Troxler 3430 25093 Smith, Johnnie 36 Below Slab Grade: Lot 269, foundation pad, center 0-1 Troxler 3430 25093 Smith, Johnnie Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as 1"Backscafter". Gauge calibration data on file with the testing agency. 3 / o o -s-,-:-?74 %sine Z)f--, �P+ P-0 APR 12 2017 PERMITTING St. Lucie County, FL Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. [IW19 e ,moo Q�.•�\G " SF•.F.p'�s Dnald W. Mole P.E.: STATE �'F • 44/ oR.6fe,§sional Eng�epfAV675 •,•°oPsaeQf�lAW 0�v�e Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. THIS AGREEMENT PROVIDES FOR HomeTeam PEST o E F E N S E' 12 APR ��� RETREATMENT OF A STRUCTURE AND THE REPAIR OF DAMAGES RElero,7- "47" 1'70/ — OS-20 P1=�'• MITTIMC- CAUSED BY WOOD DESTROYING ORGANISMS WITHIN THE LIMITS A ^niN` St. Lucie County, FL STATED IN THIS AGREEMENT. AGREEMENT FOR THE INSTALLATION AND MONITORING OF THE SENTRICONO COLONY ELIMINATION SYSTEM FOR NEW CONSTRUCTION Section I. GENERAL INFORMATION. Name: G,/O Billing Address: Service Address: 3100 Bent Pine Dr City: City: Fort Pierce State: Zip Code: State: FL Zip Code: 34951 Home Phone: Location of Treatment Sticker: Panel Work Phone: Linear Footage of Structure(s): 210 Treatment Type: ❑ Corrective m Preventive Section II. SERVICE COMMITMENT. HomeTeam Pest Defense, Inc. (the "Company") will, in compliance with applicable federal, state and local laws, rules and regulations: A. Install the Sentricon termite bait stations (the "Stations") in the soil around the perimeter of the structure(s) (see attached graph) located at the Service Address above (the "Strucmre(s)") for the installation fee of $ pald 1)y 1)Ullder B. Monitor the Stations in accordance with the label directions for a period of twelve (12) months immediately following installation of the Stations for an annual fee of $ Zero C. Total cost for the first year of Installation and Monitoring $ Zero , D. The Annual Renewal Fee after the first year $ 300.00 E. During the monitoring period, add and remove Recruit® termite bait from the Stations as appropriate; F. During the monitoring period, maintain all Stations in serviceable condition; Section III. CUSTOMER UNDERSTANDING OF PERFORMANCE OF SENTRICON SYSTEM. Customer understands that: A. The Sentricon System involves installation and monitoring, colony elimination with Recruit termite bait, and subsequent monitoring for continuous protection from new termite colonies; B. Intervals of from a few weeks to more than a year should be expected between: i. Installation of the Sentricon stations and sufficient termite activity to allow the addition of Recruit termite bait; and ii. Addition of Recruit termite bait. C. During the interval(s) between installation of the Stations and complete elimination of existing termite colonies, termite feeding within the Structures, possibly involving additional structural damage, may occur. Additional services such as spot applications of conventional tenmiticides are available to combat termite activity on a localized, short-term basis if desired, but are not needed for and will not contribute to termite colony elimination. D. The active ingredient in the Sentricon System is an insect growth regulator (Recruit) that prevents worker termites from molting. (Molting is critical to colony survival.) E. In tests that it conducted on Recruit, Dow AgroSciences LLC, the manufacturer of Recruit, observed evidence of very low levels of mammalian toxicity only at very high levels of exposure. F. Treatment is provided against the attack of subterranean termites (Reticulitermes spit., Heterolenmes spp. and Coptolermes spp. (Formosan). This Agreement does not provide for the treatment of any other pests, plant, animal or organism other than such termites. The Company has not inspected or treated the structure(s) for health -related molds or fungi. By law, the Company is not qualified, authorized or licensed to inspect for health -related molds or fungi. G. The Company makes no representations regarding the exact location or number of any existing termite colonies. Section IV. DOW AGROSCIENCES LLC OWNERSHIP OF SENTRICON SYSTEM COMPONENTS. Customer also understands that: A. The Sentricon System and all of the components of the Sentricon System ("Components") have been designed by Dow AgroSciences LLC. The Components are and will remain the property of Dow AgroSciences LLC. Customer has no rights with respect to any of the Components, other than the right to their use as installed by the Company on the Customer's premises under this Agreement. B. On expiration or termination of this Agreement, the Company and Dow AgroSciences LLC or their respective representatives are authorized by Customer to retrieve from Customer's premises the Stations and other Components for appropriate disposition. In addition, if the Company, for whatever reason, ceases to represent or to be authorized to represent the Sentricon System, i. The Company will: a. So notify Customer; It. Offer Customer the alternatives of either using a different form of termite protection or terminating this Agreement; C. Credit the Customer for services paid for but not yet received, if appropriate; d. Refund to the Customer an amount equal to the fee paid for services not yet received if Customer elects to discontinue the relationship, or if the Company cannot offer an effective alternative form of termite protection; and C. Retrieve, or allow Dow AgroSciences LLC or its representatives reasonable access to the premises for the retrieval of the Components; and ii. Customer will: a. Grant the Company and Dow AgroSciences LLC or their respective representatives reasonable access to the premises for the retrieval of the Components; and It. Either agree with the Company on the use of an alternative form of termite control or terminate this Agreement. PAYMENT METHOD. ❑ Cash ❑ Check ❑ Credit Card If paying by credit card or recurring debit from your bank account, please complete the attached Authorization for Pre -Arranged Payments. This Agreement contains certain limitations, conditions and exclusions on the Company's obligations. Please read the entire Agreement before signing. In consideration for the Company performing the services specified above and subject to the terms and conditions of this Agreement, Customer agrees to make the payments indicated above. Customer acknowledges receipt of a signed copy of this Agreement. This Agreement is not binding on the Company until signed by an authorized manager or executive officer of the Company. CUSTOMER: HOMErAM PE,%T DEFENSE, INC. Signature: Signature: C ' Printed Name: Printed Name: Ken Colabella Effective Date: 4/4/2017 I RIGHT TO CANCEL: YOU, THE CUSTOMER, MAY CANCEL THIS TRANSACTIONAT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAYAFTER THE DATE OF THIS TRANSACTION. SEETHE ATTACHED NOTICE OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. I THE REMOVAL OF THE BAIT OR BAITING SYSTEM MAY RESULT IN A LACK OF TERMITE PROTECTION Sentricon, Recruit and Baimbe are registered trademarks of Dow AgroSciences LLC. 0 HomeTeam Pest Defense, Inc. 2013 (52986 5YR) 3/13