HomeMy WebLinkAboutCompaction testSoil Nuclear Gauge
Client:
Project:
G
°r�•
Report Date: 3/20/2017
GHO Homes Corporation
15-0338.00
�y,RNA�Dap"
Test Method: ASTM D 6938
590 NW Mercantile Place
Meadowood Golf & Country Club
Port St. Lucie
Port St. Lucie, FL 34986
Fort Pierce, Florida
FBPE CA # 4930
521 NW Enterprise Drive
Port St. Lucie, FL 34986
Phone: 772-924-35751 Fax: 772-924-3580
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
N
Maximum
Dry Density
(pcf)
In Place
Moisture
N
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
N
Remark
34
3/17/17
P-3
N/A
11.2
113.3
9.9
110.9
12
98
95 / 105
Pass
35
3/17/17
P-3
N/A
11.2
113.3
8.3
113.9
12
101
95 / 105
Pass
36
3/17/17
P-3
N/A
11.2
113.3
9.2
113.0
12
100
95 / 105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN
Field Technician
34
Below Slab Grade: Lot 269, foundation pad, southeast corner
0-1
Troxler 3430 25093
Smith, Johnnie
35
Below Slab Grade: Lot 269, foundation pad, northwest corner
0-1
Troxler 3430 25093
Smith, Johnnie
36
Below Slab Grade: Lot 269, foundation pad, center
0-1
Troxler 3430 25093
Smith, Johnnie
Remarks
Comments
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
1"Backscafter". Gauge calibration data on file with the testing agency.
3 / o o -s-,-:-?74 %sine Z)f--,
�P+ P-0
APR 12 2017
PERMITTING
St. Lucie County, FL
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
[IW19
e
,moo Q�.•�\G " SF•.F.p'�s
Dnald W. Mole P.E.:
STATE �'F • 44/
oR.6fe,§sional Eng�epfAV675
•,•°oPsaeQf�lAW 0�v�e
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
THIS AGREEMENT PROVIDES FOR
HomeTeam
PEST o E F E N S E'
12
APR ���
RETREATMENT OF A STRUCTURE
AND THE REPAIR OF DAMAGES
RElero,7- "47" 1'70/ — OS-20
P1=�'• MITTIMC-
CAUSED BY WOOD DESTROYING
ORGANISMS WITHIN THE LIMITS
A ^niN`
St. Lucie County, FL
STATED IN THIS AGREEMENT.
AGREEMENT FOR THE INSTALLATION AND MONITORING
OF THE SENTRICONO COLONY ELIMINATION
SYSTEM FOR NEW CONSTRUCTION
Section I. GENERAL INFORMATION.
Name: G,/O
Billing Address:
Service Address: 3100 Bent Pine Dr
City:
City: Fort Pierce
State:
Zip Code:
State: FL Zip Code: 34951
Home Phone:
Location of Treatment Sticker: Panel
Work Phone:
Linear Footage of Structure(s): 210
Treatment Type: ❑ Corrective m Preventive
Section II. SERVICE COMMITMENT.
HomeTeam Pest Defense, Inc. (the "Company") will, in compliance with applicable federal, state and local laws, rules and regulations:
A. Install the Sentricon termite bait stations (the "Stations") in the soil around the perimeter of the structure(s) (see attached graph) located at the Service Address
above (the "Strucmre(s)") for the installation fee of $ pald 1)y 1)Ullder
B. Monitor the Stations in accordance with the label directions for a period of twelve (12) months immediately following installation of the Stations for an annual
fee of $ Zero
C. Total cost for the first year of Installation and Monitoring $ Zero ,
D. The Annual Renewal Fee after the first year $ 300.00
E. During the monitoring period, add and remove Recruit® termite bait from the Stations as appropriate;
F. During the monitoring period, maintain all Stations in serviceable condition;
Section III. CUSTOMER UNDERSTANDING OF PERFORMANCE OF SENTRICON SYSTEM.
Customer understands that:
A. The Sentricon System involves installation and monitoring, colony elimination with Recruit termite bait, and subsequent monitoring for continuous protection
from new termite colonies;
B. Intervals of from a few weeks to more than a year should be expected between:
i. Installation of the Sentricon stations and sufficient termite activity to allow the addition of Recruit termite bait; and
ii. Addition of Recruit termite bait.
C. During the interval(s) between installation of the Stations and complete elimination of existing termite colonies, termite feeding within the Structures, possibly
involving additional structural damage, may occur. Additional services such as spot applications of conventional tenmiticides are available to combat termite
activity on a localized, short-term basis if desired, but are not needed for and will not contribute to termite colony elimination.
D. The active ingredient in the Sentricon System is an insect growth regulator (Recruit) that prevents worker termites from molting. (Molting is critical to colony
survival.)
E. In tests that it conducted on Recruit, Dow AgroSciences LLC, the manufacturer of Recruit, observed evidence of very low levels of mammalian toxicity only at
very high levels of exposure.
F. Treatment is provided against the attack of subterranean termites (Reticulitermes spit., Heterolenmes spp. and Coptolermes spp. (Formosan). This Agreement
does not provide for the treatment of any other pests, plant, animal or organism other than such termites. The Company has not inspected or treated the
structure(s) for health -related molds or fungi. By law, the Company is not qualified, authorized or licensed to inspect for health -related molds or fungi.
G. The Company makes no representations regarding the exact location or number of any existing termite colonies.
Section IV. DOW AGROSCIENCES LLC OWNERSHIP OF SENTRICON SYSTEM COMPONENTS.
Customer also understands that:
A. The Sentricon System and all of the components of the Sentricon System ("Components") have been designed by Dow AgroSciences LLC. The Components
are and will remain the property of Dow AgroSciences LLC. Customer has no rights with respect to any of the Components, other than the right to their use as
installed by the Company on the Customer's premises under this Agreement.
B. On expiration or termination of this Agreement, the Company and Dow AgroSciences LLC or their respective representatives are authorized by Customer to
retrieve from Customer's premises the Stations and other Components for appropriate disposition. In addition, if the Company, for whatever reason, ceases to
represent or to be authorized to represent the Sentricon System,
i. The Company will:
a. So notify Customer;
It. Offer Customer the alternatives of either using a different form of termite protection or terminating this Agreement;
C. Credit the Customer for services paid for but not yet received, if appropriate;
d. Refund to the Customer an amount equal to the fee paid for services not yet received if Customer elects to discontinue the relationship, or if the
Company cannot offer an effective alternative form of termite protection; and
C. Retrieve, or allow Dow AgroSciences LLC or its representatives reasonable access to the premises for the retrieval of the Components; and
ii. Customer will:
a. Grant the Company and Dow AgroSciences LLC or their respective representatives reasonable access to the premises for the retrieval of the
Components; and
It. Either agree with the Company on the use of an alternative form of termite control or terminate this Agreement.
PAYMENT METHOD. ❑ Cash ❑ Check ❑ Credit Card
If paying by credit card or recurring debit from your bank account, please complete the attached Authorization for Pre -Arranged Payments.
This Agreement contains certain limitations, conditions and exclusions on the Company's obligations. Please read the entire Agreement before signing.
In consideration for the Company performing the services specified above and subject to the terms and conditions of this Agreement, Customer agrees to make the
payments indicated above. Customer acknowledges receipt of a signed copy of this Agreement. This Agreement is not binding on the Company until signed by an
authorized manager or executive officer of the Company.
CUSTOMER: HOMErAM
PE,%T DEFENSE, INC.
Signature: Signature:
C '
Printed Name: Printed Name: Ken Colabella
Effective Date: 4/4/2017
I
RIGHT TO CANCEL: YOU, THE CUSTOMER, MAY CANCEL THIS TRANSACTIONAT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS
DAYAFTER THE DATE OF THIS TRANSACTION. SEETHE ATTACHED NOTICE OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT.
I THE REMOVAL OF THE BAIT OR BAITING SYSTEM MAY RESULT IN A LACK OF TERMITE PROTECTION
Sentricon, Recruit and Baimbe are registered trademarks of Dow AgroSciences LLC.
0 HomeTeam Pest Defense, Inc. 2013 (52986 5YR) 3/13