FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: AVALON_eMEDI_MEADOWOOD_LOT 269 Builder Name: GHO Homes
Street: 3100 Bent Pine Drive Permit Office:
City,State,Zip: Ft Pierce,FL,34951 Permit Number:
Owner. GHO Homes Jurisdiction:
Design Location: FL,Fort Pierce County:: Indian River(Florida Climate Zone 2)
i:o 1
1. New construction or existing New(From Plans) 9. Wall Types(2255.6 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1977.10 ft2
b.Frame-Steel,Adjacent R=11.0 278.44 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? -No 10.Ceiling Types (2475.5 sgft.) Insulation Area
a.Under Attic(Vented) R=30.0 2284.00 ft2
6. Conditioned floor area above grade(ft2) 2284 b.Knee Wall(Vented) R=19.0 191.50 ft2
Conditioned floor area below grade(ft2) 0 11 c.N/A
R R ft2
7. Windows(399.7 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 489.8,
a. U-Factor. Dbl,U=0.49 196.00 ft2
SHGC: SHGC=0.24
Y__-- b. U-Factor. Dbl,U=0.53 96.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.25 a.Central Unit 42.0 SEER:16.00
c. U-Factor. Dbl,U=0.46 70.17 ft2
SHGC: SHGC=0.26 13.Heating systems kBtu/hr Efficiency'
d. U-Factor: other(see details) 37.58 ft2 a.Electric Strip Heat 42.0 COP:1.00'i
SHGC: other(see details)
Area Weighted Average Overhang Depth: 7.073 ft.
Area Weighted Average SHGC: 0.240 14.Hot water systems
8. Floor Types (2284.0 sgft.) Insulation Area a.Electric Cap:50 gallons
a.Slab-On-Grade-Grade Edge Insulation R=0.0 2284.00 ft2 b. Conservation features EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.175 Total Proposed Modified Loads: 75.41 PASS
Total Baseline Loads: 76.21
I hereby certify that the plans and specifications covered by Review of the plans and OWtHE ST'4T�I
this calculation are in compliance with the Florida Energy specifications covered by this p
Code. calculation indicates compliance
with the Florida Energy Code. .`.•`+'';
PREPARED BY: Ryan McCrackenj0111 Before construction Is completed
DATE: 1/17/2017 this building will be inspected for
compliance with Section 553.908 * a
Florida Statutes.
I hereby certify thaQhisbuiin ned,is in compliance with the Florida En GpD WEOWNER/AGENT BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report In accordance with I111402.4.1.2. II
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors;
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 Qn for whole house.
1/17/2017 8:26 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software j C of 5
FILE
C
I
I
FORM R405-2014
PROJECT
Title: AVALON_eMEDI_MEADOW Bedrooms: 3 Address Type: Street Address
y Building Type: User Conditioned Area: 2284 Lot# 269
Owner. GHO Homes Total Stories: 1 Block/SubDivision: Meadowood
#of Units: 1 Worst Case: No PlatBook:
Builder Name: GHO Homes Rotate Angle: 135 Street: 3100 Bent Pine Drive
Permit Office: Cross Ventilation: County: Indian River
Jurisdiction: Whole House Fan: City,State,Zip: Ft Pierce,
Famlly Type: Single-family FL, 34951
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Blockl 2284 21317.5
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 2284 21317.5 Yes 4 3 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 241.67 ft 0 2284 ft2 .__ 1 0 „0
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Barrel file 2554 ft' 0 ft2 Medium 0.75 No 0.9 No 0 26.6
`/ ATTIC
V # Type Ventilation Vent Ratio(1 In) Area RBS IRCC
1 Full attic Vented 150 2284 ft= N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 2284 ftz 0.11 Wood
2 Knee Wall(Vented) Main 19 Batt 191.5 ft2 0.11 Wood
1/17/2017 8:26 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 12 of 5
J
I
FORM R405 2014
WALLS
r Adjacent Space Cavity Width Height Sheathing Framing Solar Below
# Omt-- To Wall Twe1 S=>NW Garage Frame-Steel Main 11 18 0 9 4 168.0 ft2 0.23 0.01 0
_2 W=>NE Garage Frame-Steel Main 11 7 10 9 4 73.1 ft2 0.23 0.01 0
_3 S=>NW Garage Frame-Steel Main 11 4 9 4 37.3 ft2 0.23 0.01 0
_4 S=>NW Exterior Concrete Block-Int Insul Main 4.1 11 9 9 4 109.7 ft2 0 0 0.600000 0
_5 SE=>W Exterior Concrete Block-Int Insul Main 4.1 3 0 9 4 28.0 ft2 0 0 0.600000 0
6 E=>SW Exterior Concrete Block-Int Insul Main 4.1 3 7 9 4 33.4 ft2 0 0 0.600000 0
7 S=>NW Exterior Concrete Block-Int Insul Main 4.1 6 6 9 4 60.7 ft2 0 0 0.600000 0
8 W=>NE Exterior Concrete Block-Int Insul Main 4.1 7 8 9 4 71.6 ft2 0 0 0.600000 0
9 S=>NW Exterior Concrete Block-Int Insul Main 4.1 17 9 4 158.7 ft2 0 0 0.600000 0
10 E=>SW Exterior Concrete Block-Int Insul Main 4.1 46 4 9 4 432A ft2 0 0 0.600000 ! 0
_11 N=>SE Exterior Concrete Block-Int Insul Main 4.1 16 9 4 149.3 ft2 0 0 0.600000 0
12 W=>NE Exterior Concrete Block-Int Insul Main 4.1 11 6 9 4 107.3 ft2 0 0 0.600000 0
13 N=>SE Exterior Concrete Block-Int Insul Main 4.1 13 2 9 4 122.9 ft2 0 0 0.600000 0
14 NE=>S Exterior Concrete Block-Int Insul Main 4.1 3 6 9 4 32.7 ft2 0 0 0.600000 0
15 E=>SW Exterior Concrete Block-Int Insul Main 4.1 1 5 9 4 13.2 ft2 0 0 0.600000 0
_16 NE=>S Exterior Concrete Block-Int Insul Main 4.1 5 2 9 4 48.2 ft2 0 0 0.600000 0
17 N=>SE Exterior Concrete Block-Int Insul Main 4.1 6 11 9 4 64.6 ft2 0 0 0.600000 0
18 E=>SW Exterior Concrete Block-Int Insul Main 4.1 4 9 4 37.3 ft2 0 0 0.600000 0
_19 N=>SE Exterior Concrete Block-Int Insul Main 4.1 17 10 9 4 166A ft2 0 0 0.600000 0
_20 W=>NE Exterior Concrete Block-Int Insul Main 4.1 36 6 9 4 340.7 ft2 0 0 0.600000 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 S=>NW Wood Main None .14 2 8 8 21.3 ft2
2 S=>NW Insulated Main None .14 3 8 24 ft=
3 W=>NE Insulated Main None .14 1 1.2 8 8.8 1112
4 NE=>S Insulated Main None .14 1 1.2 8 8.8 ft2
5 E=>SW Insulated Main None .14 1 1.2 8 8.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 135 degrees).
/ Wall Overhang
1/ # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 S=>NW 4 Metal Low-E Double Yes 0.49 0.24 30.0 ft2 1 ft 0 in 4 ft 1 In Drapes/blinds None
2 S=>NW 4 Metal Low-E Double Yes OA6 0.26 12.0 ft2 1 ft 0 in 1 fill in Drapes/blinds None
3 SE=>W 5 Metal Low-E Double Yes 0.49 0.24 10.0 ft2 6 ft 3 in 7 ft 2 In Drapes/blinds None
4 SE=>W 5 Metal Low-E Double Yes 0.46 0.26 3.0 ft2 6 ft 3 In 5 ft 2 in Drapes/blinds None
5 S=>NW 7 Metal Low-E Double Yes 0.46 0.26 8.0 ft2 8 ft 6 in 5 ft 10 in Drapes/blinds None
6 S=>NW 7 Metal Low-E Double Yes 0.46 0.26 8.7 ft2 8 ft 6 in 2 ft 7 in Drapes/blinds None
7 S=>NW 9 Metal Low-E Double Yes 0.49 0.24 20.0 ft2 1 ft 0 in 3 ft 8 in Drapes/blinds, None
8 E=>SW 10 Metal Low-E Double Yes 0.46 0.26 10.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
9 E=>SW 10 Metal Low-E Double Yes 0.49 0.24 6.0 ft2 1 ft 0 In 1 ft 0 in Drapes/blinds No
10 N=>SE 11 Metal Low-E Double Yes 0.49 0.24 36.0 ft2 1 ft 0 in 3 ft 2 In Drapes/blinds None
1/17/2017 8:26 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
i
1
FORM R405-2014
WINDOWS
Orientation shown Is the entered orientation => changed to As Built rotated 135 degrees).
/ Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
11 W=>NE 12 Metal Low-E Double Yes 0.25 0.18 12.5 ft2 26 ft 2 in 3 ft 4 In Drapes/blinds None
12 N=>SE 13 Metal Low-E Double Yes 0.53 0.25 96.0 ft2 11 ft 6 in 3 ft 1 in Drapes/blinds None
® 13 N=>SE 13 Metal Low-E Double Yes 0.46 0.26 18.0 1`12 11 ft 6 In 1 ft 1 In Drapes/blinds None
14 NE=>S 14 Metal Low-E Double Yes 0.25 0.18 12.5 ftz 14 ft 21n 3 ft 4 In Drapes/blinds None
• 15 NE=>S 16 Metal Low-E Double Yes 0.49 0.24 18.0 ft2 7 ft 9 in 3 ft 2 in Drapes/blinds None
16 NE=>S 16 Metal Low-E Double Yes OA6 0.26 4.5 ft2 7 ft 9 in 1 ft 1 in Drapes/blinds None
17 N=>SE 17 Metal Low-E Double Yes 0.49 0.24 24.0 ft2 4 ft 0 In 3 It 2 In Drapes/blinds None
18 N=>SE 17 Metal Low-E Double Yes 0.46 0.26 6.0 ft2 4 ft 0 In 1 ft 1 in Drapes/blinds None
19 E=>SW 18 Metal Low-E Double Yes 0.25 0.18 12.6 ft2 26 ft 2 in 3 ft 4 in Drapes/blinds None
20 N=>SE 19 Metal Low-E Double Yes OA9 0.24 6.0 ft2 1 ft 0 in 3 ft 2 in Drapes/blinds None
21 W=>NE 20 Metal Low-E Double Yes OA9 0.24 40.0 ft2 1 ft 0 in 1 ft 1 In Drapes/blinds None
22 W=>NE 20 Metal Low-E Double Yes OA9 0.24 6.0 ft2 1 ft 0 in 1 ft 1 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 685.99962666 ft2 685.99962666 ft2 77.8334 ft 9.3334 ft 0
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000297 1776.5 97.53 183.41 .2165 5
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block. Ducts
1 Electric Strip Heat None COP:1 42 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
-
1 Central Unit Split SEER:16 42 kBtu/hr 1260 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Main 0.95 50 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cart # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
i
1/17/2017 8:26 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6
r i
FORM R405-2014
DUCTS
r / —Supply— —Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 Attic 6 489.8 ft Attic 122.45 Proposed On Main —cfm 137.0 drn 0.06 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans: N
Coolin an Feb Mar A r Ma �( Jun Jul n Au Se Oct Nov Dec
Heating Jan Feb Mar E APr I
MaY [ Jun Jul AuSeP Oct Nov Dec
Ventin Jan Feb Mar lx]A r May [ ]]]Jun Jul Aug Se [xl Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 �80
PM 80 80 78 78 78 78 78 78 78 78 78 178
' Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
I
I,
1/17/2017 8:26 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX` = 99
The lower the EnergyPerformance Index,the more efficient the home.
3100 Bent Pine Drive, Ft Pierce, FL, 34951
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1977.10 f12
b.Frame-Steel,Adjacent R=11.0 278.44 ft2
3. Number of units,if multiple family 1 c.NIA R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
• 5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 2284.00 W
6. Conditioned floor area(ft2) 2284 b.Knee Wall(Vented) R=19.0 191.50 ft2
7. Windows" Description Area c.NIA R= ft211.Ducts R ft2
a. U-Factor: Dbl,U=0.49 196.00 ft2 SHGC: SHGC=0.24 a.Sup:Attic,Ret:Attic,AH:Main 6 489.8
b. U-Factor: Dbl,U=0.53 96.00 ft2
SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.46 70.17 ft2 a.Central Unit 42.0 SEER:16.00
SHGC: SHGC=0.26
d. U-Factor: other(see details) 37.58 W 13.Heating systems kBtu/hr Efficiency
SHGC: other(see details) a.Electric Strip Heat 42.0 COP:1.00
Area Weighted Average Overhang Depth: 7.073 ft.
Area Weighted Average SHGC: 0.240
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2284.00 ft2EF:0.95
b.N/A R= ft2
c.N/A R= ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building TTiS 5p
Construction through the above ener,,y ving-features which will be installed(or exceeded) tio� = ATBo
in this home before final inspection. t rwise, a new EPL Display Card will be completed
based on installed Code compliant f at es.
rr. u
Builder Signature: Date: ljq
Y111;o
Address of New Home:/00 n e City/FLlip: _Of P/C �r��
3 y�ri oDWE�
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/17/2017 8:27 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
. I
t - I
I
I
Building Analysis Job: Avalon Lot269
Y Date: 1-16-17
Entire House By: Skyetec
i�
- • . •
+ For: GHO Homes
3100 Bent Pine Drive, Ft. Pierce, FL 34951
Location: Indoor: Heating Cooling
Vero Beach, FL, US Indoor temperature(°F) 70 75 'I
Elevation: 26 ft Design TD (°F) 27 15 11
Latitude: 28°N Relative humidity (%) 50 50 .
Outdoor: Heating Cooling Moisture difference(gr/Ib) 22.0 61.5
Dry bulb(°F o 43 90 Infiltration: j
Daily range F) - 16 ( L ) Method Simplified
Wet bulb(°F - 78 Construction quality Average
Wind speed mph) .15.0 7.5 Fireplaces 0
j
•
Component Btuh/ft2 Btuh %of load m
Walls 3.8 6932 20.0 "
Glazing 13.3 5192 15.0
Doors 10.5 1200 3.5
Ceilings 0.9 1888 5.4
Floors 3.0 6616 19.1 l
Infiltration 1.7 3525 10.2
Ducts 6833 19.7
Piping 0 0
Humidification 0 0
Ventilation 2513 7.2
Adjustments 0
Total 34700 100.0
e • •
Component Btuh/ft2 Btuh % of load
Walls 2.4 4429 13.5
Glazing 19.4 7555 23.0 j
Doors 11.2 1274 3.9
Ceilings 1.0 2248 6.8
Floors 0 0 0
Infiltration 0.5 979 3.0
Ducts_ 8513 25.9
Ventilation 1396 4.2
Internal gains 6510 19.8
Blower 0 0
Adjustments 0
Total 32903 100.0
Latent Cooling Load= 10132 Btuh
I
Overall U-value=0.121 Btuh/ft2-°F
Data entries checked,
I
C Wrlghtsoft 2017Jan-1615:4j11 47
Right-Suite®Universal 2017 17.0.04 RS000269 Page 1
...ad Calculations%Skytec%Avalon Lot 269 GL NW.rup Calc=MJ6 Front Door faces:NW
i
1 '
Component Constructions
Job: Avalon Lot 269
Date: 1-16-17
Entire House By: Skyetec
• dct U#4r'
•
For: GHO Homes
3100 Bent Pine Drive, Ft. Pierce, FL 34951
y
Location: Indoor: Heating Cooling
Vero Beach, FL, US Indoor temperature(°F) 70 75
Elevation: 26 ft Design TD ("F) 27 15
Latitude: 28°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 22.0 61.5
Dry bulb(OF) 43 90 Infiltration:
Daily range(OF) - 16 ( L ) Method Simplified
Wet bulb( F) - 78 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions Or Area Ll-value Insul R Htg HTM Loss Clg HTM Gain
R' Btuh/t?'F ft'-'F/BNh BWh/R' Bluh BWh/R' Btuh
Walls
13A-4ocs:Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum n 12 0.143 4.0 3.86 47 2.50 30
board int fnsh ne 256 0.143 4.0 3.86 990 2.50 640
se 430 0.143 4.0 3.86 1662 2.50 1074
sw 344 0.143 4.0 3.86 1328 2.50 858
v/ 49 0.143 4.0 3.86 189 2.50 122
nw 478 0.143 4.0 3.86 1845 2.50 1'192
all 1570 0.143 4.0 3.86 6060 2.50 3917
Partitions
12131-0sm:Frm wall,stucco ext,r-11 cav ins,1/2"gypsum board int 265 0.122 11.0 3.29 872 1.93 512
fnsh,2"x4"metal frm,16"o.c.stud
Windows
2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" n 4 OA60 0 12.4 48 9.93 38
thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,
1/4"thk;NFRC rated(SHGC=0.26);50%blinds 45%medium;60%
outdoor insect screen;1.5 ft overhang(2 ft window ht,3 ft sep.);6.67 ft
head ht
2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" n 4 OA90 0 13.2 51 10.1 39
thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap;
1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45",medium;50%
outdoor insect screen;1.5 ft overhang(2 ft window ht,3 ft sep.);6.67 It
head ht
2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" n 12 0.490 0 13.2 165 10.1 125
thk:2 glazing,clr low-e outr,argon gas',vnl frm mat,clr innr,1/4"gap,
1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45",medium;50%
outdoor insect screen;1.5 ft overhang(6.5 ft window ht,3 ft sep.);6.67
ft head ht
2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" ne 8 0.460 0 12.4 99 19.9 159
thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,
1/4"thk;NFRC rated(SHGC=0.26);50%blinds 45%medium;60%
outdoor insect screen;9.6 It overhang'(2 ft window ht,2 ft sep.);6.67 ft
head ht
II
-`,{--WCI I7tSOft" 2017Jan-1615:44:47
f 9 RlghtSuite®Universal 2017 17.0.04 RS000269 Page i 1
t
'4'�...ad Calculations\Skytec\Avalon Lot 269 GL NW.rup Calc=MJ8 Front Door faces:NW
i
I
2 glazing,clr low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,114" ne 18 0.460 0 12.4 224 19.9 358
thk:2 glazing,cir low-e outr argon gas,vni frm mat,cir innr,1/4"gap,
1/4"thk;NFRC rated(SHGC=0.26);50%blinds 45%medium;60%
outdoor insect screen;1.5 ft overhang(3 ft window ht,1 It sep.);6.67 ft
head ht
2 glazing,Or low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,114" ne 8 0.460 0 12,4 99 19.9 159
thk:2 glazing,cir low-e outr,argon gas,vni frm mat,clr lnnr,1/4"gap,
1/4"IN;NFRC rated(SHGC=0,26);50%blinds 45°,medium;50%
outdoor insect screen;9.6 ft overhang(8 ft window ht,4 ft sep.);6.67 ft
head ht
2 glazing,cir low-e outr argon gas,vni frm mat,cir innr,114"gap,1/4" ne 30 0.490 0 13.2 397 19.2 577
thk:2 glazing,cir low-e outr argon gas,vni frm mat,cir innr,1/4"gap,
1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45%medium;50%
• outdoor insect screen;1.5 ft overhang(5 ft window ht,3 ft sep,);6.67 ft head ht ne 20 0.490 0 13.2265 19,2 384
all 50 0.490 0 13.2 662 19,2 961
2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr,114"gap,114" se 2 0.460 0 12A 23 10.5 19
thk:2 glazing,clr low-e outr,argon gas,vni frm mat,Or innr,114"gap,
1/4"thk;NFRC rated(SHGC=0.26);50%blinds 45%medium;50% w 2 0.460 0 12A 23 25.8 47
outdoor insect screen;3 ft overhang(2 ft window ht,3 ft sep.);6.67 ft nw 2 0.460 0 12A 23 '19.9 36
head ht all 6 0,460 0 12A 68 18.7 '103
2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr,114"gap,114" Be 9 0.490 0 13.2 119 15.0 135
thk:2 glazing,cir low-e outr,argon gas,vni frm mat,clr innr,1/4"gap,
1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45°,medium;50% sw 6 0.490 0 13.2 79 15.0 90
outdoor insect screen;1.5 ft overhang(3 ft window ht,1 ft sep.);6.67 ft nw 6 0.490 0 13.279 19,2 115
head ht
all 21 0.490 0 13.2 278 162 340
2 glazing,clr low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,1l4" Be 40 0,490 0 13.2 529 16.8 672
thk:2 glazing,cir low-e outr,argon gas,vni frm mat,cir Innr,1/4"gap,
1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45",medium;50%
outdoor insect screen;1.5 It overhang(5 ft window ht,1 It sep.);6.67 ft head ht sw 40 0.490 0 132 529 16,8 672
all 80 0.490 0 132 1058 16.8 1344
2 glazing,cir low-e outr,argon gas,vrll frm mat,cir innr,1/4"gap,1/4" sw 6 0.460 0 12A 75 9.93 60
thk:2 glazing,cir low-e outr argon gas,vni frm mat,clr innr,14'gap,
1/4"thk;NFRC rated(SHGC=0.26);50%blinds 45%medium;50%
outdoor Insect screen;5 ft overhang(1.5 ft window ht,1 ft sep,);6.67 ft head ht w 4 0,460 0 12,4 54 9.93 43
all 10 0.460 0 12A 129 9.93 103
2 glazing,cir low-e outr,argon gas,vni frm mat,cir Innr,l/4"gap,1/4" But 18 0.460 0 12A 222 9.93 178
thk:2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr,114"gap, -
1/4"thk;NFRC rated(SHGC=0.26);50%blinds 45°,medium;50%
outdoor insect screen;12 ft overhang(1.5 ft window ht,1 ft sep.);6.67
It head ht
2 glazing,clr low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,114" sw 24 0.490 0 13.2 318 11.4 274
thk:2 glazing,cir lows outr,argon gas,vni ftm mat,cir innr,ll4"gap,
1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45%medium;50%
outdoor insect screen;5 ft overhang(6 ft window ht,3 It sep.);6.67 it head ht w 17 0.490 0 13,2 225 21.9 372
all 41 0.490 0 13.2 542 15.8 646
2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,1/4" sw 96 0.530 0 14.3 1374 10.7 1031
thk:2 glazing,clr low-e outr,argon gas,vni frm mat,cir lnnr,1/4"gap,
1/4"thk;NFRC rated(SHGC=0.25);50%blinds 45,medium;50%
outdoor insect screen;12 ft overhang(8 ft window ht,3 ft sep.);6.67 ft
head ht
2 glazing,clr low-e outr,argon gas,vni frm mat,clr innr,1/4"gap,1/4" w 2 0,490 0 13.2 24 10.1 18
thk:2 glazing,clr low-e outr argon gas,vni frm mat,Or innr,1/4"gap,
1/4"thk;NFRC rated(SHGC=0.24);50%blinds 45°,medium;50%
outdoor insect screen;10 ft overhang(2 ft window ht,3 ft sep.);6.67 ft
head ht
2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,1/4" nw 12 0.460 0 12A 149 19.9 238
thk:2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,
1l4"thk;NFRC rated(SHGC=0.26);50%blinds 45°,medium;50%
outdoor Insect screen;1.5 ft overhang(2 ft window ht,1 ft sep.);6.67 ft
head ht
I
AL
wri ht"ft' 2017-Jan-1615:44147
��� 9 RtghtSulte®Universal 2017 17.0.04 RS000269 Page 2
..ad CalculatlonsMylect,4valon Lot 269 GL NW.rup Cale=MJ8 Front Door faces:NW e�
I � �
�I
Doors
II DO:Door,wd sc type ne 24 0.390 0 10.5 253 11.2 268
se 23 0.390 0 10.5 239 11.2 253
w 23 0.390 0 10.5 239 11.2 253
nw 23 0.390 0 10.5 239 11.2 253
n 22 0.390 0 10.5 232 11.2 246
all 114 0.390 0 10.5 1200 11.2 .1274
Ceilings
16D-30td:Attic ceiling,tile,slate,concrete roof mat,r-30 cell ins,1/2" 2185 0.032 30.0 0.86 1888 1.03 2248
gypsum board Intfnsh
Floors
r 22A tpm:Bg floor,heavy dry or light damp soli,on grade depth,the fir 208 1.180 0 31.9 6616 0 0
fnsh
I
Wrl htSOft" 9 2017Jan-161544:47
JCZAL 9 RIhtSuite®Universal 2017 17.0.04 RS000269 PIa e 3
AP ...ad Calculations%SkytecWvalon Lot 269 GL NW.rup Cale=MJ8 Front Door faces:NW
Project Summary Job: Avalon Lot 269
- Date: 1-16-17
Entire House By: Skyetec
For: GHO Homes
3100 Bent Pine Drive, Ft. Pierce, FL 34951
Notes:
- • • •
Weather: Vero Beach, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 43 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 27 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 27867 Btuh Structure 24391 Btuh ;I
Ducts 6833 Btuh Ducts 8513 Btuh
Central vent(0 cfm) 0 Stuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 34700 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 31258 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 , Structure 7420 Btuh
Ducts 2712 Btuh
Heatingg Coolingg
Area(ftz Central vent(0 cfm) 0 Btuh
2185 2185 Equipment latent load 10132 Btuh
Volume�ft') 22277 22277
Air changes/hour 0.32 0.16 Equipment total load 41390 Btuh
Equiv.AVF(cfm) 119 59 Req.total capacity at 0.80 SHR 3.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Rheem
Trade Trade RHEEM; RUUD
Model Cond RA1642AJ 1
AHRI ref Coil RHIT4821STAN
AHRI ref 7942888
Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER
Heating input 12.3 kW Sensible cooling 33200 Btuh
Heating output 41975 Btuh Latent cooling 8300 Btuh
Temperature rise 28 OF Total cooling 41500 Btuh
Actual air flow 1383 cfm Actual air flow 1383 cfm
Air flow factor 0.040 cfm/Btuh Air flow factor 0.042 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.76
i
i
t
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
c - - wrightsoft• 2017.1an-1615:441:a7
RightSuite®Universal 2017 17.0.04 RS000269 ll Pag 1
...ad calculations%Skytec%Avalon;Lot 269 GL NW.rup Calc=MJ8 Front Door faces:NW
{ i
s
------------------ --
N
' I
Avalon
' WIC Q6ana a x 8 m
j t 41 dm t 83 dm
6 11.3 ft
7',7.1 R
8 x 8 Nook 10 x 10 Master Bedroom
98 dm 136 dm
BR 2 5.T < t
4',5.4 ft
4•,17.9It /8',11.8it 6x6
2 cfm
12x12 10',11.2R ? 12x12 ,
12 x 12 250 cfm
253 dm
7',8.3 ft Mohan F 10'112.6 ft
8 x 8 10 x Great R
108 dm t 163 H r
BR3 10',14.4ft 7',7.9ft
14 R 30 x 18 10 x 10 8 filers
129dm 12',9.01 .� 6x6
112x12ft 18 ,10.7ft 58d
4.4.6ft
Hal
4',5.0ft 6x6 6ax8 H 4',10.7R
@ath 2 38 cfm 1 y F
F 8x8 6x6
48 dm 4'. it 161, 1 16',19.2 ft Foyer 24 x 18n 21 dm
Utay 20',8.0 ft Y
1
8',10.2 ft
164 dm
M Bath O
a F
t Dining
16',10.0 ft
a 1
4',4.8ft 6x6
22 d
Schedule
Garage F Exhaust Fan
3.5 Tan )
R Range Vent
DD Dryer Vent
Rheem Equipment ARl7942888
AHU 3.6 Ton 16 SEER RH1T48
Cand 3.5 Ton 16 SEER RA1642
{I
l
Job#:Avalon Lot 269 Scale:1 :121 ��
Performed by Skyetec for: Page 1
GHO Homes RightSuite®Unlversa12017
69
3100 Bent Pine Drive 117-Jan 161100 4:5
Ft.Pierce,FL 34951
2017,Jan-1615:44:55
'� ...1SkyteclAvaton Lot'269 GL Iti W.rup
i
Duct System Summary Job: Avalon Lot269 j
Date: 1-16-17
Entire House By: Skyetec
For: GHO Homes
3100 Bent Pine Drive, Ft. Pierce, FL 34951
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0.18 in H2O 0.18 in H2O
Available static pressure 0.32 in H2O 0.32 in H2O
Supply/return available pressure 0.209/0,111 in H2O 0.209/0.111 in H2O
Lowest friction rate 0.102 in/100ft 0.102 in/100ft
Actual air flow 1383 cfm 1383 cfm
Total effective length(TEL) 313 ft
• • Detail Table,
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (Cfm) (cfm) FIR (in) (in) Matl Ln(ft) Ln(ft) Trunk
•-A h 556 22 13 0.200 4.0 Ox0 VIFx 4.8 100.0
BR 2. c 2341 79 98 0.111 6.0 Ox0 VIFx 33.7 155.0 st4
BR 3 C 2569 95 108 0.109 7.0 Ox0 VIFx 36.3 155.0 st4
Bath 2 h 1211 48 34 0.139 4.0 Ox 0 VIFX 15.0 135.0 st2
Cabana h 2087 83 49 0.105 6.0 OXO VIFX 39.3 160.0 st4
Dining h 3247 129 101 0.122 7.0 Ox0 VIFX .31.0 140.0 st1
Foyer h 1319 53 44 0.125 4.0 OX0 VIFx 27.7 140.0 st1
Great Room-B C 6022 158 253 0.120 10.0 Ox0 VIFx 34.3 140.0 st1
Hers h 1457 58 24 0.104 5.0 Ox 0 VIFx 41.2 160.0 st3
His C 53 2 2 0.106 4.0 Ox0 VIFx 37.6 160.0 st3
Kitchen C 3867 34 163 0.107 8.0 OXO VIFx 39.7 155.0 st4
M Bath. h 4127 164 91 0.103 8.0 OX0 VIFX 42.3 160.0 st3 j
Master Bedroom h 6272 250 197 0.102 10.0 Ox 0 VIFx 44.8 160.0 st3
Nook C 3226 133 136 0.110 7.0 Ox0 VIFx 35.1 155.0 st4
utility c 906 12 38 0.139 4.0 Ox0 VIFx 15.5 135.0 st2
WC h 5.21 21 17 0.103 4.0 Ox 0 VIFx 42.9 160.0 st3
Wic h 1029 41 15 0.104 4.0 Ox0 VIFx 45.8 155.0 st4
,I
i
i
Hold/Italic values have been manually overridden
j
2017Jan-16 15:4447
- - wrightsoft• Right-Suite®Universal 2017 17.0.04 RS000269 Page 1
...ad Calculations\SkylectAvalon Lot 269 GL NW.rup Calc=MJ8 Front Door faces:NW
Supplk Trdnk Dikaii Ta.16-
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (Cfm) FIR (fpm) (in) (in) Material Trunk'
st3 Peak.AVF 495 331 0.102 630 92.0 0 x 0 VinlFlx stfl
st1 Peak AVF 835 729 0.102 598 16.0 0 x 0 VinIFIX
= st4 Peak AVF 466 569 0.104 532 14.0 0 x 0 VinlFlx st21
st2 Peak AVF 526 641 0.104 459 16.0 0 x 0 VinlFlx
Rdiurh ,Branch-Detail •
• Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm). (cfm) (ft) FIR (fpm) (in) (in) Opening_(in) Mati Trunk
rb1 Ox 0 1383 1383 108.7 0.102 634 20.0 Ox 0 VIFx rst6
s
betaillrable-
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (Cfm) (Cfm) FIR (fpm) (in) (in) Material Trunk
rst5 Peak AVF 1383 1383 0.102 634 20.0 0 x 0 VinlFlx
rst6 Peak AVF 1383 1363 0.102 783 98.0 0 x 0 VinlFlx rst5
Bold/Italic values have been manually overridden
2017Jan-1615:44I 7
C - �-wrightsoft° RlghtSulte®Universal 2017 17.0.04 RS000269 II
Page 2
..,ad Calculallons\Skytec\Avalon Lot 269 GL NW.rup Cale=MJ8 Front Door faces:NW
i
i
- J Planning&Development Services Department
�'st4r:��.` :J Building&Code Regulations Division
2300 Virginia Avenue, Fort Pierce,FL 34982-(772)462-1553
Certification for Design Load Compliance
Project Name: MW 26>9
Project Address:� - / 00 & eA4 P/l),e ��/� , �� �rG e
J
r, Permit#: Occupancy Type:_ Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed,signed,and sealed by the design professional of record.
• Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following:
o New Residences(single or multi-family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official.Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
7-0Buildin 0 I7`
N/A
1. DESIGN CODE: Florida 9 Code Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as(check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft
5. Mean Roof Height 1,4,7 ft Roof Pitch: 6 :12 Parapet: NIA ft
6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label an all plan openings):
+4%,V y fi161,IV s-[17, n qe33'6 ?
Zone 1:-31•y- Zone 2.-yYA1' Zone 3:— Zone 4:700 3Y`Lone 5: y F-- Garage:
7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NIA PSF
Dock: NIA PSF Deck: N/A PSF Stairs: NIA PSF Fence: N/A PSF Railings: NIA PSF
8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that,to the best of my knowledge and belief,the attached plans&specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Print Name Cert#&Co.Cert Auth.
,�C�
t e,Da ;and S I C 1&3`J ��� �E�f�'Yi� J�`L� �-�� 1�
Company Name Address
Revised /25I20 4
Planning & Development Services Department
Building & Regulations Division — -
f-117 Product Review affidavit
Building Permit# Owners Namec-2) Mtcdowood & . Applicant: (—,,t�2 LLo m-&o
Product Opening Design Product Rated Manufacturer Moddl Number Product Approval Glass Method of Attachment
Pressures Design Pressure Number T e
Windows +32.4 /-35.3 +/-55 MI WINDOWS FL 17499.6 NONIMPACT 3/16"TAPCONS W/ 1-1/4" MIN. EMBED @ 12" 01C
Mullions 37.7 +/-54 MI WINDOWS FL 15353 NONIMPAC7 1/4" TAPCONS W/ 1-1/4" MIN. EMBED
Fixed Glass +33.5 / -36.3 +/- 55 MI WINDOWS FL 15349.6 NON IMPACT 3/16"TAPCONS W11-1/4" MIN. EMBED @ 12" O/C
Block Glass
Skylights
Sliding Glass Doors +28.5 /-31.3 +/-55 MI WINDOWS 12080 FL 15332.5 NON IMPACT 3/16"TAPCONS W/ 1-1/41' EMBED @ 12" 0/G.
Swing Tye Doors +31.9 /-34.8 +/-50 THERMA TRU 2880 FL-7630.1 NON IMPACT 1/4"TAPCONS W/ 1-1/4" MIN, EMBED
French Doors
Garage Doors +28.1 /-31.9 +39.2/-43.7 WAYNE DALTON 9100 FL-9174 RI N/A 5/16"x 1-5/8" LAG SCREW EA. BRACKET
Hurricane Protection 37.7 +49.0/-56.0 NURM.12STOR.PANELMAI 16293-R1 N/A 1/4"-200/4"S.S.KNURLED STUDS 12-1/2'O.C.TOP&BTNi
Roof Ventilation
Roofing Material -83.4 PSF -172 PSF CAPISTRANOCONC.TILE NOA NO. 16-0314.08N/A (2) 10d RING SHANK NAILS
Revised 07/22/2014
` I have reviewed the above components or cladding and I have approved their use in ucture. These products provide adequate i esistafic'6 to the
wind loads and forces specified by current code provisions.
Name: i4je1lSZ.�-tip �i/GiJ .��2�1 Signature: ;s al'
Design Prof:Anl�4c'o it Cert.No. Date:
o u ,R
1
Nuelle Engineering Date: 3/14/2017
Donald J. Nuelle P.E.
11634 SW Rowena Street
Port St. Lucie, FL 34987
Cellular 561-629-6975
St. Lucie County
Planning & Development Services
Building & Code Regulation
2300 Virginia Avenue
Fort Pierce, FL 34982
Attn: William Durden
Re: MW-269, Permit# 1701-0520
Plan Review Comments
Dear Mr. Durden.:
Per Your request, I have investigated th
e applied pressures on the C & C
for the above referenced structure. The re-calculation shows the new numbers to
be within 1 — 1'h psf of those shown on the drawing. The pressures were
calculated using MecaWind Pro 2.2.7.5 per ASCE 7-10 and are based upon ASD
Design. The existing pressures shown the drawing are correct in my professional
opinion. Input and output data from the program run can be provided if
requested.
If you or.any other interested party has any questions or requires
additibnaf,'information please feel free to contact me at any time.
ald-J.' iielle =
LL
P.E. # 20 6
y,4
B ILE C py,0