Loading...
HomeMy WebLinkAboutproduct approval (2) APPROVAL Gulfca&t SUPPLY & MANUFACTURING TM U L F R � RD) • GLIAGE GULFRIB TM PANEL OVER PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 Im Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, LLC. 26 Ga. GulfRibTIVI Roof Panel over 15132"Plywood Florida Product Approval #11651.22 R2 Florida Building Code 2014 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing { Compliance Method: 61 G20-3.005(1)(d) E NON HVHZ opy Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 Engineer Evaluator: ®an Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 ;per .. �STATEOF Fri•., OR to.P .•�kr� Validator: ��'%r�0NAL SO`�� Locke Bowden, P.E. #49704 '"" '''`% 9450 Alysbury Place 15 Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FL#11651.22 R2•JUNE 15,2015 11670 IS 1 LAKES LANE, i• • J APPROVAL Gulfca&t SUPPLY & MANUFACTURING TM GULFRH = ULFRIBTM PANEL OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 TM Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Product Description: GulfRibTM 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over minimum 15/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.Oksi Corrosion Resistance: Panel Material shall comply with Florida Building Code. 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 3/a" Major Rib at 9" O.C. Panel Fastener: #9-15x1:5" HWH with sealing washing or approved equal 1/a" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick,APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2014. Design Uplift Pressures: Table"A" mu,�m Total Uplrft Design Pressure 69.2�5 psf 159.2+-5 psf Fastener Pattern 9"-9"-9"-9" 6.5"-2.5"-6.5"- 2.5"6.5"-2.5"-6.5" astener Pattern Soacmg 24" O.ii. IMIM Design Pressure includes a Safety Factor=2.0. I FL#11651.22 R2•JUNE 15,2015 . . , , , . , . ENGINEERING, /`e;; �i` Gulfc&gt SUPPLY & MANUFACTURING TM ILGULFHD-., L2) • GUAGE GULFRIBTM PANEL OVER • • FLORIDA PRODUCT APPROVAL NO. 11651.22 i,, TM Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-04- Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/1897-98.Uplift Test Force Engineering &Testing, Inc.(FBC Organization #TST 5328) Report No. 117-0062T 07A, B, Dated 02/19/2007 2. Certificate of Independence By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC (FBC Organization #ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: ' Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2. I i i FL#11651.22 R2•JUNE 15,2015 PRODUCT EVALUATION REPORT • RON GulfC&M SUPPLY & MANUFACTURING 0 TM GULv LM H L2) 26 GUAGE GULFRIBTMPANEL OVER • • FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 TM Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table,fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design.The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. I I I i FL#11651.22 R2•1UNE 15,2015 PRODUCT , REPORT I ® Gulfc5y�f SUPPLY & MANUFACTURING GULFRIB TM 26 GUAGE GULFRIB TM PANEL OVER PLYWOOD s, FLORIDA PRODUCT APPROVAL • ve TM I ENGINEER LOAD TABLE: 26 Ga. GulfRibTM Panel over 15/32"Plywood Buildingshaving a Roof Mean Heig�2-2, '�oFof SP©pffl- "fflnFl,�".- r / WIC Si .5d atsre C Risk Categoryuildg, ida Bulll Ling Code 2034. 120 130 140 150 160 170 180 WIIND ;FASTENER SUBSTRATE SPEED (MIN.1/4" (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING a-d 'tiff � ��� ���F., ZONE,1, #9'L15X,15 � OOd 24",TYPE 1 24' TYPE1 24 TYPE 1 24",TYPE 1 24",TYPE 1 24 TYPE 1 24",TYPE 1 ". ZONE 2 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 12",TYPE 2 rwZONE43 #9�15x115" PIywOOd 24",TYPE 1 24",TYPE 1 24",TYPE 1 12 TYPE 2 12",TYPE 2 12", PE 2 12",TYPE 2 1.)PANEL DESCRIPTION:GULFRIBTM,MIN.26 GA., GRADE 80,36"COVERAGE, 3/4"TALL. 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125,UL 580/UL 1897 TESTING. 4.)PLYWOOD DECKING:MIN.15/32"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2014 zoNE2 RIP ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or --------- ZONE 3 , 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be --- 3a less than either 4%of the minimum width of the building or 3 feet. / /1 TYPE 1 FASTENER PATTERN \\\ \\ -----RIDGE — /// // I �9° 9° 9° 9° -- Panel Lap ZONE 1 \ \\ Cont.Tape Seal for use on Slopes less than 3:12 / \ \ (1)#9-15 x 1-112'w/Sealer Washer p 2,V O.C.Max TYPE 2 FASTENER PATTERN ZONE 2 GABLE ROOF {-- 6.5°--{2.5" 6.5" 2.5°{--6.5" 2.5°y-6.5° 2.5' I I I t / RIDGE L Cont Tape Seal for use on Slopes less than 3:12 ----- -- ------------ 1 (1)#9-15x1-1/2'w/Sealer Washer@IT O.C.Max — a +--------------------- I a I ZONE 1 I I ----------------------I ZONE3 EAVE FL#11651.22 R2•JUNE 15,2015 r . r 1 BOCA RATON, • #30464 CREEK Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 TfiCHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT 2014 FLORIDA BUILDING CODE Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued April 13, 2015 P.O. Box 1404 Joplin, MO 64802 (417)624-6644 http://www.tamko.com Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.2.3, 1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5.1, 1507.4.5.2, 1507.4.5.3, 1507.5.3, 1507.5.3.2, 1507.6.3, 1507.6.3.2, 1607.6.5, 1507.7.3, 1507.7.3.2, 1507.8.3, 1507.8.3.2, 1507.8.8,T1507.8, 1507.9.3, 1507.9.3.2, 1507.9.5, 1507.9.9 Properties: Physical properties REFERENCES Enti Report No. Standard Year PRI Construction Materials Technologies(TST6049) TAP-191-02-01REV ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2005e01 PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2006 PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2009) PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2009) PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2006 PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2006 PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2009) PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2005e01 UL LLC(TST9628) 13CA12269 ASTM D 226 2006 PRODUCT DESCRIPTION AND APPLICATION - ;I[-,E Y TAMKO®ASTM Slate ASTM D 6380, Class M,Type 11 underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. Min.slope: 2:12 Application: The underlayment shall be installed with minimum 2° side laps and minimum 4" staggered end laps and in accordance with FRSA/TRI 07230 for file applications. Allowable roof coverings: Attachment of asphalt shingle valleys and clay and concrete-tile shall be permitted in accordance with the FBC. TBP14001.1 FL12328-R5 Page 1 of This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i "