Loading...
HomeMy WebLinkAboutCompaction Test Ar an & Associatesdfc. ertificate of Authorization No. 5950 RE -WED 460 NW Concourse Place, Unit 1 Port St. Lucie, Florida 34986 NOV 0 6 2017 Phone: (772) 878-0072 TING Fax: (772) 878-0097 Lucie ounty, St. Lucie County, FL FIELD DENSITY TEST REPORT PROJECT: Morningside FILE NO.: 15-5434A REPORTED TO: Renar Homes DATE OF TEST: 10/31/2017 Permit No. 1707-0484 TEST MDR MOISTURE DRY PERCENT DEPTH NO. House Pad at 9315 Treasure Coast Street NO CONTENT DENSITY COMPACTION LOCATION 1 Northwest Corner 1 10.0 114.5 98 0 to-1' 2 Southwest Corner 1 11.9 114.5 98 0 to-1' 3 Southeast Corner 1 11.8 112.9 96 0 to-1' 4 Center 1 11.0 113.0 97 0 to-1' 5 Northeast Corner 1 13.0 112.5 96 0 to-1' *DENOTES IN-PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT FIELD TEST: ASTM D-2937 r ASTM D-6938' i ASTM D-2167 ASTM D-1556 TECHNICIAN: CF Test depth referenced from: LABORATORY MOISTURE-DENSITY RELATIONSHIP Top of House Pad MDR ASTM MAX. OPTIMUM NO. TEST METHOD DENSITY MOISTURE CONTENT 1 D-1557 117 PCF 10% Remarks: ® O. 63999 087ATE o� � Zr Ilack, P.E. ON % A%f ••F4 Li ense#63911 ASA MUTUAL PROTECTION TO CLIENTS,THE PUBLIC AND OURSELVES,ALL REPORTS ARES ® 'AI(�I r.ERTY OF CLIENTS AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS,CONCLUSIONS OR EXTRACTS FROM OR REGARD �96 T 9®Etf; A�I/ D PENDING OUR WRITTEN APPROVAL. 99 1111919