HomeMy WebLinkAboutCompaction Test Ar an & Associatesdfc.
ertificate of Authorization No. 5950 RE -WED
460 NW Concourse Place, Unit 1
Port St. Lucie, Florida 34986 NOV 0 6 2017
Phone: (772) 878-0072
TING
Fax: (772) 878-0097 Lucie ounty,
St. Lucie County, FL
FIELD DENSITY TEST REPORT
PROJECT: Morningside FILE NO.: 15-5434A
REPORTED TO: Renar Homes
DATE OF TEST: 10/31/2017 Permit No. 1707-0484
TEST MDR MOISTURE DRY PERCENT DEPTH
NO. House Pad at 9315 Treasure Coast Street NO CONTENT DENSITY COMPACTION LOCATION
1 Northwest Corner 1 10.0 114.5 98 0 to-1'
2 Southwest Corner 1 11.9 114.5 98 0 to-1'
3 Southeast Corner 1 11.8 112.9 96 0 to-1'
4 Center 1 11.0 113.0 97 0 to-1'
5 Northeast Corner 1 13.0 112.5 96 0 to-1'
*DENOTES IN-PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT
FIELD TEST: ASTM D-2937 r ASTM D-6938'
i ASTM D-2167 ASTM D-1556
TECHNICIAN: CF
Test depth referenced from:
LABORATORY MOISTURE-DENSITY RELATIONSHIP Top of House Pad
MDR ASTM MAX. OPTIMUM
NO. TEST METHOD DENSITY MOISTURE
CONTENT
1 D-1557 117 PCF 10% Remarks:
® O. 63999
087ATE o�
� Zr Ilack, P.E.
ON % A%f ••F4 Li ense#63911
ASA MUTUAL PROTECTION TO CLIENTS,THE PUBLIC AND OURSELVES,ALL REPORTS ARES ® 'AI(�I r.ERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS,CONCLUSIONS OR EXTRACTS FROM OR REGARD �96 T 9®Etf; A�I/ D PENDING OUR WRITTEN APPROVAL.
99 1111919