FP • GUAGE GULFRIBTM PANEL OVER PLYWOOD
FLORIDA PRODUCT APPROVAL l O. 11651.22 R ,
TM '
• a
Product Evaluation Report
GULF COAST SUPPLY& MANUFACTURING, LLC ,
26 Ga. GulfR/bTM Roof Panel over 15132"Plywood
Florida Product Approval #11651.21R2TCTF COU Tv RTTU,nTV'n nn1SION
Florida Building Code 2014 RErJiF'«���FOR REVIEWED BY CCN;PLL':NCE
� -�-
Per Rule 61 G20-3 DATE (,!q
Method: 1 -D PLAINS A_ND PE& IIT MUST BE KEPT ON JOB
OR NO INSPECTION WILL BE NUDE,
i
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61 G20-3.005(1)(d)
NON HVHZ
Product Manufacturer:
Gulf Coast Supply & Manufacturing, LLC.
14429 SW 2nd Place, Suite G30 �•``NjEL SIIk ''
Newberry, FL 32669 ;`SOP•' ''''•• �h:'•
No, 7,551
Engineer Evaluator: s
Dan Kuhn, P.E. #75519 — -�•
Florida Evaluation ANE ID: 10743 �0 �STgTE OF . .co
;Fsi CpRypP .•��li�:
Validator: 01VAI.
Locke Bowden, P.E. #49704 0 6 I o 20�
9450 Alysbury Place �3 5
i Montgomery, AL 36117
Contents:
Evaluation Report Pages 1 -5
I
FL#11651.22 R2•JUNE 15,2015
. ® , ► • •
I
iKUHN ENGINEERING,
I
1
TM
SUPPLY & MANUFACTURING
on
Rf
TM
IL
�✓ _ter I
e a l�l t.t18.9
y
GULFIR
■ J
7
l 4Version 01-26-1
r
r "v (See back cover)
i
® GuIX66
SUPPLY & MANUFACTURING
The Gulf Coast Gulf Rib®
Roofing Panel
Gulf Coast Gulf rib®panels are a strong,
durable, economic, and attractive answer to
-- A_:Lthe growing demand for metal roofing needs
in Florida and southern Georgia. Extremely
versatile, they are suitable for homes and
businesses as well as agricultural and utility
}� buildings Gulf Rib'panels provide a 36-
inch coverage with 3/4 inch ribs on nine-inch
centers, and utilize an anti-siphoning channel
Figure 1 The Horseshoe Beach Gulf Coast Supply to provide protection from severe weather
office(left)and manufacturing facility.
conditions. Both panels and trim are fabricated °
Mobile �
using state-of--the-art computerized equipment onvIl�e,
Tallahassee
found at our facilities in three locations in Florida, ► °
to assure uniformity and consistency in product ; *�Alacival
!Horse_"sho e*
manufacture. Panels are roll-formed to the lengths # `Bea�hl Ocala i
specified by customers in either Galvalume or 1-75, Orlando
� o
any of more than twenty colors of painted 29- riou oA
gauge, 26-gauge, and 24-gauge high-tensile metal, T_ P, -
read for either customer pickup or on-site deliv-
y p P Sebring
ery(customers should call about availability of _3
24-gauge metal).Your Gulf Coast representative f�► :Stuart;
is waiting to assist you in making the best choice �fof I f
for your particular roofing needs. I Mlaml'
Gulf Coast's Gulf Rib®panels are fabricated E�
from AZ-50 (painted) or AZ-55 (bare
Galvalume) grade 80 coil stock(grade 50 for 24 Figure 2 The 4 locations of Gulf Coast Supply.
bare Galvalume finish is not only durable and cost effective,but offers reflectivity so valuable
here in the South. The paint system employed on painted
- products offers optimum exterior protection plus superior
resistance to corrosion and ultraviolet radiation.
While bare Galvalume carries a 25-year
fw, limited coil manufacturer's finish warranty,
Figure 3 The Gulf rib panel �t-9"—o l most painted metal carries a 40-year war-
ranty. Both painted and unpainted are of the
highest known quality in the industry.
Gulf Coast also stocks a complete line of fasteners, sealants, and other accessories to meet
every need of both the do-it-yourself homeowner and the roofing contractor.A complete line of
both in-stock and custom-made flashings and trims are available in all colors as well.
: : : . .
b
B .. DETAILMANUAL
GULF Rl
Gulf0ast
SUPPLY & MANUFACTURING
Installation of Panels
Roof Pitch
Gulf Coast roofing panels require a certain degree of pitch to ensure proper water drainage.
Florida Building Code allows a minimum pitch of 2/12 for Gulf Rib®panels as long as lap screws
and sealant are applied to the laps to prevent water from siphoning over the ribs(see Fig. 5 on p.4).
Lap screws and sealant are optional when the pitch is 4/12 or greater(4/12 pitch means that there is 4
inches of rise for every 12 inches running horizontally). As a general principle,the less steep the roof,
and the more necessary also that sealant be used at all side-laps. Consult our representative for
recommendations for your particular roof pitch, and about roofing options if you have less than a 2/12
pitch.
Roof Preparation
Oil-canning is a wave-like,rippled appearance extending up the length of the panel after it has
been installed on the roof. Any irregularities in the roof,including uneven plywood joints,warped
plywood, uneven trusses,poor application of underlayment,the use of button caps with felt paper, etc.,
can promote oil-canning. Care should be taken to provide a flat,uniform surface on which to attach
the panels. See page 6 for more details.
Roof Application
Panel installation should begin at the gable end of the roof opposite the prevailing rain-bearing
wind(this will provide added assurance against wind-driven rain being forced under the laps). Measure
one panel width in from the roof edge. At this point chalk a line from ridge to eave. Place the leading
edge of the first panel along this line. It is extremely important that this panel be laid square to the eave
and ridge so that the remaining panels will line up square on the roof frame.It is wise to have a person
at the eave and at the ridge to ensure that the proper panel coverage is being maintained across the roof.
Also be sure that the panels are properly side-lapped(see fig. 7 on page 7).
In applications where end-lapping is necessary,the upper panel on the slope should lap over the
panel that is lower on the slope by about 12 inches. Lesser roof pitches require a greater amount of
panel overlap. All end-lap applications should use two horizontal rows of butyl sealant tape across the
panel and proper fastening to provide a maximum water seal.
An overhang of 2 to 3 inches on the eave is recommended to provide a drip edge,while only 1
inch overhang is necessary where gutters are used. The open panel ribs at the eave can be sealed with
inside closures. For maximum weather-tightness, a row of butyl tape can be applied above and beneath
closure material.
Trimming and Cutting Steel Panels
The best device for cutting steel panels across the profile is either hand snips or a nibbler.
Nibblers, and especially Carborundum blades on electric saws,however, do have a tendency to either
leave hot metal particles that can burn paint surfaces or to leave rust marks on panels and trim. The
same is true of any filings left on the roof caused by the application of screws. Care should be taken to
brush all such particles from roof surfaces after application.
To cut panels lengthwise: Note carefully where the panel is to be cut,and, using a straightedge,
score deeply down the length of the panel with a sharp-pointed utility knife.Folding the panel along the
score mark,and bending back again if necessary,should produce a clean break in the panel.
CAUTION! clean all metal shavings and particles off of roof to avoid unsightly rust stains
: : : . .
/ u` d
GULF RIB` DETAIL MA NUAL Gulf Cast
SUPPLY & MANUFACTURING
Residential Trim
Seep. 12 for Siding Trinzs Valley Ridge cap
Endwall p• 9)
able trim flashing
Sidewall
Flashang
9
ti
rip
gyp. 8)
Panel lap detail
Roll Lite Door Lap Screw Apply sealant
to lap
overlaps,
Transitio ---
j Fl"asking _ �purlin bearing leg _ decking
(p.10)
Figure 5 Butyl tape or caulk is required when the
roof pitch is 3/12 or less, with lap screws applied
every 2 feet to maintain water-tightness of the lap.
On pitches greater than 3/12,lap screws and butyl
Figure 4 Roofing trims and flashings are named by the tape are optional. For more details on screws,
location or function of that particular piece on the building. see pgs.6 and 7.
GULFRIB`=[U*f. I ® GUAfCOast
SUPPLY & MANUFACTURING
Ordering Roof Panels and Screws
Care should be taken to order panels of the correct length to avoid having to make
corrective measures after purchase. Panel lengths should fall 2 to 3 inches short of the ridge wizen
a vented ridge is desired, and should extend 2 to 3 inches past the eave to allow a sufficient drip
edge(except as noted on pg. 3 concerning gutters). When a roof transition is involved, panels of
the upper portion should be ordered short to allow placement of the transition flashing (see
diagram on p. 10). The Gulf Coast sales personnel are ready to assist customers with information
specific to their particular roof.
Specially-washered screws applied through the flat of the metal is the most recommended
method used to attach roofing panels. 1-inch screws can be used if penetration of only 1/4 inch is
either necessary or desired; otherwise, 11/2 inch screws are usually recommended. 21/z inch screws
are also available, and are often used by those who adhere to through-the-rib fastening, and for
ridge-cap application. See pages 6 and 7 for more information on screw spacing and ordering.
Ordering and Applying Trim
The most common flashing for metal roofing is the ridge cap,which is used at the peak of a
roof where two opposing roof slopes join. Other fleshings include transition flashing,end wall
and sidewall flashings, and valleys(see diagram on right for application). Eave trims include
gable flashing and eave drip, either of which are often applied above fascia trim. When roof pitch
exceeds 5/12 (a 5 inch rise in 12 inches), the slope of the roof should be mentioned when ordering
ridge caps, endwalls, and eave drip. When a steeper roof slope meets a lesser slope,both slopes
should be mentioned when ordering transition flashing.
At the gable edge the use of gable trim adds to the appearance of the structure and protects
the fly-rafter, and sidewall flashing is used where the side of a panel butts up against an adjacent
wall. In either case, the installer should be careful to seal between the gable rake or sidewall and
panel with butyl sealant tape, and to fasten the rake every 6" to 12" up the slope of the roof with
the appropriate screws. If eave drip is used on the gable, the number of 90 degree eave drip
should be specified separately from that used on the drip edge when ordering.
To prevent penetration of water, insects, and debris at the ridge; outside closures should be
inserted between the ridge cap and the top end of the panel. Screws are applied through the ridge
cap, closure, and rib in at least every other rib of the panels.At least a 11/2" (or preferably 21h")
screw should be used for attaching ridge caps. Self-drilling lap screws can also be used to attach
ridge caps.
Keep Materials Dry!
Paint and finishes of Gulf Coast panels and trim are designed to withstand severe rain and
wet weather conditions. Neither paint, galvanized, or Galvalume finishes,however, are designed to
be in continuous contact with water for long periods of time. Damage will result if uninstalled
panels or trim are allowed to remain wet in storage Be sure to store material that will not be
installed immediately in a dry location. Wet material should be air-dried and re-stacked if
installation is not planned right away.
. .
I
IN
GULF RIB` DETAIL MANUAL
GUIK66 t
SUPPLY & MANUFACTURING
How to Figure and Apply Screws Screw urlin)Spacing
12 inch 18 inch 24 inch
ti 50' 270 180 135
Gulf Coast Supply carries screws in 3 different lengths: I inch, 11/2 o 100 540 360 270
inch, and 2 inch. I-inch screws will barely penetrate a Ix4,but the o 200 1080 720 540
11/2 inch are the best all-purpose size. 11/z-or 2'/Z-inch screws are 300 1620 1080 810
necessary for attaching ridge caps. The table on the right can be 400 2.160 1440 __1080
500 2700 1800 1350
used to figure approximate quantities of screws for various purlin
¢ 600 3240 2160 1620
spacings and sizes of roofs. For 2-foot spacing between rows of o 700' 3780 2520 1890
screws,multiply the total linear feet of metal times 2.7 800 4320 2880 2160
Example: your order is 1250 feet of Gulf Rib roofing. � 900 4860 3240 2430
1000 5400 _ 3600 2700
1250 x 2.7=3375 screws 1100 5840 3960 2970
Please confirm all estimates with your Gulf Coast representative when 1200 6480 4320 3240
you placed your order. IFigu�e 6 Gulf Rib_panel screw_
Codes allow re-roofing over shingles without the use of battens calculation chart
provided the roof has been checked by a licensed roofing contractor to insure levelness and pullout integrity.
Gulf Rib metal roofing can be separated from the moisture barrier by minimum,nominal 1"x3"yellow
pine battens spaced on maximum 24"centers,or according to ASCE calculations where applicable. Since
direct contact between pressure treated lumber and metal roofing must be avoided in order to prevent
potential corrosion, Gulf Coast Supply sells only untreated battens.
CAUTION: Battens must be fastened to the roof deck with minimum#6 screws at 12" on-center, or two
minimum 8d common or pneumatic nails spaced 8" on-center, or one every 4" on-center(or by applicable
calculations according to ASCE 7-98). Battens must be installed to support the entire width and length
of ridge, cave, hip,valley,and gable-end trims.
For solid decking, at least 15/32-inch structural plywood supported on rafters at a maximum of 24"on
center is required.
If care is taken, metal roofing application can be aided by pre-drilling panels, allowing screws to go
quickly and accurately into the desired spacing. Pre-drilling will work provided that pilot holes are placed
accurately in the proper locations on panels. Purlin spacing must be uniform and carefully measured.
For panel lap details,see Figure 5 on page 4.
Gulf Coast Policies
Delivery policy Delivery charges apply to all orders where delivery is requested. Please consult your Gulf Coast sales
department for details.
Sales tax All orders picked up at Gulf Coast Supply,and all orders delivered within the state of Florida,are subject to
state sales tax. Tax exemptions should be verified prior to delivery or customer pickup.
Warrantied products A 40 year warranty applies to most material*manufactured from painted coil stock,and a 25-year
warranty to Galvalume material.Ask for details.
Indemnity All prices and designs are subject to change without notice
Disclaimer While we have made every attempt at accuracy in this manual,we are not responsible for typographic,
printing,or technical errors.
Oil Canning—a repeating,wave-like appearance in the length of the panel—is a common and often unavoidable
phenomenon in metal panels like Gulf Rib roofing that have large,flat areas within the panel.It is therefore not a
defect,nor a cause for rejection.See p.3 for details on how to avoid oil-canning.
Return policy All panel orders and special order(non-stock)trims are considered the property of the customer and non-
refundable once they are manufactured. Standard trim and accessories are refundable providing they are returned in a
clean,resalable condition. For details,go to www.gulfcoastsupply.eom and click on"No Hassle Return Policy"at
bottom;of page,or call Gulf Coast Supply to ask specific questions about returns.
now, GU L F,R]B' D ETA I L MAN UA L Gulf C!66 t
SUPPLY & MANUFACTURING
Gulf Coast Gulf Rib® Roofing Panels
Fastening Schedule for Various Wind Speeds—minimum 2:12 roof pitch
Wind Speed Zone
130 MPH 140 MPH 150 MPH 160 MPH
Roof Fastener Fastener Size Attaching to; On Center On Center On Center On Center
Zone Type Spacing Spacing Spacing Spacing
Woodgrip® min.15132 24" 24" 24" 24"
Zone 1 or #9-15 x 1'/Z e l Type l T e l e l
WoodZac® ,plywoodT yP yP yP Type
Woodgrip® min. 15/32 24" 24" 24" 24"
Zone 2 Wood7ac® #9-15 x 1% plywood Type 1 Type 1 Type 1 Type 2
Woodgrip® min. 15/32 24" .24" 24" 24"
Zone 3 Wo or dT�c® #9-15 x 1'/Z plywood Type 2 Type 2 Type 2 Type 2
Fastener pattern Fastener pattern
Type 1 Fastener patterns Type 1 and Type
2 are shown at left, row spacings are
Type 2 shown in the table above,and roof
zones are displayed on left below.
Figure 7 shows a simple illustration of
Zone 2 a the patterns. Note that fastener pattern
Eave Type 2 is required at top, bottom, and
a end laps of each panel,as well as in
additional areas according to which
roof zone the fasteners fall in.
Each"zone"of the roof has its own
............................ ........................................
screw requirements Dimension a is
______t_ a defined as 10%of the minimum width
----------------Ridge------- o
of the building,or 40/o of the mean
• .••••••••••••........................••• height of the roof,whichever is
Gable smaller; however,a cannot be less
Zone 1 than either 4%of the minimum width
of the building,or 3 feet.
... ........................................................
Eave Ridge
Zone 3 s
e,ter �
Figure 7 Screws should be placed on both sides of the ribs at both eave and ridge, Save
and on the overlap side of any panel laps.
: : : . .
� ii �y
GULFRIB' DETAIL MANUAL GuIfC6ast
SUPPLY & MANUFACTURING
Eave Drip
& Fascia
I
- FHA Style ED-3 Style 2
Eave drip Eave drip :
7/16'
I.—b—►f R
-f For custom eave drip, specify the
Eave drip
Eave drip with fascia and inside closure � amount of the eave that will be
covered(dimension"a"), and, for
Figure 8 Eave drip and fascia give a finished look along the drip
eave of the house, as well as providing protection for the steeper roofs, specify pitch . If
materials they cover.The eave drip should completely cover the Fascia a fascia is desired,be sure that the
top edge of the fascia. Inside closures,which seal off the open dimension you order will be
ribs of the panels,are optional. -►i b 14— hidden by the eave drip.
Summary of Stock Trims and Flashings
item special order information
Ridge caps (RC-2) specify pitch if less than 3/12 or greater than 6/12. Also available in
larger widths. Closures recommended.
Eave drip(FHA,ED-3 2 common styles. FHA style is pre-pitched for 3/12 to 6/12 roofs. For
appearance or ease of application,order by either specific pitch or as
gable trim(901).
i
Gable flashings Residential(EF-1),large(GR-2),and small(GR-1)rakes available.Use
butyl sealant between rake and panel.
Valleys(PV 1) specify pitch if greater than 7/12. Seal with universal foam closure
material. Open-hemmed valleys (PV 2) aid water-tightness.
Sidewall(SW-1) Use butyl sealant between sidewall flashing and panel.
Endwall(EW 1) Specify pitch if greater than 5/12. Seal with outside closures.
Transition flashing Specify pitches of both roofs. Seal lower slope using outside closures and,
if desired,inside closures on upper slope.
t
:: : i . . I
i
/ u`
GULF RIB` DETAILMANVALGuIfCdd t
SUPPLY & MANUFACTURING
Ridge Cap Opi.
The Ridge Cap is used to seal the point at
which two upward slopes meet. This can
be both along the ridge ofthe roof as well
as a covering for a hip. Either woodgrip
or self-drilling lap TEK screws are
applied through the ribs of the metal.
Since debris, insects, and blowing
rain can find easy access under the ridge
cap, closures are required to either
completely or partially seal the opening. FqY y i
Closures under ridge caps come in 3 1
types: solid,vented,and'hip tape. Figure 9 Ridge cap showing outside closure(left)and profile vent
Solid closures ("Outside Closures") are (right).
the same width as the panels. They lock together in a row placed directly
under the screws that attach the ridge cap,and form a solid,water-tight, I
air-tight barrier.
Profile Vent® comes in 50 foot rolls, is 3 inches wide, and forms a water-
retardant, insect resistant barrier that allows hot air to escape from the
attic,and is superior to many more elaborate and expensive vent systems.
Any length maybe ordered
Hip closure tape(Peel and Seal')is a sticky,adhesive-backed metallic tape
that seals the hip roof. It is 6 inches wide and comes in 33'/2 foot rolls.
Because it must be conformed to the rise and fall of the panel ridges,
approximately 10% extra may be needed beyond the length of the lip
being covered.
Figure 10 Pipe Boots provide a
Outside 6„ Profile Vents water-tight seal around roof
closure or Versa-Vents vents and come in a variety of
sizes. They seal with caulk and
conform to the shape of the
panel ribs.
*-_Lap or 2'/z" dgrip _______►
screw required
RC-2 Standard 12-inch Ridge Caps
are strong,economical and adequate for most of your roofing needs
a�
6"
\ RC-2 style over-sized ridge caps
are available with 18-inch coverage,or as a custom t71in
RC-1 style 12-inch Ridge Caps item in total widths(2 times'V')of 14-, 16-, 18-,20-,
are also available in custom widths 22-,and 24-inch
: : : • 1 • . • • • •
GULF RIB` DEIA It MANUALG61iCai�
SUPPLY & MANUFACTURING
End-wall Flashing
i
End-wall flashing is applied where the upward
slope of a roof meets a wall. The wall side of
the flashing can be covered with siding or
\\ counter-flashing, and outside closures are
necessary to seal
-�caulk(Solar Sealo between t h e
\ recommended)
flashing and the
caulk edge(order EW-IC)
�. 3n (used if endwall not panel.Roof slope
covered by siding) s h o u l d be
/.�31 II mentioned if roof
12 exceeds 5/12
pitch.
Figure 11 As with the ridge cap, the ENDWALL
FLASHING above is sealed using outside closures. pan�l�
EW-1 Stepped
Use EW-2 hemmed endwall when comering endwalls with sidewall b Endwall EW-2 Hemmed
flashing,such as with dormers or chimneys. b Endwall
For custom end-walls, .speck roofpitch and dimensions"a"and"b". � �a�►t � �a a=41/2"
b=3"
Transition Flashing Ooo.
The TRANSITION FLASHING prevents
.�i9
leakage at the point where two different roof ! ti
pitches meet. It must be sealed on the lower
side with outside closures,and can be sealed
underneath the upper panels with inside
closures. The similar GAMBREL '
FLASHING is used where the lower pitch is
steeper than the upper.
TF-1 Transition Flashing
closure s-61�2„ •
Figure 12 The transition flashing
(above) and the GF-1 gambrel
flashing (right) provide a
For custom transition flashing specify the pitches continuous drainage where two
of the two roof slopes and,if necessary,dimensions slopes meet. Both seal with
"a"and"b". outside closures on the lower side.
: : : . . 1
® Gulfcodft
SUPPLY & MANUFACTURING
Gable Flashing
„ \
Butyl tape
3/4"
EF 1 style i16"
Custom trim—specify a custom
length for a or b.
Standard dimensions a=3"
tew of EP-1 gable trim(fascia board reaore
b=3" Figure 13 Gable flashing is used to trim the edge of the
GR-1 style roofing panel at the gable end of the roof. It should match
Custom trim—specify a custom fi the eave drip that extends along the drip edge of the roof. If
length for a or b. b the panel is allowed to hang over the gable end,eave drip
can be used instead. Butyl tape between the trim and
Standard dimensions a=2118 panel eliminates leaks.
b=23i8n
® Side-wall Flashing
® caulk(Solar SeaP recommended)
caulk edge(order SW-9C)
_ (used if sidewall not
` covered by siding)
_.� 3 .
_3 Butyl tape
( ; 3/4"
s" I
Ve"i o standardsidewallf'trim
Figure 14 Sidewall flashing is applied when the side of the SW-1
roof butts up against an adjacent wall. The wall-side of the
flashing can either be covered over with siding or sealed Custom trimspecify a custom
with caulk(order SW-1C). Butyl tape should be applied length for a or b. 1 ��
where the"foot"of the flashing attaches to the roof. Standard dimensions — a=3"
b=3"
: : : . .
G614Coz�
SUPPLY & MANUFACTURING
Preformed
Valley
Install panels 2 to 4"
from diverter y
y _ panel
o
2' to 9
o
PV-1 style a
PV-2 style
Two basic styles of valley are available.
For custom valleys, specify dimension"a"
Figure 15 Pre-formed valleys use a diverterto prevent water
from rushing under panels on the opposite side, while
meanwhile channeling water off the roof. Expanding foam
closures are often used to assure a good seal.
Gulf Coast Gulf Rib® Siding
GRVR---eCornerp. 13
Drip Cap
( . 14)
Sliding
Door
ide Corner
Gutter
J-Channel
--(p 14), TC-1 Track/
ase Drip Coer(p,.41�5)
' (p. 14)
Figure 16 Common trims associated with Gulf Rib roofing panels
GUIX66 t
SUPPLY & MANUFACTURING
GR-2 Outside Corner
The GR-2 Rake and Corner can be used as a
gable trim or a comer for metal-sided buildings. _ ---`
As an alternative, the smaller EF-1 or the GR-1
(both on p.11 can also used as gable rakes and the 1
PC-5(below)or the GR-1 as corners. r
Customizing rakes or corners is often necessary
due to their landing on a panel rib. Both the GR-2
and the IS-2 can be ordered as custom trim items
by specifying custom dimensions "a"or"b". Be 1 I
sure to take into account the 3/a""head space"when !f
figuring custom dimensions.
�3' The PC-5 flat corner !+
-- -pallet
works best on smaller
3" \' structures,and where Figure 17 When used as corner trim,the GR-2 straddles the ribs
Igo xthe panels are running of the panels where they meet at the corner of the building. The
outside horizontally. It can be Gulf Rib outside corner also serves as a gable rake(see below).
1c"losure sealed with outside The inside corner (IS-2) has similar dimensions but with a
closures. reverse middle bend.
PC-5
GR-2 Gable Rake
6"
�4 sis'
� 3�4n
4 518"
�-a� i
G R-2 b
IS-2
Figure 18 When used as a gable rake,the GR-2 runs parallel to the ribs of a—►�
the roof panel, and is attached with screws running through the ribs of
upright siding. As with the EF-1 residential rake, the roof side can be
sealed with butyl sealant.
: : : 1 www.GulfCoastSupply.com
ENCLGULF RJ:B' ' ETAI L MAN UAL Gu1fC6ast®
SUPPLY & MANUFACTURING
Drip Cap and
�___--- ! J-Channel
DC-1
Drip cap►
drip cap
2V,. j —
1 I
- j=ch_ annel *1Y6 ,�
capping the panel end
E -
:� JC-1
J-channel
Figure 19 The drip cap is commonly used to trim out the bottoms of panels
over doorways and windows,and occasionally takes the place of base drip.
J-channel is used to cap raw panel edges where run-off is not a problem,and Rpariel 7/8"
is most commonly used to trim around the bottom,sides,and occasionally the
top of windows and doors,and also to cap the top sides of skirting.
capping the panel edge
Base Drip 001-
_7-7
r718�-
,.-
Base drip
1%a°
Figure 20 Base drip seals off the bottoms of panels at the floor level,where
it helps to prevent the entrance of rodents and insects,as well as a base for
the setting of panels.
:: : 1www.GulfCoastSupply.com
I/
GUILFRIB- DETAlL MANUAL
7 .41 GuIfCo6ft
SUPPLY & MANUFACTURING
Gutters ®
Gulf Coast Supply produces 29-, 26-, and 24-
gauge gutters in either 5-or 6-inch widths(depth is
approximately equal to width). All gutters
should be ordered specific to the pitch of the
roof. Downspouts are available in Yx4" (for 5-
inch gutters)and 4"x4" (for larger gutters). End
caps should be ordered at the same time as the
gutters to assure a custom fit. Special hangers fit
into the panel rib and under the gutter lip. Panels
should extend no more than V to 1'V? inches
beyond the eave on which gutters are planned.
,1 lap screws ane`- Figure 29 Exposed view of gutter showing gutter hanger
�-5 or 6n placement, downspouts, and end caps. Hangers employ lap
,
screws,and end caps are best attached with rivets.
..
Gutter hangers fit inside
panel rib and under lip o .Outer <- Inner - Outer - Inner Oute.
of gutter(apply at least -
one ler panel)and are Inner and outer gutter sections(marked`I"and"O')
attached with lap screws alternate along the eave to assure ease of application and
or rivets. gutter appearance.
Downspout Downspouts in excess of 10 feet in length must
be made in 2 sections.
t Track Covers
j Door
i - header
3%!Ii CL sliding door
Jr- - track cover
21�21
�s
511
Figure 22 Sliding door track covers fit over the door track and Door
under the panels to hide the track,assure a neat appearance,and
shed water over the door.
: : : www.GulfCoastSupply.com15
GULF-RIB` DETAIL MAN UAL G'00�
UIX66 t
SUPPLY & MANUFACTURING
f �l
40
i
Wall flashing Transition&gambrel
Ridge caps(pg.9) Eave drip(pg.9) Valleys(pg. 12) Gable rakes(pg. 11) ( gs. 10- 1I) flashings (pg. 10)
L 7-�-
4 3'
Door&window a -- Reflective bubble
Comer trims(pg. 13) trims(pg. 14) Base drip(pg. 14) Pipe Boot(pg. 11) Electrical Boot insulation
Inside Closures ' + �
4W' AhS
Exppanding
Outside Closures Flex-o-vent Profile Vent hoam Peel and Seal Touch-up Paint
S/D TEK�p TEK
v
Butyl Tape Titebond! Woodgrip' Screws TEK screws WoodZac'r screws WoodMace screws
Guide to Misc. Accessories
item application
pipe boot Fits over vent and heat pipes. Available also in heat-resistant boots.
electrical boot - _Fits around pipes with inaccessible tops (such as weatherheads).
outside closures Required to seal under ridge caps and transition and endwall flashings.
inside closures Seals under panels,particularly on the cave.
Profile Vent,Flex-o-Venn'Vented closure material surpassing many other venting systems.
expanding foam Compressed adhesive foam expands to seal between valleys and panels.
Peel and Seal' — Seals hips under hip caps. Also, a general purpose sealing tape (6" wide).
touch-up paint - Hides scratches and mars encountered in installation.Over 20 colors.
butyl tape General purpose low-cost sealant, used on panel laps and under trim.
Titebond® _ __ _ _ __ =A superior general pu_r_pose caulk for all joints.-Matches-panel colors.
Low profile insulation Greatly reduces radiant heat when installed under panels.
Woodgrip�screws Used in all applications attaching metal to wood. 1", 1'/Z", 2'/2" sizes.
- — -- -- --Used - --g - --- --- p d. ", -
TEK screws Self-drilling TEK screws for metal urlins. La TEK screws draw
together joints and attach trim.
ZAC®screws "Lifetime"screws; 1'/x", 2%",threaded.for wood; self-drilling available.
Version 01-26-16
See www.gulfcoastsupply.com