HomeMy WebLinkAboutCompaction test0
i
7 7.�:
Soil Nuclear Gauge
APR 12 2012 Report Date: 3/20/2017
' NAT�aPv PERMITTING Test Method: ASTM D 6938
Port St. Lucie St. Lucie County, FL
FBPE CA # 4930
521 NW Enterprise Drive
Port St Lucie, FL 34986
Phone: 772-924-3575 1 Fax: 772-924-3580
Client:
GHO Homes Corporation
590 NW Mercantile Place
Port St. Lucie, FL 34986
File Copy
Project:
15-0338.00
Meadowood Golf & Country Club
Fort Pierce, Florida
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
M
Maximum
Dry Density
(pcf)
In Place
Moisture
M
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
M
Remark
37
3/17/17
P-3
N/A
11.2
113.3
7.5
110.6
12
98
95 / 105
Pass
38
3/10/17
P-3
N/A
11.2
113.3
6.8
112.1
12
99
95 / 105
Pass
39
3/10/17
P-3
N/A
11.2
113.3
6.9
112.3
12
99
95 / 105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN
Field Technician
37
Below Slab Grade: Lot 282, foundation pad, center
0-1
Troxler 3430 25093
Smith, Johnnie
38
Below Slab Grade: Lot 282, foundation pad, northwest corner
0-1
Troxler 3430 25093
Smith, Johnnie
39
Below Slab Grade: Lot 282, foundation pad, southeast corner
0-1
Troxler 3430 25093
Smith, Johnnie
Remarks
Comments
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
33 1 16..J ei n+ —Pi i-% ej Z) 1" -
m14 --�4 1 -70 i 06-18
W
03%20/2�17
P.E.
ofe oATLEr��Lleer (j 75
��®,(9""eAf Florida Q, e
0 1 O , \e
ON ee
E°
AL �
J118111111110®®
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1