HomeMy WebLinkAboutNotice of Acceptance a
MIAMI��� � MiAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) ` ww.iiii�"'i`1.1(1e.gov/ee°"°"'"
CertainTeed Corporation
'18 Moores Road
Malvern,PA 19355
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miatni-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the,use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decics.
LABELING: Each unit shall hear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
- TERMINATION of this NOA will-occur_after-the_expiration-date_or._if_there-has_been:a.revision_or_change-in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#14-0224.03 and consists of pages I through 42.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 14-0529.02
MIAMI-DAD,COuNTY 5 I2(' Expiration Date: 06/19/18
Approval Date: 09/24/15
C ) Page 1 of 42
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Category: Modified Bitumen
Material: APP/SBS
Deck Tyne: Wood
Maximum Design Pressure: -127.5 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
IAll Weather/Empire Base 39 3/s"x 65'10"; ASTM D 4601,Type Asphalt coated,fiberglass reinforced
!Sheet . Roll weight: 70-dbs. II base sheet.
(2 squares) UL Type G2
Flexiglas Base Sheet 39 3/s"x 98'9';Roll ASTM D 4601,Type Modified Bitumen coated fiberglass
weight: 90 lbs. lI base sheet.
(3 squares) UL Type G2
Flintlastic Base 20 ' 39 3/8 x 49' 6';Roll ASTM D 6163, Modified Bitumen coated fiberglass
weight: 90 lbs. Grade S,Type I base sheet.
(1.5 squares)
Flintglas Ply Sheet Type IV 39 3/s"x 164'7';Roll ASTM D 2178, Type Fiberglass,asplialt impregnated ply sheet.
weight: 38 lbs. IV
(5 squares) UL Type G 1
Flintglas Premium Ply Sheet 39 3/8"x 164'7';Roll ASTM D 2178,Type Fiberglass, asphalt impregnated ply
Type VI weight: 40 lbs. VI sheet.
(5 squares) UL Type G1
Flintlastic STA 39 3/s"x 32' 10";Roll ASTM D 6222, Smooth surfaced APP Modified
weight: 87 lbs. Grade S,Type I Bitumen membrane with non-woven
_ — (1 square) polyester mat reinforcement for torch
application.
Flintlastic GTA ,___ .______39_3/s_x_32_I.0_';_RoIL_____ASTM_D_6222,___Granule-sur.faced-AP_P_1Vlodified-
__ weight: 105 lbs. Grade G,Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for torch
1 application.
1 Flintlastic GTA-FR 39 3/s"x 32' 1.0'; Roll ASTM D 6222, Granule surfaced APP Modified
weight: 105 lbs. Grade G,Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for torch
application.
Flintlastic GMS 39 3/8"x 32' 10'; Roll ASTM D 6164, Granule surfaced SBS Modified
weight: 94 lbs. Grade G,Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for mop
application.
I
NOA No.: 14-0529.02.
MIAMI•DADE COUNTY
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 2 of 42
I
i
z.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Flintlastic Premium GMS 391/8"x 32' 10";Roll ASTM.D 6164, Granule surfaced SBS Modified
f weight: 101 lbs. Grade G, Type II Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for mop
application.
i Flintlastic FR-P 39 3/8"x 32' 10";Roll ASTM D 6164, Fire resistant, granule surfaced SBS
weight: 101 lbs. Grade G,Type I Modified Bitumen Membrane with
(1 square) non-woven polyester mat
i
reinforcement for mop application.
Flintlastic Premium FR-P 39 3/s"x 32' 10";-Roll ASTM D 6164, Fire resistant,granule surfaced SBS
weight: 101 lbs. Grade G, Type 11 Modified Bitumen Membrane with
(1 square) non-woven polyester mat
reinforcement for mop application.
Flintlastic FR Dual Cap 39 s/s"x 32' 10";Roll ASTM D 6162, Granule surfaced SBS modified
weight: 103 lbs. Grade G, Type I bitumen membrane with a nonwoven
(1 square) polyester/fiberglass composite mat
reinforcement for use in cold or mop
applications.
Flintlastic FR Cap 30 39 3/8"x 32' 10" Roll ASTM D 6163, Fire resistant, granule surfaced SBS
weight: 86 lbs. Grade G,Type I Modified Bitumen membrane with
(1 square) fiberglass mat reinforcement for mop
applications.
Flintlastic FR Cap 30 T 39-3/8"x 32' 10';Roll ASTM D 6163, Granule surfaced SBS Modified
weight: 1.00 lbs. Grade G,Type I Bitumen membrane with fiberglass
(1 square) mat reinforcement for torch
application.
Flintlastic Base 20 T 39-3/8"x 33';Roll ASTM D 6163, Modified Bitumen, coated fiberglass
Weight: 81 lbs. Grade S,Type I base sheet for torch application.
(]-square)--- - — - ---
Flintlastic FR Cap 30 CoolStar 39 3/8"x 32' 10";Roll ASTM D 6163, Fire resistant,granule surfaced SBS
weight: 88 lbs. Grade G, Type I Modified Bitumen membrane with
(1 square) fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
Flintlastic FR Cap 30 T 39 3/8"x 32' 10";Roll ASTM D 6163, Fire resistant, granule surfaced SBS
CoolStar weight: 102 lbs. Grade G,Type I Modified Bitumen membrane with
(1 square) fiberglass mat reinforcement for mop
applications. Covered with reflective
CoolStar Coating.
NOA No.: 14-0529.02
MIAMI•DADE COUNTY
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 3 of 42
j �
I
i
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Descrintion
Flintlastic GTA CoolStar 39 3/8"x 32' 10";Roll ASTM D 6222, Granule surfaced APP Modified
weight: 106 lbs. Grade G,Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for torch
application. Covered with reflective
CoolStar Coating.
I Flintlastic GTA-FR CoolStar 39 3/8"x 32' 10";Roll ASTM D 6222, Granule surfaced APP Modified
weight: 1061bs. Grade G, Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for torch
application. Covered with reflective
i CoolStar Coating.
Flintlastic GMS CoolStar 39 3/8"x 32' 10";Roll ASTM D 6164, Granule surfaced SBS Modified
weight: 97 lbs. Grade G,Type I Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for mop
application. Covered with reflective
CoolStar Coating.
Flintlastic Premium GMS 39 3/8"x 32' 10";Roll ASTM D 6164, Granule surfaced SBS Modified
CoolStar weight:103 lbs. Grade G, Type I1 Bitumen membrane with non-woven
(1 square) polyester mat reinforcement for mop
application. Covered with reflective
CoolStar Coating.
Flintlastic FR-P CoolStar 39 3/8" x 32' 10";Roll ASTM D 6164, Fire resistant,granule surfaced SBS
weight: 103 lbs. Grade G, Type I Modified Bitumen Membrane with
(1 square) non-woven polyester mat
j reinforcement for mop application.
Covered with_reflective CoolStar
Coating.
Flintlastic Premium FR-P 39 3/8"x 32' 10"; Roll ASTM D 6164, Fire resistant,granule surfaced SBS
CoolStar weight: 103 lbs. Grade G, Type 11 Modified Bitumen Membrane with
(1 square) non-woven polyester mat----
reinforcement for mop application.
Covered with reflective CoolStar
Coating.
Flintlastic Ultra Poly SMS 39 3/8"x 32' 10';Roll ASTM D 6164, Smooth surfaced SBS Modified
Base Sheet weight: 90 lbs. (1 Grade S,Type I Bitumen Membrane with non-woven
squares) polyester mat reinforcement for mop
applications.
Glasbase Base Sheet 36" x 98' 9";Roll ASTM D 4601, Type Asphalt coated,fiberglass base sheet.
weight: 75 lbs. 1I,
(3 squares) UL Type G2
MIAMI•DADE COUNTY NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 4 of 42
i
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Flintlastic Poly SMS Base 39 3/8"x 64'3";Roll ASTM D 4601, Modified Bitumen coated polyester
Sheet weight: 90 lbs. Grade S,Type II base sheet.
(2 squares) UL Type G2
Yosemite Venting Base Sheet 39 3/8" x 32'l0';Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced
weight: 85 lbs. ASTM D 4897,Type buffer sheet.
(i square) lI
UL Type G3
Flintlastic APP Base T 39 3/8"x 65' 4';Roll ASTM D 6509 Modified Bitumen coated fiberglass
weight: 100 lbs. base sheet.
(2 squares)
Flintlastic Ultra Glass SA 39 3/s"x 33'11';Roll ASTM D 1970 Self--adhering,fiberglass reinforced,
weight: 73 lbs. SBS modified bitumen base/ply sheet.
(1 square)
Black Diamoriffm Base Sheet 36" x 68'7';Roll ASTM D 1970 Self-adhering fiberglass reinforced
weight: 78 lbs. modified bitumen base sheet
(2 squares)
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
(With Current NOA)
FlintBoard iSO Polyisocyanurate foam insulation CertainTeed Corporation
FlintBoardH ISO Polyisocyanurate foam insulation CertainTeed Corp.
ACFoam-11 Polyisocyanurate foam insulation Atlas Roofing Corp.
High Density Wood Fiberboard Wood fiber insulation board Generic
Perlite Insulation Perlite insulation board Generic
DensDeck, DensDeck Prime Water resistant gypsum board Georgia Pacific Gypsum LLC
H-Shield Polyisocyanurate foam insulation Hunter Panels LLC
ENRGY 3 Polyisocyanurate foam insulation Johns Manville Corp.
ENRGY 3 25 PSI Polyisocyanurate foam insulation Johns Manville Corp.
Multi-Max FA-3 Polyisocyanurate foam insulation RMax Operating, LLC
i SECUROCK Gypsum-Fiber Roof Board homogenous fiber reinforced USG Corp.
NOA No.: 14-0529.02
MIAMI•DADE COUNTY
Expiration Date: 06/19/18
Approval Datc: 09/24/15
Page 5 of 42
i
(
APPROVED FASTENERS:
TABLE 3
Manufacturer
Fastener Product Product
Number Name Description Dimensions (With Current NOA)
1. Trufast#12 DP Fastener Insulation fastener for wood various Altenloh,Brinch &Co.U.S.,
and steel decks Inc.
2. Trufast 3"Metal Galvalume steel plate 3"round Altenloh,Brinch &Co.U.S.,
Insulation Plate Inc.
3. FlintFast#12 Coated,carbon steel screw various CertainTeed Corp.
4. FlintFast 3"Insulation Galvalume AZ50 steel plate 3" round CertainTeed Corp.
Plate
5. FlintFast#14 Insulation fastener for wood various CertainTeed Corp..
and steel decks
6. Simplex MAXX Cap Polymer fastnel 1" long Simplex Nails,Inc.
7. OMG#12 Standard Insulation fastener for wood various OMG,Inc.
Roofgrip and steel.
8. OMG 3"Galvanized Steel Galvalume stress plate 3"round OMG,Inc.
Plates
9. Trufast#14 HD Fastener Insulation fastener for wood various Altenloh,Brinch &Co.U.S.,
and steel decks Inc.
10. OMG Heavy Duty' Insulation and membrane Various OMG, Inc.
fastener
H. OMG 3 in.Round Metal Galvalume AZ50 steel plate 3" round OMG,Inc.
Plates
12. AccutTrac Hextra Carbon steel fastener Various OMG,Inc.
13. AccuTrac Plates Galvalume stress plate. 3"square OMG,Inc.
14. AccuTrac Flat Bottom A2-SS aluminized steel plate 3"square OMG,Inc.
Plates
NOA No.: 14-0529.02
MIAMI•DADE COUNTY
i Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 6 of 42
,APPROVED SURFACING/COATING OPTIONS:
TABU 4
Chosen components must be applied according to manufacturer's application instructions.Any coating,listed
below,used as a surfacing,must be listed within a current NOA.
r ,
I System Number Manufacturer Application
l. Generic Gravel applied at 400 lbs/sq.,adhered with flood coat of asphalt at
60 lbs/sq.
2. Generic Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60
lbs/sq.
3. Karnak Corp. Karnak(#97 AF)Fibrated Aluminum Roof Coating applied at an
I application rate of 1.5 gal/sq.
j 4. CertainTeed-Corp. FlintCoat A-150 applied at an application rate of 1.5 gal/sq.
5. Gardner Asphalt Corp. APOC#212 Fibered Aluminum Roof Coating applied at an
application rate of 1.5 gal/sq.
6. Gardner Asphalt Corp. APOC#400 Sunbrite applied at an application rate of 3 gal./sq.
i
MIAMI•DADE COUNTY NOA No.: 14-0529.02
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 7 of 42
f
EVIDENCE SUBMITTED:
Test Agency/Identifier Name Report Date
Factory Mutual Research Corp. FM 4470 3Y8A7.AM 03/23/96
FM 4470 OD3A3.AM 04/04/97
FM 4470 2DOAO.AM 12/23/98
FM 4470 1D7A4.AM 1 1/09/98
FM 4470 3039046 06/15/10
FM 4470 3048520 09/19/13
Underwriters Laboratories,Inc. UL 790 R11656 01/11/13
United States Testing Company ASTM D 5147 97457-4 06/03/88
ASTM D 5147 97-457-2R 12/02/87
Momentum Technologies;Inc. ASTM D 4601 AX31 G81) 09/05/08
ASTM D6164 AX31 G8F 06/05/09
ASTM D6222 AX31 G8G 06/05/09
ASTM D 3909/D 4897 AX3 I G8C 09/05/08
TrinityjERD TAS 114(J) 3504.06.01-1 06/05/01
TAS 114(J) 3507.08.99-1 04/18/01
TAS 117(B) 3503.10.06 10/10/06
TAS 117(B) 06490.04.07-R 1 06/27/07
TAS H 4(H) Letter 04/05/06
TAS 114 3533.01.06 01/06/06
TAS 114 3521.07.04 07/29/04
TAS 117 (B)/ASTM D 6862 C8500SC.11.07 1 1/30/07
TAS 114 C8370.08.08 08/19/08
ASTM Physical Properties C10080.09.08-R4 03/25/10
ASTM D6164/D4798 C31410.01.11-2 01/10/1.1
ASTM D4601 C40050.09.12-1 09/28/12
ASTM D1970 C40050.09.12-2 09/28/12
ASTM D5147ID4798 C31410.10.10-R 1 1 1/01/12
ASTMD51.471D4798 C31410.0.1.11-1-R1 11/01/12
ASTM D1876 C35460.05.11 06/16/11
ASTM-DI-876,TAS-114(H),- C42.1-1-0.08.12 08/13/12
TAS 117 (B)
FM 4474/TAS 114 C39670.08.12 08/20/12
TAS 117B C35500.02.11 02/09/11
ASTM D4798 C31.410.01.11-2A-R 1 02/21/13
ASTM D4798 C31410.12.13 12/05/13
ASTM D6222 C40050.12.13-R1 12/31/13
TAS 117,TAS 114 C30310.12.09-R1 03/07/14
ASTM D1876,TAS 114 (H), C45620.03.14 03/27/14
FM 4474
ASTM D 1876,TAS 114(H), C47320.03.14-R 1 04/01/15
FM 4474
PRI Construction Materials ASTM D6163 CTC-032-02-01 01/22/08
Technologies LLC ASTM D6163 CTC-066-02-01 08/09/11
ASTM D6222 CTC-070-02-01 08/09/11
NOA No.: 14-0529.02
MIAMI•DADE COUNTY
,..., , Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 8 of 42
EVIDENCE SUBMITTED:
Test Agency/Idciftifier Name Report Date
ASTM D6164/D4798 CTC-093-02-01 08/09/11
ASTM D2178 CTC-122-02-01 03/13/12
ASTM D2178 CTC-123-02-01 03/13/12
ASTM D4601 CTC-127-02-01 03/13/12
ASTM D6163 CTC-128-02-01 06/11/12
ASTM D6163 CTC-129-02-01 0.6/11/12
ASTM D6164 CTC-132-02-01 06/11/12
ASTM D6164 CTC-162-02-01 05/09/13
ASTM D6164 CTC-161-02-01 05/09/13
ASTM D6162 CTC-183-02-01 10/02/13
I
ASTM D6164 CTC-190-02-01 1.2/02/13
ASTM D 1970 CTC-199-02-01 01/22/14
i
I
i
NOA No.: 14-0529.02
MIAMI-DADE COUNTY
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 9 of 42
Membrane Type: APP Modified
Deck Type 1I: Wood,Non-Insulated
Deck Description: 19/32" or'greater plywood or wood plank
System Type E(3): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of All Weather/Empire Base Sheet,Yosemite Venting Base Sheet,Flexiglas Base
Sheet,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base
Sheet orFlintglas Premium Ply Sheet Type VI mechanically attached as detailed below.
Fastening:. Base sheet shall be lapped 4" and fastened with 11. ga. annular ring shank nails and approved tin
caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c.
Ply Sheet: One ply of All Weather/Empire Base Sheet,Flintlastic Ultra Poly SMS Base Sheet, Glasbase
(Optional) Base Sheet,Flexiglas Base Sheet,Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one
or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in
a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic
STA or Flintlastic APP Base T torch adhered.
Membrane.; Flintlastic:;)Flintlastic GTA CoolStar,Flintlastic GTA-FR or Flintlastic GTA-FR CoolStar
tore a sereo base/ply sheet.
Surfacing: Any of the approved surfacing/coating options listed in Table 4.
(Optional)
Maximum Design -52.5 psf.(See General Limitation#7)
Pressure:
NOA No.: 14-0529.02
MIAMI•DADE COUNTY
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 23 of 42
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
i3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4'x 4' ]llaxnllurn.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asplialt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of-45 psE
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lb£,as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested,are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or nlenlbrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer,Registered Architect, or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA,General Limitation#9 will not be applicable.)
8. All attachment and sizingof perimeter hailers,-metal profile,and/or flashing termination designs shall-conform to
Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,
perimeters, and corners).Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones(i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA,General Limitation#7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 14-0529.02
CMIAMIff-DMADE COUNTY
Expiration Date: 06/19/18
Approval Date: 09/24/15
Page 42 of 42