HomeMy WebLinkAboutProduct approvals, double doors (2) le Online Pa e 1 of 3
Fate C-6
i
-77
MY,
Log In i User Registration �Hot Topics i Submit Surcharge Stats&Facts i Publications ; FBC Staff ? BCIS Site Map Links i Search i
Product Approval
USER:Public User
)oroval Menu>Product or Application Search>Application List>Application Detail
FL15037-R2
Lion Type Revision
ersion 2014
Lion Status Approved
I
:nts
d
Manufacturer Therma-Tru Corporation
i/Phone/Email 118 Industrial Drive
Edgerton,OH 43517
(419) 298-1740
rickw@rwbldgconsultants.com
zed Signature' Vivian Wright
rickw@rwbldgconsultants.com
:al Representative-
3/Phone/Email
Assurance Representative
i/Phone/Email
ry Exterior Doors
!gory Swinging Exterior Door Assemblies
ante Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Wi Evaluation Report-Hardcopy Received
Engineer or Architect Name who developed Lyndon F.Schmidt,P.E.
luation Report
License PE-43409
Assurance Entity National Accreditation and Management Institute
Assurance Contract Expiration Date 12/31/2018
ad By Ryan J. King,P.E.
Ci Validation Checklist-Hardcopy Received
ate of Independence_ FL15037 R2 COI Certificate Of Indeoendence.odf
iced Standard and Year(of Standard) Standard Year
AAMA/W D MA/CSA 101/I.S.2/A440 2005
ASTM E1886 2002
ASTM E1886 2005
ASTM E1996 2002
ASTM E1996 2005
ASTM E1996 2006
ASTM E330 2002
SSTD12 1999
ence of Product Standards
d By
i
iilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquS73Fr2ZyiPg2... 3/31/2017
Building Code Online Page 2 of 3
I
Sections from the Cody
I
I
Product Approval Method Method 1 Option D
Date Submitted 05/30/2015
Date Validated 06/28/2015
Date Pending FBC Approval 07/05/2015
Date Approved 08/19/2015
ISummary of Products
FL# Model, Number or Name Description
15037.1 a.Opaque Fiberglass Door 6'8"Impact"Opaque "Fiber-Classic","Smooth-Star"or
"Classic-Craft"Single Fiberglass Door with or without
"Impact"Sidelite or Sidelites-Outswing/ Inswing (X,OX or
XO; OXO)Configurations
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15037 R2 II Inst 15037.1.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See Inst 15037.1 for Design Pressure Ratings,any FL15037 R2 AE Eval 15037.1.1)df
additional use limitations, Installation instructions and Created by Independent Third Party: Yes
product particulars. (For FiberClassic and SmoothStar doors
and sidelites,this product approval requires the use of"J"
part numbers for these doors and sidelites,which have been
stained or painted within six months of installation.)
15037.2 b. Opaque Fiberglass Door 6'8"Impact"Opaque "Fiber-Classic","Smooth-Star" or
"Classic-Craft"Double Fiberglass Door with or without
"Impact"Sidelites-Outswing/Inswing (XX or OXXO)
Configurations
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15037 R2 II Inst 15037.2.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See Inst 15037.2 fo r Design Pressure Ratings,any FL15037 R2 AE Eval 15037.2.odf
additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars. (For FiberClassic and SmoothStar doors
and sidelites,this product approval requires the use of"J"
part numbers for these doors and sidelites,which have been
stained or painted within six months of installation.)
15037.3 c.Opaque Fiberglass Door 8'0"Impact"Opaque"Fiber-Classic","Smooth-Star" or
"Classic-Craft"Single Fiberglass Door with or without
"Impact"Sidelite or Sidelites-Outswing/ Inswing (X,OX or
XO; OXO)Configurations
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15037 R2 II Inst 15037.3.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation.Reports
Other:See Inst 15037.3 fo r Design Pressure Ratings,any FL15037 R2 AE Eval 15037.3.1)df
additional use limitations,installation Instructions and Created by Independent Third Party: Yes
product particulars. (For FiberClassic and SmoothStar doors
and sidelites,this product approval requires the use of"I"
part numbers for these doors and sidelites,which have been
stained or painted within six months of installation.)
15037.41 d. Opaque Fiberglass Door 8'0"Impact"Opaque"Fiber-Classic","Smooth-Star"or
"Classic-Craft"Double Fiberglass Door with dr without
"Impact"Sidelites-Outswing/ Inswing (XX or OXXO)
Configurations
Limits of Use Installation Instructions
_ Approved for use in HVHZ: No FL15037 R2 II Inst 15037.4.od f
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See Inst 15037.4 fo r Design Pressure Ratings,any FL15037 R2 AE Eval 15037.4.1)df
additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars. (For FiberClassic and SmoothStar doors
and sidelites,this product approval requires the use of"J"
ww.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquS73Fr2ZyiPg2... 3/31/2017
R W R W Building Consultants, Inc. h _
B Consulting and Engineering Services for the Building Industry
i7 C P.O.Box 230 Valrico,.Fl.33595 Phone 813.659.9197 v
Florida Board of Professional Engineers Certificate of Authorization No.9813
Pi-odtict Evaluation /
Product-Category Sub Category Manufacturer Product Name
Swinging Therma Tru Corporation Opaque Fiberglass Double Door
_xterior 118 Industrial Drive with and w/out Sidelites
Doors Exterior Door
Assemblies. Edgerton,OH 43517 Inswingl0utswing
Phone 419.298.1740- "ImpacC
cope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F.Schmidt,P.E.for Thermal Tru
Corporation based on Rule Chapter No.61 G20-3,Method 1 D of the State of Florida Product Approval,Department of
Business&Professional Regulation.
RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in.any other entity involved in the approval process of the product named
herein..
Limitations:
1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements
excluding the"High Velocity Hurricane Zone"(HVHZ).
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the FBC and does not
require an impact resistant covering.The glazing meets missile level"D".The assembly excludes Wind Zone 4 as defined in ASTM
E1996 and Section 1609.1.2.2 of the FBC.
4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction.
5. Site conditions that deviate from the details of drawing FL-15037.4 require further engineering analysis by a licensed engineer or
registered architect.
6. See drawing FL-15037.4 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard Testing Laboratory Sinned by
CTLA 98OW SSTD 12-99 Certified Testing Laboratories Ramesh Patel,P.E.
TEL 01460274 ASTM E188611996-05 Testing Evaluation Lab.,lnc. Lyndon F.Schmidt,P.E.
TEL 01460440A ASTM E1886-05/1996-06&ASTM E330-02 Testing Evaluation Lab.,lnc. Lyndon F.Schmidt;P.E.
TEL 06-0831-1 AAMANVDMA/101/I.S.2/A440-05 Testing Evaluation Lab.,lnc. Wendell W,Haney,P.E.
ASTM E1885/1996-02
2. Miami Dade NOA Materials Testing
13-0129.27 DuPont Butacite°PVB Interlayer
14-0423.17 Saflex Interlayer(Eastman Chemical Company)
3. 3rawinq No. Prepared by Signed&Sealed by
4o.FL-15037.4 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E.
4. :alculations Prepared by Signed&Sealed by
nchoring RW Building Consultants,inc.'(CA#9813) Lyndon F.Schmidt,P.E.
5.. 2uality Assurance
:ertificate of Participation issued1by,yNational Accreditation and Management Institute,certifying,,
chat Therma Tru Corporation is manufacturing products within a quality assurance 'bi ji:iat.F
:omplies with ISO/IEC 17020 and Guide 53.
Z1-7
' z1_yndon F.Schmidt,P.E.
FL PE No.43409
z• _._ _ 1/23/2015
Sheet 1 of 1