Loading...
HomeMy WebLinkAboutProduct approvals, double doors (2) le Online Pa e 1 of 3 Fate C-6 i -77 MY, Log In i User Registration �Hot Topics i Submit Surcharge Stats&Facts i Publications ; FBC Staff ? BCIS Site Map Links i Search i Product Approval USER:Public User )oroval Menu>Product or Application Search>Application List>Application Detail FL15037-R2 Lion Type Revision ersion 2014 Lion Status Approved I :nts d Manufacturer Therma-Tru Corporation i/Phone/Email 118 Industrial Drive Edgerton,OH 43517 (419) 298-1740 rickw@rwbldgconsultants.com zed Signature' Vivian Wright rickw@rwbldgconsultants.com :al Representative- 3/Phone/Email Assurance Representative i/Phone/Email ry Exterior Doors !gory Swinging Exterior Door Assemblies ante Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Wi Evaluation Report-Hardcopy Received Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. luation Report License PE-43409 Assurance Entity National Accreditation and Management Institute Assurance Contract Expiration Date 12/31/2018 ad By Ryan J. King,P.E. Ci Validation Checklist-Hardcopy Received ate of Independence_ FL15037 R2 COI Certificate Of Indeoendence.odf iced Standard and Year(of Standard) Standard Year AAMA/W D MA/CSA 101/I.S.2/A440 2005 ASTM E1886 2002 ASTM E1886 2005 ASTM E1996 2002 ASTM E1996 2005 ASTM E1996 2006 ASTM E330 2002 SSTD12 1999 ence of Product Standards d By i iilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquS73Fr2ZyiPg2... 3/31/2017 Building Code Online Page 2 of 3 I Sections from the Cody I I Product Approval Method Method 1 Option D Date Submitted 05/30/2015 Date Validated 06/28/2015 Date Pending FBC Approval 07/05/2015 Date Approved 08/19/2015 ISummary of Products FL# Model, Number or Name Description 15037.1 a.Opaque Fiberglass Door 6'8"Impact"Opaque "Fiber-Classic","Smooth-Star"or "Classic-Craft"Single Fiberglass Door with or without "Impact"Sidelite or Sidelites-Outswing/ Inswing (X,OX or XO; OXO)Configurations Limits of Use Installation Instructions Approved for use in HVHZ: No FL15037 R2 II Inst 15037.1.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Inst 15037.1 for Design Pressure Ratings,any FL15037 R2 AE Eval 15037.1.1)df additional use limitations, Installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors and sidelites,this product approval requires the use of"J" part numbers for these doors and sidelites,which have been stained or painted within six months of installation.) 15037.2 b. Opaque Fiberglass Door 6'8"Impact"Opaque "Fiber-Classic","Smooth-Star" or "Classic-Craft"Double Fiberglass Door with or without "Impact"Sidelites-Outswing/Inswing (XX or OXXO) Configurations Limits of Use Installation Instructions Approved for use in HVHZ: No FL15037 R2 II Inst 15037.2.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Inst 15037.2 fo r Design Pressure Ratings,any FL15037 R2 AE Eval 15037.2.odf additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors and sidelites,this product approval requires the use of"J" part numbers for these doors and sidelites,which have been stained or painted within six months of installation.) 15037.3 c.Opaque Fiberglass Door 8'0"Impact"Opaque"Fiber-Classic","Smooth-Star" or "Classic-Craft"Single Fiberglass Door with or without "Impact"Sidelite or Sidelites-Outswing/ Inswing (X,OX or XO; OXO)Configurations Limits of Use Installation Instructions Approved for use in HVHZ: No FL15037 R2 II Inst 15037.3.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation.Reports Other:See Inst 15037.3 fo r Design Pressure Ratings,any FL15037 R2 AE Eval 15037.3.1)df additional use limitations,installation Instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors and sidelites,this product approval requires the use of"I" part numbers for these doors and sidelites,which have been stained or painted within six months of installation.) 15037.41 d. Opaque Fiberglass Door 8'0"Impact"Opaque"Fiber-Classic","Smooth-Star"or "Classic-Craft"Double Fiberglass Door with dr without "Impact"Sidelites-Outswing/ Inswing (XX or OXXO) Configurations Limits of Use Installation Instructions _ Approved for use in HVHZ: No FL15037 R2 II Inst 15037.4.od f Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See Inst 15037.4 fo r Design Pressure Ratings,any FL15037 R2 AE Eval 15037.4.1)df additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors and sidelites,this product approval requires the use of"J" ww.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquS73Fr2ZyiPg2... 3/31/2017 R W R W Building Consultants, Inc. h _ B Consulting and Engineering Services for the Building Industry i7 C P.O.Box 230 Valrico,.Fl.33595 Phone 813.659.9197 v Florida Board of Professional Engineers Certificate of Authorization No.9813 Pi-odtict Evaluation / Product-Category Sub Category Manufacturer Product Name Swinging Therma Tru Corporation Opaque Fiberglass Double Door _xterior 118 Industrial Drive with and w/out Sidelites Doors Exterior Door Assemblies. Edgerton,OH 43517 Inswingl0utswing Phone 419.298.1740- "ImpacC cope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F.Schmidt,P.E.for Thermal Tru Corporation based on Rule Chapter No.61 G20-3,Method 1 D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in.any other entity involved in the approval process of the product named herein.. Limitations: 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering.The glazing meets missile level"D".The assembly excludes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.2.2 of the FBC. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15037.4 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-15037.4 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Sinned by CTLA 98OW SSTD 12-99 Certified Testing Laboratories Ramesh Patel,P.E. TEL 01460274 ASTM E188611996-05 Testing Evaluation Lab.,lnc. Lyndon F.Schmidt,P.E. TEL 01460440A ASTM E1886-05/1996-06&ASTM E330-02 Testing Evaluation Lab.,lnc. Lyndon F.Schmidt;P.E. TEL 06-0831-1 AAMANVDMA/101/I.S.2/A440-05 Testing Evaluation Lab.,lnc. Wendell W,Haney,P.E. ASTM E1885/1996-02 2. Miami Dade NOA Materials Testing 13-0129.27 DuPont Butacite°PVB Interlayer 14-0423.17 Saflex Interlayer(Eastman Chemical Company) 3. 3rawinq No. Prepared by Signed&Sealed by 4o.FL-15037.4 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. :alculations Prepared by Signed&Sealed by nchoring RW Building Consultants,inc.'(CA#9813) Lyndon F.Schmidt,P.E. 5.. 2uality Assurance :ertificate of Participation issued1by,yNational Accreditation and Management Institute,certifying,, chat Therma Tru Corporation is manufacturing products within a quality assurance 'bi ji:iat.F :omplies with ISO/IEC 17020 and Guide 53. Z1-7 ' z1_yndon F.Schmidt,P.E. FL PE No.43409 z• _._ _ 1/23/2015 Sheet 1 of 1