FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Custom Tacoma_eArtisan_MDW282 Builder Name: GHO Homes
Street: 3316 Bent Pine Dr. i Permit Office:
City,State,Zip: Ft.Pierce, FL,34951 Permit Number: 1_�01 - 0516
Owner: GHO Homes Jurisdiction:
Design Location: FL,VERO_BEACH MUNICIPAL_ARPT County:: Indian River(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2513.0 sqft.) Insulation Area
2. Single family or multiple family Single family a.Concrete Block-Int Insul, Exterior R=4.1 1767.10 ft2
b. Interior Frame-Steel, Interior R=0.0 464.33 ft2
3. Number of units,if multiple family 1 c.Frame-Steel,Adjacent R=11.0 281.56 ft2
4. Number of Bedrooms 3 d. N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (2908.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 2908.00 ft2
6. Conditioned floor area above grade(ft2) 2908 b. N/A R= ft2
Conditioned floor area below grade(ft2)' 0 c. N/A R= ft2
11.Ducts R ft2
7. Windows(330.5 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH: 1st Floor A 6 290.8
a. U-Factor: Dbl, U=0.61 172.00 ft2 b.Sup: Attic, Ret:Attic,AH: 1 st Floor B 6 290.8
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.52 96.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.22 a.Central Unit 24.0 SEER:16.00
c. U-Factor: Dbl,U=0.45 62.50 ft2 b.Central Unit 30.0 SEER:16.00
SHGC: SHGC=0.26 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a. Electric Strip Heat 24.0 COP:1.00
SHGC: b. Electric Strip Heat 30.0 COP:1.00
Area Weighted Average Overhang Depth: 7.037 ft.
Area Weighted Average SHGC: 0.243 14.Hot water systems
a. Electric Cap:50 gallons
8. Floor Types (2908.0 sqft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 2908:00 ft2 b. Conservation features
b. N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.114
Total Proposed Modified Loads: 79.99 PASS
Total Baseline Loads: 82.48 �7
1 hereby certify that the plans and specifications covered by Review of the plans and o��HE S�AZp
this calculation are in compliance with the Florida Energy specifications covered by this IV - Y:
Code. calculation indicates compliance
with the Florida Energy Code. rrrrr 'l•, =' °, `,�`O
PREPARED Y: Before construction is completed
DATE: this buildingwill be inspected for
P
compliance with Section 553.908
I hereby certify that tt�is'ESQr) ' as ned, is in compliance Florida Statutes.
with the Florida Energy Cod COD JVVnE'1T
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
i
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house.
3/29/2017 4:27 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title: Custom Tacoma_eArtisan_M Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 2908 Lot#
Owner: GHO Homes Total Stones: 1 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: GHO Homes Rotate Angle: 180 Street: 3316 Bent Pine Dr.
Permit Office: Cross Ventilation: County: Indian River
Jurisdiction: Whole House Fan: City,State,Zip: Ft.Pierce,
Family Type: Single-family FL, 34951
New/Existing: New(From Plans)
Comment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,VERO BEACH_MUN FL VERO_BEACH_MUNI 2 45 90 70 75 299 64 Medium
BLOCKS
Number Name Area Volume
1 Blockl 1235 11522.5
2 Block2 1673 15609.1
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 1 st Floor A 1235 11522.5 Yes 2 2 1 Yes Yes Yes
2 1st Floor B 1673 15609.1 No 2 1 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1st Floor A 96.34 ft 0 1235 ft2 0.5 0 0.5
2 Slab-On-Grade Edge Insulatio 1st Floor B 123.15 ft 0 1673 ft2 ____ 0.6 0 0.5
ROOF
/ Roof Gable Roof Solar SA Emitt ,Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Metal 3252 ft2 0 ft2 Unfinishe 0.7 No 0.7 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 2908 ft2 N N
i
3/29/2017 4:27 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
t
a '
FORM R405-2014
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 1 st Floor A 30 Blown 1235 ft2 0.11 Wood
2 Under Attic(Vented) 1 st Floor B 30 Blown 1673 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
Qrnt 10 Mil TVPV.1 S=>N Garage Frame-Steel 1 st Floor A 11 23 9 4 214.7 ft2 0.23 0.01 0
2 W=>E Garage Frame-Steel 1 st Floor A 11 7 2 9 4 66.9 ft2 0.23 0.01 0
3 E=>W Exterior Concrete Block-Int Insult st Floor A 4.1 1 9 4 9.3 ft2 0 0.600000 0
4 S=>N Exterior Concrete Block-Int Insunst Floor B 4.1 10 4 9 4 96.4 ft2 0 0.600000 0
z 5 SE=>NW Exterior Concrete Block-Int Insullst Floor B 4.1 2 7 9 4 24.1 ft2 0 0.600000 0
- 6 E=>W Exterior Concrete Block-Int Insullst Floor B 4.1 1 7 9 4 14.8 ft2 0 0.600000 0
_ 7 S=>N Exterior Concrete Block-Int Insullst Floor B 4.1 7 10 9 4 73.1 ft2 0 0.600000 0
_ 8 W=>E Exterior Concrete Block-Int Insull st Floor B 4.1 2 3 9 4 21.0 ft2 0 0.600000 0
9 SW=>NE Exterior Concrete Block-Int Insull st Floor B 4.1 3 0 9 4 28.0 ft2 0 0.600000 0
10 S=>N Exterior Concrete Block-Int Insull st Floor B 4.1 12 7 9 4 117.4 ft2 0 0.600000 0
_11 E=>W Exterior Concrete Block-Int Insullst Floor B 4.1 51 6 9 4 480.7 ft2 0 0.600000 0
_12 N=>S Exterior Concrete Block-Int Insullst Floor B 4.1 14 8 9 4 136.9 ft2 0 0.600000 0
13 W=>E Exterior Concrete Block-Int Insullst Floor B 4.1 1 0 9 4 9.3 ft2 0 0.600000 0
_14 N=>S Exterior Concrete Block-Int Insullst Floor B 4.1 15 10 9 4 147.8 ft2 0 0.600000 0
15 N=>S Exterior Concrete Block-Int Insull st Floor A 4.1 20 2 9 4 188.2 ft2 0 0.600000 0
16 W=>E Exterior Concrete Block-Int Insull st Floor A 4.1 45 0 9 4 420.0 ft2 0 0.600000 0
17 W=>E Interior Frame-Steel 1st Floor B 0 49 9 9 4 464.3 ft2 0 0.23 0.600000 0
DOORS
# Ornt Door•Type Space Storms U-Value Width Height Area
Ft In Ft In
1 S=>N Wood 1st Floor A None .14 2 8 8 21.3 ft2
2 W=>E Insulated 1st Floor A None .14 2 6 8 20 ft2
3 S=>N Insulated 1st Floor B None .14 3 8 24 ft2
4 S=>N Insulated 1st Floor B None .14 3 8 24 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 180 degrees).
/ Wall Overhang
# Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 S=>N 4 Metal Low-E Double Yes 0.45 0.26 12.0 ft2 1 ft 0 in 1 ft 8 in Drapes/blinds None
2 S=>N 4 Metal Low-E Double Yes 0.61 0.25 30.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None
' 3 S=>N 7 Metal Low-E Double Yes 0.45 0.26 14.5 ft2 9 ft 6 in 2 ft 5 in Drapes/blinds None
4 S=>N 10 Metal Low-E Double Yes 0.45 0.26 12.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None
5 E=>W 11 Metal Low-E Double Yes 0.61 0.25 14.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None
6 N=>S 12 Metal Low-E Double Yes 0.61 0.25 40.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None
7 N=>S 14 Metal Low-E Double Yes 0.45 0.26 16.0 ft2 13 ft 0 in 0 ft 8 in Drapes/blinds None
8 N=>S 14 Metal Low-E Double Yes 0.52 0.22 96.0 ft2 13 ft 0 in 2 ft 8 in Drapes/blinds None
9 N=>S 15 Metal Low-E Double Yes 0.45 0.26 8.0 ft2 13 ft 0 in 0 ft 8 in Drapes/blinds None
3/29/2017 4:27 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 180 de rees.
Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
10 N=>S 15 Metal Low-E:Double Yes 0.61 0.25 36.0 ft2 13 ft 0 in 2 ft 8 in Drapes/blinds None
11 W=>E 16 Metal Low-E Double Yes 0.61 0.25 6.0 ft2 1 ft 0 In 0 ft 8 in Drapes/blinds None
12 W=>E 16 Metal Low-E Double Yes 0.61 0.25 40.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None
13 W=>E 16 Metal Low-E Double Yes 0.61 0.25 6.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 784.8858 ft2 784.8858 ft2 83.5 ft 9.33 ft 0
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000296 2261 124.12 233.43 .2223 5
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Strip Heat None COPA 24 kBtu/hr 1 sys#1
2 Electric Strip Heat None COP:1 30 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER:16 24 kBtu/hr 720 cfm 0.75 1 sys#1
2 Central Unit None SEER:16 30 kBtu/hr 900 cfm 0.75 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
-Supply- -Return- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 290.8 ft Attic 72.7 ft2 Proposed Qn 1 st Floor A -cfm 74.1 cfm 0.06 0.50 1 1
2 Attic 6 290.8 ft Attic 72.7 ft2 Proposed Qn 1 st Floor B -cfm 100.4 cfm 0.06 0.50 2 2
i
3/29/2017 4:27 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
TEMPERATURES
Programable Thermostat:Y H ] Ceiling Fans: N
Nov
Heat ng Jan Feb f X]Mar Apr May Jun rl Jun Jul Aug Sg ri ep �(�Oct Nov Jul Au ep Oct Dec
Venting Jan Feb X Mar Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
II Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
i
3/29/2017 4:27 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
ENERGY PERFORMANCE LEVEL EPL
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
3316 Bent Pine Dr., Ft. Pierce, FL, 34951
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1767.10 ft2
b.Interior Frame-Steel, Interior R=0.0 464.33 ft2
3. Number of units,if multiple family 1 c.Frame-Steel,Adjacent R=11.0 281.56 ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 2908.00 ft2
6. Conditioned floor area(ft2) 2908 b. N/A R= ft2
7. Windows- Description Area c.NIA R= ft2:
a. U-Factor: Dbl, U=0.61 172.00 ft2 11 Ducts R ft
a.Sup:Attic, Ret:Attic,AH: 1st Floor A 6 290.8
SHGC: SHGC=0.25 b.Sup: Attic, Ret:Attic,AH: 1st Floor B 6 290.8
b. U-Factor: Dbl, U=0.52 96.00 ft2
SHGC: SHGC=0.22 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl, U=0.45 62.50 ft2 a.Central Unit 24.0 SEER:16.00
SHGC: SHGC=0.26 b.Central Unit 30.0 SEER:16.00
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a. Electric Strip Heat 24.0 COP:1.00
Area Weighted Average Overhang Depth: 7.037 ft. b.Electric Strip Heat 30.0 COP:1.00
Area Weighted Average SHGC: 0.243
stems
8. Floor Types Insulation Area 14.Hot waters y
a. Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2908.00 ft2EF:0.95
b. N/A R= ft2 b. Conservation features
c. N/A R= ft2 None
15.Credits Pstat
I certify that this home has compli d with the Florida Energy Efficiency Code for Building TFiE ST
Construction through the above a ergy saving features which will be installed (or exceeded) tio�,h�- = 9rF0
in this home before final inspectio . Otherwise, a new EPL Display Card will be completed � ' �°�, ,-'
based on installed Code complia 1 features. f- fill,,
Builder Signature: Date:
Address of New Home: r _ City/FL Zip: wE ��'S
`f�S/
"Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/29/2017 4:27 PM 'EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
i
Building Analysis DatJobe: Tacoma t-zs2
Date: 12-21-16
(Rest of House) By: Skyetec
• Information.
For: GHO Homes
3316 Bent Pine Dr, Fort Pierce, FL 34951 �n I�O O5 /8
Design,
Location: Indoor: Heating Cooling
Vero Beach, FL, US Indoor temperature(°F) 70 75
Elevation: 26 ft Design TD (°F) 27 15
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 22.0 61.5
Dry bulb(°F) 43 90 Infiltration:
Daily range(°F) - 16 ( L ) Method Simplified
Wet bulb(°F) - 78 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Heati'pg
Component Btuh/ft2 Btuh % of load
Walls 3.7 3072 21.4
Glazing 15.3 1538 10.7
Doors 10.5 477 3.3
Ceilings 0.9 952 6.6
Floors 2.0 2246 15.6
Infiltration 2.4 1642 11.4
Ducts 2752 19.1
Piping 0 0 -
Humidification 0 0
Ventilation 1697 11.8
Adjustments 0
Total 14376 100.0
Cooling
Component Btuh/ft2 Btuh % of load
Walls 2.3 1934 12.5 w
Glazing 18.7 1886 12.2
Doors 11.2 507 3.3
Ceilings 1.7 1838 11.9
Floors 0 0 0
Infiltration 0.7 456 2.9
Ducts 3524 22.7
Ventilation 943 6.1
Internal gains 4420 28.5
Blower 0 0
Adjustments 0
' I Total 1 1155081 100.0 "-
Latent Cooling Load=5434 Btuh
Overall U-value= 0.096 Btuh/ftZ-°F
Data entries checked.
Ih1tSOft' 2017-Mar-2316:12:03
Wrl
e 9 Right-Suite®Universal 2017 17.0.04 RS000268 Page 1
...culations\Skytec\Tacoma Lot-282 GL N Custom.rup Calc=MJ8 Front Door faces: N
I.
I
Building Analysis Job: Tacoma Lot-282
Date: 12-21-16
Master By: Skyetec
• - • •
For: GHO Homes
3316 Bent Pine Dr, Fort Pierce, FL 34951
Pesign Cond'itions,
Location: Indoor: Heating Cooling
Vero Beach, FL, US Indoor temperature(°F) 70 75
Elevation: 26 ft Design TD (°F) 27 15
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 22.0 61.5
Dry bulb(°F) 43 90 Infiltration:
Daily range(°F) - 16 ( L ) Method Simplified
Wet bulb(°F - 78 Construction quality Average
Wind speed (mph) 15.0 7.5 Fireplaces 0
Hea' ting
Component Btuh/ftz Btuh % of load m
Walls 3.9 3962 17.5
Glazing 14.5 3443 15.2 '
Doors 10.5 463 2.0 'I
Ceilings 0.9 1515 6.7
Floors 2.3 3998 17.6
Infiltration 2.4 3094 13.6
Ducts 4496 19.8
Piping 0 0
Humidification 0 0
Ventilation 1697 7.5
Adjustments 0 n"
Total 1 1 22668 100.0
Component Btuh/ftz Btuh % of load
Walls 2.5 2560 13.4
Glazing 11.5 2735 14.3 `w
Doors 11.2 492 2.6
Ceilings 1.7 2925 15.3
Floors 0 0 0
Infiltration 0.7 859 4.5
Ducts 5590 29.2
Ventilation 943 4.9
Internal gains 3050 15.9
Blower 0 0
Adjustments 0
' Total 1 1 19154 100.0 w �
Latent Cooling Load=7307 Btuh
Overall U-value= 0.103 Btuh/ftz-°F
Data entries checked.
Wrl �7tSOft® 2017-Mar-2316:12:03
9 Right-Suite®Universal 2017 17.0.04 RS000268 Page 2
...culations\Skytec\Tacoma Lot-282 GL N Custom.rup Calc=MJ8 Front Door faces: N
I
I
Project Summary Job: Tacoma Lot-282
Date: 12-21-16
(Rest of House) By: Skyetec
Project Information
For: GHO Homes
3316 Bent Pine Dr, Fort Pierce, FL 34951
Notes:
Design Information
Weather: Vero Beach, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 43 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 27 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 11625 Btuh Structure 11983 Btuh
Ducts 2752 Btuh Ducts 3524 Btuh
Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 14376 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 14732 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 4346 Btuh
Ducts 1089 Btuh
Heatingg Coolingg Central vent (0 cfm) 0 Btuh
Area(ft2) 1102 1102 Equipment latent load 5434 Btuh
Volume(ft3) 11103 11103
Air changes/hour 0.30 0.15 Equipment total load 20167 Btuh
Equiv.AVF(cfm) 55 28 Req. total capacity at 0.80 SHR 1.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Rheem
Trade Trade RHEEM; RUUD
Model Cond RA1624AJ1
AHRI ref Coil RH1T2417STAN
AHRI ref 7940891
Efficiency 80AFUE Efficiency 13.0 EER, 16 SEER
Heating input 0 Btuh Sensible cooling 19200 Btuh
Heating output 0 Btuh Latent cooling 4800 Btuh
Temperature rise 0 OF Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.056 cfm/Btuh Air flow factor 0.052 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.74
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
W1'1 I7tSOft` 2017-Mar-2316:12:03
9 Right-Suite®Universal 2017 17.0.04 RS000268 Page 1
...culations\Skytec\Tacoma Lot-282 GL N Custom.rup Calc=MJ8 Front Door faces: N
i
Project Summary Job: Tacoma Lot-282
Date: 12-21-16
Master By: Skyetec
i
TV-R a M, • •
For: GHO Homes
3316 Bent Pine Dr, Fort Pierce, FL 34951
Notes:
D- • • •
Weather: Vero Beach, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 43 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 27 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 18172 Btuh Structure 13564 Btuh
Ducts 4496 Btuh Ducts 5590 Btuh
Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 22668 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 18197 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 5567 Btuh
Ducts 1740 Btuh
Heating Cool ingg Central vent(0 cfm) 0 Btuh
Area (ft2 1753 1753 Equipment latent load 7307 Btuh
Volume(ft3) 18825 18825
Air changes/hour 0.33 0.17 Equipment total load 25504 Btuh
Equiv.AVF (cfm) 104 52 Req. total capacity at 0.80 SHR 1.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Rheem
Trade Trade RHEEM; RUUD
Model Cond RA1630AJ 1
AHRI ref Coil RH1T3617STAN
AHRI ref 7941343
Efficiency 80AFUE Efficiency 13.0 EER, 16 SEER
• Heating input 0 Btuh Sensible cooling 23200 Btuh
Heating output 0 Btuh Latent cooling 5800 Btuh
Temperature rise 0 OF Total cooling 29000 Btuh
Actual air flow 967 cfm Actual air flow 967 cfm
Air flow factor 0.043 cfm/Btuh Air flow factor 0.050 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.72
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
I'1 IItSOft' 2017-Mar-2316:12:03
W
9 Right-Suite®Universal 2017 17.0.04 RS000268 Page 2
ACCK ..culations\Skytec\Tacoma Lot-282 GL N Custom.rup Calc=MJ8 Front Door faces: N
I '
Tocoma
I
N
�F
BaZfS3 12 x 12
8 x 8 Dining
47 CFM - 12x12`
10,';q.0 ft
105 CFM
6',14.0 tt 12x12 T
Master Suite
Bedroom 3 s ,5.6 ft';
10 x 10 10 x 10
o 164CFM 8",4.8ft
149 CFM 16 x 16 11pp�L710p�
.9',10.1 ft 8',12.3 ft 2N bpA
8",5.1 ft F 12 x 12 Great Roam
- ' 4',5.2ft
Kitchen 207 CFM
6 3NftE`1 SryIC 2
3 1 =M 6 x 6
4',-.6tt 15CF
8', . ft 14',23.0ft
10x10 Ox10 y 8 x 8
171 CF 24 x%O CFM 1 CFM 94 CFM
F 8',t,5.3 ft
6x6 F
7 CFM 14',33.0 ft
Bedroom 2 1�0t 1 1O 4.5 ft
4 6.8 f 16 19.7 ft
CF Master Bath
',
10',4.5 ft Y
12x1216 12.1 ft 6x6
2 CFM
4 ,6.Of 10x10 67CFA 4•,10.5 ft
,6"p9.0 it Bx6 y 98CFM y
Bath 2 - 45 CF
sxs 7',8.oft Foyer
O .46 CFM Mud Utilit Y y 12 x 12
18•,4.2ft 5',3.0 ft 139 CFM
p(f' Hers •'15.2 ft
2.0 2.5
16',14.7 ft
18',18.1 ft "
FT
4',2.4 ft
6x6
2.0 Ton 23 CFM
2.5 Ton
Schedule
Garage F Exhaust Fan
R Range Vent
D Dryer Vent
Rheem Equipment
AHU 2.5 Tan 16 SEER RHIT36
Cand 2.5 Ton 16 SEER RA1630
AHU 2.0 Ton 16 SEER RH1T24
Cond 2.0 Ton 16 SEER M1624
Job#: Tacoma Lot-282 Scale: 1 : 131
Performed by Skyetec for: Page 1
GHO Homes Right-Suite®Universal 2017
3316 Bent Pine Dr 17.0.04 RS000268
Fort Pierce,FL 34951; 2017-Mar-23 16:12:05
...c\Tacoma Lot-282 GL N Custom.rup
Job: Tacoma Lot-282
Duct System Summary Date: 12-21-16
(Rest of House) By: Skyetec
. ,Project
For: GHO Homes
3316 Bent Pine Dr, Fort Pierce, FL 34951
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0.18 in H2O 0.18 in H2O
Available static pressure 0.32 in H2O 0.32 in H2O
Supply/return available pressure 0.225/0.095 in H2O 0.225/0.095 in H2O
Lowest friction rate 0.104 in/100ft 0.104 in/100ft
Actual air flow 800 cfm 800 cfm
Total effective length (TEL) 309 ft
SupplyDetail Table
Design Htg Cig Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln(ft) Trunk
Bathe h 1277 71 46 0.137 5.0 Ox0 VIFx 23.7 140.0 st2
Bath 3 h 1889 105 47 0.104 6.0 Ox 0 VIFx 51.7 165.0 st4
Bedroom 2 h 3232 180 171 0.138 8.0 Ox0 VIFx 23.0 140.0 st2
Bedroom 3 c 2892 148 149 0.111 8.0 Ox0 VIFx 42.8 160.0 st4
Dining h 3436 191 105 0.110 9.0 Ox0 VIFx 43.3 160.0 st4
Kitchen c 4021 48 207 0.108 9.0 Ox0 VIFx 47.9 160.0 st4
MECH h 727 40 23 0.219 4.0 Ox0 VIFx 2.4 100.0
Pantry c 136 6 7 0.139 4.0 Ox0 VIFx 21.6 140.0 st2
Utility c 867 10 45 0.140 4.0 Ox0 VIFx 20.8 140.0 st2
SupplyDetail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk
st4 Peak AVF 492 509 0.104 476 14.0 0 x 0 VinlFlx st2
st2 Peak AVF 760 777 0.104 557 16.0 0 x 0 VinlFlx
TableReturn Branch Detail
Grill Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk
rb1 Ox0 800 800 92.1 0.104 573 16.0 Ox 0 VIFx rst3
Bold/italic values have been manually overridden
wri htsoft® 2017-Mar-2316:12:03
9 Right-Suite®Universal 2017 17.0.04 RS000268 Page 1
...culations\Skytec\Tacoma Lot-282 GL N Custom.rup Calc=MJ8 Front Door faces: N
Return Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk
rst3 Peak AVF 800 800 0.104 573 16.0 0 x 0 VinlFlx
Bold/italic values have been manually overridden
wri htsoft® 2017-Mar-2316:12:03
9 Right-Suite®Universal 2017 17.0.04 RS000268 Page 2
...culations\Skytec\Tacoma Lot-282 GL N Custom.rup Calc=MJ8 Front Door faces: N
Job: Tacoma Lot-282
Duct System Summary Date: 12-21-16
Master By: Skyetec
j
Project Inf6rmation,
For: GHO Homes
3316 Bent Pine Dr, Fort Pierce, FL 34951
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0.18 in H2O 0.18 in H2O
Available static pressure 0.32 in H2O 0.32 in H2O
Supply/return available pressure 0.205/0.115 in H2O 0.205/0.115 in H2O
Lowest friction rate 0.093 in/100ft 0.093 in/100ft
Actual air flow 967 cfm 967 cfm
Total effective length (TEL) 344 ft
SUP.'ply Brandh Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FIR (in) (in) Mad Ln (ft) Ln (ft) Trunk
Foyer h 1743 74 67 0.127 5.0 Ox 0 VIFx 21.1 140.0 st1
Great Room c 3253 113 164 0.118 8.0 OXO VIFx 33.4 140.0 SO
Great Room-A c 3253 113 164 0.093 8.0 Ox0 VIFx 54.8 165.0 st3
Hers h 4142 177 139 0.118 9.0 Ox0 VIFX 33.3 140.0 st1
Master Bath h 2260 96 94 0.096 6.0 Ox 0 VIFx 48.9 165.0 st3
Master Suite-A h 5496 234 220 0.094 8.0 Ox 0 VIFx 47.4 170.0 st3
Office h 3008 128 98 0.123 7.0 Ox0 VIFx 26.1 140.0 st1
WC c 41 1 2 0.118 4.0 Ox0 VIFx 28.6 145.0 st1
wic 1 c 64 1 3 0.100 4.0 Ox0 VIFx 44.2 160.0 st3
WIC 2 h 653 28 15 0.096 4.0 Ox 0 VIFx 47.8 165.0 st3
• • ly Trunk'Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk
st3 Peak AVF 473 497 0.093 465 14.0 0 X 0 VinlFlx st1
st1 Peak AVF 967 967 0.093 547 18.0 0 x 0 VinlFlx
Bold/italic values have been manually overridden
wri htsoft® 2017-Mar-2316:12:03
9 Right-Suite®Universal 2017 17.0.04 RS000268 Page 3
...culations\Skytec\Tacoma Lot-282 GL N Custom.rup Calc=MJ8 Front Door faces: N
I
I
' Ta.ble
Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk
rb2 Ox 0 967 967 123.9 0.093 692 16.0 Ox 0 VIFx rst2
Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk
rst2 Peak AVF 967 967 0.093 547 1&0 0 x 0 VinlFlx
Bold/italic values have been manually overridden
Wri htsoft° 2017-Mar-2316:12:03
9 Right-Suite®Universal 2017 17.0.04 RS000268 Page 4
...culations\Skytec\Tacoma Lot-282 GL N Custom.rup Calc=MJ8 Front Door faces: N