{ a r a FL# FL20876
Application Type New
Code Version 2014
Application Status Approved
I *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived ❑
Product Manufacturer Dupont
Address/Phone/Email 5401 Jefferson Davis Highway
Richmond,VA 23234
(804)383-4031
theresa.a.weston@usa.dupont.com
Authorized Signature Theresa Weston
I theresa.a.weston@usa.dupont.com
i
Technical Representative John Johnston
Address/Phone/Email 5401 Jefferson Davis Highway
Richmond,VA 23234
(804) 383-2621
lohn.C.3ohnston@dupont.com
Quality Assurance Representative Barbara Crowder-Moore
Address/Phone/Email 5401 Spruance Road
Richmond,VA 23234
I; (804)383-3245
Barbara.J.Crowder@dupont.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Product Evaluation Entity
Evaluation Entity Intertek Testing Services NA,Inc.
Quality Assurance Entity Intertek Testing Services NA,Inc.
Quality Assurance Contract Expiration Date 01/01/2020
Validated By Intertek Testing Services NA,Inc.
;I
Certificate of Independence
'I
Referenced Standard and Year (of Standard) Standard Year
ASTM D226 2006
I
� I
Equivalence of Product Standards
Certified By
Sections fromithe Code
I
I
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQ WtDgtbxPgODTr%2b... 2/3/2017
Florida Building Code Online, Page 2 of 2
TOR
�Cl T r�
' I
Product Approval Method Method 1 Option Cyr ,J
Date Submitted 07/28/2016 `
Date Validated 07/29/2016
Date Pending FBC Approval a
Date Approved 07/29/2016
Summary of Products
FL# Model, Number or Name Description
20876.1 Dupont Tyvec Protec Underlayment 120, 160,and 200
Limits of Use i Installation Instructions
Approved for use in HVHZ: No FL20876 RO II Tvvek Protec Install Guideline BCIS.Ddf
Approved for use outside HVHZ: Yes Verified By: Intertek Testing Services NA,Inc.
Impact Resistant: N/A Created by Independent Third Party:
Design Pressure:N/A Evaluation Reports
Other:ASTM D226 Type I and Type II FL20876 RO AE Protec CCRR-1062 Der Intertek May 25
2016.Ddf
Back Next
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::A iblliN tatement::Refund Statement
Under Florida law,'email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
iChapter 455,F.S.,please click here.
III Product Approval Accepts:
Credit Card
Safe
;i
II
,I
1 I
� I �
i
I
,
,
li
I
II
� I
� I
I I
i
I
(
I
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtbxPgODTr%2b... 2/3/2017
INSTA(1,4T{ONGUIDELINES j' CUP TOR C fs
. . V
DUPONr M Tl(V KOE P ROT
ECTM f
ROOFING UNDERLAY ENT tNS�'AL AT(ON GCOfD.ELiNES
o,
{ INSTALLATION GUIDELINES ACCEPTABLE FOR USE WITH • DuPont-Tyvek•Protec"provides protection against
• Tyvek•Protec'" 120 leaks under all types of roof coverings identified by
I
I, • Tyvek•Protec"' 160 ICC-ES AC188.
• Tyvekm Protec'"200 • DuPont'Tyvek°Protec`"has code approval per ICC-ES
AC188. For use in Canada,reference Interlek Report
SPECIFICATIONS #CCRR-1062.
• DuPont'"Tyvek"Protec'"rolls are available in:
-10-square:48"x 25071.2m.x 76.2m(92.9m2) PRECAUTIONS AND SAFETY
• DuPont'"TyveV Protec'is.for use on roofs with slopes • Apply DuPont'Tyvele Protece'taut and wrinkle-Free.
2:2:12 Do not stretch.
jDuPont"'Tyvee Protec'"must be covered with the final Use plastic or metal cap fasteners with ring shank or
roof cladding within: smooth shank nails for safe,secure installation.
— 3-months with Tyvele Protec 12U • Do not apply DuPont'"Tyvele Protec'"over wet or
frost-covered roof sheathing.
i — 6-months with Tyvek'Protec'" 160 or TyveV Do not walk on DuPont'"Tyvele Protec'"until it has
Protect-200 y'�'
j been fastened according to instructions.
DuPont'Tyvele Protec'should not be considered a final • Do not walk on DuPont"Tyvele Protec'when it is wet
roofing system.Tyveh Protec'"is a secondary layer applied or frost-covered.
over sheathing,under a primary roofing system like: . Use fall protection when working on roof.Refer to
— DuPont'Tyvek®Protec'" 120-asphalt shingles, OSHA safety regulations 29 CFR1926 subpart M.
metal or cedar roof cladding • Consult your local DuPont'"Tyvek•Specialist for
— DuPont'Tyvele Protec 160-asphalt shingles,tile, additional information.
metal,cedar,or slate roof cladding
PREPARATION
— DuPont'Tyvek°Protec';"200-asphalt shingles,tile, Apply DuPont'"Tyvek°Protec"'over a dry,smooth,
metal,cedar,or slate roof cladding clean and defect-free roof deck.
BUILDING CODE COMPLIANCE DuPont'Tyvek°Protec is a vapor barrier.Ensure that
• Consult local.building code and roof cladding the space beneath the roof sheathing is properly
j manufacturer for use of underlayment. ventilated before installing to avoid condensation
• Consult local building code and roof cladding problems.
manufacturer for underlayment edge and end overlap
and fastening requirements that may differ from
j DuPont'Tyvek®Protec"instructions.Follow the more
restrictive requirements.
• Where required by local building code,apply self-
adhering waterproof underlayment as the first course
along eave edges according to manufacturer's instructions
and DuPont'Tyvek•Protec"'for successive courses.
I
i
VNSTALLATIONGUIDELINES R COP
DUPONr"1YVEK° PROTECYM
ROOFING UN®ERLAYMENT INSTALLATION GUIDELINES
WPONT'"TYVEK°PROTEC"'INSTALLATION:INSTRU.CTIONS
Lay courses of DuPont"Tyveka Protec"'horizontally in 6. Install DuPont'Tyvek°'Protec'"over drip edges along eave
a I shingle style'fashion with 4."course overlaps and 6"end edge and under drip edges along.rake edges.
set end laps in 7, ]yap DuPont`"Tyvekm Protec'"8" (min)onto walls.
laps beginning along the cave edge.Off
I t 6 f
successive courses by feet. 8. Line roof valleys with a sheet of DuPont'"Tyvek7 Protec"'
2. Artach DuPont7'Tyvek"Protec7'to the roof sheathing with prior to installing horizontal courses of DuPont'Tyvek°
1"diameter(min)metal or plastic cap-nails or cap-staples Protec".Lap the ends of horizontal DuPont'"Tyvele Protece'
driven flush with the roof deck surface.DO NOT USE courses over the valley sheet by 6".
uncapped nails or uncapped staples.All anchoring must be 9. At ridges and hips where ridge vents will not be applied,
performed flush to the roof and 90 degrees to the roof deck. cross-lap DuPont"T)wk'Protec`"from one roof plane onto
3. Space fasteners at 6"on center(o.c.)along course and end the other-by 6".For additional weather protection,apply a.
laps and a single row 12"ox:in the field of the sheets. 24"wick slicer-of DuPont'"TyvcV Protec"'across hips and
4. In high wind zones(at or above 100 mph per IRC R301.2), ridges.
space fasteners at 4 o.c.along courses and end laps and two
rows 12"o.c.in the field of the sheets.
5. Apply DuPont`Tyvek"Protece'with two layers on roofs
with.slopes between 2:12 and 4:12.Begin with a 26"
undercourse strip parallel to the eave edge,and then cover
with a full width sheet.Overlap successive sheets by 26".