Loading...
HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online f a e of �. BCIS Home , Log In User Registration ? Hot Topics Submit Surcharge s Stats.&Facts ? Publications i FBC Staff1Ce,Map; �Product ApprovalUSER:Public User , zsa t Product Aooroval Menu>�Product or.Aoolication Search>Application List>Application Detail { a r a FL# FL20876 Application Type New Code Version 2014 Application Status Approved I *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer Dupont Address/Phone/Email 5401 Jefferson Davis Highway Richmond,VA 23234 (804)383-4031 theresa.a.weston@usa.dupont.com Authorized Signature Theresa Weston I theresa.a.weston@usa.dupont.com i Technical Representative John Johnston Address/Phone/Email 5401 Jefferson Davis Highway Richmond,VA 23234 (804) 383-2621 lohn.C.3ohnston@dupont.com Quality Assurance Representative Barbara Crowder-Moore Address/Phone/Email 5401 Spruance Road Richmond,VA 23234 I; (804)383-3245 Barbara.J.Crowder@dupont.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity Intertek Testing Services NA,Inc. Quality Assurance Entity Intertek Testing Services NA,Inc. Quality Assurance Contract Expiration Date 01/01/2020 Validated By Intertek Testing Services NA,Inc. ;I Certificate of Independence 'I Referenced Standard and Year (of Standard) Standard Year ASTM D226 2006 I � I Equivalence of Product Standards Certified By Sections fromithe Code I I http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQ WtDgtbxPgODTr%2b... 2/3/2017 Florida Building Code Online, Page 2 of 2 TOR �Cl T r� ' I Product Approval Method Method 1 Option Cyr ,J Date Submitted 07/28/2016 ` Date Validated 07/29/2016 Date Pending FBC Approval a Date Approved 07/29/2016 Summary of Products FL# Model, Number or Name Description 20876.1 Dupont Tyvec Protec Underlayment 120, 160,and 200 Limits of Use i Installation Instructions Approved for use in HVHZ: No FL20876 RO II Tvvek Protec Install Guideline BCIS.Ddf Approved for use outside HVHZ: Yes Verified By: Intertek Testing Services NA,Inc. Impact Resistant: N/A Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other:ASTM D226 Type I and Type II FL20876 RO AE Protec CCRR-1062 Der Intertek May 25 2016.Ddf Back Next Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::A iblliN tatement::Refund Statement Under Florida law,'email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under iChapter 455,F.S.,please click here. III Product Approval Accepts: Credit Card Safe ;i II ,I 1 I � I � i I , , li I II � I � I I I i I ( I http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtbxPgODTr%2b... 2/3/2017 INSTA(1,4T{ONGUIDELINES j' CUP TOR C fs . . V DUPONr M Tl(V KOE P ROT ECTM f ROOFING UNDERLAY ENT tNS�'AL AT(ON GCOfD.ELiNES o, { INSTALLATION GUIDELINES ACCEPTABLE FOR USE WITH • DuPont-Tyvek•Protec"provides protection against • Tyvek•Protec'" 120 leaks under all types of roof coverings identified by I I, • Tyvek•Protec"' 160 ICC-ES AC188. • Tyvekm Protec'"200 • DuPont'Tyvek°Protec`"has code approval per ICC-ES AC188. For use in Canada,reference Interlek Report SPECIFICATIONS #CCRR-1062. • DuPont'"Tyvek"Protec'"rolls are available in: -10-square:48"x 25071.2m.x 76.2m(92.9m2) PRECAUTIONS AND SAFETY • DuPont'"TyveV Protec'is.for use on roofs with slopes • Apply DuPont'Tyvele Protece'taut and wrinkle-Free. 2:2:12 Do not stretch. jDuPont"'Tyvee Protec'"must be covered with the final Use plastic or metal cap fasteners with ring shank or roof cladding within: smooth shank nails for safe,secure installation. — 3-months with Tyvele Protec 12U • Do not apply DuPont'"Tyvele Protec'"over wet or frost-covered roof sheathing. i — 6-months with Tyvek'Protec'" 160 or TyveV Do not walk on DuPont'"Tyvele Protec'"until it has Protect-200 y'�' j been fastened according to instructions. DuPont'Tyvele Protec'should not be considered a final • Do not walk on DuPont"Tyvele Protec'when it is wet roofing system.Tyveh Protec'"is a secondary layer applied or frost-covered. over sheathing,under a primary roofing system like: . Use fall protection when working on roof.Refer to — DuPont'Tyvek®Protec'" 120-asphalt shingles, OSHA safety regulations 29 CFR1926 subpart M. metal or cedar roof cladding • Consult your local DuPont'"Tyvek•Specialist for — DuPont'Tyvele Protec 160-asphalt shingles,tile, additional information. metal,cedar,or slate roof cladding PREPARATION — DuPont'Tyvek°Protec';"200-asphalt shingles,tile, Apply DuPont'"Tyvek°Protec"'over a dry,smooth, metal,cedar,or slate roof cladding clean and defect-free roof deck. BUILDING CODE COMPLIANCE DuPont'Tyvek°Protec is a vapor barrier.Ensure that • Consult local.building code and roof cladding the space beneath the roof sheathing is properly j manufacturer for use of underlayment. ventilated before installing to avoid condensation • Consult local building code and roof cladding problems. manufacturer for underlayment edge and end overlap and fastening requirements that may differ from j DuPont'Tyvek®Protec"instructions.Follow the more restrictive requirements. • Where required by local building code,apply self- adhering waterproof underlayment as the first course along eave edges according to manufacturer's instructions and DuPont'Tyvek•Protec"'for successive courses. I i VNSTALLATIONGUIDELINES R COP DUPONr"1YVEK° PROTECYM ROOFING UN®ERLAYMENT INSTALLATION GUIDELINES WPONT'"TYVEK°PROTEC"'INSTALLATION:INSTRU.CTIONS Lay courses of DuPont"Tyveka Protec"'horizontally in 6. Install DuPont'Tyvek°'Protec'"over drip edges along eave a I shingle style'fashion with 4."course overlaps and 6"end edge and under drip edges along.rake edges. set end laps in 7, ]yap DuPont`"Tyvekm Protec'"8" (min)onto walls. laps beginning along the cave edge.Off I t 6 f successive courses by feet. 8. Line roof valleys with a sheet of DuPont'"Tyvek7 Protec"' 2. Artach DuPont7'Tyvek"Protec7'to the roof sheathing with prior to installing horizontal courses of DuPont'Tyvek° 1"diameter(min)metal or plastic cap-nails or cap-staples Protec".Lap the ends of horizontal DuPont'"Tyvele Protece' driven flush with the roof deck surface.DO NOT USE courses over the valley sheet by 6". uncapped nails or uncapped staples.All anchoring must be 9. At ridges and hips where ridge vents will not be applied, performed flush to the roof and 90 degrees to the roof deck. cross-lap DuPont"T)wk'Protec`"from one roof plane onto 3. Space fasteners at 6"on center(o.c.)along course and end the other-by 6".For additional weather protection,apply a. laps and a single row 12"ox:in the field of the sheets. 24"wick slicer-of DuPont'"TyvcV Protec"'across hips and 4. In high wind zones(at or above 100 mph per IRC R301.2), ridges. space fasteners at 4 o.c.along courses and end laps and two rows 12"o.c.in the field of the sheets. 5. Apply DuPont`Tyvek"Protece'with two layers on roofs with.slopes between 2:12 and 4:12.Begin with a 26" undercourse strip parallel to the eave edge,and then cover with a full width sheet.Overlap successive sheets by 26". I i J� I J I' I� Copyrighl Q 2016 DuPont:Me DuPont Oval Logo,DuPont`;TyveO and Pfotec`are imdemoeks or registered tradetnorks of E L du Pant de Plemours grid Compony ar its orllotes. All rights reserved.K=2932?5 61161