Loading...
HomeMy WebLinkAboutEvaluation Report U.S..bEPARTMENT OF HOMELAND SECURITY OMB No.1660-0008 Federal Emergency Management Agency Expiration Date:November 30,2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Fallow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for(1)community official,(2)insurance agent/company,and(3)building owner. SECTION A—PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number. _ KEXEL A2. Building Street Address(including Apt,Unit,Suite,and/or Bldg.No.)or P.O.Route and Company NAIC Number. Box No. 2005 NETTLES-BLVD. City State ZIP Code JENSEN BEACH 'Florida 34957 A3. Property Description(Lot and Block Numbers,Tax Parcel Number;Legal Description,etc.) LOT 5,NETTLES ISLAND SECTION 1 A4. Building Use(e.g.,Residential, Non-Residential,Addition,.Accessory,etc.) RESIDENTIAL A5. Latitude/l-ongitude: Lat 27"1T08X' Long.80°12'53.5° Horizontal Datum: ❑NAD 1927x❑ NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1B .Q A8. For a building with a crawispace or enclosure(s): a) Square footage of crawispace or enclosure(s) N/A sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s)within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A8.b N/A sq in d) Engineered flood openings? ❑Yes 0 No A9.For a building with an attached garage: a) Square footage of attached garage 112 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 2 c) Total net area of flood openings in A9.b 1688 sq in d) Engineered flood openings?' x0 Yes ❑No SECTION B—FLOOD INSURANCE RATE MAP(FIRM)INFORMATION B1.NFIP Community Name&Community Number B2.County Name B3. State UNINCORP 120285 ST.LUCIE Florida B4.Map/Panel B5.Suffix B6. FIRM Index B7.FIRM Panel B8.Flood B9.Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO,use Base Flood Depth) Revised Date 12111C 0311 J 02/16/2012 02/16/2012 AE 6.0 B10. Indicate the source of the Base Flood Elevation(BFE)data or base flood depth entered in Item 139: ❑FIS Profile g FIRM ❑Community Determined ❑Other/Source: 811. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929x❑ NAVD 1988 ❑ Other/Source: 812. Is the building located in a Coastal Barrier Resources System(CBRS)area or Otherwise Protected Area(OPA)? ❑Yes ❑X No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 1 of 6 ELEVATION CERTIFICATE OMB No.1660-0008 Expiration Date:November 30,2018 IMPORTANT:In these spaces copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt.,Unit,Suite,and/or Bldg.No.)or P.O.Route and Box No. Policy Number ze>es h. e_- X_-__-'>L-VQ1 City State ZIP Code Company NAIC Number 03 44 c�S7 SECTION C-BUILDING ELEVATION INFORMATION(SURVEY REQUIRED) C1. Building elevations are based on: [] Construction Drawings* []Building Under Construction* 0 Finished Construction *A new Elevation Certificate will be required when construction of the building Is complete. C2. Elevations-Zones AI-A30,AE,AH,A(with BFE),VE,VI-V30,V(with BFE),AR,ARIA,ARAE,AR/Al-A30,AR/AH,AR/AO. Complete Items C2.a-h below according to the building diagram specified In Item A7.In Puerto Rico only,enter meters. Benchmark Utilized: 94 77 A04 FDOT Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a)through h)below. F1 NGVD 1929 nx NAVD 1988 n other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement I used. a) Top of bottom floor(including basement,crawispace,or enclosure floor) 6.0 nx feet ❑ meters b) Top of the next higher floor N/A n feet ❑-meters c) Bottom of the lowest horizontal structural member(V Zones only) N/A n feet 0 meters d) Attached garage(top of slab) . .' !j.0 nx feet ❑ meters a) Lowest elevation of machinery or equipment servicing the building 6.1. nX feet ❑ meters (Describe type of equipment and location in Comments) 1) Lowest adjacent(finished)grade next to building(LAG) 3.6 [1 feet ❑ meters g) Highest adjacent(finished)grade next to building(HAG) 4.9 21 feet El meters h) Lowest adjacent grade at lowest elevation of deck or stairs,including 4.9 0 feet n metersstructural support SECTION 13-SURVEYOR,ENGINEER,OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor,engineer,or architect authorized by law to certify elevation information. I certify that the Information on this Cerffffcate represents my best efforts to interpret the data available./understand that any-false statement may be punishable by fine or imprisonment under 18 U.S.Code,Section 1001. Were latitude and-longitude in Section A provided by a licensed land surveyor? ElYes n No n Check here if attachments. Certifier's Name License Number t 75 -7- EARLE R.STARKEY 4469 Title PROFESSIONAL LAND SURVEYOR Company Name ACCURIGHT LAND SURVEYING INC. Address 1501 DECKER AVENUE#419' City State ZIP Code STUART Florida 34957 59 S - Ignaf R?tr-�. Date Telephone Ext. 08/3012017 772-286-7694 Copy all pages of this 121-0-affo—n-Cei—rdficate and all attachments for(1)community official,(2)insurance agent/company,and(3)building owner. Comments(Including type of equipment and location,per C2(e),if applicable) A9 IS A 3 SIDED CARPORT WITH I SMART VENT MODEL#1540-520(200 SO.INCHES)I USED THE CARPORT OPENING AS WIDTH OF 124 INCHES BY 12 INCHES(1488 SQ.INCHES) C2-E-A/C PLATFORM FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 2 of 6 Building Photographs See Inshudons for Item A6. For Insurance Camps"Use: Building Street-Address(inducting Apt.,Unit,Suite,and/or B14 No_)or P.O.Route and Box No. Porky,Number 2005 NETTLES BLVD. .City State ZIP Code C rwm NM Nw ber JENSEN BEACH FLORIDA 34957 if using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with:date taken; "Front Vein'and"Rear UeW;and, if required, "Right Side view!'and "Left side View.' If submitting more photographs than will fit on this page, use the Continuation Page, following. REAR 08/30/2017 ° f j r ry - 1 gg l Y'MM .Fri'1 MIR r, y s-\ - � n SIDE 08/30/2017 y C Most Widely Accepted and Trusted ICC EVALUATION SERVICE ICC-ES Report ESR-2074 ICC-ES 1 : ii 699-0543 • 02/2015 reportThis • to renewal 02/2017. DIVISION:08 00 00-OPENINGS SECTION: 08.95 43-VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 EVALUATION SUBJECT: SMART VENT°AUTOMATIC FOUNDATION FLOOD VENTS: MODELS#1540-520;#1540=521;#1540-510; #1540-511;#1540-570;#1540-574;#1540-524;#1540-514 1CC ICC ICC C c PING LISTED Look for the trusted marks of Conformity! if'11 _ "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC)Award in Excellence" A Subsidiary of I nE�IONAt NCIV ICC'ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not C"Is specificalby addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There,is no warranty by ICC Evaluation Service, LLC, express or implied, as Gg to any finding or other matter in this report or as to any product covered by the report. aca3 yYllr ACL+MA6 CCN , Copyright 0 2015 c c SERVICEICC EVALUATION Trusted ICC-ES Evaluation Report ESR-2074* f. Reissued February 2015 This report is subject to renewal February 2017. www.icc-es.Orq 1 (800)423-6587 1 (562)•699-0543' A.Subsidiary of the Intemationa/Code Council® DIVISION:08 00 00—OPENINGS The water level stabilizes, equalizing the lateral forces. Section:08 95 43—Vents/Foundation Flood Vents Each unit is fabricated from stainless steel. Smart Vent° Automatic Foundation Flood Vents are available in REPORT HOLDER: various models and sizes as described in Table 1. The SmartVENT®Stacking Model #1540-511 and FloodVENT° SMARTVENT PRODUCTS,INC. Stacking Model #1540-521 units each contain two 430 ANDBRO DRIVE, UNIT 1 vertically arranged openings per unit. PITMAN; NEW JERSEY 08071 (877)441-8368 3.2 Engineered Opening: www:smartvent.com The FVs comply with the design principle noted in Section infoAsmartvent.com 2.6.2.2 of ASCE/SEI 24 for a maximum rate of rise and fall of 5.0 feet per hour(0.423 mm/s): In order to comply with EVALUATION SUBJECT: the engineered opening requirement-of ASCE/SEI 24, Smart Vent FVs must be' installed in accordance with SMART VENT'AUTOMATIC FOUNDATION FLOOD VENTS: Section 4.0. MODELS #1540-520; #1540-521; #1540510; #1540-511; 3.3 Ventilation: #1540.570;#1540-574;#1540524;#1540514 The SmartVENTO Model #1540-510 and SmarIVENT® 1.0 EVALUATION SCOPE Overhead Door Model#1540-514 both have screen covers with 1/4-inch-by-1/4-inch (6.35 by 6.35 mm) openings, Compliance with the following codes: yielding 51 square inches(32 903 mm2)of net free area to ■ 2012,2009,and 2006 International Building Codeo(IBC) supply natural ventilation. The SmartVENT° Stacking Model #1540-511 consists of two Model #1540-510 units ■ 2012, 2009 and 2006 International Residential Code®• in one assembly, and provides 102 square inches (IRC) (65 806 mm2)of net free area to supply natural ventilation. ■ 2013 Abu Dhabi International Building Code(ADIBC)t Other FVs recognized in this report do not offer natural ventilation. 'The ADIBC is based on the 2009 IBC.2009 IBC code sections referenced in this report are the same sections in the ADIBC. 4.0 DESIGN AND INSTALLATION Properties evaluated:. SmartVENI4�' and FloodVENT 0 are designed to be ■ Physical operation installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the a Water flow vents must be in accordance with the manufacturer's 2.0 USES instructions, the applicable code and this report. The mounting straps allow mounting in masonry and concrete The Smart Vente units are engineered mechanically walls up to 12 inches (305 mm) thick. In order to comply operated flood vents (FVs) employed to equalize with the engineered opening design principle noted in hydrostatic pressure on wails of enclosures subject to Section 2.6.2.2 of ASCE/SEI 24,. the Smart Vent® FVs rising or falling flood waters. Certain models also allow must be installed as follows: natural ventilation. ■ With a minimum of two openings on different sides of 3.0 DESCRIPTION each enclosed area. 3.1 General: ■ With a minimum of one FV for every 200 square feet (18.6 m2) of enclosed area, except that the When subjected to rising water, the Smart Vent FVs SmartVENT® Stacking Model #1540-511 and internal floats are activated,then pivot open to allow flow in FloodVENTO Stacking Model #1540-521 must be either direction to equalize water level and hydrostatic installed with a minimum of one FV for every pressure from one side of the foundation to the other. The 400 square feet(37.2 m2)of enclosed area. FV pivoting door is normally held in-the closed position by Below the base flood elevation. a buoyant release device.When subjected-to rising water, the buoyant release device causes the unit to unlatch, ■ With the bottom of the FV located a maximum of allowing the door to rotate out of the way and allow flow. 12 inches (305.4 mm) above the higher of the final "Revised Julv 2015 /CC-ES Evaluation Reports are not to be construed as representing aesthetics or am other attributes not specifrcalhv addressed,nor are dies=to be consented Mqll as an endorsement of 1he subier"t of the report or a reconhmendation.for its use.There is no ivarrann,by/CC Evaluation Service.LLC.express or implied.as s to an•.finding or other marier in this report,nr as to amt product covered br the report. Copyright O 2015 Page 1 of 2 ,, •L s. e • l ..Y y.b yF+.S d't•3fk'•x=4Y¢.G'a y�-'�1 g�f �- -'£_'.i�..T�.s�}��c"a `}�•--'r.�....`.�`•;.-_ ri.,.._e<Y. �cr-•�` �•C��;.�-�` .�s"'.�.u�:.=�...c�'�.��„c��`,.�- •� 1 1 r ;r5 .d `+. "^/ i`l'„•„ S� 3 RIM Rl Mr IMP in �A t,� � .a r z• s .� y �- s ;r•d+s.cf..•Y' x � ,� '.' •al.,r�,�,,.X27.5. s -:. J-xv.r^'k '� ���"��ti+ .�.;..`,+,.«. � �'�`a'F�GG��v''��i+:���1-k Zi ESR-2074. I Most Widely AcceptedAft Tri .d Page 2 of 3 grade or floor and finished exterior grade immediately are permitted for use in conjunction with breakaway under each opening. walls in other areas. 5.0 CONDITIONS OF USE 6.0 EVIDENCE SUBMITTED The Smart Vent®FVs described in this report comply with, Data in accordance with'the ICC-ES Acceptance Criteria or are suitable alternatives to what is specified in, those for Mechanically Operated Flood Vents (AC364), dated codes listed in Section 1.0 of this report, subject to the October 2013(editorially revised May 2014). following conditions: 7.0 IDENTIFICATION 5.1 The Smart Vent®FVs must be installed in accordance The Smart VENT® models recognized in this report must with this report, the applicable .code and the be identified by a label bearing the manufacturer's name manufacturer's installation instructions. In the event of (Smartvent Products, Inc.), the model number, and the a conflict,the instructions in this report govern'. evaluation report number(ESR-2074). 5.2 The Smart Vent FVs must not be used in the place of"breakaway walls"in coastal high hazard areas, but TABLE 1—MODEL SIZES MODEL NAME MODEL NUMBER MODEL SIZE(in.) COVERAGE(sq.ft.) FloodVEN 1540-520 153/4"X 73/4" 200 SmartVENT D 1540-510 153/4"X 73/4" 200 FloodVENT®Overhead Door 1540-524 153/4"X 73/4' 200 SmartVENT°Overhead Door .1540-514'. 153/4"X 73/4" 200 Wood Wall FloodVENT° 1540-570 14"X 83/a" 200 Wood Wall FloodVENr Overhead Door 1540-574 14"X 83/4" 200 SmartVENT®Stacker 1540-511 _ 16"X 16" 400 FloodVent®Stacker 1540-521 16"X 16" 400 For SI: 1 inch=25.4 mm;1 square foot=m' . 17 1ICC EVALUATION Most c c SERVICE Widely Accepted and Trusted ICC-ES Evaluation Report ESR-2074 FBC Supplement* Reissued February 2015 This report is subject to renewal February 2017. www.icc-es.org 1 (800) 423-6587 1 (562)699-0543 A Subsidiary of the International Code Council DIVISION:08 00 00—OPENINGS Section:08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: SMARTVENT PRODUCTS,INC. 430 ANDBRO DRIVE,UNIT 1 PITMAN, NEW JERSEY 08071 .(877)441-8368 www.smartvent.com info(ftinartvent.com EVALUATION SUBJECT: SMART VEN-&AUTOMATIC FOUNDATION FLOOD VENTS:MODELS#1540-520;#1540-521;#1540-510;#1540-511;#1540-570; #1540-574;#1540-524;#1540-514 - 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Smart Vent®Automatic Foundation Flood Vents, recognized in ICC-ES master report ESR-2074,have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2014 Florida Building Code—Building(FBC) 0 2014 Florida Building Code—Residential(FRC) 2.0 CONCLUSIONS The Smart Vent's Automatic Foundation Flood Vents, described in.Sections 2.0 through 7.0 of the master evaluation report ESR-2074, comply with the FBC and the FRC, provided the design and installation are in accordance with the International Building Code®provisions noted in the master report. Use of the Smart Vent's Automatic Foundation Flood Vents has also been found to be in compliance with the High-Velocity Hurricane Zone provisions of the FBC and the FRC. For products failing under Florida Rule 9N-3,verification that the report holder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections beind-conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued February 2015 and revised July 2015. *Revised July 2015 !CC-ES Evaluation Reports m e not to be construed as representing aesdtetics or aur other attributes not specifically addressed,nor are tier to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warrant),by/CC Evaluation Service.LLC,express or implied,as to anv/finding or other natter in this report,or as to any product covered by the report. ° Copyright©2015 Page 1 of 1 f - DETAIL DIAGRAM . MODELS.1540-510 & 1540-520 DUAL FUNCTION FLOOD-AND VENTII.ATION VENT & FLOOD VENT INSULATED 1540-510 • 1540-520 16 1/4' R/D . 16 1/4' R/0 STRAP SLOTS USE TWO STRAP SLOTS USE TWO TOP AND TWO BOTTOM TOP AND TWO BOTTOM BEHIND THE RODENT SCREEN, LOUVERS AUTOMATICALLY OPEN AND CLOSE WITH \\� S 1/4 NEMEPDERDATURL NO ELECTRICITY.IS \�\ 8 1/4 _ R/0 FLOAT SLOTS FLOAT cors FIGURE 1 CAULK LOCATION a v a (FLANGE) e o STRAPS INSTALLED 2 ON TOP & Z ON BOTTOM VENT STRAPS ; � 6 !DOOR �i v a a s a VENT 12' MAX:FROM 1• . FRAME FINAL GRADE • 4-0 FIGURE 2 FIGURE 3 - . a TS x SMART VENT Foundotlon FCaod Vents STRAP DETAIL. g p 450 AndBro Dr. �+�Iat,ess Piton NJ 08071 - MAP m WN1 °nxic"'�+/_w gD Smart VENTS Duv,i+r�xcrtONrtoDD TEETH MUST CLICK IN TIGHT TO INSURE x�0`>oa1 0-� 877-441 8358 mDVENMAn0NVMff& c00DVMffINS== • SECURE INSTALLATION, BEND PAST 90• FO WWW.SMmnvw00M MODMS 134MID&154MO SPRING BACK M aso t>aN carte a+rm muviwa A, ow�1�• 1540-5XX n V W lOe6mo1 fF YY1R1vLxt M1E.z-,-07 SHRr I OF 2 1 T INSTALLATION INSTRUCTIONS Smart VENT &' DETAILS 877- 441- 8368 - MODELS 1540-510 & 1540-520 www.smartvent.com DUAL FUNCTION FLOOD AND VENTILATION VENT & FLOOD VENT INSULATED REV. C 05-01-09 INSTALLATION INSTRUCTIONS 1. Remove vent door from vent frame.(Tura upside down,rotate bottom of door outward and slide out) 2. Prepare a CLEAN 16,25"wide by 8.25"high rough opening(approx. l block wide X 1 block high) for each vent. Ensure the bottom of the rough opening is no more than 12"above the finished inside or outside grade whichever is higher 3. Apply a bead of polyurethane Caulk around the back of the flange on the vent frame,(FIG.2) 4. Bend the 4 steel straps to the thickness of the wall measuring from the end with the teeth'see STRAP DETAIL 5.Insert the top straps into the top two strap slots about two clicks. 6. Insert the vent fume in the cut opening.The bent strap ends go in then up behind the inside of the wall. Push the frametight against the face of the wall.Ensure the frame is flush and square in the opening.(FIG.3) 7,Reach through the vent opening and click the two straps in while holding the front of the vent against the wall face.The sharp point of the straps should not extend past the front of the vent face.Install the two remaining bottom straps. 8. 'Re-check that frame is square and slots are clear of debris,and caulk. 9. Install the door into frame by grasping the bbttom of door(with float pins down)and front(small screen in front). Slide door into frame and rotate until it is latched. 10. To open the door insert two credit cards into the float slots as shown in the diagram.This will unlatch the door for removal and cleaning. MODEL 1540-510 MODEL 1540-520 DETAILED SPECIFICATIONS: DETAILED SPECIFICATIONS: MATERIAL:STANLESS SEL OPERATION FLOOD:AUTOMATIC NON-POWERED ACTIVATION AND OPERATION MAIERIAU STAINLESS STEEL VENT REMAINS CLOSED AND LOCKED UNTIL ACTIVATED OPERATION: AUTOMATIC NON—POWERED ACTIVATION AND OPERATION OPERATION AIR:AUMM4110 LOUVERS FULLY OPEN AT 78 DEO. FULLY CLOSED AT 35 DEO. NO POWER REQUIRED INSTNIATIDN: INSTALLATION. SECURED W/4 STAINLESS STF�7.STRAPS SUPPLIED SECURED W 4 STAINLESS STEEL STRAPS SUPPLIED HYDROSIATID RELIEF1 zDo Sq. Ft p.r wnt REQUIR HYDROSTATIC RELIEF, Z00 Sq. Ft VENTS Vent VENRLATKLN: 81 Sq.I p.r Vant NOTE VAPOR BARRIER AL OWS FOR REDUCED VEN I ATION RECUIRF}AENiS: MINIMUM OF 2 VENiS PER ENCLOSED AREA MOUNTED ON AT LEAST TWO DIFFERENT WALLS ` REQUIRMIENTS FLOOD.MINIMUM OF Z VENTS PFR ENCLOSED AREA MOUNTED ON AT LEAST TWO DIFFERENT WALLS COLORS: STAINLESS (STANDARD) CoLORsf swNLEss (STANDARD) EXTERIOR POWDER COATED WHITE WHEAT, GRAY, AND BLACK (AVAILABLE) OITERKLR POWDER COATED WHIM WHEAT, DRAY,AND BLACK (AVAILABLE) MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY: FEMA,NFIP,ICC,&ASCE SUPPORTIVE DOCUMENTS,TB 1-08,44CFR 60.3(C)(5),ASCE 24-05 ICC EVALUATION#ESR-2074 EVALUATED UNDER AC-364 :HW x or a Fla RWO9 P11i MATERIAL REVIEW&MAINTENANCE INSTRUCTIONS Objective: When we set out to design our flood vent products, a comprehensive study was conducted to determine the most important design attributes that would be needed to insure that our customers received the best product available. Because our company started on the shores of the East Coast'of New Jersey,everyone placed durability as their number one concern. Durability: After extensive research, including review of many less expensive materials, we, choose to make the bulk of the components for our vents from stainless steel. Salt will pit stainless steel unless it is rinsed with water. We recommend that the vent be washed with fresh water twice a year. Any red rust or minor surface pitting can be removed with"commercial de-rusting solutions.". The mechanism that operates the'automatic louvers on models 1540-510, 1540- 511, 1540-514 and 1540-550 is-also entirely made from stainless steel, and water rinsing.will reduce corrosion and dirt.build-up. Prior to final inspection and testing, the louver mechanism is lubricated-with a dry film lubricant. This over the counter lubricant should be applied at minimum one time per year,or when needed. Rinse the louver mechanism,let dry,then spray all of the moving parts. Note:Wet lubricants or grease will allow dirt and sand to accumulate on the moving parts. Use only dry film lubricants. The bi-metal coil is made from highly engineered materials. The composite contains a large portion of Nickel and the finished coil is secondarily heat-treated,which forms a protective barrier to protect it from the elements. A squirt of dry film lubricant into the coil chamber during maintenance will extend its life. The floats are manufactured.from engineered plastics. An ultra-violet inhibitor was blended into the raw material before molding to insure that the sun does not degrade the functional or dimensional characteristics of the material. Insert a thin blade or a credit card into each side of the vent door's-float slot, and the door will easily push open. Rinse the float cavity; then apply a small amount of dry film lubricant on the float,where it contacts the frame. Like any product, the care one gives will determine its life. We have used the best American materials,along with the best engineering and manufacturing professionals to build our products. With just a little care, your vents will function carefree for many years. MA T VE NT www.smartvent.com•877-441-8368 ONE YEAR LIMITED WARRANTY' LIMITED, NON-PRORATED AND TRANSFERABLE Any and all product(s) as manufactured by SMART VENTS are subject to a one year limited. warranty in accordance with the following,provided that the products covered by this warranty have been installed in strict accordance with the SMART VENT®written installation instructions and in accordance with all local codes and standards. Cleaning and lubrication may be required, and is not covered by this warranty. SMART VENTS warrants to the original.purchaser or a subsequent owner of the property that parts are free from manufacturing defects for 1 (one) year from the date of purchase.Security Clips must be installed to validate warranty. Should any defect occur during the one-year period following the date of purchase, SMART VENT'®will provide a replacement for that part deemed to be defective(but not including- labor costs incurred in removing the part, installing the replacement part,or shipping). In the event of replacement according to the terms of this warranty, the warranty on the replacement part will extend.for the balance of the original warranty period,which is in effect at the time the part proves defective.- LIMITATIONS SMART VENT®shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting from or connected with painting, misuse, abuse, neglect or improper handling or storage,or installation not in strict adherence to SMARTVENP written instructions. SMART VENT°reserves the right to discontinue or modify any of its products, including color, and shall not be liable as a result of such discontinuance or modification. If SMART VENT" replaces any part under this warranty, it may substitute parts designated by SMART VENT® to be of comparable quality or price range in the event the product initially installed.has been discontinued or modified. OTHER CONDITIONS THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER ORAL OR WRITTEN WARRANTIES,LIABILITIES OR OBLIGATIONS OF SMART VENT®. PERTINENT STATE LAW SHALL CONTROL FOR WHAT PERIOD OF TIME SUBSEQUENT TO SALE A CONSUMER/ HOMEOWNER MAY SEEK A REMEDY PURSUANT TO THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR'PURPOSE. IN NO EVENT SHALL SMART-VENT®BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND, INCLUDING ANY DAMAGE TO THE BUILDING, ITS CONTENTS OR ANY PERSONS THEREIN, RESULTING FROM THE BREACH OF ANY WARRANTY SET FORTH HEREIN. NO REPRESENTATIVE OF SMART VENT® OR ITS DISTRIBUTORS OR DEALERS IS AUTHORIZED TO MAKE ANY CHANGE OR MODIFICATION TO THIS WARRANTY. Lit-006 VENT vmmsmadvent.com•877-441-8368 U.S. DEPARTMENT OF HOMELAND 5` )JRITY � Federal Emergency Management Agent = OMB No. 1660-0008 8 National Flood Insurance Program Expiration Date:November 30,201 ELEVATION CERTIFICATE Important:Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for(1)community official,(2)insurance agent/company, and(3)building owner. SECTION A—PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: KEXEL A2. Building Street Address(including Apt., Unit,Suite,and/or Bldg. No.)or P.O.Route and Box No. Company NAIC Number: 2005 NETTLES BLVD. City State ZIP Code JENSEN BEACH Florida 0 34957 A3. Property Description(Lot and Block Numbers,Tax Parcel Number,Legal Description,etc.) LOT 5, NETTLES ISLAND PROJECT SECTION 1 A4. Building Use(e.g., Residential,Non-Residential,Addition,Accessory, etc.) RESIDENTIAL A5. Latitude/Longitude: Lat.27°17'08.4" Long.80°12'53.5" Horizontal Datum: ❑ NAD 1927 ❑x NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1B 0 A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) N/A sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s)within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A8.b N/A sq in d) Engineered flood openings? ❑Yes ❑x No A9.For a building with an attached garage: a) Square footage of attached garage 112 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A9.b N/A sq in d) Engineered flood.openings? ❑Yes ❑x No SECTION B—FLOOD INSURANCE RATE MAP(FIRM)INFORMATION 61.•NFIP Community IVaJne,&Community Number B2.County Name B3. State UNINCORP 120285 ST.LUCIE Florida B4.Map/Panel 65:'50%x B6. FIRM Index B7.FIRM Panel B8.Flood B9. Base Flood Elevation(s) Number. Date Effective/ Zone(s) (Zone AO,use Base Flood Depth) Revised Date 12111 C 0312 J 02/16/2012 02/16/2012 AE 6.0 B10. Indicate the source of the Base Flood Elevation (BFE)data or base flood depth entered in Item 139: ❑FIS Profile x❑ FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System(CBRS)area or Otherwise Protected Area(OPA)? ❑Yes x❑ No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 1 of 6 OMB No. 1660-0008 ELEVATION CERTIFICATE Expiration Date: November 30,2018 IMPORTANT:In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt., Unit,Suite,and/or Bldg.No.)or P.O.Route and Box No. Policy Number. City State ZIP Code Company NAIC Number SECTION C—BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* x❑Building Under Construction* ❑ Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations—Zones Al A30,AE,AH,A(with BFE),VE,V1—V30,V(with BFE),AR,AR/A,AR/AE,AR/A1—A30,AR/AH,AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item AT In Puerto Rico only,enter meters. Benchmark Utilized: 94 77 A04 FDOT Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a)through h)below. ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor(including basement,crawlspace,or enclosure floor) 6.26 x❑ feet ❑ meters b) Top of the next higher floor N/A ❑ feet ❑ meters c) Bottom of the lowest horizontal structural member(V Zones only) N/A ❑ feet ❑meters d) Attached garage(top of slab) 5.0 x❑ feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building El(Describe type of equipment and location in Comments) N/A ❑ meters f) Lowest adjacent(finished)grade next to building(LAG) 3.8 x❑ feet ❑ meters g) Highest adjacent(finished)grade next to building(HAG) 4.0 x❑ feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs,including structural support N/A ❑ feet ❑ meters SECTION D—SURVEYOR, ENGINEER,OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor,engineer,or architect authorized by law to certify elevation information. I certify that the information on this Certiricate represents my best efforts to interpret the data available.I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code,Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? Z Yes ❑No ❑Check here if attachments. Certifier's Name License Number 877EARLE R.STARKEY 004459 Title PROFESSIONAL LAND SURVEYOR ^ Company Name ACCURIGHT LAND SURVEYING INC. Seal . Address = Herd 1501 DECKER AVENUE f = City State ZIP Code STUART Florida 34994 l4 Date Telephone Ext. 05/01/2017 772-286-7694 Copy,all p;Enf this levation Ce ca a an a attachments for(1)community official,(2)insurance agent/company,and(3)building owner. Comments(including type of equipment and location,per C2(e),if applicable) FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 2 of 6