HomeMy WebLinkAboutEnergy Calculation Form & Manual J's no3 ooc� _ RECEIVED APR 13 207 Me C®PY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business-and Professional Regulation - Residential Performance Method Project Name: KEXEL RESIDENCE Builder Name: MEL-RY CONSTRUCTION Street: 2005 NETTLES BLVD Permit Office: ST LUCIE COUNTY City,State,Zip: JENSEN BEACH,FL,34957 Permit Number: 1703-0062 Owner. Jurisdiction: Design Location: FL,Fort Pierce County:: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types (1327.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1327.30 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1129.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=20.0 1129.00 ft2 6. Conditioned floor area above grade(ftZ) 1129 b.N/A R= ft2 Conditioned floor area below grade(ftZ) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(170.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 125 a. U-Factor: Dbl,U=0.32 170.00 ft2 SHGC: SHGC=0.19 b. U-Factor: N/A ft2 12.Cooling systems - kBtu/hr Efficiency SHGC: a.Central Unit 18.0 SEER:16.00 c. U-Factor: N/A ftZ SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.190 14.Hot water systems 8. Floor Types (1129.0 sqft.) Insulation Area a.Electric Tankless Cap:1 gallons EF:0.980 a.Slab-On-Grade Edge Insulation R=0.0 1129.00 ftZ b. Conservation features b.N/A R= ftZ None c.N/A R= ftZ 15.Credits None Glass/Floor Area: 0.151 Total Proposed Modified Loads: 39.66 PASS Total Baseline Loads: 45.15 I hereby certify that the plans and specifications covered by Review of the plans and FZ91E ST9T. this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPA BY: Before construction is completed tv DATE: this building will be inspected for compliance with Section 553.908 t 0 I hereby certify that this building, as designed, is in co lance Florida Statutes. with the Florida Energy CoG'OD,y ;�RVy OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 3/29/2017 6:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: KEXEL RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1129 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: MEL-RY CONSTRUCTION Rotate Angle: 0 Street: 2005 NETTLES BLVD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: JENSEN BEACH, Family Type: Single-family FL, 34957 New/Existing: New(From Plans) Comment: Y'r CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1129 9032 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 LAUNDRY 77 616 No 0 1 Yes Yes Yes 2 M BATH 90 720 No 0 1 Yes Yes Yes 3 CLST 2 22 176 No 0 1 Yes. Yes Yes 4 BED 2 121 968 No 1 1 Yes Yes Yes 5 MASTER BEDROO 144 1152 No 1 1 Yes Yes Yes 6 M CLST 24 192 No 0 1 Yes Yes Yes 7 BATH 2 56 448 No 0 1. Yes Yes Yes 8 HALL 32 256 No 0 1 No Yes Yes 9 LIVING ROOM 275 2200 No 0 1 Yes Yes Yes 10 KITCHEN 167 1336 Yes 0 1 Yes Yes Yes 11 BREAKFAST 121 968 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation LAUNDRY 22.5 ft 0 77 ft2 --__ 1 0 0 2 Slab-On-Grade Edge Insulation M BATH 17.8 ft 0 90 ft2 _--- 1 0 0 3 Slab-On-Grade Edge Insulation CLST 2 2ft 0 22 ft2 ____ 1 0 0 4 Slab-On-Grade Edge Insulation BED 2 lift 0 121 ft2 1 0 0 5SIab-On-Grade Edge Insulation MASTER BEDRO 12 ft 0 144 ft2 ____ 1 0 0 6 Slab-On-Grade Edge Insulation M CLST 2ft 0 24 ft2 __e 1 0 0 3/29/2017 6:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 7 Slab-On-Grade Edge Insulation BATH 2 13 ft 0 56 ft2 __e 1 0 0 8 Slab-On-Grade Edge Insulation HALL 1 ft 0 32 ft2 ___ 1 0 0 9 Slab-On-Grade Edge Insulation LIVING ROOM 35 ft 0 275 ft2 __e 1 0 0 f 10SIab-On-Grade Edge Insulation KITCHEN 22 ft 0 167 ftZ __e 1 0 0 11SIab-On-Grade Edge Insulation BREAKFAST 28.5 ft 0 121 ft2 __-- 1 0 0 w ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch �/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1223 ft2 0 ft2 Light 0.6 No 0.9 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1129 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) LAUNDRY 20 Blown 77 ft2 0.1 Wood 2 Under Attic(Unvented) M BATH 20 Blown 90 ft2 0.1 Wood 3 Under Attic(Unvented) CLST 2 20 Blown 22 ft2 0.1 Wood 4 Under Attic(Unvented) BED 2 20 Blown 121 ft2 0.1 Wood 5 Under Attic(Unvented) MASTER BEDRO 20 Blown 144 ft2 0.1 Wood 6 Under Attic(Unvented) M CLST 20 Blown 24 ft2 0.1 Wood 7 Under Attic(Unvented) BATH 2 20 Blown 56 ft2 0.1 Wood 8 Under Attic(Unvented) HALL 20 Blown 32 ft2 0.1 Wood 9 Under Attic(Unvented) LIVING ROOM 20 Blown 275 ft2 0.1 Wood 10 Under Attic(U nvented) KITCHEN 20 Blown 167 ft2 0.1 Wood 11 Under Attic(Unvented) BREAKFAST 20 Blown 121 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar BelowP-NIall le Et In Et In Area P-1/allie EmCtinn Ahqnr 1 NE Exterior Concrete Block-Ext InsuILAUNDRY 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0 2 W Exterior Concrete Block-Ext InsuILAUNDRY 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 3 NE Exterior Concrete Block-Ext Insul M BATH 4.1 13 11 8 0 111.3 ft2 0 0 0.6 0 4 E Exterior Concrete Block-Ext Insul M BATH 4.1 4 0 8 0 32.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block-Ext Insul CLST 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 6 W Exterior Concrete Block-Ext Insul BED 2 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 7 E Exterior Concrete Block-Ext InsdMASTER BE 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 8 E Exterior Concrete Block-Ext Insul M CLST 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 3/29/2017 6:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 9 S Exterior Concrete Block-Ext Insul BATH 2 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 10 W Exterior Concrete Block-Ext Insul BATH 2 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 11 E Exterior Concrete Block-Ext InstilIVING ROO 4.1 23 0 8 0 184.0 ft2 0 0 0.6 0 12 S Exterior Concrete Block-Ext InsLUIVING ROO 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 13 N Exterior Concrete Block-Ext Insul KITCHEN 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 14 W Exterior Concrete Block-Ext Insul KITCHEN 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0 15 E Exterior Concrete Block-Ext Insi9REAKFAST 4.1 8 0 8 0 64.0 ft2 0• 0 0.6 0 16 SW Exterior Concrete Black-Ext Ins51REAKFAST 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0 17 W Exterior Concrete Block-Ext Inst8REAKFAST 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W 6 Metal Low-E Double Yes 0.32 "0.19 15.0 ft2 1 ft 0 in 1 ft 4 in None None 2 E 7 Metal Low-E Double Yes 0.32 0.19 15.0 ft2 1 ft 0 in 1 ft 4 in None None 3 W 10 Metal Low-E Double Yes 0.32 0.19 12.0 ft2 1 ft 0 in 1 ft4 in None None 4 E 11 Metal Low-E Double Yes 0.32 0.19 30.0 ft2 1 ft 0 in 1 ft4 in None None 5 W 14 Metal Low E Double Yes 0.32 0.19 12.0 ft2 1 ft 0 in 1 ft 4 in None None 6 W 14 Metal Low-E Double Yes 0.32 0.19 20.0 ft2 1 ft 0 in 1 ft4 in None None 7 E 15 Metal Low-E Double Yes 0.32 0.19 20.0 ft2 1 fit 0 in 1 ft 4 in None None 8 SW 16 Metal Low-E Double Yes 0.32 0.19 4.0 ft2 1 ft 0 in 1 ft 4 in None None 9 SW 16 Metal Low-E Double Yes 0.32 0.19 6.0 ft2 1 ft 0 in 1 ft 4 in None None 10 SW 16 Metal Low-E Double Yes 0.32 0.19 12.0 ft2 1 ft 0 in 1 ft 4 in None None 11 SW 16 Metal Low-E Double Yes 0.32 0.19 24.0 ft2 1 ft 0 in 1 ft4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA Eq LA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1053.7 57.85 108.79 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts V 1 Electric Strip Heat None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:16 18 kBtu/hr 540 cfm 0.8 1 sys#1 3/29/2017 6:59 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Exterior 0.98 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage * Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply-- —Return— Air CFM 25 CFM25 HVAC# v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 125 ft2 Attic 13 ft2 Default Leakage Attic (Default)c(Default)c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb Mar Apr May Jun Jul [X]AugX]Se Oct Nov Dec HeatinJan Feb Mar f Apr f May Jun Jul [ ]Au [ ]Sep f Oct Nov Dec VentingJan Feb Mar [X]Apr [ May Jun Jul [ ]Aug [ ]Se [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/29/2017 6:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: KEXEL RESIDENCE Builder Name: MEL-RY CONSTRUCTION Street: 2005 NETTLES BLVD Permit Office: ST LUCIE COUNTY City,State,Zip: JENSEN BEACH,FL,34957 Permit Number: 1703-0062 Owner: Jurisdiction: Design Location: FL,Fort Pierce l COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity �. spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 3/29/2017 6:59 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 88 The lower the EnergyPerformance Index, the more efficient the home. 2005 NETTLES BLVD, JENSEN BEACH, FL, 34957 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1327.30 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? No. 10.Ceiling Types Insulation Area a.Roof Deck(Unvented) R=20.0 1129.00 ft2 6. Conditioned floor area(ft2) 1129 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.32 170:00 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 125 SHGC: SHGC=0.19 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 18.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average.SHGC: 0.190 8. Floor Types Insulation Area 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 1129.00 ft2 a.Electric Cap:1 gallonsEF:0.98 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits None I certify that this home has complied With the Florida Energy Efficiency Code for Building �xE s�AT Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant featur 1/111 Builder Signature: Date: Address of New Home:Z�5 �?/Z Y� �� City/FL Zip:.TffW_5�UtX/ COD��v *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/29/2017 6:59 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 1 .._� ]7_t• g1 1p3� N• 8x ay 9 'a C'1 S Sy"�g a�a !• \I A u„a•k, I %i ✓� y u� O o..a r.—. t rR + H 1g t.4 Z 11• �6 Pw Z I gg .i .��oo- >; � "' � \t I � �if xti i I ss $r 2R Y tm< a Via D2OA I ' Lis 'r e'.e• T'+' ' e �s"m•-C 70'-Y jOP O p5y. ?. P ? F !3 =¢¢�" p m St m�^r n ;pea Lwry�' yrtj -n 43 t , , 3 , I I 1 1 a -= q��6� 2a $ �� . '\,e 3� Ff^�g41•{'°a~AE O <tlDzo mmnm >F g< DD�DYVD rw 3t7@ � a UA3 rr I r9 4 4 9 4 9 aasrrE ,ni r� "•"• M "^-"•^.5 � R$« 7 114« «$9 g m 9 9%9 q p4}t««Ip3 Q�w H 4w a, sN�«y •'D5 $ Alp! °i �aRE, g 1 es °in OAm rTb Q e a ao a m$8gg5 � 8 . i�.� pil9i Cad 59$yF ,$Sfig � 9S j 'Ailod.8 '2 $ $ R $ Zo 1n E $ $$ $ � 4 9 R q6 iA °q '$ Yg 2grA�g o 5 O (f} ..Ss-.0 y y a nq 8�6 g4$pP f S gi5�'@ ' $@ � P 3 C ,a ,� C° °• E > E '9d q i is�y n W a i `t - ;� { j Vo�q 3L gggh Dr$ O 8 p »° iffy @ Cep ' aa'g g �g LS€Aj S�R�Sj ��SS gQ : I n td u c « 0 6- -�=y t « s °A Itgi S P• o*A V-6 16� �r R F d B sro>iq �E $ g«yA I i9 714 t � ! q qm a« m@ qg$ �$ 2 s �q�g � �' $�� �$n lilt M3 ; a$�X � a9naaSaa as 6 a® i x HgS Z a x I 81,121,12121ii all Is1 11 1AIrl III 1 1 40 M M > aY`J%aayyyae] wa- - _ ('y n oo g� � 51I' � �If f De%%�%SPPPe:arr}FF..]aa• •�pp� � $ r � p�' ����i >tA��gi{��M - s se as a a a a a a A a af IDO Ell XsDa s cr i r PI ! ! I ! lIIPP P P� 7U °4w $$ -$ °0°$09 SaSSSaaSSaa S S aS Ua g R � ' ,€�ifa t 713 € P 6'FI" -sa! i a I gf. No Mt r 9 P t t 115 '1 1m$ n $$ Z -- " n letF— t 11 � \i.9 -i>7`-_-^-lt °St. P n RESIDENCE FOR: KEXEL LOCATION: LOT 19 Nettles Blvd. Jansen Beach, i ME St, Lucie Countg, Florida Corrsrn crioN ixc. n_ m Braden ! Braden AIA, PA oau Crean, Ex.vnon.. m Arch,-t.-Planners wmtttlNLtl tiAL'IWD711 2-N-St 1 A{�} 4M S.S.C-1,AY.N. MAINOPFICR Oake7724IM479 Oraan-by. P 1 11 U,(112)281-8298 109a7POCMNtRt Pat771d79.9440 C.C.U. _ ©.0 a Pen,11127 201-9293 1..ends 04]4977 9-0"039412 Ch.ekad by, E-aw:t:bradenan eanea9t.n.t rrvwW24.00M LICSONCPO a INSUR90 attwt PL 996 CAAC00002 D.R.B. Project Summar Job: - - Wrightsoft® Date: Feb 23,2017 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466.6796 Email:QUICKCALCS@f10L.COM • • rmatio H For. KEXEL RESIDENCE, MEL-RY CONSTRUCTION LOT 19 NETTLES BLVD, JENSEN BEACH,.FL Notes: f eSign • • Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 18393 Btuh Structure 11444 Btuh Ducts 2539 Btuh Ducts 1485 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20932 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 12283 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2587 Btuh Ducts 1001 Btuh Heating Cooling Central vent 0 cfm) 0 Btuh Area(ftp 1129 1129 Equipment latent load 3588 Btuh Volume(ftp 12410 12410 Air changes/hour 0.45 0.23 Equipment total load 15871 Btuh Equiv.AVF(cfm) 93 48 Req. total capacity at.0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM Model Cond RA1618AJ1NA AHRI ref Coil RH1T2417STANJA AH R I ref 7940565 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 5.1 kW Sensible cooling 12600 Btuh Heating output 17492 Btuh Latent cooling 5400 Btuh Temperature rise 27 OF Total cooling 18000 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.029 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. twrightsoft® 2017-Feb-2313:58:04 .+— Right-Suite®Universal 2017 17.0.08 RSU08101 Page 1 �'� EADocumnets%Wrightsoft HVAC\KEXEL RESIDENCE.rup Calc=MJ8 Front Door faces: S -wrightsofr Right-JO Worksheet Entire House Date: Feb 23,2017 QUICK CALCS, INC. By: 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name Entire House LAUNDRY 2 Exposed wall 165.8 ft 22.5 ft 3 Room height 11.0 ft 8.0 ft heat/cool 4 Room dimensions 1.0 x 77.0 ft 5 Room area 1129.0 ft2 77.0 ft' Ty Construction U-value Or HTM Area (ftp Load Area (ftp Load number (Btuh/ft;°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W _ 13A-� 76 70 580 153_�._-�0 _-__Y0 0 W 13A�3ocs _0.143 ine 4.00, 219 211- 211 846 _462 100__— 100 401 219 1:2 - f 3A�ocs 0.143 a 4.00 X219 578 514 2057 1124 y� 0 0 0 0 2 glazing,clr low=e 0.320 a 8.96 23.06 45 0 403 1038 0 0 0 0 11 L-G_2 glazing,WGrX23.06 _-:19,w Q ;173 444_...., Q-- � ._.0__--Q 0 W __- 13A-4ocs -��0.143 s -_4,00_-_219 208 208 833_- _ 455 0_ 0 0 0 W 13A 46cs 0:143 sw 4.00" " .21'9 175'- 129 518 ^.'-283 0 _ _ _..0 0 .0 2 glazing,clr,low-e 0.320 sw 8:96 . .1254 4 2 34 48,x < 0 .0 0 ``0 2 glazing'cle low-e 0.320 -sw 8.96 15:24 6,° 2 55 94 0 0 - 0 0 2.glazmg,clr.low--e._._.._ 0:320 sw.--. .8.96»__._.17:05 � 224 ,.'____2 x.215 _ 409 {.:._'.�_0 0 0 2 glazing,,clr love e° 0 320 sw 8:96 16.80 12 2 108 199 0 0 13A-4ocs 0.143 w 4.00 2.19 598 539 2157 1178 80 80 320 175 2 glazing,clr low-e 0.320 w 8.96 23.06 15 0 134 346 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 23.06 24 0 215 553 0 0 0 0 2 glazing,clr low-e 0.320w 8.96 23.06 20 0 183 470 0 0 0 0 C_ 16A-30md_ p__ _0. 032 11__:l- 0,90. 2 24 _ 1129 129 ;'1012 X2529 -77_ �77 69 F _--22A4ph___.____. _. 1.358 __. 38,02-_ 4:09-_ 1129.._� _ 6306 0_.._._ --T7 ---�-_23 m_856 _-•-----0 - - - _ .,.,.m.u,.n........_...., ......._....,.:.,..w.,....... .....A_ --........,..>:..:».,.....:7-___... _._.,.v...iK ae..re b...t.._._....ee__... ...._..__.�:,_:..�:._..._�_,....u,......,.�,..:a..........::.....».,.,._... ..,..:............__ - ._.....,..._e_., ... .,...�.>_. a..c..._e:.._ ._ _—.... M1 6 c)AED excursion 183 -38 Envelope loss/gain 15529 9970 1646 529 12 a) Infiltration 2864 784 280 77 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 18393 11444 1927 606 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 85 39 14 Subtotal 18393 11444 2011 645 15 Duct loads 14% 13% 2539 1485 14% 33% 278 213 Total room load 20932 12929 2289 858 Air required(cfm) 600 600 66 40 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. � A- wrigi�tsoft' 2017-Feb-23 1 Right-Suite®Universal 2017 17.0.08 RSU08101 g Pagel E:\Documnets\Wrightsoft HVAC\KEXEL RESIDENCE.rup Calc=MJ8 Front Door faces: S -r-wrightsoft® Right-J®Worksheet Job: Entire House Date: Feb 23,2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466.6799 Fax 772-466-6796 Email:QUICKCALCS(a@,AOL.COM 1 Room name M BATH CLST 2 2 E)osed wall 17.8 ft 2.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 90.0 ft 11.0 x 2.0 ft 5 Room area 90.0 ft' 22.0 ft' Ty Construction U-value Or HTM Area (ftp Load Area (ftp Load number (Btuh/fV°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) ^„ Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W7---1_43A4oas _-__ 0 143-n 4.00. 219_-__._ 0.w___0_ 0 0 R 0.143-_ne 4.00 219- 111,___ 111___ _445-_ 243_ 0__- _ 0 0 _..__ . WI - 13A-4ors 0.143 a 4.00 2.19 32 32 128 70 .., 0 0 0 A. 2 glazing,cir low-e 0.320, e 8.96 23.06 0 0 0 0 0 0 0 0 11 2.glazing,clr I_ow-e __ 0.320�e 8,96. 23:06 0 _0_--,__ 0_ 0-_0 w - 13A-4ocs _._.------0.143 s__-_4.00.._. .219 9._-_--0 ----0 -----0- --0- --0 -.Q.__._.. _0 W 13A-4ocs '0.143 sw 4.00 -219 "?o 0 0 0 0 0 0 0 2glazing,Or']Dx-e 0.320 sw 8.96 F 12.54 ,0; 0 0 0 <a 0 0 0 0 2 glazing,cir 1m#-e JOMO °sw 8.96 15.24 0' 0 0 0' 0 •;0 0 0 2.glazing,_clraoinr�_ _-_ 0.320_sw:.__ 8:96 16:60 0' 0 0 0 0 0 0 0 glazing,q1r1ow-e 0:320 sw �8,96, _ 17.05_ _0.__-___0 ____ 0_ _._.- _0 -0___ .0 0 13AVh -4ocs 0.143 w 4.00 219 0 0 0 0 16 16 64 35 2 glazing,clr low-e 0.320 w 8.96 23.06 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 23.06 0 0 0 0 0 0 0 0 VVVVVV,,,���VVVVVV 2 glazing,-clr low-e 0.320 w 8.96 23.06 0 0 0 0 0 0 0- - 0 C__ 16A_30md.�� m___ ��..:0032 - 0:90 224 _:90..__.__99. .__-81..,______202 F, MAph, 1.358 38;02 0.00 90 18 __.._, 678 -_ 0_.,.,. ._mom_.._ 2 76. ._.._._._0 -__. 6 c)AED excursion -34 -5 Envelope loss/gain 1332 481 160 79 12 a) Infiltration 223 61 25 7 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1555 542 185 86 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 15 7 -185 -86 14 Subtotal 1570 549 0 0 15 Duct loads 114% 33% 217 181 14% 33%1 0 0 Total room load 1787 730 0 0 Air required(cfm) I 1 1 51 34 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft' Right-Suite®Universal 2017 17.0.08 RSU08101 2017-Feb-23 13:58:04 IZ& Page 2 E:\Documnets\Wrightsoft HVAC\KEXEL RESIDENCE.rup Calc=MJ8 Front Door faces: S 77 wrightsoft, Right-JO Worksheet Job: Date: Feb 23,2017 Entire House By. QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fa:c 772466-6796 Email:QUICKCALCS@40L.COM 1 Room name BED 2 MASTER BEDROOM 2 Exposed wall 11.0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 11.0 x 11.0 ft 12.0 x 12.0 ft 5 Room area 121.0 ft2 144.0 ft' Ty Construction U-value Or HTM Area (ftp Load Area (ftp Load number (Btuh/ft2"F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool -_.- 6 Wim. 13A�3ocs _.._ _ _0143 0 __..4.00 219 0. 0 DO0 _0 n0 W _13A-flocs0 143 _ne. 4.00 219 0 0 0 0 0_ .0 _ 0 _ .0 13A�ocs. 0143_ 2 glazing,clr low-e 0.320 a 8.96 . .23.06 0 0 0 0 15 0 134 346 11 W _2 glazing,_cir_low_e-_----..___0.320_e -_8:96.___23.06__ =0 _ _.-0____ 0.-_-"---0___ 0 0_._-_w0_-_�- 0 13A-4ocs- _- -----._0.143 s_ 4._00.___-..219 _0--�__- 0_ 0._ 0 _ �0___ 0 �0 0 W 13A-4ocs 0.143 sw 4.00 2.19 0 0 10 0 0 0 - 0 0 2 glazing,clrlow-e 0.320 sw 8.96 12 .54 0, 0, 0 0 0 0 0 0 2glazing,'olrlow-e 0.320 sw 8.96 -15.24 °;0 0. 0. 0 °,' 0 0 0 - ' -Q ..2 glazing„clr row-e____ -,---"0;320__sw_-.__-_8:86 17.05____.�o _.____-0_ __0__ ____0 ----__0 __ __.__o__'___0' Vh13A4ocs 0.143 w 4.00 2.19 88 73 292 160 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 23.06 15 0 134 346 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 23.06 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 23.06 0 0 0 0 0 0 0 0 C___. _.0.90 2.24 121__-_J,2-1._ 108_ 271, :: -__144_. 14 __4_ 129__.��,_323, F -_,e---22Aftoh,� __....,w:..1y`358 3802 _000 21. ___11 418. .__.._--0 �44 12 W _v456 __.,..... .�0 6 c)AED exursion 92 -43 Envelope loss/gain 953 8691 1044 803 12 a) Infiltration 137 37 149 41 b) Room ventilation 10 0 0 0 13 Internal gains: Occupants @ 230 1 230 2 460 Appliances/other 0 0 Subtotal pines 6 to 13) 1090 1137 1193 1304 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 90 52 101 63 14 Subtotal 1180 1188 1294 1367 1151 Duct loads 14% 33%1 163 392 14% 33% 179 451 Total room load 1343 1580 1473 1817 Air required(cfm) 38 73 42 84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft' 2017-Feb-23 13:58:04 Right-Suite®Universal 2017 17.0.08 RSU08101 age 3 E:\Documnets\Wrightsoft HVAC\KEXEL RES]DENCE.rup Calc=MJ8 Front Door faces: S -r-wrightsoft Right-JO Worksheet Job: Entire House Date: Feb 23,2017 BY: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax:772466-6796 Email:QUICKCALCS@AOL.COM 1 Room name M CLST BATH 2 2 Exposed wall 2.0 ft 13.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 12.0 x 2.0 ft 7.0 x 8.0 ft 5 Room area 24.0 ft' 56.0 ft' Ty Construction U-value Or HTM Area (ftp Load Area (ftp Load number (Btuh/f?°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool _- w _ _ _- - is 6 !N 13A4ocs _ _ - _w0 143:._n - 4_00_. 2�9___.__ 0 ___ 0_____ut.__0_ _.-_0_ __._ Q 0. ___0__._ _. - 1N13A-4ocs_ 0.143 ne 4,00 __ _219 _ ._0 0 0 0- 0 0 0 0. W 13A11ocs, 0.143 7 e- 4.00 2:19 16 ___16 u, 64--____._35 _ 7-0_ 0_._.__-0 -0 2 glazing,clr-Iow-e 0.320 a 8.96 23.06 0, 0 0 0 0 0 0 0 11 � _2,glazi-9 Gr lower_____M,_0.320 a 8.96.__23.06____..0 Q Q - 0. 0_---_ 0 W 13A-4ocs 0.148 s 4.00 219 0 0__ __0____0 40 40 160 88 W� 13A-4ocs. ---- ,-0.143 sw' -- 4.00 .-Y219---SMO 0 _ 0 0 -0_-. 0.�e. 0- -..0 2 glazing,.clr low-e -0.320 sw 6.96, 12.54 0, 0 �_0 0 0 �0 0 0 2 glazing,�clr.lovv-e" 0.320 'sw' 8.96. �, 15.24 0; 0 .`°"0 0 0 o,` 0 �`0 2glazing,clr`love-e' .0;320 �sw 8:96 16.60 :0' 0 -0 0 ,` 0 0°, 0 0 .2.glazing,_clrJow-e____ 0:320_sw_____.8.96 ..17.05 _0-:--"_0-_-.__ 0 __.._-0.__-0 13A flocs 0.143 w 4.00 219 0 0 0 0 64 52 208 114 2 glazing,clr low-e 0.320 w 8.96 23.06 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 23.06 0 0 0 0 12 0 108 277 2 glazing,clr low-e-� 0.320 w 8.96 23.06 0 _0 _ 0 _ 0 0 0 0 0 J_ Oma-__,_...._ __. _0032. _----0.90. _ 2.24___ 24____W_ 24 ..v 22 __. _54 __56__- _56 F 22A tph_ 1.358 38.02 0.00 24 2 76 0 56 13 494 0 77_ , _ - 77 - - - 6 c)AED excursion -6 85 Envelope loss/gain 162 83 11020 688 12 a) Infiltration 25 7 162 44 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 187 90 1182 733 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -187 -90 10 25 14 Subtotal 0 0 1193 757 15 Duct loads 14% 33% 0 0 140/6 33% 165 250 Total room load 0 1 0 1357 1007 Air required(cfm) 1 0 0 39 47 Calculations approved WACCA to meet all requirements of Manual J 8th Ed. �T wrightsoft' Ri ht-Suite®Universal 2017 17.0.08 RSU08101 2017-Feb-23 13:58:04 A C.� 9 Page 4 E:\Documnets\Wrightsoft HVAC\KEXEL RESIDENCE.rup Calc=MJ8 Front Door faces: S +11-wrightsoft® Right-JO Worksheet Job :Date:House Date: Feb 23,2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name HALL LIVING ROOM 2 Exposed wall 0 ft 35.0 ft 3 Room height 8.0 ft heattcool 14.0 ft heat/cool 4 Room dimensions 4.0 x 8.0- ft 1.0 x 275.0 ft 5 Room area 32.0 ft' 275.0 ftz iA Ty Construction U-value Or HTM Area (ftp Load Area (ftp Load number (Btuhlf:2°F) (Btuhlft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 1 6 W:_ 13k-flocs ._ 0 743 n 4 00.= 219 ,.....r...:.0 0==D'-._ _.._.0_.' . _u 0 a W 13A-4ocs 0 143 ne 4.00 2.19 0 0 0 0 0 0 0 0 W 13A�tocs x _.� 0143 `e' ,4 0 I� 219 0 �, 0 ;� 0 0 322 292 1169 G639 2 glazing clr low-e. 0 320 a 896 23 wo 0 0 0 0 30 .' 0 269 692 2 glazing,clr low-e,-_ 9f320 a , 8:96...,..23 06.�,..,vz0.__ o 0 ..e:0 _ =0_.__._ _ _ 0 __,__ 0, W_ 13A-4ocs 0 143 s� 4.00 _ 2.19 00 0 0 r 168 168 673 368 T 13A�ocs� 0 143 �sw 4.00 � 219 �0 �_� 0 � �0 ,.0" 0 0 0 0 2 glazmg,:clr Iowa O)320 sw 8"96, .1254 0 0 0 9, 0 0 0 0. a2glazmg ciclow�, �4:320'sw X8:96'=° 15:24 ,v, 0 0 0 0 ��0 0 0- 2 glazing,clr low a„ 0 320`sw 8.96 16.60 0 0 0 0 0 0 0' 0' 2.glazing,clr low e: _ 0:320.dsw<. __= 89fi �1Z.05 ..,.,...M. .0_v__ D _0 _ .__0 - 0,_ _t. 0 0_____ 0: N13A4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 23.06 0 0 0 0 0 0 0 0 2 glazing;dr low-e 0.320 w 8.96 23.05 0 0` 0 0 0 0 0 0 2 glazing clr low-e 0.320 w 8.96 23.06 0 _ 0 0 0 0 0 0 0 C, 16A 30md: -; 0 032 -_,_0.94 F 22A tph. ___ _1.358 38,02 0 00 32 0 0 0 ..m 275 35 .. _ ..... _ �..,.m...na..._tx� #'. -.-.J..�4mn.w.,.. ....._.t � _...w... � m....... � ......w_.,,._... W..2's..?fi.. .�_a,.�. ..,.......,. s . 77 �.,�. .................x..,.. ._„., .....5 _�.-. ..1,1'T..ea _ _._.. "r..........� 77-� 77 _ _ 77,77-11,71 a H 6 c)AED e)cursion 4 -76 Envelope loss/gain 29 671 3688 2238 12 a) Infiltration 0 0 762 209 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 29 67 44501 2447 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -29 -67 93 45 14 Subtotal 0 0 4544 2492 15 Duct loads 14% 33%1 0 0 149/o 0% 627 0 Total room load 0 0 5171 2492 Air required(cfm) 01 01 1 148 116 Calculations approved by ACCA to meet all requirements of Manual.J 8th Ed. wr llghtsOft- 2017-Feb-23 13:58:04 Right-.Suite®Universal 2017 17.0.08 RSU08101 Page 5 �� E:\Documnets\Wrightsoft HVAC\KEXEL RESIDENCE.rup Calc=.MJ8 Front Doortaces: S wrightsoft° Right-J®Worksheet Job: Entire House Date: Feb 23,2017 QUICK CALCS, INC. By. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:OUICKCALCS@AOL.COM 1 Room name KITCHEN BREAKFAST 2 E;Vosed wall 22.0 ft 28.5 ft 3 Room height 14.0 ft heat/cool 14.0 ft heat/cool 4 Room dimensions 1.0 x 167.0 ft 1.0 x 121.0 ft 5 Room area 167.0 ft' 121.0 ftz Ty Construction LI-value Or HTM Area (ftp Load Area (ftp Load number (Btuh/ft'°F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool Y 6 W , 13A-4ocs ' _� :L 0 143_.,�n 4.04 "219 0__ 70 ..,w 280 153 _ ..0 __ ` 0_._ _v M. 0: W _ 13A-4ocs . � ._0 143. ne 4.00 _ 2. .0,19._ . 0 _ 0 0. _ d-_� W 13A-ocs _ -y_ 0.148 a 4.00 2.19 "'o 0 0 0 112 93 371 203 2 glazing,clrlow-e 0.320 a 8.96 `23.06 0 0 0 0 0 0 0 0 11 6_2 glazing;clr low_e______Q320 a -8.96 23.06--_.0 -__..-0_____:_0_._____0_-_.s19 _0 W 13A-4ocs 0.143 s 4.00 219 0 0 0 0 0 0 0 0 W 13A-0dcs _ 0.143 aw .4.00' '-2.19 0_---0 ---0 175 129 -� '518 ---W283' 2 glazing,'cir<°low-e 0.320 sw 8,96 12.54 0 0 "0 0 4 2 3448. 2 glazing,clr,'low-e p320 sw 8.96 - 15.24 P O°'° 0 - `.0 0 a 6 <<2 55 ,94� 2 glazing,&.low-e 4:320 sw 8.96_ 16-60 ,0 0 0. 0"""' 12 _2 '108 "'199 .2.glazing,'.c1r_low_-e____�_0.320-sw-'--8.96.. _, __0 17.05 .1 ____0 a.__� 0: _ __0_ __24_____ 2 _215_ 409. 13A-4ocs 0.143 w 4.00 219 238 206 823 450 112 112 448 245 2 glazing,clr low-e 0.320 w 8.96 23.06 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.320 w 8.96 23.06 12 0 108 277 0 0 0 0 2 glazing,clr low-e 0.320 w 8.96 23.06 20 0_ 183 470 0 0 0 0 ____x_,.167_�____167 __. 150. 374==:121-- a 121 F 22A tph H 1.358 - 38.02 0.00 167 22 837 0 121. 29 1084 0 _ - 6 c)AED excursion 223 -12 Envelope loss/gain 2380 1948 3115 2185 12 a) Infiltration 479 131 621 170 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2859 2079 3736 2355 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 12 0 0 14 Subtotal 2864 2091 3736 2355 15 Duct loads 14% 0% 395 0 14% 0% 516 0 Total room load 3260 2091 4252 2355 Air required(cfm) 193197 122 109 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- Right-Suite®Universal 2017 17.0.08 RSU08101 2017-Feb-23 13:58:04 age 6 E:\DocumnetskWrightsoftWACkKEXELRESIDENCE.rup Calc=MJ8 Front Door faces: S ., 9 ® Duct System Summa Job: wri htsoft y Date: Feb 23,2017 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For. KEXEL RESIDENCE, MEL-RY CONSTRUCTION LOT 19 NETTLES BLVD, JENSEN BEACH, FL r Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply/return available pressure 0.500/0.500 in H2O 0.500/0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 600 cfm 600 cfm Total effective length(TEL) 166- ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln(ft) Trunk BATH 2 c 1007 39 47 1.000 4.0 Ox 0 VIFx 18.9 115.0 st2 BED 2 c 1580 38 73 1.000 4.0 Oxo VIFx 10.6 115.0 SO BREAKFAST h 4252 122 109 1.000 5.0 Oxo VIFx 30.6 135.0 st3 KITCHEN c 2091 93 97 1.000 5.0 Oxo VIFx 20.2 135.0 st3 LAUNDRY h 2289 66 40 1.000 4.0 Oxo VIFx 13.3 115.0 st1 LIVING ROOM h 2585 74 58 1.000 4.0 Oxo VIFx 17.8 115.0 st2 LIVING ROOM-A h 2585 74 58 1.000 4.0 Oxo VIFx 25.8 115.0 st2 M BATH h 1787 51 34 1.000 4.0 Oxo VIFx 10.6 115.0 st1 MASTER BEDROOM c 1817 42 84 1.000 5.0 Oxo VIFx 15.0 115.0 st2 • • Trunk Detail Table r Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 215 206 1.000 806 7.0 0 x 0 VinlFlx st2 st2 Peak AVF 445 453 1.000 831 10.0 0 x 0 VinlFlx st1 Peak AVF 155 147 1.000 791 6.0 0 x 0 VinlFlx BoWitalic values have been manually overridden 1 wri htsoft� 2017-Feb-2313:58:05 9 Right-Suite®Universal 2017 17.0.08 RSU08101 Page 1 AMA EADocumnets\Wrightsoft HVAC\KEXEL RESIDENCE.rup Calc=MJ8 Front Door faces: S Retdrn Branch Detail Tible Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 600 600 0 0 0 0 Ox 0 VIFx i r 1 wri htsoft° 2017-Feb-2313:58:05 9 Right-Suite®Universal 2017 17.0.08 RSU08101 Page 2 ArCA E:\Documnets\Wrightsoft HVACIKEXEL RESIDENCE.rup Calc=MJ8 Front Door faces: S