HomeMy WebLinkAboutProduct Approval 2/7/2017 ) Florida Building Code Online
Business & ProfessionalRegulation
1OW E - -
BCIS Home Log In User Registration I Hot Topics I Submit Surcharge Stats&Facts I Publications I FBC Staff I BCIS Site Map I Links I Search
Florida
Product Approval
USER:Public Userdlopr
8 � Product Approval Menu>Prl duct or Application Search>Application List>Application Detail
I I
OFFICE OF THE FL# FL16107-R9
Application Type Revision
Code Version 2 114
Application Status Approved
Comments
Archived O
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd.
Mason, OH 45040
(513)770-6062
mwesterfield@clopay.com
Authorized Signature Scott Hamilton
shamilton@clopay.com
Technical Represent Iative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
I Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
i Compliance Method) Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
O Evaluation Report-Hardcopy Received
Florida Engineer orl Architect Name who developed Scott Hamilton
the Evaluation Report
Florida License PE-63286
Quality Assurance Entity Intertek Testing Services NA,Inc.
Quality Assurance Contract Expiration Date 12/31/2028
Validated By Gary Pfuehler
O Validation Checklist-Hardcopy Received
Certificate of Independence FL16107 R9 COI Certification of Independence of Validation Entity-
Gary Pfuehler.pdf
FL16107 R9 COI Statement on Independence of Evaluation Entity-
; ScottHamilton 120424.pdf
i
i
Referenced Standard and Year(of Standard) Standard Year
ANSI/DASMA 108 2005
ANSI/DASMA 115 2005
i
ASTM E1886 2005
ASTM E1996 2009
ASTM E330 2002
TAS 201 1994
TAS 202 1994
TAS 203 1994
https://w".floridabLiiding.orgtpr/Pr_app dtl. spx?param=wGE\tXQwtDgvyf4ngAXh109aYpgetu2%2f5piPViHU22RIytcEPY2EAeAp/o3d%3d 1/5
I
2r7/2017 � � Florida Building Code Online
Equivalence of Product Standardso
f7
V-
Certified By p,
Sections from the Code
'o x�
i
Product Approval Method Method 1 Option D
Date Submitted 10/14/2016
I
Date Validated 10/20/2016
Date Pending FBC Approval 10/21/2016
Date Approved 12/14/2016
Summary of Products
Go to Page Page 2/3
FL# Model,Number or Name Description
16107.21 21 W8-16 DSIE-lF471: GD2SP, Double-skin Insulated EPS (exterior skin 27 ga. min.; interior
GR2SP, GD21_13, GR2LP,AR2SP, skin 27 ga. min.) Double-Car(97'to 167'wide)
AR2LP, ED2SP, ED2LP,4302, HDGC, WINDCODE®W8 Garage Door with Optional Impact-Resistant
6202,MFC68,4305, HDGR, 6205, Utes
SFR68, MFR68
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16107 R9 II 104786-RevO4-sioned.Ddf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +46 PSF/-52 PSF Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R9 AE CBPC 130214-A.Ddf
doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No
resistant(large missile impact).
16107.22 22 W6-09 DSIE-1F171: 4400,4401, Double-skin Insulated EPS (exterior skin 27 ga. min.; interior
4301,4300,4301,4310, HDG, skin 27 ga. min.) Single-Car(up to 9'0"wide) WINDCODE®
HDGL,HDGF, 66, 66G, 67, 67G, 68, W6 Garage Door with Optional Impact-Resistant Utes
SP200,SF200, SE200, 6200, 6201,
6203
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16107 R9 II 101526-A-Revl9-signed.Ddf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R9 AE CBPC 130214-A.Ddf
doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No
resistant(large missile impact).
16107.23 23 W6-09 DSIE-1F171: 4400,4401, Double-skin Insulated EPS (exterior skin 27 ga. min.; interior
4300,4301,4310, HDG, HDGL, skin 27 ga. min.) Single-Car(up to 9'0"wide) WINDCODE@
HDGF, 66, 66G, 67, 67G, 68,SP200, W6 Garage Door
SF200, SE200, 6200, 6201, 6203
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16107 R9 II 101526-B-Revl9-sioned.Ddf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other:Doors with standard glazing meet the wind load FL16107 R9 AE CBPC 130214-A.Ddf
requirements of the building code but DO NOT meet the Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.24 24 W6-09 PAN-2F153: 84A, 94, 73, Steel Pan (min. 25 ga.) Single-Car(up to 9'0"wide)
75, 1500, 190,4RST,4RSF,4F,)� WINDCODE®W6 Garage Door with Optional Impact-Resistant
6RST, 6RSF,48,42, 55,48B,42B, Lites
55S,GD5S, GD5SV, GR5S, GR5SV,
AR5S, ARSSV, EDSS, ED55V
Limits of Use I Installation Instructions
Approved for use in HVHZ:Yes FL16107 R9 II 101348-A-Rev17-sianed.Ddf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other:Max. Win,d Speed (V_ult): 170 MPH.Solid doors or FL16107 R9 AE CBPC 130214-A.Ddf
doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No
resistant(large missile impact).
i
https://vuww.floridabuilding.org/pr/pr app dtl.i spx?param=wGEVXQwtDgvyf4ngAXh109aYpgetu2%2f5piPUHU22RIytcEPY2EAeA%3d%3d 215
I
i
2/7/2017 Florida Building Code Online
16107.25 1 25 W6-09 PAN-21`153: 84A, 94, 73, Steel Pan (min. 5 gj.) Sir'gike Car(up(to 9.'01. i i„')
75, 1500, 190,4RST,4RSF,4F, WINDCODEO W6 Garage Door
6RST, 6RSF,48,42, 55,48B,42B,
55S,GD5S,GD5SV, GR5S,GR5SV,
AR5S,AR5SV, EDSS, EDSSV
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16107 R9 II 101348-B-Rev 17-sioned.odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure.- +38 PSF/-44 PSF Evaluation Reports
Other:Doors with standard glazing meet the wind load FL16107 R9 AE CBPC 130214-A.odf
requirements of the building code but DO NOT meet the Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.26 26 W6-09 PAN-21`156: 76, 76V, 2RST Steel Pan (min. 25 ga.) Single-Car(up to 9'0"wide)
i
WINDCODEO W6 Garage Door
Limits of Use i Installation Instructions
Approved for use in HVHZ:Yes FL16107 R9 II 101348-A-Rev17-sioned.odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other:Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R9 AE CBPC 130214-A.odf
doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No
resistant(large missile impact).
16107.27 27 W6-09 PAN-2F156: 76, 76V, 2RST Steel Pan (min. 25 ga.) Single-Car(up to 9'0"wide)
WINDCODEO W6 Garage Door
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16107 R9 II 101348-B-Rev17-sianed.odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other: Doors with standard glazing meet the wind load FL16107 R9 AE CBPC 130214-A.odf
requirements of the building code but DO NOT meet the Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.28 28 W6-09 DSIE-1A171: 2050,2051, Double-skin Insulated EPS(exterior skin 27 ga. min.; interior
2053,4050,4051,4053, 62, 64, 65, skin 29 ga. min.) Single-Car(up to 9'0"wide) WINDCODEO
62G, 621-G, 64G,SDP38, SFL38, W6 Garage Door
SRP38, 134, 135, 136, 6130, 6131,
6133
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16107 R9 II 104814-A-ReV00-sioned.odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +36 PSF/-44 PSF Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH.Solid doors are FL16107 R9 AE CBPC 130423-A.odf
impact-resistant(large missile impact). Created by Independent Third Party: No
16107.29 29 W6-09 DSIE-1A171: 2050, 2051,. Double-skin Insulated EPS(exterior skin 27 ga. min.; interior
2053,4050,4051,4053, 62, 64, 65, skin 29 ga. min.) Single-Car(up to 9'0"wide)WINDCODEO
62G, 62LG, 64G,SDP38, SFL38, W6 Garage Door
SRP38, 134, 135, 136, 6130, 6131,
6133
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16107 R9 II 104814-B-Rev00-sianed.odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +36 PSF/-44 PSF Evaluation Reports
Other:Doors with standard glazing meet the wind load FL16107 R9 AE CBPC 130423-A.odf
requirements of the building code but DO NOT meet the Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.30 30 W6-09 DSIE-1F471: GD2SP, Double-skin Insulated EPS (exterior skin 27 ga. min.; interior
GR2SP, GD2LP, GR2LP,AR2SP, skin 27 ga. min.) Single-Car(up to 9'0"wide) WINDCODEO
AR2LP, ED2SP, ED2LP,4302, HDGC, W6 Garage Door with Optional Impact-Resistant Utes
6202, MFC68,4305, HDGR, 6205,
SFR68, MFR68
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16107 R9 II 103954-A-Rev05-sianed.odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other:Max. Wind Speed (V_ult): 170 MPH.Solid doors or FL16107 R9 AE CBPC 130423-A.odf
doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No
resistant(large missile impact).
i
16107.31 131 W6-09 DSIE-1F471: GD2SP, Double-skin Insulated EPS (exterior skin 27 ga. min.; interior
https://www.floridabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgvyf4ngAXhl09aYpgetu2%2f5piPViHU22RIytcEPY2EAeA/.3d%3d 3/5
i
2/7/2017 Florida Building Code Online
GR2SP, GD2LP, GR2LP AR2SP, skin 27 ga. min.) Single-Car up o 9'Q"ride)�WINDC OE
AR2LP, ED2SP, ED2LP,4302, HDGC, W6 Garage Door # +� �Wy h
6202,MFC68,4305, HDGR, 6205, , ' i-
SFR68, MFR68
Limits of Use Installation Instructions Y 4<< w• /�
Approved for use in HVHZ: No FL16107 R9 II 103954-B-RevO5-sianed.odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other: Doors with standard glazing meet the wind load FL16107 R9 AE CBPC 130423-A.odf
requirements of the building code but DO NOT meet the Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.32 32 W6-09 PAN-217443: G4S, GS4, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Single-
GD4S, GR4S, G4SV, GS4V, GD4SV, Car(up to 9'0"wide) WINDCODE@ W6 Garage Door with
GR4SV, E4S, ED4S, E4SV, ED4SV, Optional Impact-Resistant Lites
SS4,AR4S,SS4V,AR4SV
�I
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16107 R9 II 103488-A-Rev07-sianed.0df
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R9 AE CBPC 130423-A.Ddf
doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No
resistant(large missile impact).
j 16107.33 33 W6-09 PAN-2F443: G4S, GS4, Double-skin Insulated EPS (exterior skin 27 ga. min.; interior
GD4S,GR4S, G4SV, GS4V, GD4SV, skin 27 ga. min.) Single-Car(up to 9'0"wide) WINDCODE®
GR4SV, E4S, ED4S, E4SV, ED4SV, W6 Garage Door
SS4,AR4S, SS4V,AR4SV
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16107 R9 II 103488-B-Rev07-sianed.0df
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other: Doors with standard glazing meet the wind load FL16107 R9 AE CBPC 130423-A.odf
requirements of the building code but DO NOT meet the Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
I
16107.34 34 W6-09 PAN-2F446: G4L, GL4, Gallery/Artistry/Expressions: Steel Pan (min.24 ga.)Single-
GD4L, GR4L,G4LV,GL4V, GD4LV, Car(up to 9'0"wide) WINDCODE@ W6 Garage Door with
GR4LV, E4L, ED4L, E4LV, ED4LV, SL4, Optional Impact-Resistant Lites
AR4L,SL4V,AR4LV
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16107 R9 II 103488-A-Rev07-sianed.odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R9 AE CBPC 130423-A.odf
j doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No
resistant(large missile impact).
j 16107.35 35 W6-09 PAN-21`446: G4L, GL4, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Single-
GD4L, GR4L, G4LV,GL4V, GD4LV, Car(up to 9'0"wide) WINDCODE@ W6 Garage Door
GR4LV, E4L, ED4L, E4LV, ED4LV,SL4,
AR4L,SL4V,AR4LV
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16107 R9 II 103488-B-Rev07-sianed.Ddf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other: Doors with standard glazing meet the wind load FL16107 R9 AE CBPC 130423FL16107 R9 AE CBPC 130423-Aodf
requirements of the building code but DO NOT meet the Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.36 36 W6-16 PAN-217443: GD4S, GR4S, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Double-
ED4S, AR4S Car(9'2"to 16'2"wide) WINDCODE® W6 Garage Door with
Optional Impact-Resistant Lites
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16107 R9 II 104790-A-RevO6odf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +38 PSF/-42 PSF Evaluation Reports
Other:Max. Wind Speed (V_ult): 170 MPH.Solid doors or FL16107 R9 AE CBPC 130423-Aodf
doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No
resistant(large missile impact).
i
16107.37 37 W6-16 PAN-2F443: GD4S,GR4S, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Double-
https://www.floridablrilding.org/pr/pr app dfl.aspx?param=wGEVXQwtDgvyf4ngAXhlOgaYpgetu2%2f5piPViHU22RIytcEPY2EAeA%3d%3d 4/5
I
2l7/2017 Florida Building Code Online
ED4S,AR45 Car(97'to 162"wlde ; I DCODE@ W.6�Garaqe-Do f
W : .1 :IC.:. .,1� h� 4.'o-J\ 1
Limits of Use Installation Instructiong a
Approved for use in HVHZ:No FL16107 R9 II 104790-B�R�v06iDtlf (
Approved for use outside HVHZ:Yes Verified By: Scott Hgtnilton�FL PE 632 6•it i
Impact Resistant: No Created by Independent Tihird:Paty:
Design Pressure:1+38 PSF/-42 PSF Evaluation Reports
Other: Doors with'standard glazing meet the wind load FL16107 R9 AE CBPC 130423-A.Ddf
requirements of the building code but DO NOT meet the Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
i
16107.38 38 W6-16 PAN-217446: GD4L, GR4L, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Double-
ED4L,AR4L Car(97'to 162"wide)WINDCODE@ W6 Garage Door with
Optional Impact-Resistant Utes
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16107 R9 II 104790-A-Rev06.Ddf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +38 PSF/-42 PSF Evaluation Reports
Other: Max. Wind,Speed (V_ult): 170 MPH.Solid doors or FL16107 R9 AE CBPC 130423-A.Ddf
doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No
resistant(large missile impact).
16107.39 39 W6-16 PAN-2F446: GD4L, GR4L, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Double-
ED 4L,AR4LL Car(9'2"to 167'wide) WINDCODEO W6 Garage Door
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16107 R9 II 104790-B-Rev06.Ddf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +38 PSF/-42 PSF Evaluation Reports
Other: Doors with standard glazing meet the wind load FL16107 R9 AE CBPC 130423-A.Ddf
requirements of the building code but DO NOT meet the Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.40 40 W8-09 DSIE-117471: GD2SP, Double-skin Insulated EPS (exterior skin 27 ga. min.; interior
j GR2SP,GD21_13, GR2LP,AR2SP, skin 27 ga. min.) Single-Car(up to 9'0"wide) WINDCODE@
AR2LP, ED2SP, ED21_13,4302, HDGC, W8 Garage Door with Optional Impact-Resistant Utes
6202, MFC68,4305, HDGR, 6205,
SFR68, MFR68
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16107 R9 II 104119-Rev04-sianed.Ddf
Approved for use outside HVHZ:Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure: +54 PSF/-60 PSF Evaluation Reports'
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R9 AE CBPC 130423-A.odf
doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No
resistant(large missile impact).
Go to Page Page 2/3
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
i
low-
0
Credit Card
! Safe
I
I
i
I
https:/Avww.floridabuilcing.orgtpr/pr app dtl.aspx?param=wGEVXQwtDgvyf4ngAXh109aYpgetu2%2f5piPVHU22R[ytcEPY2EAeA%3d%3d 5/5
I
I
�" 4 3 111ir 2 1
'CLASSIC'RAISED PANEL EMBOSS DOORS 'CARRIAGE HOUSE'RAISED PANEL EMBOSS DOORS SHEET, REVISIONS
�. l-_'p'UODELS 24 GA 25 GA 25 GA MODELS 25 GA 25 GA 1 OF 4 REV. NO. ZONE: DATE: ECN NO. APPVO: DESCRIPTION
�tri?a.F,y ., CLOPAY 04A,94 73. 75 76 CLOPAY - -
;,,IDEAL 4RST,4F- 6RST 2RST GDSS,GRSS
¢,. 'GALLERY' 17 2 11 13 SH REVISED FOR NEW LOADS.
k}IDLMES 48.48B 42,42H HOLMES AR5S
'ARTISTRY' --
"' SHORT PANEL ILONG PANEL IDEAL
MODEL 4F IS FLUSH 'CARRIAGE HOUSE' ED5S
SHORT PANEL LONG PANEL D
SHORT PANEL/FLUSH MODELS: (1) INTERMEDIATE STILE BETWEEN EACH
EMBOSS [(3) STILES PER SECTION AT 9'0"WIDE]. EACH INTERM. STILE
OPTIONAL GLAZING MAY BE ATTACHED WITH TOG-L-LOC (TOP & BOTTOM) AND URETHANE ADHESIVE
STANDARD OR IMPACT RESISTANT (ALONG CENTER).
GLAZING. SEE SECTION 8-B ON LONG PANEL MODELS: (3) TOTAL STILES PER SECTION. (1) STANDARD
SHEET 2 FOR DETAllS. INTERMEDIATE STILE BETWEEN EACH EMBOSS. EACH STANDARD INTERM.
' MAX. STANDARD SIZE IS STILE ATTACHED WITH TOG-L-LOC (TOP & BOTTOM) AND URETHANE
79-1/2"x16 IMPACT RESISTANT ADHESVE (ALONG CENTER). EXTRA INTERM. STILES (1) PER LONG PANEL
DOOR HEIGHT t♦ U OF U-BARS GLAZING IS 21-5/8"x14-1/6`. PER SECTION, FIELD-INSTALLED WITH (4) �8 SMS (PER STILE).
SECTIONS MAX OLO SIZE IS 18-1/2`xll",
� UP TO 7'0' 4 6 A END STILES ATTACHED TO DOOR
7'3' TO 8'9' 5 8 - SKIN 'MTH PATENTED TOG-L-LOC
9'0' T❑ 10'6' 6 9 - SYSTEM (TOP, BOTTOM, & CENTER).
]0'9' Tp 12'3' 7 11 a y fs f ,y _A
l2'6' TO 14'0' 8 l2 SEE END HINGE
N C 14'3' TO IS'9' 9 14 e
16' NEW B.
0' 10 15
0
MAX SECTION HEIGHTS 21' 0
0
SEE INTERMED. HINGE
eo VIEW C. SLIDE BOLT LOCK
'- ENGAGES INTO
v STIDLE. VERTICAL TRACK.
ONE LOCK ON
_cc EACH SIDE OF
17)
0 DOOR.
THIS DOOR MEETS OR EXCEEDS THE DESIGN LOADS FOR THE
ULTIUATE WIND SPEEDS LISTED BELOW ACCORDING TO THE FLORIDA =r—
BUILDING CODE OR THE INTERNATIONAL BUILDING CODE(BASED ON 0 TWO POINT LOCKING INSIDE SLIDE BOLT
ASCE7-10)FOR THE FOLLOWING CONDITIONS: 1)ENCLOSED 0m INTO TRACK
BUILDING,2) DOOR HAS 2'OF WIDTH IN BUILDING'S END ZONE.3) 51 SNAP LATCH ENGAGES IOCK OPTION, ENO
ANY ROOF SLOPE,AND 4)TESTING IN ACCORDANCE WITH �. ONTO VERTICAL TRACK. STILE.
ANSI/DASMA 108. SITE-SPECIFIC CALCULATIONS BY A Ol1AUFIED ONE SNAP LATCH ON
B
DESIGN PROFESSIONAL MAY DIFFER. EACH SIDE LA DOOR,?
SPEED(MPH)ULTIMATE WIND
ISS l60 170 ISO 195 IL --- --
OUTSIDE
EXPOSURE HANDLE. LOCK BAR
B,C,ITB,C. D B.C B.C IT OPTIONALOUTSIDE CATEGORY OPTIONAL OUTSIDE KEYED LOCATION OF I ENGAGES IN
LOCK POSITION MAX. DOOR WIDTH =POSITION '-0"ION OPTIONAL VENT -{fl KEYED END TRACK ON
MEAN ROOF HEIGHT 25, 15, 25, 15' 30• HANDLE. STILE. EACH SIDE f INSIDE ELEVATION INSIDE HANDLE OF DOOR.
'CLASSIC' SHORT RAISED-PANEL SHOWN. LONG'CLASSIC' OUTSIDE KEYED LOCK WITH OUTSIDE KEYED LOCK WITH
AND SHORT 'CARRIAGE HOUSE'ARE ALSO APPROVED. SNAP LATCH LOCK OPTION. LOCK BAR LOCKING.
ri.��OEAfS�.%,y is
*..% NO �✓:.*= M 14x5/8" SHEET MANUFACTURING PRODUCT CODE
METAL SCREWSSHORT PANEL• PAN-21`153
LONG PANEL: PAN-21`156
DESI�f�6- TESTN LOADS:LOADS: +57A P.S.F. &&66.0 P.S.F.P.S.F.
PART NO.: N/A
A '9 STATE OF .�� 1/4"x3/4" SELF A
A' •�/ TAPPING SCREWS UNea SloteO Oinxsve =■�f� P y 161nwn�OH 450W40 USA 1,,/v1NDLDan RATING
O R l Q q�j��Q� 00 O TOLERANCES SO31e �P�/'OComay Tel.No.
No.5.3-770-46503 W D P 3 8
NA"I�`,, O .DOD = 2.005 DESCRIPTION: CLASSIC AND CH RP STEEL PAN SC +38/-44 PSF
_ 14 GA, END HINGES 18 GA. INTERMEDIATE HINGE DRAWN BY: MW DATE: 3/15/95 SCALE: NTS
DESIGN ENGINEER: - NEW „� VIEW " ' DegOees = 31/2 - DWG.
SCOTT HAMILTON, P.E. CHECKED BY: - .DATE: -- SHEET 1 OF 4 SIZE
VI IeN Stoll
Otner..ise
FLORIDA LICENSE N0. 63286 DIMEHSONS ARE IN INOHTS.DWG. NO.: 101348 - A/B VER: IBC
4 3 2 FLORMA p ODMCCT AtA PPROVAL 16107
4 3 2 1
w41J1 SIL'RAISED PANEL EMBOSS DOORS 'CARRIAGE HOUSE'RAISED PANEL EMBOSS DOORS SKEET+ REVISIONS
2(0pI:LS 24 GA 25 GA 25 GA MODELS 25 GA 25 GA 2 OF 4 REV. NO.1 ZONE: DATE: ECN NO. APPVD: DESCRIPTION
CLOPA 841,94 73,75 76 CLOPAY
_Lf pL 4RST,4Fr bRST 2RST 'GALLERY' GDSS,GRSS -- 17 - - - - SEE REVISION HISTORY ON SHEET ONE.
x••T HTTCNE6 48, 48B 42,428 -- HOLMES AR5S --
,-,) SHORT PANEL ILUNG PANEL 'ARTISTRY'
IDEAL
. -MODEL 4F IS PLUSH 'CARRIAGE MOUSE' EDSS --
r10 SHORT PANEL LONG PANEL D
art
%`�� IMPACT-RESISTANT CONSTRUCTION: STANDARD ASSEMBLY CONSTRUCTION:
----•- "d SOLID DOORS(NO GLAZING) OR DOORS WITH OPTIONAL IMPACT-RESISTANT GLAZING ARE OPTIONAL DSB OR 1/8-ACYRLIG LITES AVAILABLE- OPTIONAL ACRYLIC GLAZING IS
IMPACT-RESISTANT. OPTIONAL INJECTION-MOLDED POLYCARBONATE FRONT FRAME AND PLASKOLITE OPTIX OR LUCITE CP APPROVED CC2 PLASTIC IN ACCORDANCE WITH IBC/FBC
GLAZING IS GE LEXAN SLX2432T, AN APPROVED CC2 PLASTIC IN ACCORDANCE WITH 2606.
IBC/F8C 2606 AND AN APPROVED Cl PLASTIC IN ACCORDANCE WITH FBC 2612. THE ENTIRE DOOR ASSEMBLY INSTALLED IN COMPLIANCE WITH THIS SECTION MEETS THE
THE ENTIRE DOOR ASSEMBLY INSTALLED IN COMPLIANCE WITH THIS SECTION MEETS THE WIND LOAD REQUIREMENTS OF THE FLORIDA BUILDING CODE OR INTERNATIONAL BUILDING
WIND LOAD REQUIREMENTS OF THE FLORIDA BUILDING CODE AND INTERNATIONAL BUILDING CODE BUT DOES NOT MEET THE IMPACT RESISTANT REQUIREMENT FOR WINDBORNE DEBRIS
CODE AND IS LARGE- AND SMALL-MISSILE IMPACT RESISTANT. REGIONS (REF. CHAPTER 16 FBC/IBC).
SECTION B—B (IMPACT—RESISTANT GLAZING OPTION) SECTION B—B (NON—IMPACT RESISTANT GLAZING OPTION)
C DETAIL 'D' C
FRONT FRAME WITH U.V. COATING ON OUTSIDE SURFACE.
NOTE THAT FRONT FRAME IS NARROWER THAN
D TAI IMPACT-RESISTANT FRAME.
Las
OPTIONAL DECORAIIVE 225 MULTIPURPOSE HIGH BOND TAPE
SMAP—IN INSERT. (BETWEEN FRAME AND FACADE).
DECORATIVE FRONT FACADE. i)
CLAM NG
'(� MOLDED INSIDE
e.IesJ STRUCTURAL SILICONE SEALANT LITE RETAINER.
(BETWEEN STEEL SKIN AND FRAME). (10 SC" PAN HEAD CREW
10 SCREWS PER LITE).
IMPACT RESISTANT
ONE-PIECE INJECTION POLYSTYRENE RETAINER FASTENED TO FRAME WITH
B MOLDE 2G FRLrXAN ONT (10) #8 a 3/4"PAN HEAD MACHINE SCREWS. pp
FRAME 4,GLAZING. U
IMPACT—RESISTANT ASSEMBLY DETAILS STANDARD ASSEMBLY DETAILS
!`\ DRAWING 10134E-A DRAWING 101348-B
- --- , �1 HAM/���ii - - - -- - - - '- - - ---- - --- - ----- ------- -- ----- - - -- ----- - --- ---- ---- --- - ----
�`%poPTO i
\GEIVg -.•2'
NO B3 MANUFACTURING,PRODUCT CODE
*;• / :* SHORT'PANEL: PAN-2F153
��1 DESIGN LOADS: +38.0 P.S.F. & -44.0 P.S.F. LONG PANEL• PAN-2F156
"O T ;7LI,/5�'� TEST LOADS: +57.0 P.S.F. & -66.0 P.S.F. PART NO.: N/A A
A :� STATE F .LUG Udess Stotea Otnery za Clopay 8585 Duke Boutevord WINDLUAD RATING ~
:�T `Zw` TOLERANCES ara .....OH 4 040 USA 1 /I/
.0- t.031 B.MN P aM:ts CmV g Fac N.52-770-4853 V 1 V D P 3 8
to r�NA '�, .00= s.015 DESCRIPTION: CLASSIC AND CH RP STEEL PAN SC +38/-44 PSF
DESIGN ENGINEER: De .005
gr� t�z DRAWN BY: MIN - DATE:3/15/95 SCALE: NTS DWG.R
SCOTT HAMILTON, P.E. UN"
srntm Otnuwse CHECKED BY: - DATE: -- .SHEET 2 OF a SIZE LJ
FLORIDA LICENSE No- 63286 DIMENSIONS ME iN wCMEs.DWG. NO.: 101348 - A/B VER: IBC
4 3 2 U LORMA FRAODUCT AFFLPHOO d L161077
4 1 3 lir 2 11
'CLASSIC'RAISED PANEL EMBOSS DaORS 'CARRIAGE HOUSE'RAISED PANEL EMBOSS➢OERS SHEET, REVISIONS
MODELS 24 'A 25 GA 25 GA MODELS 25 GA 25 GA 3 OF 4 REV. NO_ ZONE: DATE: ECN NO, APPVD: DESCRIPTION
TZyPA4R! 84A,94 73,75 1 76 CLDPAY GD5S.GR5S
v- IDEAL 4RST, 4Fx 6RS7 2RST 'GALLERY' -- 17 - - - - SEE REVISION HISTORY ON SHEET ONE.
'WMES 48. 48B 42,42H -- HG-14ES ARSS --
^..:.'� �Y SHORT PANEL JLDNG PANEL 'ARTISTRY'
-�...} IDEAL __ 3" TALL U-BAR
v x -MODEL 4F IS FLUSH 'CARRIAGE HOUSE' EDSS F-2"THICK 20 GA. GALV. STEEL
Dom! SHORT PANEL LONG PANEL I MIN. YEILD STRENGTH: 50 KSI p
-� 3" �-
'-7/8-
` VERTICAL JAMB ATTACHMENT !WOOD FRAME BUILDINGS): -T-
_ 3/8"x3" LAG SCREWS ON 24- CENTERS. 1-1/8" O.D. WASHER REQUIRED. LAG SCREWS MAY
"� �: BE COUNTERSUNK (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTING SURFACE.
HORIZONTAL JAMBS DO NOT TRANSFER LOAD.
S' 12 GA, GALV. STEEL TOP
VERTICAL JAMB ATTACHMENT (C-90 BLOCK OR 2.000 P51 MIN- CONCRETE COLUMN) ROLLER BRACKET. EACH:
3/8"x3" SLEEVE ANCHOR BOLTS ON 22" CENTERS (2,000 PSI MIN. CONCRETE). WASHERS BRACKET ATTACHED
ff 14x5/B" SHEET METAL
- INCLUDED WITH SLEEVE ANCHORS. SCREWS.
OR
1/4"x3" TAPCON SCREWS ON 19" CENTERS (2,000 PSI MIN. CONCRETE) OR 10" CENTERS 25 GA. MIN. G-40 GALV. SHIP LAP JOINTS.
(C-90 BLOCK). 1" O.D. WASHERS REQUIRED WITH TAPCONS. STEEL SKIN WITH A
ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTING BAKED-ON PRIMER AND
SURFACE. HORIZONTAL JAMBS DO NOT TRANSFER LOAD. A BAKED-ON POLYESTER
C TOP COAT APPLIED TO 14 GA. GALV. STEEL END HINGE C
OTHER JAMB CONFIGURATIONS: REFER TO DASMA TDS-161. A LICENSED DESIGN BOTH SIDES OF STEEL FASTENED TO END STILES W/(4) EACH
PROFESSIONAL MAY ALSO BE EMPLOYED TO APPROVE ALTERNATE FASTENERS AND/OR JAMB SKIN. #14x5/8" SHEET METAL SCREWS & (4)
CONFIGURATIONS. 1/4" SELF TAPPING SCREWS.
0
PREPARATION OF JAMBS BY OTHERS
NOTE: THE DESIGN OF THE SUPPORTING STRUCTURAL ELEMENTS SHALL BE THE
RESPONSIBILITY OF THE PROFESSIONAL OF RECORD FOR THE BUILDING OR STRUCTURE AND 3" TALL x 20 GA. GALV. STEEL U-BARS
IN ACCORDANCE WITH CURRENT BUILDING CODES FOR THE LOADS LISTED ON THIS DRAWING. IN A 2-1-2-1 PATTERN (I.E. TWO
U-BARS ON BOTTOM SECTION, ONE
U-BAR ON NEXT SECTION, ETC.). EACH
U-BAR ATTACHED WITH (2) 1/4"x3/4"
SELF TAPPING SCREWS PER STILE
LOCATION.
B B
-�-.1 13 GA. GALV. STEEL BOTTOM BRACKET.
I ATTACHED WITH (2) g144/8" SHEET METAL SCREWS
ALUMINUM EXTRUSION
&VINYL WEATHERSTRIP.
11111 - _ _- - --_--
<<�TS HAly��ll��i - - - -- - SECTION A A (SIDE VIEW - —_
SFT0` MANUFACTURING PRODUCT CODE
*:: N 6 * SHORT PANEL• PAN-2F1S3
LONG PANEL: PAN-217156
DESIGN LOADS: +38.0 P.S.F. & -44.0 P.S.F. PART NO.: N A
V '!2.1 �ti TEST LOADS: +57.0 P.S.F. & -66.0 P.S.F. /
A '9'. STA E OF :�/� UNeis Stated OMe.,'ze Clopay 8585 Duke Boufemd VINWOAD RATING „
TOLERANCES are _ Te Ro.5134 4504 SA �e
ii�Fss•........ ����� -0 t.031 0.364 RvduUs C4mpom/ Fax No.513-770-4853 YY 6 D P 3 8
o,��OryAL1E�p` _00 3.0005 DESCRIPTION: CLASSIC AND CH RP STEEL PAN SC+38/-44 PSF
DESIGN ENGINEER: Degrees 0000 m t.00 DRAWN BY: MW DATE: 3/15/95 SCALE: NIS DWG.R
I/TCHECKED BY: -- 1J
DATE: - SHEET 3 OF 4 SIZE
SCOTT HAMILTON. P.E. Ualm Staled,Othl-ila
FLORIDA LICENSE No. 63286 DWENSIONS ARE IN WCHEs, DWG. NO.: 101348 - A/B VER: IBC
4 3 2 FLOO QM./k p OO DMC T A.WFIROMQL 161077
4 --
4 3 2 1
'CLASSIC'RAISED PANEL EMBOSS DOORS 'CARRIAGE HOUSE'RAISED PANEL EMBOSS DOORS SHEET. REVISIONS
MODELS 24 GA 25 GA I 25 GA MODELS 25 GA 25 GA 4 OF 4 REV. NO. ZONE: DATE: ECN N0. APPVD: DESCRIPTION
CLOPAY 84A, 94 73. 7S 76 CLOPAY
IDEAL 4RST, 4r. 6RST 2RST 'GALLERY' GDSS, GR5S 17 SEE REVISION HISTORY ON SHEET ONE.
-- MOLMES 48,486 42,42B -- HOLMES ARSS --
' ;. SHORT PANEL LONG PANEL 'ARTISTRY'
x - MODEL 4F IS FLUSH 'CARRIAGE HOUSE' ED5S --
" SHORT PANEL LONG PANEL D
f R 2- TRACK CONFIGURATION. DOOR COUNTERBALANCE SYSTEM JAMB CONFIGURATION.
�j - - HORIZONTAL TRACK
13 GA GALV.STEEL FLAG BRACKET ATTACHED TO DOOR SUPPORT BY DOOR
F{ - JAMB WITH(3)5/16"X 1-5/8"LAG SCREWS HEIGHT `L` INSTALLER(TO SUIT).
19 -J AND TO TRACK WITH(2) 1/4"RVETS. 6'-6" 7 "
-�--z r 7'-0" 7 _2x6 SYP W000 JAMB.SEE OPTIONAL STOP MOULDING BY INSTALLER(TO AIR).
NO7E:TRACK CONflCURAIION 7'-6- JAMB PREPARATION NOTE'.
C ABOVE THE DOOR OPENING DOES 0 AS ROD:SPACING NTE 30'O.C. rP�r'ST 1 xiay 16 GA GALV.STEEL END STILE.
i,jNOT AFFECT THE WIND LOAD x 8-0
'RATING OF THIS DOOR. 8-6` "
- g 62't4" 2"GALV. STEEL TRACK '-0'100" 2-1/2'X 12 GA GALV-STEEL
TRACK THICKNESS: 0.68Y.
u 10'-0`11 " TRACK BRACKETS FASTENED TO hh
-1 O.-G
0'-6" 1 " WOOD JAMBS WITH 5/6`X 1-5/8- —7/16`I.D. ROUND 18 G0. GALV. STEEL CENTER HINGE
csi 17'-0' 4" LAG SCREWS. PUSH NUT FASTENED TO INFER STILES W/(4)EACH
i �• 11'-6"1 ` FASTENER (114x5/8"SHEET METAL SCREWS.
T 36"t2" TYP. 2-1/2-X 12 CA GALV. 12'-0-136`
C z STEEL TRACK BRACKETS, 12'-6"14 ' 14 GA.GALV-STEEL ROLLER HINGES FASTENED TO END STILES W/(4)EACH#14x5/8" C
ATTACHED TO JAMB WITH (1) 3--0"1 SHEET METAL SCREWS AND(2) 1/4-SELF TAPPING SCREWS PER END HINGE.
p 5/16'X 1-5/8 LAG SCREW PER 2"GALV.STEEL TRACK FASTENED TO
TRACK BRACKET. 14'-0" 12 GA GALV STEEL TRACK BRACKETS
WITH EITHER(2) 1/4-DIA.RIVETS OR 2"DVL.7-1/2-LONG STEM, 10 BALL STEEL ROLLER WITH STEEL OR NYLON TIRE.
(1) 1/4"X 5/8"BOLT h NUT PER
1 1 TRACK BRACKET. SECTION C-C
. .. .. 1 '-0"184" PREPARATION OF JAMBS BY OTHERS
LHR BRACKET(2-1/2"x 5-3/4'x 12GA)
ATTACHED WITH(2) 1/4"x 3/4"SELF TAPPING
SCREWS
3` TRACK IS ALSO AVAILABLE,
DOUBLE TRACK
LOW HFA-GROOM OPTION
OUBLE HORIZONTAL
TRACK- p
B B
Op4��S HA ,�r,,,, --- -- - - - - — --- -- - - - - - - -
��� NSF'0jjj�
JST�E-3,�;�
- - MANUFACTURING PRODUCT CODE
*:• SHORT PANEL: PAN-2F153
DESIGN LOADS: +38-0 P.S.F. & -44.0 P.S.F. LONG PANEL PAN-2F156
' :¢ TEST LOADS: +57.0 P-S-F. & -66.0 P.S.F. PART NO.: N/A ^A O. .�1` Unless Stated Oma.�x _ 8565 Duke Bwlewrd VINDLOAD RATING „
Tn•,�� P �� TOLERANCES ae _rj'Qpay ULs4A.OH 4504D USA
OR 10.��,`�� -0= t-031 8sd6Aq Products U.;.r Fw No.5 3 7IG--44853 VY 6 D P 3 8
i,,NNA j7�1�4� ..00 Loos DESCRIPTION: CLASSIC AND CH RP STEEL PAN SC +38/-44 PSF
.0000= 1.001 DRAWN BY: MTV DATE: 3/15/95 SCALE: NITS I DWG.
DESIGN ENGINEER: Degrees= i 1/2' CHECKED BY: -- DATE: -- SHEET 4 OF 4 ISIZEB
SCOTT HAMILTON, P.E. Unless Staled Clh—iso
FLORIDA LICENSE No. 63286 DWENSIONS ARE IN WCMEs.DWG. NO.: 101348 - A/B VER: IBC
4 3 2 GAL G 0DQ PRODUCT DUCTI APPROVAL 16107