Loading...
HomeMy WebLinkAboutProduct Approval (4) I I 217/2017 Florida Building Code Online FLORIDA 090AATM SW OF q j . �� �' — BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge Stats&Facts I Publications'I. FBC Staff I BCIS Site Map I Links I •Search.I Florida ^ r : Product Approval 1111111 USER:Public'User L�Jvi Product ADproyal Menu>Product or Application Search>Application List>Application Detail • •FL#SECRETARY FL1956-R12 Application Type Editorial Change Code Version 2 114 Application Status. Approved I ' *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. i Comments Archived Q i Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin, MO 64802 ! (417) 624-6644 Ext2305 kerri_eden@tamko.com I Authorized Signature Kerri Eden kerri_eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417) 624-6644 Ext 2305 kerri—eden@tamko.com Quality Assurance;Representative i Address/Phone/Email 'I Category Roofing Subcategory As halt Shingles Compliance Method Certification Mark or Listing I Certification Agency UL LLC Validated By Robert J. M. Nieminen, PE Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 1 ASTM D7158 2008 Equivalence of Product Standards I Certified By I I Product Approval Method Method 1 Option A https:/lwww.floridabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5dUhEUshlcmF3nE3F2ytsDnaSgA%3d%3d 1/4 I 2f7/2017 1 Florida Building Code Online Date Submitted 09/17/2015 y, E � � r Date Validated 10/06/2015 ;� v Date Pending FBC Approval ' s .w Date Approved 10/09/2015 b Summary of Prodl cts FL# Model,Number Description or Name 1956.1 Elite Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.odf Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.odf HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 09/17/2018 Design Pressure: N/A Installation Instructions Other:Asphalt shingles shall FL1956 R12 II Glass Seal Elite Glass Seal aoo inst.odf be used only on roof slopes of Verified By: Robert Nieminen 59166 2:12 or greater. Nails must be Created by Independent Third Party: No used as the method of Evaluation Reports attachment. Created by Independent Third Party: 1956.2 Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.odf Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.gdf HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 09/17/2018 Design Pressure: N/A Installation Instructions Other:Asphalt shingles shall FL1956 R12 II Glass Seal Elite Glass Seal arm inst.odf be used only on roof slopes of Verified By: Robert Nieminen PE 59166 j 2:12 or greater. Nails must be Created by Independent Third Party: No used as the method of Evaluation Reports attachment. Created by Independent Third Party: i (1950 Heritage CA dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 RI C CAC Tamko Sery Conf FL 1956 2015.odf Approved for use outside IFL1956 R12 C CAC UL certification 10-11-12.gdf HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 09/17/2018 Design Pressure: N/A, Installation Instructions Other:Asphalt shingles shall FL1956 R12 II Heritaae D F ] P aoo inst.odf be used only on roof slopes of FL1956 R12 II Heritage F aoo inst.gdf 2:12 or greater. Nails must be FL1956 R12 II Heritaoe T aoo inst.odf used as the method of Verified By: Robert 1. M. Nieminen FL 59166 attachment. Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.4 Heritage 30 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R1I C CAC Tamko Sery Conf FL 1956 2015.odf Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.odf HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 09/17/2018 Design Pressure: N/A Installation Instructions Other:Asphalt shingles shall FL1956 R12 II heritaae 30 arm inst aoril 10.odf be used only on roof slopes of FL1956 R12 II heritaae 30 aoo inst f aoril 10.gdf 2:12 or greater. Nails must be Verified By: Robert Nieminen PE 59166 used as the method of Created by Independent Third Party: No attachment. Evaluation Reports Created by Independent Third Party: I 1956.5 Heritage 50 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.odf Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.odf HVHZ:Yes I Quality Assurance Contract Expiration Date Impact Resistant: N/A 09/17/2018 Design Pressure: N/A Installation Instructions Other:Asphalt shingles shall FL1956 R12 II heritage 50 aoo inst aoril 10.odf be used only on roof slopes of FL1956 R12 II heritage 50 aoo inst f aoril 10.odf 2:12 or greater. Nails must be Verified By: Robert Nieminen PE 59166 used as the method of Created by Independent Third Party: No attachment. Evaluation Reports Created by Independent Third Party: https://www.floridabLilding.org/pr/pr_app o.IspVparam=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5ulUhEUshlcmF3nE3F2ytsDnaSgA%3d%3d 214 I i 2/7/2017 Florida Building Code Online a 1956.6 Heritage Premium A dimensional asphalt shingle. 1 Limits of Use Certification Agency Certificate k kkL I� ra�tt t�;,•k �p� 4�_. A ' Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 RI C CAC rfamkg 5erw onfR 1956 2015.odf Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.odf HVHZ:Yes I Quality Assurance Contract Expiration Date Impact Resistant: N/A 09/17/2018 Design Pressure: N/A Installation Instructions Other:Asphalt shingles shall FL1956 R12 II Heritage Premium D P aoo inst.odf be used only on roof slopes of FL1956 R12 II Heritage Premium F aoo inst.odf 2:12 or greater. Nails must be FL1956 R12 II Heritage Premium T aoo inst.odf used as the method of Verified By: Robert Nieminen 59166 attachment. Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.7 Heritage Vintage A heavy weight dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.Ddf Approved for use outside FL1956 R12 C CAC UL shingle matrix.odf HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 09/17/2018 Design Pressure: N/A Installation Instructions Other:Asphalt shingles shall FL1956 R12 II Heritage Vintage arm inst.odf be used only on roof slopes of Verified By: Robert J. M. Nieminen PE 59166 2:12 or greater. Nails must be Created by Independent Third Party: No used as the method of Evaluation Reports attachment. Created by Independent Third Party: 1956.8 Heritage Vintage Hip and ridge shingles 12 X 12 Hip and Ridge Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.gdf Approved for use outside FL1956 R12 C CAC UL shingle matrix.odf HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 09/17/2018 Design Pressure:N/A Installation Instructions j Other:Asphalt shingles shall FL1956 R12 II TAMKOR HerltageC7 12 x 12 Hio and Ridge ADolication Instructions odf be used only on roof slopes of Verified By: Robert]. M. Nieminen PE 59166 2:12 or greater. Nails must be Created by Independent Third Party: No used as the method of Evaluation Reports attachment. Created by Independent Third Party: i 1956.9 Heritage A dimensional asphalt shingle. Woodgate Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 odf Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.odf HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 09/17/2018 Design Pressure: N/A Installation Instructions Other:Asphalt shingles shall FL1956 R12 II Heritage Woodgate D aoo inst.odf be used only on roof slopes of FL1956 R12 II Heritage Woodgate F aoo inst.odf 2:12 or greater. Nails must be Verified By: Robert Nieminen 59166 used as the method of Created by Independent Third Party: No attachment. Evaluation Reports Created by Independent Third Party: 1956.10 Heritage XL A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.odf Approved for use outside FL1956 R12 C CAC UL certification 10-11-12.odf HVHZ:Yes I Quality Assurance Contract Expiration Date Impact Resistant: N/A 09/17/2018 Design Pressure: N/A Installation Instructions Other:Asphalt shingles shall FL1956 R12 II heritage xl aoo inst d aoril 10.odf be used only on roof slopes of FL1956 R12 II heritage A am) inst f aoril IO.odf 2:12 or greater. Nails must be Verified By: Robert Nieminen PE 59166 used as the method of Created by Independent Third Party: No attachment. Evaluation Reports Created by Independent Third Party: 1956.11 Hip and Ridge Hip and ridge shingles Shingles Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 odf Approved for us e outside FL1956 R12 C CAC UL certification 10-11-12.odf https://www.floridabuilding.org/pr/pr app O.aspx?param=wGEVXQwtDgs%2fmGFoyTBraQ%2b%2bCX5ulUhEUshlcmF3nE3F2ytsDnaSgA/o %3d 314 y 2r7/2017 Florida Building Code Online HVHZ:Yes Quality Assurance Contract Expiration Da ee k Impact Resistant: N/A 09/17/2018 1 �r Design Pressure: N/A Installation Instructions Other: Hip and Ridge shingles FL1956 R12 II 12.25x12 Hip and Ridae.odflt shall be used only, on roof FL1956 R12 II 12 x 12 Hip Ridge Application Instructions.pdf slopes of 2:12 orb greater. Nails FL1956 R12 II 12-1-4x12 HipRidae Sealant Dab Illustrations.odf must be used as,the method of FL1956 R12 II 12x12 HipRidae Sealant Dab Illustrations.odf attachment. Verified By: Robert Nieminen 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: i i Back Next i Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® ecq Credit Card j Safe I , i I ; i I I I https-/Avm.floridabuilding.org/pr/pr_app dU. px?param=wGEVXQwtDgs%2fmGFoyT6raQ%2b%2bCX5ulUhEUshlcmF3nE3F2ytsDnaSgM/o3d%3d 4/4 i ® Application Instructions for [ 5) p��Fd ERL!HERITAGE®30 TAM_ KO HCRITACC t �~ BUILDING PRODUCTS' LAMINATED ASPHA6T SHINGLES Dallas,TX• Frederick, MD a Joplin, MO • Phillipsburg, KS THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS,INC.ASSUMES'NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE UNDER THE LIMITED WARRANTY.SEE THE LIMITED WARRANTY FOR DETAILS. THIS PRODUCT IS COVEREUI BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER. IN COLD WEATHER(BELOW 40°F);CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE.SHINGLES. IMPORTANT It is not necessary,to remove:the plastic strip from the back of the shingles. I.BOOT DECK &FASTENERS These shinglesare for applicatiph,to roof decks consisting ofplywood WIND CAUTION: Extreme wind velocities can damage these or sheathing boards capable of receiving and retaining fasteners,and shingles after application when proper sealing of the shingles does to inclines of not less than•2 in.per foot.For roofs having_pitches 2 in. not occur.This canespeciallybe a problem if the shingles are applied per foot to less than 4 in.per foot,refer to special instructions titled in cooler-months or in areas on the roof that do not receive direct "Low Slope Application".For roofs having pitches greater than 21 in: sunlight.These conditions may impede the sealing of the adhesive per foot,refer to special instructions titled"Mansard Roof or Steep strips on the shingles.The inability to seal down-may be compounded Slope Roof":Shingles must be applied properly.TAMKO assumes no by prolonged Cold weather conditions and/or blowing dust.In these responsibility for leaks or defects resulting from improper application, situations,hand sealing of the shingles is required.To insure quicker or failure to properly prepare the surface to be roofed over sealing, apply 4 quarter-sized dabs of TAM-PROD SBS Flashing Cement;TAMKO or TAM-PRO®Plastic Roof Cement,or TAMKO NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, Tam-Seal Adhesive,meeting ASTM D 4586,Type 1,on the back of dry and free from warped surfaces.It is recommended that metal the.shingle 1 in.(25mm)and 13 in.(330mm)in from.each side and drip edges be installed at eaves and:rakes. 1 in.(25mm)up from the bottom of the shingle.Press shingle firmly into the adhesive.For maximum wind resistance along rakes,install PLYWOOD: All plywood shall']be exterior grade as defined by any TAMKO starter shingle including sealant or cement shingles to APA -The Engineered Wood Association. Plywood shall be a the underlayment and.each:other in a 4 in.;(102mm)width of TAM' minimum of.3/8 in.thickness and applied in accordance with the PRO@ SBS Flashing Cement,TAMKO or TAM-PROD Plastic Roof recommendations of.APA-The;Engineered Wood`Association.. Cement,orTAMKO Tam-Seal Adhesive.Caution:Apply ONLY a thin SHEATHING BOARDS: Boards shall be well-seasoned.tongue- uniform layer of adhesive less than 1/8 in.(3mm)thick.Excessive and-groove boards and not over 6 in.nominal width:Boardsshall amounts can cause blistering of the shingles and may soften the be a 1 in. nominal minimum thickness.,Boards shall be properly asphalt iri certain ng.Shingles m resulting f the asphalt flowing, dripping.and staining.Shingles must also be fastened according to spaced and nailed. the fastening instructions described below. 2.VENTILATION Correct placement of the fasteners is critical to the performance of the shingle.if the fasteners are not placed as-shown in the diagram Inadequate ventilation of attic spaces can cause accumulation of and described below,this will result in the termination of TAMKO's moisture in winter months and[a build up of,heat in the summer. liabilities underthe Limited Warranty.TAMKO will'not be responsible These conditions can lead to: for damage•to=shingles caused by winds in excess of the applicable 1.Vapor Condensation mph as stated in the Limited Warranty.See:Limited Warranty on the 2.Buckling of shingles due to deck movement. wrapper or tamko.com for details. 3.Rotting of wood-members. FASTENING PATTERNS:Fasteners must be placed 6-1/8 in.from 4.Premature failure of roof. the bottom edge of the shingle,penetrating through the common bond,and located horizontally as follows: To insure adequate ventilation and circulation of air,the ventilation 1)Standard Fastening Pattern.(For use on decks with slopes 2 system must include in and outlets.This may be accomplished with in.per foot to 21 in.per foot.),One fastener 1 in.from each end and i a combination Of ridge and soffit vents or by using gable end vents. one 13=1/2 in.from each end of the shingle for a total of 4 fasteners. FHA minimum property standards require one square foot of net free (See Standard Fastening Pattern illustrated below). ventilation area to each 150 square.feet of space to be vented.This may be reduced to one square foot of ventilation.area per 300 square STANDARD FASTENING PATTERN feet if at least 40%and not more than 50%of venting is provided FASTENERS NAIL ZONE not more than3 feet below the ridge or if a Class l or II vapor barrier COMMON is installed on the warm In winter side of the ceiling in climate zones eoND 6,7,.and 8 as recommended by the 2012 International Residential 6-1/8" IXPOSURE 5 5/8° Code.For more information consult your design professional.If the ventilation openings are screened,the total area should be doubled. 1 12-1/2" 12-3/8" 12-1/2 ►+ 1" IT IS PARTICULARLY IMPORTANT TO PROVIDE ADEQUATE VENTILATION. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14 Visit Our Web Site'at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300�East 43rd Ave., Denver,CO 80216 800-530-8868 1 i i 6 (CONTINUED from page 1) ORMERLY HERITAGE®30 r �Na TAMK0 HERITAGE J � BUILDING PRODUCTS LAMINATED ASPHALT SHINOLES�:�21 Dallas,TX • Frederick,MD • Joplin, MO • Phillipsburg, KS 2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in.for new construction and 1-1/2 in.for greater than 21 in.per foot.),One fastener 1 in,from each end and reroofing thus allowing a minimum deck penetration of 3/4 in.The one fastener 8-1/2 in.from each end and one fastener 16 in.from each end for a total of 6 fasteners per shingle.(See Mansard and Property Driven dven en ovenrty Driven undenivertidven crooked High Wind Fastening Pattern illustrated below.) IH Asphalt i * MANSARD AND HIGH,WIND WARRANTY'FASTENING PATTERN shingles FASTENERS NAIL ZONE EI Decking COMMON BOND j 54!e° FEXPOSURE5-51B" crown of the staple must be parallel to the length of the shingle. The staple crown should be driven-flush with the shingle surface. t" Staples that are crooked,underdriven or overdriven are considered 3)High Wind Warranty Fastening Pattern.(For HighWind Warranty improperly applied. Application:requirements)'One';fastener 1 in:from each end.One CAUTION: ALL FASTENERS MUST BE DRIVEN INTO THE fastener 8-1/2 in.from each end and one fastener 16 in.from each NAIL ZONE COMMON BOND AS SHOWN IN THE FASTENING end for a total of six(6)fasteners per shingle. In addition to this PATTERN DIAGRAMS. shingle fastening pattern requirement for High Wind Application, TAMKO also requires the use of TAMKO starter shingles including 4.ONDERLAYMENT sealant strip at eaves and rakers.Alternatively,along rakes,cement UNDERLAYMENT: An underlayment must be applied over the shingles to the underlayment and each other in a 4 in. (102 mm) entire deck beforethe installation of TAMKO shingles.Failure to add Width of TAM-PRO@ SBS Flashing Cement,TAMKO or TAM-PROD underlayrent can cause premature failure of the shingles which is Plastic Roof Cement,orTAMKO Tam-Seal Adhesive.Caution:Apply not covered by TAMKO's Limited Warranty. ONLY a thin uniform layer of adhesive less than 1/8 in.(3mm)thick. Excessive arriounts can cause, blistering of the shingles and may Products which are acceptable for use as underlayment are: soften the asphalt in certain Underlayments resulting inthe asphalt Asphalt Saturated Felt Underlayments: flowing;dripping and Staining.' • SuperX 30T"t Underlayment High Wind Application is offered on new construction or complete • TAMKO No.15 Asphalt Saturated Organic Felt tear-off applications only.It is not offered for recover applications. • Any TAMKO non-perforated asphalt saturated organic felt If High Wind Application requirements are not followed,the High • A non-perforated asphalt saturated organic felt which meets Wind Application Warranty MPH,as stated on Table I in the Limited ASTM:D226,Type I or II or ASTM D4869' Warranty,reverts to the Standard Application Wind Warranty MPH Specialty Underlayments: limit. (See Mansard and'High;Wind Fastening Pattern illustrated above.) • Tam-Shield® Synthetic Underlayment or Synthetic Shield Underlayrent NAILS:TAMKO recommends the use of nails as the preferred method . TAMKO TW Metal and Tile Underlayment,TW,Underlayment 'i of application. Standard type,roofing nails should be used. Nail and Moisture Guard PIusO (additional ventilation may be shanks should be made of minimum 12 gauge wire,and a minimum required. Contact TAMKO's Technical Services Department head diameter of 3/8 in.Nails should be long enough to penetrate for'more information.) 3/4 in.into the roof deck.Where the deck is less than 3/4 in.thick, A self-adhesive underlayment designed for use with asphalt the nails should be long enough to,penetrate completely through shingles which meets ASTM D1970. plywood decking and extend at least 1/8,in.through the roof deck: Drive nail head flush with the shingle surface. For Asphalt Saturated Felt Underlayments: Apply the felt when the deck is dry.On roof decks with slopes Properly Driven ImpreperlyDdven 4 in.per foot and greater apply the felt parallel to the eaves '=.area mindlameter underddven evmdriven creaked lapping.each course of the felt over the lower course at least Asphalt 2 in.Where ends join,lap the felt 4 in.If left exposed,the felt Shingles El Decking may be adversely affected by moisture and weathering.Laying 1 } of the felt and the shingle application must be done together. '� �t/4•nominal For All Other Specially Underla merits: straight,good penetrmicn, Inadequate too deep,cuts. Inadequate and gush with shingle surface penetreo.n Inteshingle anaherage On roof decks with slopes.4 in. per foot and greater apply the underlayment parallel to the eaves in accordance STAPLES:If staples are used!in the attaching process,follow the with underlayment written application instructions. The above instructions for placement.All staples must be driven with underlayment should not be left exposed for a longer period of pneumatic staplers.The staple must meet the following minimum time than is specified in the underfayments written application dimensional requirements.Staples must be made from a minimum instructions.The final roof covering must be installed-before 16 gauge galvanized wire.Crown width must be at least 15/16 in. the structure is exposed to adverse weather conditions,such (staple crown width is measured outside the legs).Leg length should as wind driven rain,high wind,hail,ice storms,etc. (Continuecn Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09n9n4 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.Gom 1 Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 2 I I I r, ® (CONTINUED from page 2) iy FORMERLY HERITAGE®30 tom; TAMKO HERITAGE BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas,TX • Frederick, MD • Joplin, MO • Phillipsburg, KS 1 In areas where ice builds up along the eaves or a back-up of water of shingle to start the fourth course and use the remaining,10-3/8 from frozen or clogged gutters is a potential problem,TAMKO's in.piece to begin the fifth course.Continue up the rake in as many Moisture Guard Plus®, TW Metal and Tile Underlayment or TW rows as necessary using the same formula as outlined above. Underlayment(or any specialty eaves flashing product) may be The butt of the.shingle should be aligned with the top edge of the applied to eaves,rakes„ridges;valleys,around chimneys,skylights sawtooth of the underlying shingle fora 5-5/8 in. exposure (see or dormers to help prevent water damage. Contact TAMKO's shingle application drawing illustrated on this panel).When you Technical Services Department for more information. make your final cut at the roof's edge,flip any pieces that are 8 in.or Substitute products as shingle;underlayment should not be,used. longer back onto.the roof.These pieces can be Worked in anywhere without creating zippers or color variations. S.APPLICATION INSTRUCTIONS NOTE:Do not align joints of shingle courses when working in cut STARTER COURSE:Astarter course may:consistof TAMKO Shingle pieces.Joints should be no closer than 4 in.from one another.. Starter,TAMKO 10-inch Starter or self-sealing 3-tab shingles.If self- sealing 3-tab shingles are usedi remove the exposed tab portion and install with the factory.applied adhesive adjacent.to the eaves.Attach 'qn your first course shingle to make 29'and a 103/B° length.Cut a second shingle to make a 23'and the starter course with approved fasteners along a line parallel to a1a3f8°length. and i.5 in.to;3�in.above the eaves edge.The starter course should 291 10 ' overhang-both the eaves and rake edges 1/4 in.to 3/8-in.if drip edge flashing is not used along the eaves or rakes.If drip,edge flashing �,. ,6 • is present,install shingles even with the drip edge. - For maunwm wind resistance along rakes.Install any TAMKO'st""shin or including sealant cement shingles shingles _ to undedaymenl and each other.8t a W(102 mm),widlh of - TAM•PROO SBS Flashing Cement,TAMKO or TAM-PROD Plastic R Urtledayrtient Deck oof Cement or TamSeal Adtlesw.e. Eave Bashing or espaB sahaaled fell Drip edge Begin application with a full length shingle. ____ __________________________ G 2.ThmIayyour29°,23°,163M and103r8-lemphs. Rake _ AS you can see,three shingles with two cots make five courses. Fasteners \ brated 1-117 to 3' - from rakeedge r --- ______ Continue working your way across the rmt.When you make your ___ 3.final cut at the roofs edge,/fip arry pieces that are 8°or longer I >;� ♦ back onto the roof.These plants can he worked in anywhere without creating onotsorcolor is ofshi. NOTE:Do not align Joints of shingle courses when working in Start rust cut plecea Joints should be no closer than 4'from one another. ship to l2 shingle em,aa and rs overhI Seif-seating Eeve Fazteners Drip strips ordi togffset%h'futh 1hrtoa9 rakes atlhesive 1-1red firsts i weer to offset with the bashing iin 3is g no present. edst edge along am, 1-12'l0 3° first Shingle course. flashing ihngIs ntlldsp obngeedg iro.....dge edgeges glesmrs-t wrkkeeege 6.�LOW SLOPE APPLICATION Install shingles ev swim ' dsp edge. ' SHINGLE APPLICATION:'Stari the first course with a full size shingle On pitches 2 in.per foot to 4 in.per foot cover the deck with two i layers of underlayment. Begin,by applying the underlayment in a 1 and overhang the rake edge 1%4 in.if drip edge is not present.If drip edge is present,align shingle edge with drip edge flashing:Cut 1/2-sheet width along the eaves and overhanging the drip edge by 1/4 to 3/4 in.Place a full-sheet width over the 1/2-sheet width 1.0-3/8 in.from a full shingle to form a shingle 29 in.long.Use this to start the second course(se,e diagram below).Cut a 23 i.m long starter piece,completely overlapping it.All succeeding courses will shingle to start the third course.Use the remaining 16-3/8 in.piece be positioned'to overlap the preceding course.by 1/2-sheet width. If winter temperatures average 250F or less,thoroughly cement loa/a^ the laps of the entire underlayment to each other with TAM-PRO l or TAMKO Plastic Roof Cement from eaves and rakes to a point reheat 10-3/8^ ° of a least 24 in. inside the interior wall line of the building'.As an repeat 10,18.1 courses '16-3/8" zs: alternative,TAMKO's Moisture Guard Plus®;TW Metal and Tile zs° Underlayment, or TW Underlayment self-adhering underlayment may be used.in lieu of the cemented felts. zs. Fu►t 1s re za^ rake 7.MANSARD ROOF OR STEEP SLOPS'ROOF 1oaJs^ If the slope exceeds 21 im per foot(60),each shingle must be sealed sth course ih course with TAM=PRO® SBS Flashing Cement,TAMKO or TAM-PRO@ za° 1c>alo° Plastic Roof Cement,or TAMKO'Tam-Seal Adhesive immediately 4 163/8" 3rd come r1�,`' _ upon installation.Quarter-sized'dabs of cement or adhesive must be applied.to shingles with a 5-5/8 in.exposure,use 6 fasteners per 2nd course 29' 1INt,�xy m shingle.See.Section 3 for the Mansard Fastening.Pattern. ,,.�." ,.y 29C list course Full ea a!,► (Continued) j Central District 220 West 4th St., Joplin,.MO 64801 800-641-4691 09/19/14 Visit Our Web Site'at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO' 80216 800-530-8868 3 I o (CONTINUED from page 3) F-R I LY HERITAGE®30 TAMKOI HCRITAGE& LAMINATED ASPHALT SHINChES 891160ING PRODUCTS, Dallas,TX e Frederick, MD e Joplin, MO 9 Phillipsburg, KS S.RE-ROOFINO' 9.VALLEY APPLICATION Bdfoirb re-roofing,tie certain to inspectthe roof decks.All plywood shall Overthe shingle underlayment,,center a minimum 36 in.wide sheet of meei the requirements listed in,Section 1. Moisture Guard Plus®,TW Metal&Tile Underlqyment,or a minimum It is not recommended to install laminated asphalt shingles directly 50 lb. roll:roofing in the valley..Nall the underlayment only where over existing laminated shingles due to the unevenness of the existing necessary to hold it in place and then,onl il the outside edges. I - I . -yna multi-layered shingles.The performance of the sealant feature maybe compromised,preventing the shingles from sealing properly.It is IMPORTANT-PRIOR TO INSTALLATION WARM SHINGLES to PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING aGceptable,fo install laminated shingles over existing three-tab:strip SHINGLES TO FORM VALLEY. .shingles whichare flat and essentially intact.Nail down,or remove curled or broken shingles from the existing roof..Replace.all missing shingles After valley flashing is in place: with new ones to provide a smooth base.Shingles that are buckled a Apply1he first course of shingles along the eaves of one of the, usually indicate warped decking or protruding nails.Hammer down all intersecting roof planes and across the,valley. protruding nails or remove them and refasten in a new l'ocation.,Remove all drip edge metal and replace with new. Note:For properfloWrof water over the tdmmed shingle,always If re-roofing over an existing roof where new flashing is required to ,9 q start applying the shingles on the roof plane that has the lower protect-against ice dams(freezetthaw cycle of waterand/orthe backup slope orless height.. of water in-frozen or clogged gutters),remove the old roofing to a point e Extend the end shingle at least 12 in.onto the adjoining roof. at least 24 in.beyondthe interior wall line and apply TAMKQ's Moisture Apply succeeding courses in the same manner,extending them. Guard Plus®,TW Metal and T-iie'Underlaymerlt,or TW Undeflayment, across the valley and onto the adjoining roof. Contact TAMKO's Technical Services Department for more information; Measurements will vary when nesting over an existing 5 im exposure 9 Press the shingles tightly into the valley. single roof:Call TAMKQ Technical Services for further information. 9 Use normal shingle fastening methods. The nesting procedure described below is the preferred method for Note:No fastener should be.within 6 in.of the valley,centerline, reroofing over existing metric size shingles With a 5-5/8 in-exposure. and'two fasteners should be placed at the end of each.shingle See description below: crossing-the valley. Starter Course:Remove the tabs and an additional portion from the To the adjoining roof plane,apply,one row of shingles vertically head of a full size shingle so that its height is:equal to the. exposure of facing the valley and 2 in.back from,the valley centerline. the existing shingles.Position the resulting strip over the existing roof edge(with the factory-applied adhesive strip along the eaves).Cut Note: For a neater Installation; snap a chalkline over the approximately 6 in.from the take end and apply the remaining portion at shingles for guidance. the eaves.Continue the starter stflp,byapplyingfull length shingle strips To complete the valley,apply shingles on the adjoining roof cut to,height as above,evenly al6ng the existing roof at the eaves.The first shingle of each row at existing roof should overhang the eaves far enough to carry water plane by positioning the tip of the I the 2 in.point from the centerline where the edge of the vertical off into the,gutter.If this is not,the case,cut and apply the starter shingle has been applied,covering the vertical shingle. strip so that it will provide sufficient overhang for proper drainage.. Exisft shingles Minimum 36'vvide sheet valley centerline 5 of Molsturb Guard PILLS, I IYv.Metal 8 Extra nail in Tile or 50 lb'or heavier roll roofing endof.shingle Extend end'shngle 12'-78'beyond Ddp edge valley centerline Ddp edge N—hingles Undedayment No,fasteners within 6!of 6enterline 5 518, wlX=8 Fist Course.Remove an amount from the butt edge of a full-size shingle so that the remaining portion of the shingle fits between the butts of-the existing third course.This course;must also be applied evenly along the eaves edge of the new starter strip. Place tip of shingle on the edge of the vertical shingle,2 inches back Second and Succeeding Courses:Remove 10-3/8 in.from,the rake from valley centerline and covering end of the first shingle in the second course, and continue with full. the vertical shingle. width shingles forthe remainderbf the course,placing the top edge of each new shingle against the butt edge of the.old shingle in the course above.This method should creat6 an exposure of.5-5/8 in;afterthe fir CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT st FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE .I I course.When beginning the succeeding courses continue to followthe 800-641-4691. Heritage application instructions!(See section 5). (Continued)l Central District, 220 West 4th St., Joplin,M6 64801 800-641-4691 69/19/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800"368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 .800-228-2656 tamko.com I Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300.East 43rd Ave., Denver,CO 80216 800-530-8868 4 •� fff �j DDD ® (CONTINUED from page 4) FORMERLY HERITAGE®30 TAMKO HERITAGE® BUILDING PRODUCTS LAMINATED ASPHALT SHING6BS Dallas,TX• Frederick, MD • Joplin, MO • Phillipsburg, KS I 10.HIP AND RIDGE FASTENING DETAIL Apply the shingles with a 5-1/8 in.exposure beginning at the bottom of the hip.or from the end of the ridge opposite the direction of the prevailing.winds.Secure each shingle with one fastener on each side, 5-5/8 in.back from the exposed end and 1 in..up from the edge. TAMKO recommends the use of TAMKO Hip & Ridge shingle products.Where matching colors are available,it is acceptable to use TAMKO's Elite Glass-Seal.shingles cut down to 12 in.pieces. Fasteners should be 1/4 in.longer than the one used for shingles IMPORTANT PRIOR TO INSTALLATION, CARE NEEDS TO BE TAKEN TO PREVENT DAMAGE WHICH CANT OCCUR WHILE BENDING,SHINGLE IN COLD WEATHER. Direction prevailing wind Start H5-118"exposure here- 1 5�- �, Fastener Start here 5-1/8"exposure THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE .ROOFING CONDITIONS DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES NO RESPONSIBILITY FOR{LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE I MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE UNDER THE LIMITED WARRANTY. SEE THE LIMITED WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE CONTACT TAMKO'S-TECHNICAL SERVICES DEPARTMENT AT 800-641-4691. Information included in these application instructions was current at time of"printing.To obtain a copy of the most current versionlof these application.instructions,visit us online at tamko.com or call us at 800-641-4691: TAMKO®,Moisture Guard Plus®;Tam-Shield®,TAM-PRO®and Heritage®are registered trademarks and SuperX 30 is a trademark of TAMKO Building Products,Inc. i I i I Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 5 JP69909