Loading...
HomeMy WebLinkAboutProduct Approval (5) I 8119/2015 Florida Building Code Online � Business Professional Regulation flolic�Depme($of BCIS Home I Log In I Ul ser Registration I Hot Topics I Submit Surcharge I Stats&Facts Publications I FBC Staff I BCIS Site Map I Links I •Search Busines Profess' I0a. Product Approval USER:Public User Regulation ! Product Approval Menu>Product or Application Search>Application List>Application Detail OF FL#SECRETARY FL15210-R5 Application Type Revision Code Version 2 114 Application Status , Approved I , Comments 'I Archived Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440)969-9773 Ext 16 rickw@rwbldgconsultants.com I � Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440) 969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance'Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440)969-9773 Ext 16 ronoconnell@plastpro.com Category 'Exterior Doors Subcategory Swinging.Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received i Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report I Florida License PE-43409 Quality Assurance'Entity National Accreditation and Management Institute Quality Assurance,Contract Expiration Date 12/31/2018 Validated By Ryan J. King, P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL15210 R5 COI CERTIFICATE of INDEPENDENCE.Ddf i Referenced Standard and Year(of Standard) Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 1998 ASTM D638 2003 ASTM E1300 2004 ASTM E84 2005 ASTM G26 1995 https:/Avww.floridabtilding.orgfpr/pr app o.i spx?param=wGEVXQwtDgv3yWKJZlQRCFPqu8gbCgpp/`2bzCgAjPwi2OvD2Tk%2fmQBUw`/o3d`/o3d 1/4 I 8/19/2015 ; Florida Building Gode� lirfe �& C� I G 155 F 2005 TAS 201` 2' 203 E 1994 I Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15210 R5 Eauiv Equivalency Of Standards.odf Sections from the Code I I I Product Approval Method Method 1 Option D Date Submitted 04/24/2015 Date Validated j 04/26/2015 Date Pending FBC Approval 04/29/2015 Date Approved 06/23/2015 Summary of Products i FL# Model,Number or Name Description 15210.1 LGra�in mooth/Wood Grain/White Wood 6'8"Impact"Opaque Fiberglass Single Door /Rustic/Mahogany'Series O Inswing/Outswing_(X-Configuration)) J glass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210,1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INSt15210.1 for Design Pressure Ratings, any FL_15210 R5 AE Eval 15210.1.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.2 b. Smooth/Wood Grain/White Wood 68"Impact"Opaque Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing (OX or XO; OXO- Fiberglass Door Configurations) - Limits of Use i Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210.2.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.2 for Design Pressure Ratings, any FL15210 R5 AE Eval 15210.2.odf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 15210.3 c. Smooth/Wood Grain/White Wood 68"Impact"Opaque Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing (XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 j Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15210.3 for Design Pressure Ratings, any FL15210 R5 AE Eval 15210.3.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.4 d. Smooth/Wood Grain/White Wood 68"Impact"Glazed Fiberglass Single Door- j Grain/Rustic/Mahogany Series O Inswing/Outswing (X-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.4 for Design Pressure Ratings, any FL15210 RS AE Eval 15210.4.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. i 15210.5 e.Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing (OX or XO; OXO- Fiberglass Door Configurations) https://vuww.floridabuilding.org/pr/pr app dU.aspx?param=wGEVXQvutDgv3yWKJZ1QRCFPquBgbCgp%2bzCgAjPwi20vD2Tk%2fmQBUw%3d%3d 214 FA M 950 > R � 8/19/2015 Florida Building Code Online . �."k n .::S; i Limits of Use Installation�InsYruotfgj5 ti Approved for use in HVHZ:Yes FL15210 RS II��Inst 15210.5.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.5 for Design Pressure Ratings, any FL15210 R5 AE Eva[ 15210.5.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. j 15210.6 j f. Smooth/Wood Grain/White Wood 6'8"Impact"Glazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites-Inswing/Outswing (XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 j Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.6 for Design Pressure Ratings, any FL15210 R5 AE Eva[ 15210.6.odf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. I 15210.7 g. Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door-Outswing (X- Grain/Rustic/Mahogany Series O Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 RS II Inst 15210.7.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST'15210.7 for Design Pressure Ratings, any FL15210 R5 AE Eval 15210.7.odf additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars. 15210.8 h. Smooth/Wood Grain/White Wood 8'0 "Impact"Glazed Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Outswing(OX or XO; OXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210.8.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INSTI15210.8 for Design Pressure Ratings, any FL15210 RS AE Eval 15210.8.odf additional use limitations,installation instructions and product Created by Independent Third Party: Yes i particulars. 15210.9 [. Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Double Door with or without Grain/Rustic/Mahogany Series O Sidelites-Outswing (XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210.9.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15210.9 for Design Pressure Ratings, any E-15210 R5 AE Eval 15210.9.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15210.10 j. Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door-Outswing(X- Grain/Rustic/Mahogany Series O Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210.10.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes i Design Pressure: N/A Evaluation Reports Other:See INST 15210.10 for Design Pressure Ratings, any FL15210 R5 AE Eva[ 15210.10.odf additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars. 15210.11 k.Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Sidelite or Grain/Rustic/Mahogany Series O Sidelites-Outswing (OX or XO; OXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210.11.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports https:/Avww.floridabdlding.org[pr/pr app d . spx?param=wGEVXQwtDgv3yWKJZIQRCFPquBgbCgp%2bzCgAjPwi2OvD2Tk%2fmQBUw%3d%3d 34 8/19/2015 Florida Building Code Online Other:See INST 15210.11 for Design Pressure Ratings, any FL15210 R5 AE E 0.1<i. additional use limitations,installation instructions and product Created by Indeperiden Thin Party: Y,es 4 particulars. ¢&i 15210.12 I. Smooth/Wood Grain/White Wood 8'0"Impact" Opaque Fiberglass Double Door with or without j Grain/Rustic/Mahogany Series O Sidelites-Outswing (XX; OXXO-Configurations) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210.12.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 1115210.12 for Design Pressure Ratings, any FL15210 R5 AE Eval 15210.12.1)df additional use limitations,installation instructions and product Created by Independent Third Party: Yes particulars. j j 15210.13 m. Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Single Door with Surface Grain/Rustic/Mahogany Series O Bolts-Outswing (X-Configuration) Fiberglass Door Limits of Use Installation Instructions I Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210.13.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INSTI15210.13 for Design Pressure Ratings,any FL15210 R5 AE Eval 15210.13.Ddf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15210.14 n. Smooth/Wood Grain/White Wood 8'0"Impact"Opaque Fiberglass Double Door with Surface Grain/Rustic/Mahogany Series O Bolts on Active Door panel -Outswing (XX-Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210.14.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other: See INST 15210.14 for Design Pressure Ratings, any FL15210 R5 AE Eval 15210.14.Ddf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 15210.15 o. Smooth/Wood Grain/White Wood 8'0"Impact"Glazed Fiberglass Single Door utilizing the Grain/Rustic/Mahogany Series O WINDSERT'" an operational window insert-Outswing (X- Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15210 R5 II Inst 15210.15.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 15210.15 for Design Pressure Ratings, any FL15210 R5 AE Eval 15210.15.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. I Back Next Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacv Statement::Accessibility Statement:: Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-retards request,do not send electronic mail to this entity:Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: .I gg - O i 'I secure I hops:/Avww.floridabuilding.org/pr/pr app dU.aspx?param=wGE\/XQwtDgv3yWKJZ1QRCFPquBgbCgp%2bzCcANPwi2OvD2Tk%-4rnQBUw%3d%3d 4/4 I I p -1 astp ro 37.50'MAX.OVERALL FRAME.WIDTH �. om 5200 W.•CENTURY BLVD. =\1• , Z LOS ANGELES CA .90045 '"....... f ////' y '`` ` N _!2 y illllll \ Z o m o Smooth / Wood.Grainf/,White-.Wood:,Grdih N o z _ .Rustic/Mahogany _ $ � m \' N LO Z O C W• a - - -"—; --m_da� — — �Sed6s 0 Fiberglass:Door -- - - -- --- --- -_Z- - -- -- - - - INSWINGIOUTSWING 3 E 9 z 0o !!IMPACT' o GENERAL NOTES �o ro w N? 1. This product has been evaluated and is in compliance with the 5th Edition'(2014)Florida Building Code 10 (FBC)structural requirements inducing the"High Velocity Hur icane Zone"(HVHZ). ; X 0 z o o z 0 2. Product anchors shag be as rested and spaced as shown on details.Anchor embedment to base material 3 m shall be beyond wall dressing or stucco. > > �y win O p 3. When used in the"HVHT'this product complies with Section 1626 of the Florida Building Code and does not G "g a Cn require amimpact resistant covering. °D 'g a Q 4. When used in areas.outside of the"HVHZ''requiring wind borne debris protection this product compiles with Section 1609.1.2 of the 2014 FBC and does not require an impact resistant covering:This product meets m E missile level"D"and includes Wind Zone 4 as defined in ASTM E:1996 and Section 1609.1:2.2 of ihe:FBC. 5. For 2x stud construction,anchoring of these units shag be the same as.that shown for 2x buck masonry a a construction. N 6. Site conditions that deviate from the details.of this drawing require further engineering analysis by a licensed w _o 2 engineer or registered architect. _ `� 7. Outswing configurations meet water infiltration requirements for"HVHT'. All other configurations do not meef the water infiltration requirements for thei HVHZ'and must be installed only in non-habitable areas or Q J -at habitable locations protected by.on overhang or.canopy such that the angle:between the edge of aZ ` canopy or overhang to sill is less than 45 degrees. '- 8 = MAX: DESIGN PRESSURE(PSF) TABLE OFCONfENTS SWING' FRAME- SHEEN DESCRIPTION DIMENSION POSITIVE. NEGATIVEt, + 'v z 1 Typical elevalon;design pressures,&general notes 37.50" z u 2 Door panel details x +75.0: -75:0 DAB:02/14.12� +� 4 Ye�rticoalcross sectintal cross ons INSWING 82.00" 5 3 point lock details, 37.50" 6 3-point lock details OUTSWING' x +75.0 -75.0 44 a 7 1 Buck and frame anchoring 81.13" muVnNG No• s B 1 components See sheet 2 for hardware design pressure-0mitations FL-1521oif4- o 5 9 Bill of materials A: a OA'---�{�� EXTH110R I 0.4- ��.• � y T13�d r� V— k 10— z°m"z INTERIOR TOP RAILCAP(P ) LATCH STILE LVL (COMP. _ oa ( ( - --- - --- --- -- - - - --HINGE STILE LYL( -- - - - - ----- -CAP-PVC 1 HORIZONTAL CROSS SECTION :. —f E 9 Z 1 H a J 35.75"MAX OA. o WIDTH 6' ,P 0 0 0 o� o � m Z 6g; •. v a m `� o ........ Q 0 O HAR(fWARE1Atl(J a a ;,•,:. "n INTERIOR EXTERIOR x>- rs c MAdNUFACTGRER MQpEL M�►X.P.F31GN o >m E m I I SIGNATURE SERIES _ _.11L_�11 �� DEAD DEAD80Li: SIGNATURE SERIES(960) ±75 FOAM CORE � d (POLYURETHANE- _ g O KNOB: �°SERIES(F51) 1.9 PCF MIN.) DEA a SCNUIGE DBOLT: r *T5- SERIES(B60/62) ° o X z SEE HARDWARE TABLE PAMEX LEVER: F13BSERIES + a... DEADBOLT: F07 SERIES 75 :•°. in � 1 HOPPE MUMPOINTLOCK: 3•POINTTONGUE +50 ; FlBERGLASSSgN o. SEE HARDWARE TABLE .. (0.12YMIN.THK.)�� •�'.' <P W i F MULTI-POINT LOCK: TRILENNIUM-JW SERIES ±75 ) z z' See sheets 5 and 6 for multi-point lack details. s BOTTOM RAIL fe - (COMP) GVE 02116112 p iu DOOR PANEL Ow(;-er: mi 40 ° 2 VERTICAL CROSS SEC17ON CHK.ar:OWING •`-wi+3`L'=C7 s FL-152--10.TMira o N sHEEf 2 OF 9'1, lg i R:Clients\Plastpro,Inc PERMANENT\Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and GlamAC-Drawings\FL-15210(2014)\FL-152101-6dwg,3.1 A so e i I W C I, o C L ^ w I I �y n yO yo a I, mN V Zy t7A A W n z g M k + O 0 E3j8 W W W N I ' I I T I y�' Z m A_ A W W O A I � N O V I �o N X� I �n � H4 O T = (7 N D Los s p 8 � z '° o W N m m 70 M 002 0 O 0C, v �� a N A V A 3 z cq O0 O � I Z m A o W z SC No.43109 z t* $ Q PRODUCT• Doeum.rd.Pnpana ey. Lyndon F. Schmidt �/i •••'• �•••/• IW i o NPLASTPRO INC.FIBERGLASS DOOR I. No. 43409 Ln p ? r -i rn PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. 1 3 9 15 UPDATE TO 5TH ED. 2014 FBC JK ���/P.O. Box 230. Valr(co. FL 33595 ro NO DATE BY HORIZONTAL CROSS SECTIONS DV phone No.: 813.659.9197 _`' ISIONS C FBPE CA No. 9813 ®2G72 R.W.BUILDING CULT 8INC. l ` r 1 I i R-.\Clients\Plastpro,Inc PERMANENAFlorida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glared\C-Dra ings\FL-15210(2014)\FL-152101-61'41 �77 Aw M A OT 01 • ° v -0 mn 0 °p. C O < _ 7T 3 O 3 y G H m n Z a MIto m v 7p A i p N I .p. lV 0.15' MINK co p° m (TYP.) - I rn ca rn EMB.(TYP.J M p,° A A N A I T °p a� 0 O �N a a' g m Z A n 70 r11 I ' m ! �, m 1-1/4"MIN. N g a EMB.PP.) A ° N T I a ° \ C ° c n ° v T 0 N ° • o M T 7O M n m 0 g Z O A O �y I y o° Z 6- (� 00 1-1/4"MIN. Z EMB.PP.J `pttltO O1j q4 V ow /, . Q `��� �:$CNM/O A `�. v,.••;yceiigS••:�' No.43409 F tt•' .'f t I f�Z24r c "s%j PRODUCT: Docum.ld�PreparedBY: F6DM.r C \ `;,� ill;'1�4 >•5�c m I <�y Lyndon F. Sohmldt �i� •'•.!20 �• `4 I I� PLASTPRO INC. P.E. No. 43409 .�4i��01V/11. o Z FIBERGLASS DOOR j �I/111111 PART OR ASSEMBLY: (,� BUILDING CONSULTANTS, INC. lu� p '1 7C U1 1 3 9 15 UPDATE TO 5TH ED. 2014 FBC JK tJL P.O. Box 230, VaIrlo, FL 33595 kl NO DATE BY VERTICAL CROSS SECTIONS phone No.: 813.659.9197 /'� "'1 ISIONS ./"'� FBPE CA No. 9813 ®2012 R.W.BUILOING CONBYLTANTG INC. 1 i i MaientAPlastpro.Inc PERMANENT\Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glared�C-bravrings\FL-15210(2014)\FL-15210.1.6dw9 51 D z C D OVERALL HEIGHT D m HANDLE HEIGHT 0 I e e e e �-�e• z •, e M - l 0.04• I y463' o o X o —3.6T L• 0 Q O � �'T ro M N s I m ® 0 � I � j I I i I' Tc no X X to X m no c m m c � c C C C I n P n x n m 3.61°-�{ Nw 15' 43.07'- w .��an�lluli No.43M J L �71� `� �••••• I9 +' * •C* PRODUCT: Documents Pmpanuf By: %i ••••'•.;0lOgLO�:•'•• Lyndon F. Schmid! i� �O I� o Z N PLA RO INC. FlBERGLASS DOOR P.E. No. I3409 NA1.11`;``� r— ;i PART OR ASSEMBLY: rnVK BUILDING CONSULTANTS, INC. Ito p cn 1 3 9 15 UPDATE 70 57H ED. 2014 FBC JK 3—POINT LOCK DEMLS fJ V P.O. Box 230, VDlrleo, FL 33595 N NO DATE BY '"" Phone No.: 813.859.9197 ISIONS FBPE C.A. No, 9a13 0.12 R.W.SUILDINO r:DN511LTANTS IND. I • • I i R.10ients\PlastprC,Inc PERMANENT\Florida Product Approvals\R-15210 HVHZ Fiberglass-Impact Opaque and Glazed\C-Drawings\FL-15210(2014)\FL-15210.1-6.dwg,61 I I I I T W� ~C 03 t/1 � I �T m • I I I X SC � � I C: C n n = ti1 O I I A 0 I N V I 7c rn o Co O I I 24.25" 23.0' 15A° I I , I lllpunlgr� �, ti~ �"� 4 E PRODUCT: BY. '•. •• `� ;R Doeumalb PnparW PLASTPRO Lyndon F.ISahmidt 'i N FlBERGLASS DOOR P.E. No. 43409 ''i��/ 1• ���` I� o \ frrr111110111 g N r— ;—i rn PART OR ASSEMBLY: / BUILDING CONSULTANTS, INC. p v1\[NO. 3 9 15 UPDATE TO 5TH ED. 2074 FBC JK / P.O. Box 230.VDIrIco, FL 33595 IrD NDATE BY 3—POINT LOCK DETAILS vV phone No.: 813.859.9197 1��) ISIONS FBPE CJL No. 9813 2012 R.W.BIII I-DING CDNe1JLTANTe INC. I 6" f N X :J= a (T1P) 3 z * e � �m a a , °• TT f 1 1111\\ In z o a o SEE HINGE L 2X BUCK ca h v N 0 z 0 D TYP.HEAD z a a &JAMBS ... a DETAIL(TYP.) G 1X BUCK �(� E o a c w a p �'- -- - - - - - - ---- - . - ----- ---- -- iYP.-HEAD----- ------ -------'-—�----- --a�g—m-a-aoa � --- - MASONRY — =„ MASONRY &JAMBS ,, g 4 OPENING OPENING E `o i A�F`d R FRAME z m Zo S ;p fJ ti oo 2X BUCK � ~ 2X BUCK a 5 m lJ N gW w g to tJ a m o o Y ( ADA SILL & r m c ONLY n a o' m se � � t b • N • rn = a BUCKANCHORING SRUKEJAM8 FRAMEANCHORING HINGEJAMB w _o MasorW construction rn in o CONCRETE ANCHOR NOTES: S1.Concrete anchorlocotions at the comers maybe adjusted to mahtaln the min. a edge distance to mortarjoints. 1 X BUCKK< 2.Concrete onchorlocatiom ra M ted as AX.ON CENfER•must be adjusted to 9 maintain fhe min.edge distance to mortarjoints,addiffonol concrete anchors 2XBUCK _ @ o may be requlred to enwre the MAX.ON CENTER'r9mension are not exceeded. w 4 lr 3.Concrete anchor table: H 1 X BUCK 1 X BUCKtHo ANCHOR ANCHOR M!N IN CLEARANCE MIN;CLEARANCE. 2XBUCK 1IE 7ONRY TQADlACENl 2XBUCK 582X BUCK .... .:. .:.. .. ..,.EQ'fiE ........aNCHdR :r; 'Z. nD rAPcoNis 1/4ffw ' 1.1/4• r 4" 1X BUCK M D 58 2X BUCK , ,a DAM.02116112 i a ELCO 1/4' 1.1/4' 1• 4' Z7 S.• Fes\ SMQ N.T.S. 9 utrwtcoN H 1 X BUCK Dwc.er: JK m 5lTW ® 3/16' 1.1/4' 3• 1-1/r 9:Y'""t-� CHw sr: LFS 3 !? TAPCON HINGE DETAIL a IfISWInFt DRAWING NO.: 1.WOOD SCREWMSULUnONNOTES: LATCHADEADBOLTDETAIL 9 HINGEDEVIL " yMalntaln a minimum 5/8"edge distance,1'end distance,6 1"o.c.spacing of FL-15210.1 a wood screws to prevent the spGfNngofwood. OUISWIfIg• n '�V„C•,;,^ r swxr 7 OF 9 a — R:\Clients\Plastpro,Inc PERMANENT\Florida Product Approvals\FL-15210 HVHZ Fiberglass-Impact Opaque and Glazed\C-Drawings\FL-15210(2014)\FL-15210.1-Uwg,8.1 IA' 1. r 1.75' A S2 3,g0 00 00 m U m N G N O uJ N� 6 6 �IL.25- 1.75" I' 1�,11 98" zz 3 Z 05 10 N 6 5 o y 3 ICI 13' I I. - 0.65' N s f--0.15' y Ita 10 A Ote a O A 6 IN2 N W i 0.75" I 19 EeD'5!1 d 9 i z.t� `� �```11111111"I""i �. F,sCHM� No.43409 - ' GGG I��I SV,77-Cr i s $ ¢¢ Q PRODUCT: t-ft iPnparw W. `n Lyndon F.j Schmidt /i/ .......... tI N PLASTPR0 INC. P.P.E. No. 43409 // ` ( o N 'a Z FIBERGLASS DOORI. j /� ►1 y rn PART OR ASSEMBLY: mKn BUILDING CONSULTANTS, INC. I p x In 1WDATE UPDATE 70 57H ED. 2014 FBC JK r/t,l P.O. Box 230, Valrleo, FL 33595 � n� NOBY COMPONENTS / `VY Phone No.: 813.659.9197 1EVISIONS 7 \ FBPE CJL No. 9BI3 ®2012 R.W.BUILDING CONCUL-1-8 INC. \ Y I BILL OF MATERIALS •' ''' REM• oES ONON MATERM = �_ A 1X BUCK SG>=0.55 WOOD _U $ * mE B 2X BUCK SG-0.55 WOOD %��•.ti•. D 1/4"X 22-3/4 PFH ELCO OR ITW CONCRETE SCREW STEEL ////ry ����1%��``` i o'm o 0 a MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI E CONCRETE °z 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 E i m o q G_ 1/4"X 3-3/4'PFH ELCO OR ITW CONCRETE SCREW STEEL 'v 8 c g 9 w S °� � H 3/16"x3-I/4"PFH ITW CONCRETE SCREW -- STEEL-- - -- -- - - - -- - -- - ---- --- ---- --a-�a—'mda - - --- I 1/4'X 1-3/4'PFH ELCO OR ITW CONCRETE SCREW STEEL L #8 X 2-1/7'PFH WOOD SCREW STEEL ° M #8 X 1-1/7'PFH WOOD SCREW STEEL a _ 1 POLY FIBER JAMB COMP./VINYL 2 FINGER JOINTED PINE FRAME WOOD 7 WEATHERSTRIP FOAM m 8 DOOR BOTTOM SWEEP VINYL o Q LL 9 4,X 4"BUTT HINGE STEEL 3 11 #9 X 3/4'PFH WOOD SCREW STEEL a 0 22 3 POINT'TONGUE'MULTI-POINT LOCKSET)Mfg.BY HOPPE) STEEL c, 6 23 MULTI-POINT STRIKE PLATE)TONGUE SYSTEM) STEEL o m 25 LATCH AND DEADBOLT STRIKE PLATE(TONGUE SYSTEM) STEEL Q� m 27 LATCH STRIKE PLATE STEEL 0l 0 28 DEADBOLT STRIKE PLATE(SECURITY) STEEL 0 29 _ ADATHRESHOLD ALUM a 0 30 OUTSWING THRESHOLD ALUM/WOOD m g 31 OUTSWING THRESHOLD ALUM/WOOD E 32 OUTSWING THRESHOLD ALUM/WOOD 33 OUTSWING THRESHOLD ALUM/COMP a 34 OUTSWING THRESHOLD ALUMIWOOD 'o g 36 INSWING THRESHOLD ALUM/COMP rn > 37 INSWING THRESHOLD ALUM/WOOD w o 38 INSWING THRESHOLD ALUM/COMP '" El 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 55 #10 X 1-1/T PFH SCREW STEEL 9 57 BACKING PLATE STEEL !R h. 58 #8 X 7'PFH WS STEEL �, z 60 MULTI-POINT STRIKE PLATE STEEL 8 62 LOCK ASSEMBLY STEEL ,^ �3 ^w Z a DATE:02115112 1i s,• SCALE' N.T.S. F e:J s DWG.er: JK 6 p ,lk,• DRAWING NO.: qr. Sri cl T�� r FL-15210.1 0 ..` -.r SHEET 9 OF J N V