Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 File -� - QTY BCIS Home i Log In ; User Registratioq Ho[Topics Submit Surcharge Stats&Facts Publications FBC Staff `s BCIS Site Map Links ; Search r:^"LH3 �. $ `Product Approval USER:Public User 7, Tom{ Product Approval Menu>Product or Aoolication Search>Application List>Application Detail atm t`'s FL# FL13265-R2 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer James Hardie Building Products,Inc. Address/Phone/Email 26300 La Alameda Ste. 250 Mission Viejo,CA 92691 (909) 349-2927 pingsheng.zhu@jamesh ardie.com .`� Authorized Signature Pingsheng Zhu pingsheng.zhu@jamesh ardie.com Technical Representative Pingsheng Zhu Address/Phone/Email 10901 Elm Ave. Fontana,CA 92337 (909)349-2927 pingsheng.zhu@jamesh ardie.com Quality Assurance Representative Pingsheng Zhu Address/Phone/Email 10901 Elm Ave. Fontana,CA 92337 (909) 349-2927 pingsheng.zhu@jamesh ardie.com Category Panel Walls Subcategory Siding f. Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer L,6 Evaluation Report-Hardcopy Received w Florida Engineer or Architect Name who developed Ronald I.Ogawa the Evaluation Report Florida License PE-24121 Quality Assurance Entity Intertek Testing Services NA,Inc. Quality Assurance Contract Expiration Date 01/01/2018 Validated By John Southard,P.E. R Validation Checklist- Hardcopy Received Certificate of Independence FL13265 R2 COI RIO-Certificate of Indeoendence.ndf Referenced Standard and Year (of Standard) Standard Year ASTM C1186 2007 ASTM E330 2002 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL13265 R2 Equiv ASTM C1186 Equivalency Sioned.odf http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvRk6bsvZ66F... 3/14/2017 Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D F Date Submitted 04/23/2015 Date Validated 04/30/2015 Date Pending FBC Approval 05/11/2015 Date Approved 06/22/2015 Summary of Products FL# Model, Number or Name Description 13265.1 HardieSoffit Panels HardieSoffit Panels,Cemsoffit Panels; fiber-cement soffit panels Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL13265 R2 II ER RIO-2554-15 Soffit wood metal.odf Approved for use outside HVHZ: Yes FL13265 R2 II Install HardieSoffit Panel.Ddf Impact Resistant: N/A FL13265 R2 II NOA 15-0122.04.odf Design Pressure: N/A Verified By: Intertek Testing Services NA Ltd. r Other: For use in HVHZ install in accordance with NOA 15- Created by Independent Third Party: No 0122.04. Evaluation Reports FL13265 R2 AE ER RIO-2554-15 Soffit wood metal.odf FL13265 R2 AE NOA 15-0122.04.Ddf Created by Independent Third Party:Yes Back Next Contact Us::7601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement i Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: tint' Credit Card Safe http://www.floridabuilding.org/pr/pr_app_dtl.aspx?p aram=wGEVXQwtDgvRk6b svZ66F... 3/14/2017 { Florida Product Approval r. HardieSoffit° Panel • For use inside HVHZ: o HardieSoffit Panel fastener types, fastening schedule, and installation shall be in accordance with the Miami-Dade County Florida NOA 15-0122.04. Consult the HardieSoffit.product installation instructions on the follow pages for all other installation requirements. • For use outside of HVHZ, i o HardieSoffit Panel fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Report RIO-2554-15. Consult the HardieSoffit product installation instructions on the follow pages for all other installation requirements. h Florida Building Code Online Page 1 of 3 s, �:b�... ��+�.�i 5+�,��� ' • T1"n`+gi." �/W� y � A4e Y1¢ygy�..3 Co REM BCIS Home Log In User Registration Hot Topics i Submit Surcharge Stats&Facts i Publications FBC Staff BCIS Site Map Links Search �.i g Product Approval �� x�x�USER:Public User Product Acoroval Menu>Product or Aoolication Search>Application List>Application Detail FL# FL13192-R4 Lxx ._ Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer James Hardie Building Products,Inc. Address/Phone/Email 26300 La Alameda Ste.250 Mission Viejo,CA 92691 (909)349-2927 pingsheng.zhu@jamesh ardie.com Authorized Signature Pingsheng Zhu pingsheng.zhu@jamesh ardie.com Technical Representative Pingsheng Zhu Address/Phone/Email 10901 Elm Ave. Fontana,CA 92337 (909) 349-2927 pingsheng.zhu@jamesh ardie.com Quality Assurance Representative Pingsheng Zhu Address/Phone/Email 10901 Elm Ave. Fontana,CA 92337 (909)349-2927 pingsheng.zhu@jamesh ardie.com Category Panel Walls Subcategory Siding Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer J Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Ronald I.Ogawa the Evaluation Report Florida License PE-24121 Quality Assurance Entity Intertek Testing Services NA,Inc. Quality Assurance Contract Expiration Date 01/01/2018 Validated By John Southard,P.E. G Validation Checklist- Hardcopy Received Certificate of Independence FL13192 R4 COI RIO-Certificate of IndeDendence.PDF F Referenced Standard and Year (of Standard) Standard Year ASTM C1186 2007 ASTM E330 2002 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL13192 R4 Equiv ASTM C1186 Equivalency Signed odf http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtD gtsk%2bGnUu4... )/14/2017 Florida Building Code Online „� Page 2 of 3 Sections from the Code - �'- Product Approval Method Method 1 Option D Date Submitted 08/17/2015 Date Validated 08/26/2015 Date Pending FBC Approval 09/07/2015 Date Approved 10/16/2015 Summary of Products FL# Model, Number or Name Description 13192.1 Cemplank Lap Siding fiber-cement lap siding Limits of Use Installation Instructions s Approved for use in HVHZ: Yes FL13192 R4 II ER RIO-2553-15 Plank metal wood.odf Approved for use outside HVHZ: Yes FL13192 R4 II ER RIO-2557-15 Plank Shingle CMU.pdf Impact Resistant: N/A FL13192 R4 II ER RIO-2577-15 Plank to WSP Design Pressure: N/A Sheathin df Other: For use in HVHZ install in accordance with NOA 15- FL13192 R4 II Install CemPlank Siding.odf 0122.04. FL13192 R4 II NOA 15-0122.04.pdf Verified By: Ronald I.Ogawa 24121 Created by Independent Third Party: No Evaluation Reports FL13192 R4 AE ER RIO-2553-15 Plank metal wood.odf FL13192 R4 AE ER RIO-2557-15 Plank Shingle CMU.odf FL13192 R4 AE ER RIO-2577-15 Plank to WSP Sheathing.Pdf FL13192 R4 AE NOA 15-0122.04.pdf Created by Independent Third Party:Yes 13192.2 HardiePlank Lap Siding fiber-cement lap siding Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL13192 R4 II ER RIO-2553-15 Plank metal wood.pdf Approved for use outside HVHZ: Yes FL13192 R4 II ER RIO-2557-15 Plank Shingle CMU.pdf Impact Resistant: N/A FL13192 R4 11 ER RIO-2577-15 Plank to WSP Design Pressure:N/A Sheathing.odf c Other: For use in HVHZ install in accordance with NOA 15- FL13192 R4 II Install HardiePlank Siding.pdf 0122.04. FL13192 R4 II NOA 15-0122.04.pdf Verified By: Intertek Testing Services NA Ltd. Created by Independent Third Party: No Evaluation Reports FL13192 R4 AE ER RIO-2553-15 Plank metal wood.odf FL13192 R4 AE ER RIO-2557-15 Plank Shingle CMU.odf f FL13192 R4 AE ER RIO-2577-15 Plank to WSP Sheathing.pdf FL13192 R4 AE NOA 15-0122.04.odf Created by Independent Third Party:Yes 13192.3 HardieShingle Individual Shingles fiber-cement individual cladding shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL13192 R4 II ER RIO-2555-15 Shingle metal wood.pdf Approved for use outside HVHZ: Yes FL13192 R4 II Install HardieShingle Sidino.odf Impact Resistant: N/A Verified By: Intertek Testing Services NA Ltd. Design Pressure:N/A Created by Independent Third Party: No Other: Evaluation Reports FL13192 R4 AE ER RIO-2555-15 Shingle metal wood.odf Created by Independent Third Party: Yes 13192.4 HardieShingle Panel fiber-cement notched shingle panels(straight edge, staggered edge,half round edge) Limits of Use Installation Instructions Approved for use in HVHZ: No FL13192 R4 II ER RIO-2555-15 Shingle metal wood.pdf Approved for use outside HVHZ: Yes FL13192 R4 II ER RIO-2557-15 Plank Shingle CMU.pdf Impact Resistant: N/A FL13192 R4 II Install HardieShingle Siding.ndf Design Pressure: N/A Verified By: Intertek Testing Services NA Ltd. Other: Created by Independent Third Party: No Evaluation Reports = FL13192 R4 AE ER RIO-2555-15 Shingle metal wood.odf FL13192 R4 AE ER RIO-2557-15 Plank Shingle CMU.pdf Created by Independent Third Party:Yes 13192.5 Prevail Lap Siding fiber-cement lap siding http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtskp/p2b GnUu4... 3/14/2017 Florida Building Code Online Page 3 of') Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL13192 R4 II ER RIO-2553-15 Plank metal wood.Ddf Approved for use outside HVHZ: Yes FL13192 R4 II ER RIO-2557-15 Plank Shingle CMU.odF Impact Resistant: N/A FL13192 R4 II ER RIO-2577-15 Plank to WSP Design Pressure:N/A Sheathing.Ddf Other: For use in HVHZ install in accordance with NOA 15- FL13192 R4 II Install Prevail Lao Siding.odf 0122.04. FL13192 R4 II NOA 15-0122.04.Ddf Verified By: Intertek Testing Services NA Ltd. Created by Independent Third Party: No Evaluation Reports FL13192 R4 AE ER RIO-2553-15 Plank metal wood.Ddf FL13192 R4 AE ER RIO-2557-15 Plank Shingle CMU.Ddf FL13192 R4 AE ER RIO-2577-15 Plank to WSP Sheathing.odf FL13192 R4 AE NOA 15-0122.04.odf Created by Independent Third Party:Yes Back Next j Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 rThe State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: e hsek "^.amu: Credit C eir Safe Y1u IP a 1 J http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtsk%2b GnUu4... )/14/2017 u - q Fastener Spacing per Florida Cladding z Building Code.Section 2322.3 46.QOin, Framing oil I H01 71 Fastener Spacing per Florida Sheathing ' 'dMii8 0& Building Code Section 2322.3 coax Aeocptm�re tso '01- . • Irl Ptn�et Coaisd '. MC OUCTREViSED e as eouVb6bg xoidi the Fbo6& Acceptmim N* Ia'-r�xtl.d7 �(1 . '�L�31Y PfO�[SCt 4rA611t1i1 • • •1 ` "••• �3 � x, /0NA� ` �, .. �, rift FRAMING . NOMINAL 2"X 4"S-P-F WOOD STUDS 16"O.C.FASTENED WITH 3-112"16d COMMON NAILS(2 PER TOP AND FOR METAL AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE BOTTOM CONNECTION) NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) THE WALL AND SOFFIT FRAh4ES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD 1N L_ COMPLIANCE WITH THE FLORIDA BUILDING CODE 5HF117HlNG ■ NOMINAL S/S"THICK/5 PLY APA RATED PLYWOOD HARDIEPANEL,CEMPANEL,PREVAIL PANEL SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA BUILDNG CODE SECTION 2322.3 INSTALLATION DETAILS WOOD STUD CONSTRUCTION GLAD bLiz (BTHE PANEL IS FASTENED WITH2"LONG,0.723"HEAD .fames Hardie Building Products,Inc. DIAMETER,0.092"SHANK DIAMETER,CORROSION 10901 Eire Avenue RESISTmom ANT SIDING NAJLS,PLACE NAILS 6"O.C.AT Fontana,CA 92337 PANEL EDGES AND INTERMEDIATE STUDS phone,909.356.6300FMC:u NO DwB No REV sizE Fax 909-427-0634 A PNL-PLK-SOFF Creator.E.Gonzales s 1"=1'-T gate:4124/21 sH r 2 OF 12 VdALL LENGTH SEE PR4DLfC7 DESCRiPYEJ�1 f Stud Spacing at 16"O.C. HardiePanel2i,CempanelS,&Pievaiia B ETA A besto D L Panel Siding materials are nonas s .. ~518^thick/$ply APA rated fiber-cement products tested in _ ' Plywood sheathing fastened accordance with ASTM C1186 Grade If, I i 1� r�rJ �.• ( t}� `• Type A and meeting the requirements of , to metal studs as described ii �QA, cr I i tsst �~ ~ in Note 1 i the Florida Building Carie. t (; > Cada PANEL DLMEAJStOtJS Water-resistive 14ocscoA�n l� ,��t.v� i width Length Thickness WALL : i i N0. barrier perPlorida 4` 89,90' 5/16" HEIGHT ; ! i i * •`, Building Code ' s3am: 4 ees ( 'a. STATE Q' .��k Section 1404-2 pESIG_ PES_S_LIR RAtNG i ( Installation � gn Pressurei R1 20ga, 3-5/8"X 1-5/8" Metal Studs -104 psf i'� i i i•� �'�` '•-.......`'. C? j Metal C-stud r't°t Impact Resistant— " HardiePanel, y MC-DOW 8 Cempanel, Panel installed over 5,18"thick!5 ply �~ Prevail Panel APA rated plywood sheathing 3/8"Minimum Edge Distance Nails at 6"O.C.(tip.) Siding FIAF�IIi�P�iNEL_,•,CEMr?ANEL.,,,PR�!�«F'At+yELStDtNC il+ISTALI,�,'fl_Ut�D_EYAII�S ■ All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's DE pAtL a installation recommendations,and the applicable sections of the Florida Building Code. Metal studs where HardiePanei,Oempanel,Prevail Panel Siding will be installed shall be i Sheathing fastener,as designed by an Engineer or Architect,per the Florida Building Code and the requirements of this. r t described in Note 1. N.O.A. U [Note 11518"thick 15 ply APA rated plywood sheathing shall be attached to metal studs at 6"0c Coec tat panel edges and all Intermediate supports using a No.3-18,0.315"head diameter X-1-114"long y� Panel fastener,as described in bugle head screw . Note 2 . The siding panels shall be installed over 5/8"thick 15 ply APA rated plywood sheathing r 1 supported by a minimum 209a,Nominal 3-518"X 1-5/8°Meta€C-studs spaced a maximum of 16" ' 0.0. HardiePanelt�Siding ' [Note 2 ]The siding panel fastener shall be a minimum No.8-18,0.$'15"head diameter X 1-5/8" l } long ribbed bugle head screw( or screw shall have at least 3 full threads penetrating.metal r framing);the fasteners shall be spaced at 6"O.C.at panel edges and intermediate studs;the fasteners shall be driven through the 5/8"thick/5 ply APA rated plywood sheathing into metal 1 Water-resistive barrier per studs located at 16!'O,C. Florida Building Code Section Fasteners shall have a minimum edge distance of 3/8"and a minimum clearance of 2"from ,f 1404.2 comers. HARDIEPANEL,CEMPANEL,PREVAIL PANEL 6/8"thick 15 ply APA c rated INSTALLATION DETAILS METAL STUD CONSTRUCTION plywood sheathing fastened dames Hardie Building Products,Inc, to metal studs as described in Note 1. .. 10901 Elm Avenue 2-09a,3-518"X 1-5/8".Metal C-stud Fontana,CA 92337 The wall and soffit frames are to be designed Phone:909-356-6300 sZE FSCM No avec No Rev by the Architect or Engineer of Record in Fax 909-427-0634 A PNL-PLK-SOFF z compliance with the Florida Building Code. Creator:I-Gonxale5 SCALE 112^=1-0^ Date:0124/2013 syses 3 OF 12 6.001n. - 16.00in. Cladding 1 6.00in.ri ( I ( ! •! •! !• Framing 6.00in. I i•! Sheathing [ ! it 6.0 in0 . ! I I ! I . ilia Fi�eiia � i•l j•� `��4�;� ..S.. R Act No 13-41-N 67 Aar pMW NO�$ Z2 I r I �� Y >_ 1 i7 Doe o, • No. 121 ? Misaai PYadud�+stra2 STATE G _" . i.! '.i - •- E � ,* !✓RA_IUItNG NOMINAL 20 GAUGE 3-518"X 1-5/8"STEEL STUDS 16+'O.C. FASTENED WITH 5/8"WAFER HEAD SCREWS(2 PER TOP AND BOTTOM CONNECTION) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL.AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) COMPLIANCE WITH THE FLORIDA BUILDING CODE Lj-EA-T N9• �� NOMINAL 5/8"THICK;5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6"OC AT PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A HARDIEPANEL,CEMPANEL,PREVAIL PANEL 8,0.315"HEAD DIAMETER X 1-1/4`LONG BUGLE HEADSCREW INSTALLATION DETAILS METAL STUD CONSTRUCTION HEADSCREW CLADD[NG rµ+THE PANEL IS FASTENED WITH NO.a-18,0.315"DEAD James Hardie Building Products,Inc. i DIAME'T`ER X 1-518'LONG CORROSION RESISTANT _ 10901 Elm Avenue RIBBED BUGLE HEAD SCREWS(SCREW SHALL HAVE AT Fontana,CA 92337 LEAST 3 FULL THREADS PENETRATING THE METAL PhonP909-35e-6300 SIZE rscna too owi;No REV F.RAMING),PLACE SCREWS 6"O.C.AT PANEL EDGESAND INTERMEDIATE STUDS Fa34 A PNL-PLK SOFF Creator.E Gonzales SCALE 1'_.p" Date:4/24/2013 sH_i_r 4 OF 12 Stud Spacing at 46"O.C.WALL k ENGTH SEE �RC3E EtCT DcSCRtF tt�l<i D ETA L A HardiePlanktD,CempiankS,& M--'---�►f --�--- Prevai10 Plank Lap Siding materials __._.----- .i•..... _--- _._.- -; --�•--- —_-- -----__--`r-_...___..__ _�_.�.:. . ` 518"thickl5piyAPA are nonasbestos fiber-cement 1 t }rated plywood products tested in accordance with ASTM 01186 Grade it,Type A and sheathin 1111 I I g in meeting the requirements of the ' '' t i,• w i accordance with yu,8 W, �, Florida Building Code. �o WALL I oQ Florida Bail ng Code WAL_ ; i ;,( Bw1ic code s '' ,�{ ';• r, �„� Section 23223 NEL 'LQU HEIGHT ? i i i Expirics r✓ " ,'?!i �,' Water-resistive Width Len, Thickness i 1 ! ;•� barrier per Florida " i { 59-112 12' 5115 ;: i ; i Sinding Code i i t�iimYsxt l 3e Pn duPq Coubrpl }�C ?: 1 Section 14042 E7ESLGtt!PRESSUE�E RATING I — - 2"X 4"S-P-F Installation Design Pressure . .......r_. �1_ ---__ .-_-- = w''' -: 4' �` Wood Studs Wood Studs -92 psf Lap Siding Impact Resistant— �t S t�Eails at 16 O.C. �� I A`/ f SELCTIO Planks installed over 518"thick 15 ply 3!4'Minimum Edge Distance (typ•) �irririN 13�i3 1-114"#all X 5116" APA rated plywood sheathing thick starter strip DETA_lt~A Sheathing fastener,as HA1)tEPLAi!tK�CMPLANK�t?12E1t,Ali�L,4P_S_tt)I�IG� ITAI-t-A7toN l� tAtLs described in Note 1 All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's installation recommendations,and the applicable sections of the Florida Building Code Wood studs where HardiePlank,Cemplank,Prevail Lap Siding will be installed shall be designed by an j Engineer or Architect per the Florida Building Code and the requirements of this N.O.A. • [Note 11518"thick 16 ply APA rated plywood sheathing shall be attached to the studs in accordance f Siding fastener,as with Florida Building Code Section 2322.3. �v4* Fhwida ` described in Note 2 Planks shall be applied horizontally commencing from the bottom course of the wall with 1-114"wide laps at the top of the plank suet',that the exposure area of each plank is 5 8 A!'vertically. C t HardiePlank, a [Note 21 The siding fastener shall be a 2-112"long,0.223"head diameter,0.092"shank diameter, Cemplank,Prevail corrosion-resistant siding nail;The siding is fastened s 8-114"O.C.vertically and 16"O.C.horizontally; Lap Siding fasteners are driven into wood studs through 618"thick t 5 ply APA rated plywood sheathing,fasteners are placed in the overlapping area approximately 314'from the bottom edge of the overlapping plank r X Vertical joints shall be placed over studs, f/ Water-resistive barrier ■ The planks shall be installed over 518"thick 15 ply APA rated plywood sheathing supported by a - per Florida Building minimum of 2"X4"S-P-F wood studs spaced a maximum of 16"O.C. ` y Code Section 1404.2 Fasteners shall have a minimum edge distance of 3X'. \ i thick 15 ply APA rated a HARDIEPLANK,CEMPLANK,PREVAIL LAP SIDING plywood sheathing fastened INSTALLATION DETAILS WOOD STUD CONSTRUCTION ,in accordance with Florida (B Building Code Section James Hardie Building Products,Inc. 2322.3 _ 10901 Elm Avenue + Fontana,CA 92337 2"?C 4"S-F-i=Wood Studs Phone:909-356-6300s:zE �scM No ouv�No ftsv The wall and soffit frames are to be designed Fax 909-427-06 1 by the Architect or Engineer of Record in 34 ,a PNL-PLIC-SCOFF compliance with the Florida Building Code. Creator.E.Gonzales scars 1!2"=11-0" Date:4124!2013 sHEET 5 OF 12 Fastener Spacing per Florida Building Code Section 2322.3 16 in.OC--- Cladding ' I Framing -------- -' - Fastener Spacing per Florida I� g p � Sheathing Building Code Section 23223 a.75n ...................._.......:-......................... Yk20Ia1.lCTSEVLSM t $tal�isag E.od� ! l ' -41X11 0/ ..-_..._ - .._._.-__.__� _�. �• fIJ. f stir y By t I 1�8i 53.25CR. ache Pray av Cou ag wi/1h*e Fio" _y �I�I�� ♦ yt.jdY I a ♦ a I 'i •,YO. 121 \ r t STATE OF rl2AMtNG_ �. adeprodnetCari _ O " ■ NOMINAL X 4'"S-P-F WOOD STUDS 16"O.C.FASTENED WITH 3-112"16d COMMON NAILS(2 PER TOP AND �„ /QAIAL 2" BOTTOM CONNECTION) '�f.. 11��r1 THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND i fff LOAD ARE BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) � COMPLIANCE WITH THE FLORIDA BUILDING CODE �. SHFATEiING ■ NOMINAL 51$"THICK!5 PLY APA RATED PLYWOOD SHEATHING'FASTENED IN ACCORDANCE WITH FLORIDA " HARDIEPLANK,CEMPLANK,PREVAIL IAP SIDING BUILDING CODE SECTION 2322.3 INSTALLATION DETAILS WOOD STUD CONSTRUCTION r CLA.DD(JV_G. 1f PL.ANKS.OVERLAP 1-1/4" ■ THE EXPOSURE IS s8-114" James Hardie Building Products,Inc. • THE PLANKS ARE FACE NAILED WITH 2-112'LONG,x.223" 10901 Crim Avenue HEAD DIAMETER,0.092"SHANK DIAMETER,CORROSION- V 4 Fontana,CA 92337 RESISTANT SIDING NAILS,'PLACED 314"UP FROM THE Prone'909-355-6300 size FScm NO MG NO REV BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION Fax 909427-0634 A PNL-PLK SOFF 4 Creator:E Gonzales SCALC V=1'-0" Date:4124!2013 SHEET o OF 12 bW LL LENGTH SEE PE�ODUC7 DESC�2Ii?TiQhi Stud Spacing at 16'O.C- DETAILA HardiePlankO, Cemplank®,and yrs"thick!5 ply APA Prevail®Plank Lap Siding materials are nonasbestos fiber-cement ..___.._-_ -----i---- --_ — ---•----- —___ _--- .._-- _-__ i.._.._.._ 1 rated eaplymod fastened products tested in accordance with i i' ,shmetal ASTM C1186 Grade It,Type A and to rrrrrr meeting the requirements of the ?. 0, %� described in Note 1 Florida Building Code. I j t E as aop} y�g.vi$,ici�3ocedet O�O�b �N. a .IF- Yv f. Water-resistive WALL .i ! 'i,+ All '' _ barrier per Florida PICNIC DtMENSIOEJS, HEIGHT i' i O ��� Bulding Code Width Length Thickness Section 1404.2 5 9-1/2" 12' 5116'• ! i Yip20ga,3-5t8"X 1-5w. DESIG,N PRESSURE RATING i i ; i.i •i.. Metal Gstud i ! , i Installation Design Pressure ! ! �.i� ``� HardiePlank, Metal Studs -92 psf p ,Prevail B 1- -►� r : Lap Siding Impact Resistant— ` 3/4"Minimum Edge Distance Nails at 16"O.C.(typ.) .,IONaL c } '`-g gC 1-1/4'tal X�t16" Planks installed over 518 thick 15 pI}s .. '"rrrr thick starter strip APA rated plywood sheathing t1v D5TAI_L_A HARDIEPLANK CEMPLANK.PRE�/AIL LaP S[DING INSIALLAT10tJ DERAILS A I installation shall be done in conformance with this Notice of Acceptance,the manufacturer's installation Sheathing fastener,as recommendations,and the applicable sections of the Florida Building Code. described in Note 1 Metal studs where HardiePlank,Cemplank, Prevail Lap Siding will be installed shall be designed by an PRL>buer �� Engineer or Architect per the Florida Building Code and the requirements of this N.OA av FF ago-Wyav �F106ft �� [Note 1]518"thick/5 ply APA rated plywood sheathing shag be attached to metal studs at 6"oc at panel \ edges and all intermediate supports using a No.8-18,0.315"head diameter 1-114"long bugle head screw S-OJ Siding fastener,as Planks shall be applied horizontally commencing from the bottom course o:the wail with 1-114°wide laps at 1 described in Note 2 the top of the plank such that the exposure area of each plank is:!;8-1/4"vertically. j [Note 21 The siding fastener shall be a minimum No-8-18,0.315"head diameter X 2-114°long"bugle head i�ai Pioduacmaul screw over metal studs("or screw shall have at least 3 full threads penetrating metal framing);The siding is 1 HardiePlank, fastened s 8-1/4"O.C.vertically and 16"O.C.horizontally;fasteners are driven into metal studs through 5/8" Cemplank, thick 15 ply APA rated plywood sheathing,fasteners are placed in the overlapping area approximately 3/4" Prevail Lap Siding from the bottom edge of the overlapping plank. Vertical joints shall be placed over studs. Water-resistive ■ The planks shall be installed over 518"thick 15 ply APA rated plywood sheathing supported by a minimum ,\ 20ga,Nominal 3-5/8"X 1-5/8"Metal C-studs spaced a maximum of i6"O.C. barrier per Florida Fasteners shall have a minimum edge distance of 318'. Building Code Section 1404.2 ` HARDIEPLANK,CEMPLANK,PREVAIL LAP SIDING 5/8"thick 15 ply APA rated INSTALLATION DETAILS METAL STUD CONSTRUCTION plywood sheathing fastened to metal studs as described in James Hardie Building Products,Inc. _ 10901 Elm Avenue Note 1 ® Fontana,CA 92337 toga,3-518!'X 1-5/8"Metal C stud Phone:909-355-6300 s1zE FSCM NO bws NO REV The wall and soffit frames are to be designed Fax 909-427-0634 A PNL-PLK-SOFF 1 ! by the Architect or Engineer of Record in i compliance with the Florida BuIding Code. Creator.E.Gonzales SCALE 112"C 1'-0" Date:4/24t2013 sNeEr 7 of 12 6.00in. 16 in.OC Ciadd"ing ' 6:4In. j I Framing I 6,O� lj OinAG I � Sheathing 0.75n _. __._............... .._----------------_----- ------ I fJl//J/1r��� J ---- -..—------- ----------------- -_.- - ---------------------------- ,4�4' QCA fns REVtSED Z. an COW00mg wi&the fkw �wilt Iie Florins �C 13m�g C� �� Ac=pcwm No 1—:1 is-t/.•f � 4 o. 121 ----•------------- .,................. ii � •'`• iiAmek rodesciGcatrot trdwMlirfak Anodmcaurd TATE OF :'Z; �ORtC��` e)istAt,.. = NOMINAL 20 GAUGE 3-518!'X 1-5/8"STEEL STUDS 16" O.C.FASTENED WITH EW LONG RIBBED BUGLE HEAD SCREWS(2 PER TOP AND BOTTOM CONNECTION) = THE WALL AND SOFFIT FARES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING �� NOMINAL 518"THICK 15 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT 6"OC AT.PANEL I EDGES AND ALL INTERMEDIATE SUPPORTS USING A NO.8-18,0.3'15"HEAD DIAMETER X 1-114"LONG BUGLE I HEAD SCREW HARDIEPLANK,CEMPLANK,PREVAIL LAP SIDING cuaaDlNG INSTALLATION DETAILS METAL STUD CONSTRUCTION K PLANKS OVERLAP 1-114" = THE EXPOSURE IS:5 8-114" James Hardie Building Products,Inc. r THE PLANKS ARE FASTENED WITH No.8.18,0.318" 10901 Elm Avenue HEAD DIAMETP-R X 2-114"LONG CORROSION- RESISTANT RIBBED BUGLE HEAD SCREWS(SCREW Fontana,CA 92337 SHALL HAVE AT LEAST 3 FULL THREADS Phone:909-356-6300 SIZE r-SCM.ho OWGs no REV PENETRATING THE METAL FRAMING),PLACED 3!4"UP Fax 909-427-0634 A PNL-PLK-SOFF 1 FROM THE BOTTOM EDGE,OF THE PLANK AT EACH Creator_E.Gonzales SCALE 1"=1'-0" Date:4t2412a13 srlsEz s OF 12 STUD LOCATION 4—WALL LENGTH SEE PRQ AL&-T-DLk!j!QR-LP—TLQIA Stud Spacing at 61'O.C. DETAJLA HardieSoffit(D&Cemsoffit&materials are nonasbestos fiber-cement products tested in accordance with ASTM 01186 Grade 11,Type A ---------------- and meeting the requirements of the Florida Building Code. IJ Eff T_QLMENq L 2"X 4?'S-P-F Width Length Thickness WALL Wood Studs 48' IMP HEIGHT PASIGN LRRFM50-jE-PRARN-1Z HardieSoffit, Installation Design Pressure Cerrisoffit Wood Studs 70 psf !j ---------- Off C J B SE jj-Qt-jZ=8 Nails at 4!'O.C.(typ.)jpR00kXT UEVLSW PRODUCrREVISM $/8"Minimum Edge Distancea CCOOYVS W1*do Fk" admics CO& eundifaig No. 21 A—Vftrft No[-3.&I'll 4 E - - - * 0,ft f STATE OF By 4.c./ By A, % LOR 4Y 0 10 IN At. Soffitfastener,as IL AG installation shall be done in conformance with this Notice of Acceptance,the manufacturer's described in Note I installation recommendations,and the applicable sections of the Florida Building Code, a Wood studs where HardieSciffit,Cemsoffit will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.Q.A. tThe soffit shall be installed over minimum 2"X4"S-P-F wood studs spaced a maximum of 16"0.C. ■f HardieSoffit,Cemsoffit v - (Note 11 The soffit fastener shall be a 27 long,0.223"head diameter,0.092"shank diameter, corrosion resistant siding nail',the fasteners shall be spaced at 4!'O.C.at panel edges and intermediate studs;the fasteners shall be driven into wood studs located at 16"d.C. • Fasteners shall have a minimum edge distance of 318"and a minimum clearance of 2"from comers.," HARDIESOFFIT,CEMSOFFIT PANEL INSTALLATION DETAILS WOOD STUD CONSTRUCTION Minimum 21,X 41 S-P-F Wood Studs James Hardie Building Products,Inc. The wall and soffit frames are to be 10901 Elm Avenue designed by the Architect or Fontana, CA 92337 Engineer of Record in compliance Phone:909-356-6300 s,zE Fsch, DAS NO REV with the Florida Building Code. Fax 909-427-0634 A PNL-PLK-SOFF Creator.E.Gonzales 11Z,=V-0" Date:4/2412013T- SHEET 9 OF 12 4.001n ?6.00in. Cladding t • i • i s • w . • . Framing- 4.00PRcbUtTwcV1SM m a B11041#ybg Mrit the»ion PIRO}E�Y TCR ly,i `. �+ CoAe as ooe�`iiogwnh+�1 � I A��?iai Awa„NO t73 ta,0, No. �c1 STATE OF �•��: NOMINAL 2"X 4"S-P-F WOOD STUDS 16"O.C.FASTENED WITH 3-112"16d COMMON NAILS(2 PER TOP AND BOTTOM FOR METAL AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE CONNECTION)• NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) - THE WALT.AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE GLADDlNIG THE SOFFIT IS FASTENED WITH 2"LONG,0.223'HEAD HARDIESOFFIT,CEMSOFFIT PANEL DIAMETER,0.092"SHANK DIAMETER,CORROSION INSTALLATION DETAILS WOOD STUD CONSTRUC'T'ION RESISTANT SIDING NAILS,PLACE NAILS 4"O.G.AT PANEL (R EDGES AND INTERMEDIATE STUDS • James Hardie Building Products,Inc. 10901 Elm Avenue Fontana,CA 92337. Phone:909-356-6300 SIZE FSCM NO Dws NO REv Fax 909-427-0634 A PNL-PLK-SOFF i Creator.E Gonzales SCALE i"=1=0•" Dale:4/24/2013 SHSE 10 OF 12 LENGTH— SEE Stud Spacing at 16"O.C. DETAILA HardieSoffitT&CernsoffitO materials 8.4-, are nonasbestos fiber-cement products ------------ tested in accordance with ASTM 01186 —- Grade 11,Type A and meeting the requirements of the Florida Building Code. Wall 20g2,3-5/8"X 1-! WALL Metal Stud Width Length Thickness C- HEIGHT HardieSoffilt, AE�qLqN I�IREjgSTLN Cemsoffit Installation Design Pressure Metal Studs N SE__C1LQN_B=5X % Nails at V,O.C.Qyp.) PROW=CRE "s com*yi%with the FkKids %X v#0tbtFkwWkEkni(fi"GD& 318"Minimum Edge Distance i A=ptaw N, 13 121 All 4 z9v OF All installation shall be done in conformance with this No' Accepn aturer's installation recommendations,and the applicable sections of the Florida Building Code. Soffit fastener,as x Metal studs where HardieSoffit,Cernsoffit Wit be installed shall be designed by an Engineer or described in Note I Architect per the Florida Building Code and the requirements of this N.OA a The soffit shall be installed over minimum 20ga,Nominal 3-5/8"X 1-5/8"Metal C-studs spaced a maximum of 161,O.C. HardieSoffit,Cemsoffit IN [Note 11 The soffit fastener shall be a minimum No.8-18,0.3150 head diameter X 1-1/4*long* ribbed bugle head screw(,'or screw shall have at least 3 full threads penetrating metal , framing),,the fasteners shall be spaced at 6"O.C.at panel edges and intermediate studs,the fasteners shall be driven into metal studs located at 16"O.C. Fasteners shall have a minimum edge distance of 318" a minimum clearance of 2"from comers. HARDIESOFFIT,CEMSOFFIT PANEL INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building Products,Inc. 20ga,3.5/8,,X 1-518"Metal C-stud 10901 E*Im Avenue The wall and soffit frames are to beFontana,CA 92337 designed by the Architect or Engineer Phone:909-356-6300 SIZE FSCM NO Mr.140 REV of Record in compliance with the Fax 909-427-0634 A PNL-PLIC-SOFF Florida-Building Code. I -_ Creator.E.Gonzales SCALE' 1/2"=1'-0° Date:412412 11 OF 12 M 6,aom. 16.00in. Cladding • Framing " • r M 7- • r 6.001n. P6 eDUCr REVISED Ijag mptow n�$ / x; slho ¢flr�fJsllrll�,y�r. AN I• sE�yy 47 By � — T�adc�tu�aeCvmnati f , 2 SIP���, :���� 10 11 F�Qe 0— NOMINAL 20 GAUGE 3-518"X 1-518"STEEL STUDS 16"O.C. FASTENED WITH 5(8"WAFER HEAD SCREWS(2 PER TOP FOR METAL AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE AND BOTTOM CONNECTION) NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE CI,ARDING THE SOFFIT IS FASTENED WITH NO.8-18,0.315"HEAD HARDIESOFFIT,CEMSQFFIT PANEL DIAMETER 1-114 p LONG CORROSION RESISTANT RIBBED INSTALLATION DETAILS METAL STUD CONSTRUCTION BUGLE HEAD SCREWS(SCREW SHALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMING), PLACE James Hardie Building Products, Inc. SCREWS 6"O.C.AT PANEL EDGES AND INTERMEDIATE 10901 Elm Avenue STUDS ° Fontana,CA 92337 Phone.909.356-6300 WE FSCM NO DWG NO REV Fax 909.427-0634 A PNL-PLK SOFF 4 Creator.E Gonzales srras 1"=1'-U" Dafa:4l24120'I3 smEer 12 OF 12