HomeMy WebLinkAboutEngineering, product approvals L. Roberto Lomas P.E. Engineering Evaluation Report 1432 Woodford Rd. Lewisville NC,27023 Report No.: 513975 434-688-0609 Rllomas@lrlomaspe.com Manufacturer: MI Windows and Doors LLC 650 West Market Street Gratz,PA 17030 Product Line: Series 120/130/140 Aluminum Sliding glass door=Impact Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a).The product listed herein complies with requirements of the current Florida Building Code. Supporting Technical Documentation. 1. Approval documents:drawing numbers 08-03086,prepared,signed and sealed by Luis Roberto Lomas P.E. 2. Report No.: 1196.01-106-11 signed and sealed by Michael D.Stremmel,P.E. Molimo.LLC,York PA. AAMANVDMA/CSA 101/I.S.2/A440-08 Design pressure: t55.13psf Water penetration resistance 2.92psf(standard sill) Water penetration resistance 8.36psf(2 5/8"sill extender), Water penetration resistance 9.82psf(3 1/2"sill extender) 3. Report No.: 1196.02-106-11 signed and sealed by Michael D.Stremmel,P.E. Molimo.LLC,York PA. AAMA 5MA I ASTM E1886-05 and ASTM E1996-12 ASTM E1886/E1996 Large Missile Impact,Level D,Wind Zone 3 ASTM E1886/E1996 Cyclic Load Test,t55.Opsf design pressure 4. Anchor calculations,report number 513975-1, prepared,signed;and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: ➢ +15.0/-55.Opsf(standard sill in areas where water penetration resistance is required) ➢° t55.Opsf(2 518"and 3 112"sill extender in areas wherei water penetration resistance is required) ➢ t55.Opsf(standard sill,2 5/8"and 3 1/2"sill extender in areas where water penetration resistance is not required) • Maximum panel size: 48 5/8"x 93 1/2" • Approved configurations: OX,XO,XX,OXXO,PX,XP,PXXP, PIX,XIP, PIXXIP,XIX,OIX,XIO, PIIX,XIIP,XIIX,OIIX,XII0,1 PIIIX,XIIIP • Units must be glazed per ASTM E1300-04/09.See installation instructions for glass details. • This product is not rated to be used in the HVHZ. i • This product is impact resistant and does not require impact protection in wind borne debris regions. • Frame material-to be Aluminum 6005-T5. Installation:Units must be installed in accordance with manufacturer's in, instructions and approval document 08-03086. �t1t1111!!/ Certification of independence: Please note that I don't have nor will!acquire a \\ -, L financial interest in any company manufacturing or distributing the products)for whichE IV ��ti Jt$«• • • ;t1 this report is being issued.Also, I don't have nor will acquire a financial interest in any S ` dy other entity involved in the approval process of the listed product(s). « ✓ *• 0 5 %7�or • TAT 'OF i•g • . . .� 1 of 1 Luis R.Lomas, P.E. FL No.:62514 06/06/2017 i i m AAMA (ValidatorI Operations Administrator) CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT,CERTIFICATION i MI Windows&Doors,LLC P.O.Box 370 Gratz,PA 17030-0370 Attn: Rick Sawdey This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an AAMA Accredited Laboratory.The product information below will be added to the next update of the AAMA Certified Products Directory. SPECIFICATION AAMA/WDMA/CSA 101/I.S.2/A440-08 RECORD OF PRODUCT TESTED R-PG15-3678x2438(145x96)-SD Negative Design Pressure=-55 psf COMPANY AND CODE CPD NO. SERIES MODEL S PRODUCT MAXIMUM SIZE TESTED DESCRIPTION MI Windows&Doors,LLC 120/130/140 SGD FRAME PANEL 16372 (AL)(OXO)(OG)(INS GL) 3678 mm x 2438 mm 1235 mm x 2375 mm Code:MTL (ASTM) (12'1"x 8'0") (44"x 7'10") This Certification will expire February 8,2022 and requires validation until then by,continued listing in the current AAMA Certified Products Directory. Product Tested and Reported by: Molimo,LLC Report No.: 1223.02-106-12 Date of Report: March 7,2017 Evaluated for Certification: March 28,2017 4-4� ,h, A oci ted Laboratories,Inc. Authorized for Certification: March 28,2017 JGS/JTS ACP-04 (Rev.6/16) A n Architectural Manufacturers Association I i REVISIONS REV OESCRfPIiON DATE APPROVED NOTES: 15. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1 REQUIREMENTS OF THE FLORIDA BUILDING CODE. 7/8" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY INSTALLATION DETAILS. TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 16. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #14 SMS OR SELF 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED ALL FS, 17. ALL FASTENERS TO BE CORROSION RESISTANT. INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO 18. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN 5. WHERE WOOD BUCK THICKNESS IS 1-1/2' OR GREATER, BUCK SHALL BE SECURELY SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH'SPECIFIED BELOW: - _ FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH - B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. — 6. WHERE 1 X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF ALUMINUM 6063—T5 FU=30KSI .048" THICK MINIMUM THE ARCHITECT OR ENGINEER OF RECORD. 19. APPROVED CONFIGURATIONS: OX, XO, XX, OXXO, P%. XP, PXXP, PIX, XIP. PIXXIP, XIX, OIX, 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS XIO, PIIX, XIIP, XIIX, OIIX, XIIO, PIIIX, XIIIP PROVIDED. 20.DOOR ASSEMBLIES INSTALLED IN AREAS WHERE OVERHANG RATIO IS EQUAL OR GREATER 8. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD THAN 1.0 DO NOT REQUIRE WATER INFILTRATION RESISTANCE. BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS, MAXIMUM ALLOWABLE OVERHANG RATIO = OVERHANG LENGTH/OVERHANG HEIGHT. SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED ALUMINUM 6005—T5. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 24 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #14 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED:0611412017 MI WIN690DWEsS MARKET OSTORS REE7 LLC `,*`"'i R tlL'd/v J/ — GRATZ, PA 17030 TABLE OF CONTENTS SERIES 120/130/140 ALUMINUM SLIDING } VAT? GLASS DOOR — IMPACTNOTESSHEET NO. DESCRIPTION yO ?F ` 2 ' 3 ELEVATION. ANCHORING LAYOUTS AND CHARTS R S °Nc No.R.S. 08-03086 REV 4 PLAN VIEWS x—NTS mYE 04/13/17 sNEEr1 OF 24 thijl5t���t 5 — 23 INSTALLATION DETAILS L ROBERTO LOMAS RE, Luis R. Lomas P.E. 1432 24 GLAZING AND SILL RISER DETAILS 4,U-88-os09 dram s@kfa asps."23 FL No.: 62514 at�naaNs REV OE9CRIPIION DATE APPROVED (� �{� 191" MAX FRAME WIDTH MAX 6" MAX I I I MAX60.C- 6" 6" MAX Charttll:Units with 2 panels (2) ANCHORS Number of anchor locations required(2 anchors per location �J PER LOCATION Frame Frame Width can SEE CHARTS "eight 400 1 60.00 1 7200 1 84.00 1 9&00 #1, #2 & #3 (in) H&S Jamb H&S Jamb IN&S Jamb H8S Jamb H8S Jamb FOR NUMBER 80.00 a s a s 6 s s s 7 s 00 0 OF LOCATIONS 64.99 4 s a s 5 6 e s 7 6 gO,Op 4 6 4 6 5 8 8 8 7 6 96.00 4 7 4 7 6 7 8 7 7 7 96" 16" MAX MAX O.C. FRAME t — H EIGHT O �/ �/ V Chart#2:Units with 3 panels Number of anchor locations required 2 anchors per location Frame Frame Width(in) it Height 10&00 f2& 144.00 mb H Jamb NBS[Jamb in HSJmb - S0.00 6 8 6 6 7 6 g 8 10 6 8A00 6 6 6 6 7 16 9 6 1 10 6 90.00 6 6 6 6 7 67 9 8 10 6 9&00 57 8 7 7 9 7 10 7 6" MAX Chart 03:Units with 4 panels Number of anchor locations required 2 anthers per location SERIES 120 ALUMINUM SLIDING GLASS DOOR-IMPACT 2,3,&4 TRACK O(XXX) Frame Frame Width(11) EXTERIOR VIEW Heigh 1 120.00 1 1"00 16&00 192-00 FINLESS&FLANGE INSTALLATION n N 8 S Jamb I H 8 S I Jamb I H&S I Jamb H&S Jamb H&S Jamb 80.00 7 6 8 1 6 1 10 6 11 6 13 6 64.E 7 6 8 6 10 6 11 6 13 6 90.1 7 6 8 6 10 6 11 5 13 6 WITH STANDARD SILL WITH 25/8"&3 112"SILL EXTENDERS 9&00 7 7 8 7 10 7 71 7 13 7 DESIGN PRESSURE RATING IMPACT RATING DESIGN PRESSURE RATING IMPACT RATING LARGE AND SMALL LARGE AND SMALL t 15.0%55.OPSF MISSILE IMPACT t55.OPSF MISSILE IMPACT MISSILE LEVEL D,WIND ZONE 3 MISSILE LEVEL D,WIND ZONE 3 SIGNED:0611412017 WHERE WATER PENETRATION RESISTANCE IS REQUIRED . WHERE EATER PENETRATION RESISTANCE IS REQUIRED MI WINDOWS AND DOORS LLC WITH STANDARD SILL,2 518'&31/2"SILL EXTENDERS 650 WEST MARKET STREET \ .••:•".q1 /< DESIGN PRESSURE RATING IMPACTRATING GRATZ, PA 17030 `w` . �CENs :?�'� SERIES 120/130/140 ALUMINUM SLIDING ? *G NOTES: #55.OPSF LARGEANDSMALL GLASS DOOR — IMPACT 1. MAXIMUM PANEL SIZE.48L 5/8"x 93112" MISSILE IMPACT ELEVATION � f.�'.CTAT OF�y'ttr� 2. MAXIMUM D. O.:a0 5/8"x 851/2' mz MISSILE LEVEL D.WIND ZONE 3 lwN. DWG NO. atv %ASyi'•; 0(�►OA•S� WHERE WATER PENETRATION RESISTANCE IS NOT REQUIRED R s. 08-03086 scu.E NTS bA- 04/13/17 SHET2 OF 24 �4/Y�11AIA��`` HARDWARESCHEDULE LROBERTOLOMASP.E. Luis R. Lomas P.E. A.ITANDEM ROLLER ASSEMBLY,2 PER PANE 8'FROM EACH END OF BOTTOM RAIL 1432 WOODFORD RD LEMSVILLE,NO 27023 FL No.: 62514 B. LOCK HFWDLE 1 PER OPERABLE PANEL AT LOCK STILE 39"FROM THE BOTTOM RAG__ 434-688-0609 dl mas@trfomaspe.cam REVISIONS REV DESMIMON DA1E N'PflWED 191" MAX FRAME WIDTH 6" MAX 16" 6" MAX—� MAX O.C. r——— ————————— � I 6" MAX HOOK STRIP I (1) ANCHOR I PER LOCATION SEE CHART I SHEET22 FOR I NUMBER OF I 1 16" LOCATIONS I 96" I MAX O.C.MAX I FRAME I T— HEIGHT I - I - I POCKET UNDER POCKET UNDER I I SEPARATE 4PPROVAL SEPARATE APPROVAL I TO BE REVIEWED BY OP TO BE REVIEWED BY I I BUILDING OFFICIAL BUILDING OFFICIAL I 0/0 I II I � I 6" MAX HEAD AND SILL (2) ANCHORS SERIES 120 ALUMINUM SLIDING GLASS DOOR-IMPACT 2,3,&4 TRACK(PIXXIP) PER LOCATION. SEE CHART #1, #2 & #3 EXTERIOR VIEW FOR NUMBER OF LOCATIONS FINLESS&FLANGE INSTALLATION WITH HOOK STRIP WITH STANDARD SILL WITH 2 518"&3 1/2'SILL EXTENDERS DESIGN PRESSURE RATING I IMPACT RATING DESIGN PRESSURE RATING IMPACT RATING +15.0%55.OPSF LARGEANDSMALL ±55.OPSF LARGEANDSMALL MISSILE IMPACT MISSILE IMPACT MISSILE LEVEL D,WIND ZONE 3 MISSILE LEVEL D,WIND ZONE 3 SIGNED:O6/14/2017 WHERE WATER PENETRATION RESISTANCE IS REQUIRED WHERE EATER PENETRATION RESISTANCE IS REQUIRED WITH STANDARD SILL,25/8"&31/2'SILL EXTENDERS MI WINDOWS AND DOORS LLC \5�`�RUtLI0 650 WEST MARKET STREET vt i DESIGN PRESSURE RATING IMPACT RATING GRATZ, PA 17030 LARGEANDSMALL SERIES 120/130/140 ALUMINUM SLIDING ±55.OPSF GLASS DOOR — IMPACT MISSILE IMPACT NOTES: " k ELEVATION r ' 1. MAXIMUM PANEL SIZE:48 5/8"x 93 1,2" MISSILE LEVEL 0.WIND WHERE WATER PENETRATION RESISTANCES NOT REQUIRED MWN: DWG NO. REV 2. MAXIMUM D.L.O.:405/8'x85112' R.S. 08-0 086 `1 SCALE NTS �� 04/13/17 3 OF 24 It HARDWARE SCHEDULE L ROBERTO LOMAS P.E. Luis R. Lomas P.E. A. TANDEM ROLLER ASSEMBLY.2 PER PANEL,8'FROM EACH END OF BOTTOM 1432 WOODFORD RD LEWISVILLE,NC 27023 FL No.: 62514 B. LOCK HANDLE 1 PER OPERAB.LE_FANEL AT LOCK STLE.�39'FROMTHE BOTTOMRIUI 4?afiBB'Gfi09 Namespl4amaspe.cam REVISIONS REV OESCRIPIION DATE APPROYEO POCKET POCKET POCKET XO (OX OPPOSITE) XX XIP (PIX OPPOSITE) PXXP POCKET POCKET POCKET — - -- XP (PX-OPPOSITE) - - __. PIMP OXXO POCKET i XIX XIO (OIX�OPPOSITE) PIIX (XIIP OPPOSITE) LAYOUTS SHOWN AS REFERENCE ONLY, PANELS MAY BE MIXED& MATCHED AS NECESSARY XIIO_ (OIIX OPPOSITE) XNX SIGNED:06/14/2017 MI WINDOWS -AND DOORS LLC _ �N,,151 �F+ O/i��! 650 WEST MARKET STREET 0at GRATZ, PA 17030 =Fv,... SERIES 120/130/140 ALUMINUM SLIDING *� ! POCK GLASS 000R — IMPACT PLAN VIEWS s RT OF. nR,avrt nwc Nn. REV 9A* q - -.-: ` os-oEoss 'Zirsz4 a NTS — 04/13/17 4 OF 24 PIIIX (XIIIP OPPOSITE) LRo9ERDLCM710 A UF_ Luis R. Lomas P.E. 1492 WDODFORD RO LE4'�SVfLCt;NC 27023 FL No.: 62514 4N-6W-0609 Alamas@UbmaVO-Com 5/8" MIN. APPROVED WOOD FRAMING ~—ter EDGE DISTANCE OR 2X BUCK BY OTHERS 1 3/8" MIN. EMBEDMENT 1 3/8" MIN. 1/4" MAX. EMBEDMENT SHIM SPACE BACKER ROD 1/4" MAX, & APPROVED SHIM SPACE 5/8" INTERIOR SEALANT MIN, EDGE DISTANCE #14 WOOD SCREW #14 WOOD EXTERIOR SCREW NNW WOOD FRAMING INTERIOR OR 2X BUCK BY OTHERS EXTERIOR NOTES: 1. INTERIOR AND EXTERIOR FINISHES,BYOTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE BACKER ROD DESIGNED IN ACCORDANCE WI7HASTME2112 & APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION #14 WOOD SCREW SILL TO BE SET l IN A BED OF APPROVED SEALANT BACKER ROD & APPROVED 1/4" MAX. SEALANT SHIM SPACE SIGNED:06/14/2017 MI WINDOWS AND DOORS -LLC - - - �X%%'1I}j1Ir+l - -- 1 3/8" MIN \� EMBEDMENT 650 WEST MARKET STREET ��V�C:• .�y�ii GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING WOOD FRAMING GLASS DOOR — IMPACT INSTALLATION p+ AT '3 OR 2X BUCK 2 TRACK FINLESS INSTALLATION DETAILS E' • .' BY OTHERS 5/8" MIN EDGE DISTANCE DRAWN: Dwc No. REV ''/�'1► o df1 VERTICAL CROSS SECTION OS— — ✓t�fS�pNAL`ti!\ti NTS �� 04/13/17 s 03f086 5 OF 24 WOOD FRAMING OR 2X BUCK INSTALLATION L ROBERTO LOMAS RE Luis R. Lomas P.E. IC2 WOODFORD RD LEWISVILLE,NC 27023 FL No.: 62514 434-688-0609 dbMm @lrloMspecom REVISIONS 5 8" MIN. EDGE DISTANCE �' D�RnDN w,� aPrRovm METAL STRUCTURE 1/4" MAX BY OTHERS SHIM SPACE BACKER ROD 1/4" MAX. 5/I8" INTERIOR & APPROVED SHIM SPACE SEALANT MIN. EDGE DISTANCE #14 SMS OR SELF DRILLING SCREW #14 SMS OR EXTERIOR — SELF DRILLING SCREWS-- - i INTERIOR EXTERIOR NOTES. METAL STRUCTURE 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, BY NOT SHOWN FOR CLARITY. OTHERS Myf-7M�-- 2 PERIMETER AND JOINT SEALANT BY OTHERS TO BE BACKER ROD DESIGNED INACCORDANCE W17HASTME2112 & APPROVED JAMB INSTALLATION DETAIL SEALANT METAL STRUCTURE INSTALLATION #14 SMS OR SELF DRILLING SCREW SILL TO BE SET N A BED OF APPROVED SEALANT BACKER ROD & APPROVED SEALANT r 1/4" MAX. SIGNED:0611412017 --- —L SHIM SPACE MI WINDOWS AND DOORS LLC - 650 WEST MARKET STREET GRATZ, PA 17030 �,`}."r,I-'ve .9ipSr� SERIES 120/130/140 ALUMINUM SLIDING 1k* 0 6 �' META GLASS DOOR — IMPACT �. = STRUCTURE a� 2 TRACK FINLESS INSTALLATION DETAILS + BY OTHERS 5/8" MIN. 0 i '�f�, EDGE DISTANCE DRAWN: DWG NO. REV 'I'c•;�6pRtdt;+��`ti VERTICAL CROSS SECTION DATE Os 503086 ZNIONA 111 METAL STRUCTURE INSTALLATION NTS 04/13/17 OF 24 6 L ROBERTO LOMAS P.E. P.E. P Lomas 1432 WOODFORD RD LEWISVII.LE,NC27023 Luis R.FL No L as 434-868-0609 dlomos@IAomaspamm 2 3/16" MIN 1 7/8" MIN. REVISIONS SEPARATION EDGE DISTANCE 1 REv oescr�DON are ARrRovEo CONCRETE/MASONRY a a BY OTHERS a a•: • ' 1 1/4' MIN. 1 1/4" MIN. `a• _ EMBEDMENT EMBEDMENT 1/4" MAX. OPTIONAL 1X BUCK : a-a .4 << SHIM SPACE SEE NOTES 3 - 7 SHEET 1 1 7/8" o BACKER ROD 1/4" MAX. MIN. INTERIOR a: APPROVED SHIM SPACE EDGE a SEALANT DISTANCE c. v 1/4" TAPCON d 2 3/16" MIN oa EXTERIOR SEPARATION NY OPTIONAL 1 X BUCK SEE NOTE 3 — 7 "0 SHEET 1 e EXTERIOR INTERIOR 1/4- TAPCON d CONCRETE/MASONRY BY OTHERS BACKER ROD & APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION 1/4" TAPCON SILL TO BE SET I IN A BED OF APPROVED SEALANT NOTES: 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE BACKER ROD 1/4" MAX. DESIGNED IN ACCORDANCE WTTHASTME2112 SIGNED:06/14/2017 & APPROVED SHIM SPACE — -- - SEALANT MI 650DWEss MARDKET DOORS STOREET�C -.N —� GRATZ. PA 17030 OPTIONAL 1X BUCK `• �� 1 1/4" MIN SERIES 120/130/140 ALUMINUM SLIDING n o GLASS DOOR — IMPACT SEE NOTE 3 — 7 •' EMBEDMENT : AT IF, SHEET SHEET 1 2 TRACK FINLESS INSTALLATION DETAILS �a.�. 4a' a ,a • `a y -• .a• a... .' '.. .. DRAWN: 0180 ND. REV yP�a QE;t�;at� CONCRETE/MASONRY ^!.. - . R.S. Q 08-03086 BY OTHERS 2 3/16° MIN 1 7/8 " MIN a� SNEEr SEPARATION EDGE DISTANCE NTS 04/13/17 7 OF 24 L.ROBERTO LOMAS AE. Luis R. Lomas P.E. VERTICAL CROSS SECTION 1432 WOODFORD RD LEWISVILLE,NC 27023 FL No.: 62514 CONCRETEAAIASONRYINSTALLAITON 434-688-0609 Af0ma9@lrloma9p9.aom REVISIONS 5/8" MIN. REV DESCRIPTION UAre � WOOD FRAMING EDGE DISTANCE OR 2X BUCK BY OTHERS 1 3/8" MIN. EMBEDMENT 1 3/8" MIN. {� 1/4" MAX. EMBEDMENT I SHIM SPACE BACKER ROD 1/4" MAX & APPROVED SHIM SPACE 5/8" INTERIOR MIN. EDGE DISTANCE #14 WOOD SCREW #14 WOOD EXTERIOR - - SCREW WOOD FRAMING INTERIOR OR 2X BUCK BY OTHERS EXTERIOR NOTES: 1. INTERIOR AND EXTERIOR FINISHES,BYOTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT SY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 #14 WOOD SCREW MQSILL TO BE SET BACKER ROD I• IN A BED OF & APSPEROOVVED APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION BACKER ROD & APPROVED 1/4" MAX. SEALANT_ SHIM SPACE SIGNED.0611412017 MIN MI WINDOWS AND DOORS LLC EMBEDMENT 650 WEST MARKET STREET GRATZ, PA 17030 WOOD FRAMING SERIES 120/130/140 ALUMINUM SLIDING _�*� 0 1 �k' OR 2X BUCK GLASS DOOR - IMPACT BY OTHERS 5/8" MIN 3 TRACK FINLESS INSTALLATION DETAILS r �EDGE DISTANCE DRAWN: DWG NO. REv �X.';�GR10A�' '`� WOOD RRAMINGO TICAL CROSS PK BUCK IN.SSTALLATION �NTS — 04/13/17 OS--86 OF 24 L.ROBERTO LOMAS P.E. LUI9 R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NG 27023 434-08-0609 rllamesPhlomaspe.com FL No.: 62514 REIASIONS 5/3" MIN. RLV DsmpnoN Dare APPROVED EDGE DISTANCE METAL STRUCTURE 1/4" MAX. BY OTHERS I SHIM SPACE BACKER ROD 1/4" MAX. 5/8„ ;:��I INTERIOR & APPROVED SHIM SPACE MIN. SEALANT EDGE DISTANCE 14 SMS OR SELF DRILLING SCREW #14 SMS OR EXTERIOR SELF DRILLING SCREWS INTERIOR METAL EXTERIOR STRUCTURE NOTES: BY OTHERS 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED INACCORDANCE WITH ASTM E2112 #14 SMS OR SELF DRILLING SCREW SILL TO BE SET BACKER ROD l l IN A BED OF & APPROVED APPROVED SEALANT SEALANT JAMB INSTALLATION DETAIL (� METAL STRUCTURE INSTALLATION BACKER ROD U& APPROVED 1/4" MAX SEALANT _�SHIM SPACE SIGNED:0611412017 MI WI NDOWS C DOORS M RKET ST LLC STREET - I IN GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING ; 0 METAL GLASS DOOR - IMPACTS v��k a67 `. STRUCTURE 3 TRACK FINLESS INSTALLATION DETAILS AT t1F vJ BY OTHERS VERTICAL CROSS SECTION EDGE DISTANCE DRAWN: DWG No. REV ARtO A' - METAL STRUCTURE INSTALLATION R.S. 08-03086 — Sc—NTS DATE 04/13/17' SN- 9 OF 24 /111110 L ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE NC27023 FL No.: 62514 434-MO-0609 Abma @lrfdawpe.c m RDISWNS 4 7/16" MIN 1 7/8" MIN. SEPARATION EDGE DISTANCE REY DESM ON aae APPRovm CONCRETE/MASONRY 4 Y e BY OTHERS .: . a..� •,.,Q•.• :'.; ..�' ;• .• . •c , 1 1/4" MIN. 1 1/4" MIN. e .-• ° .. • `e- -e;" EMBEDMENT EMBEDMENT 1/4" MAX. OPTIONAL 1X BUCK ° ° ,.4 SHIM SPACE SEE NOTES 3 — 7 -- SHEET 1 ° 1 7/8" INTERIOR BACKER ROD 1/4" MAX. MIN. & APPROVED SHIM SPACE EDGE SEALANT DISTANCE v• •� .: .. ' e c 1/4" TAPCON , o " — NOTES: EXTERIOR 1.--INTERIOR AND EXTERIOR.FINISHES,BY OTHERS, ' NOT SHOWN FOR CLARITY. 4 7/16" 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE MIN b <' DESIGNED INACCORDANCE WITHASTME2112 SEPARATION INTERIOR ' I EXTERIOR '4 Omp 1/4" TAPCON CONCRETE/MASONRY ° 1/4" TAPCON BY OTHERS BACKER ROD & APPROVED SILL TO BE SET SEALANT a IN A BED OF OPTIONAL 1 X BUCK APPROVED SEALANT SEE NOTES 3-7 JAMB INSTALLATION DETAIL SHEET 1 CONCRETEJMASONRYINSTALLATION BACKER ROD 1/4" MAX. --- SIGNED:APPROVED SHIM SPACE SIGNED:06/14/2017 SEALANT Ml WIN650DOWSW WEST AND KE STREET C_ g�� ��x GRATZ, PA 17030 `ti y�G£N�+ '9Jir OPTIONAL 1X BUCK ' e --� SERIES 120/130/140 ALUMINUM SLIDING 4- TOATle, •.a a. :'e, 1 1/4" MINSEE NOTE 3 — 7 e" " ,'a EMBEDMENTGLASS DOOR — IMPACTSHEET 1 a ° .'- ".• 3 ;14n FINLESS INSTALLATION DETAILS 7� F Q �': •. DRAWN: Dwc No. REV % SlOR1QP` �t��: CONCRETE/MASONRY BY OTHERS 4 7/16" MIN 1 7/8" MIN R.S. 08-0033086 /j�7 ....SEPARATION EDGE DISTANCE 04/13/17 10 OF 24 VERTICAL CROSS SECTION L ROSERIOLOMASP.E. Luis R. Lomas P.E. CONCRETFJMASONRYINSTALLATION 434�-0609 rnomas@Womaspe.win FL No.: 62514 5/8" MIN. RLv OESCRIPIION Date aarRw[o EDGE DISTANCE WOOD FRAMING OR 2X BUCK BY OTHERS 1 3/8" MIN. EMBEDMENT r SHIM+SPACE EMBEDMENT I! 5/8" INTERIOR BACKER ROD 1/4" MAX MIN. EDGE & APPROVED SHIM SPACE DISTANCE SEALANT #14 WOOD SCREW #14 WOOD EXTERIOR SCREW - - - - - -- ---- _ -- _ --- WOOD FRAMING OR 2X-BUCK- BY OTHERS INTERIOR NOTES: XTERIOR 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BYOTHERS TO SE DESIGNED IN ACCORDANCE WITH ASTM E2112 U— con— #14 WOOD SCREW { SILL TO BE SET IN A BED OF APPROVED SEALANT BACKER ROD JAMB INSTALLA TION DETAIL & APPROVED WOOD FR4MINGOR2XBUCKhNSTALLATION BACKER ROD SEALANT & APPROVED SEALANT 1/4" MAX. -- SHIM SPACE SIGNED:0611412017. MI-WINDOWS AND DOORS LLC --- ���t111trfryli - - 1 3 MIN 650 WEST MARKET STREET EMBEDMENT GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING + ,0 WOOD FRAMING GLASS DOOR - IMPACTow It= OR 2X BUCK 5/8" MIN 4 TRACK FINLESS INSTALLATION DETAILS i AT Qf 8Y OTHERS WOOD EFRAMINGORRTICAL 2OBUCK/NS ASS ILLATION ON EDGE DISTANCE DRAWN: owc No, �y d ( 1pa scaLE Date 08 03308s NTS 04/13/17 ll OF 24 L.ROBERTO LOMAS P.E. LU1S R. Lomas P.E. 1432 WOODFORD RD LEMSVILLE,NC27D23 FL No 62514 434-M-0609 4fames@Irfumaspe.mm REVISIONS REV DESCRIPTION DAiE APPROVED 5/8" MIN. EDGE DISTANCE 1/4" MAX. SHIM SPACE METAL STRUCTURE INTERIOR BY OTHERS 5/8" MIL MIN. BACKER ROD 1/4" MAX EDGE DISTANCE & APPROVED SHIM SPACE SEALANT a co 14 SMS OR SELF DRILLING #14 SMS OR EXTERIOR SCREW SELF DRILUNG SCREWS METAL STRUCTURE EXTERIOR INTERIOR BY OTHERS NOTES: 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. a PERIMETER AND JOINT SEALANT BY OTHERS TO BE #14 SMS OR DESIGNED IN ACCORDANCE WITHASTME2112 SELF DRILLING SCREW ' SILL TO BE SET \ IN A BED OF APPROVED SEALANT BACKER ROD JAMB INSTALLATION DETAIL & APPROVED METAL STRUCTURE INSTALLATION SEALANT BACKER ROD & APPROVED ®rul SEALANT 1/4' MAX. SIGNED:06/14/20i7 - — - - _ F SHIM SPACE MI 650DWESSMARDKETOSTORS REET�C- - ```z�,giR11�1��f GRATZ, PA 17030 tD fi•, y SERIES 120/130/140 ALUMINUM SLIDING 0 J GLASS DOOR - IMPACT METAL J 4 TRACK FINLESS INSTALLATION DETAILS 6 +.t-:t�' TAT a STRUCTURE BY OTHERS 5 8" MIN. DRAWN: I DWG No. REv 'ifi YQii1V. �s VERTICAL CROSS I EDGE DISTANCE R.S. E 08-03086 - �'j/s ONA� M S NTS �� 04/13/17 03 12 OF 24 t L ROBERTO LOMAS P.E Luis R. Lomas P.E. 14V WOODFORD RD LEWISVILLE,NC 270M FL No.: 62514 434-68S-0609 l l0aQS0lrl0MwPe.wm RENTOW 4 7/16" MIN 1 7/8" MIN, CONCRETE/MASONRY SEPARATION EDGE DISTANCE� REV oEscR7RON DATE AppRoym BY OTHERS ..a a • 1 4" MAX a•. '.: c..•"'. �`. v 1 1/4" MIN, SHIM SPACE ' ° Q :'� i 1 1/4" MIN. EMBEDMENT OPTIONAL 1X BUCK ; :� . �4' ;4•` <' EMBEDMENT n SEE NOTES 3 - 7 r a. .. " e•`'. •• SHEET 1 1 7/8" •' INTERIOR MIN. EDGE DISTANCE °• .: BACKER ROD 1/4" MAX, ° & APPROVED SHIM SPACE v SEALANT • a 1/4" TAPCON •� EXTERIOR 4 7/16" MIN e SEPARATION NOTES: -- 1, INTERIOR ANDEXTERIOR FINISHES.BYOTHERS, NOT SHOWN FOR CLARITY. ° 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE ° EXTERIOR DESIGNED IN ACCORDANCE WITH ASTM LEI 12 INTERIOR 1/4" TAPCON I Arf—umv--i rf 0 1/4" TAPCON CONCRETE/MASONRY rr BY OTHERS ° BACKER ROD SILL TO BE SET IN A BED OF & APPROVED APPROVED SEALANT OPTIONAL 1X BUCK SEALANT SEE NOTE 3 - 7 SHEET 1 JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION BACKER ROD 1/4" MAX. SIGNED:0611412017 &_APPROVED SHIM SPACE 'SEALANT— _ -- - _ OPTIONAL 1X BUCK M' -WINDOWS 650 ST M RKETD STREET PLC ' - ��i* g P. to ,�/�� SEE NOTE 3 - 7 v �(r`ENS SHEET 1 �l GRATZ, PA 17030 •. <B a a, ",•q : a '" SERIES 120/130/140 ALUMINUM SLIDING ��`* �p Ih"1 1/4" MIN GLASS DOOR - IMPACT w .yam' <v - •. 4 . • < -.a te'• • f3v1BEDMENT 4 TRACK FINLESS INSTALLATION DETAILS Q TAj 4 • :•• •° .•.♦,' a .. DRAWN: 05YG N0. REV •':�iS3RSas` �t 8 4 7/16" MIN o1 7/8" MIN . Srru 08-s033086 F CONCRETE/MASONRY NITS nA� 04/13/17 13 OF 24 BY OTHERS SEPARATION EDGE DISTANCE VERTICAL CROSS SECTION L ROBERTOLOMASP,E. Luis R. Lomas P.E. CONCRET&MASONRYINSTALLAPON /64ro 8-06 9D doL�Af0maSLLE� -comma FL No.: 62514 aspe.eom i 5/8" MIN. REHsor� EDGE DISTANCE REV DEScmMON MlE APPROVED WOOD FRAMING OR 2X BUCK BY OTHERS 1 3/8" MIN. EMBEDMENT 1 3/8" MIN. 1/4" MAX. EMBEDMENT SHIM SPACE BACKER ROD 1/4" MAX & APPROVED SHIM SPACE INTERIOR SEALANT 5/8" MIN. EDGE #14 WOOD SCREW DISTANCE #14 WOOD EXTERIOR SCREW WOOD FRAMING OR 2X BUCK INTERIOR BY OTHERS IOR NOTES: EXTER 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY 2. PERIMETER AND JOINTSEALANTBYOT14ERSTOSE BACKER ROD A E h DESIGNED INACCOROANCE WITH ASTME2112 & APPROVED JAMB INSTALLATION DETAIL SEALANT WOOD FRAMING OR 2X BUCK INSTALLATION #14 WOOD SCREW SILL TO BE SET IN A BED OF APPROVED SEALANT BACKER ROD 1/4" MAX & APPROVED SHIM SPACE SIGNED:06/1412017 MI WINDOWS AND DOORS LLC �1���tittttrrr/ - - 1 3/8" MIN 650 WEST MARKET STREET EMBEDMENT GRATZ, PA 17030L"CNgd+y SERIES 120/130/140 ALUMINUM SLIDING *• 0 � WOOD f(t4MING GLASS DOOR — IMPACT v OR 2X BUCK 5/8" MIN 2 TRACK FLANGE INSTALLATION DETAILS XIGS�r TAT .. BY OTHERS VERTICAL CROSS SECTION EDGE DISTANCE DRAWN: DWG NO, REV WOOD FRAMING ORZX BUCK INSTALL4770M R.S. 08-030$6 — SCAE NTS I DA'E 04/13/17 51�14 OF 24 L.ROSERTO LOMAS P.E Luis R. Lomas P.E. r432 WooDFORD RO tEW SWU E,NC270M FL No.: 62514 434-088-0%9 ftffm@kbmesm.cmn II REVMONS 5/8" MIN. REV DESORL"ON DATE APPROVED EDGE DISTANCE METAL STRUCTURE 1/4" MAX. BY OTHERS I SHIM SPACE BACKER ROD 1/4" MAX. 5/8" INTERIOR & APPROVED SHIM SPACE MIN. SEALANT EDGE DISTANCE 114 SMS OR SELF DRILLING SCREW #14 SMS OR EXTERIOR SELF DRILLING -SCREWS INTERIOR EXTERIOR METAL NOTES: STRUCTURE 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, BY OTHERS NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE BACKER ROD DESIGNED IN ACCORDANCE W17HASTM E2112 & APPROVED SEALANT #14 SMS OR JAMB INSTALLATION DETAIL SELF DRILLING METAL STRUCTURE INSTALLATION SCREW SILL TO BE SET IN A BED OF APPROVED SEALANT BACKER ROD & APPROVED MAX 4 SEALANT 1 sHIM"SPACE SIGNED:06/14/2017 MI WINDOWS ANDVt 650W MARKET STREET --- GRATZ, PA 17030 � SERIES 120/130/140 ALUMINUM SLIDING :*'' 0 may: METAL GLASS DOOR - IMPACT =tea= STRUCTURE 2 TRACK FLANGE INSTALLATION DETAILS yp. S8A7 OE ;�t4v` BY OTHERS SS SECTION EDGE DISTANCE DRAWN: DWG NO. REV �fs ORt�,A�G`C`�4 METAL STRUCTUCAL RE INSTALLATION 6caE �� 08 033086 NTS 04/13/17 15 OF 24 L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NO 27023 FL No.: 62514 434-688-0609 d/amag@lAamwpe.com 2 3/16" MIN 1 7/8" MIN. REVISIONS SEPARATION EDGE DISTANCE r REV DESCRIPnON DATE APPROVED CONCRETE/MASONRY a'•a"... BY OTHERS mod• 1 1/4" MIN. 1 1/4" MIN. OPTIONAL 1X BUCK r', !, EMBEDMENT EMBEDMENT 1/4" MAX. SEE NOTES 3 — 7 —--T SHIM SPACE SHEET 1 BACKER ROD 1/4' MAX. 1 7/8" INTERIOR & APPROVED MIN. c Q' SEALANT SHIM SPACE EDGE " DISTANCE 3,- •a.. .. 9 1/4" TAPCON 2 3/16' MIN SEPARATION EXTERIOR 1/4" TAPCON ° INTERIOR CONCRETE/MASONRY 0'° 8Y OTHERS EXTERIOR OPTIONAL 1X BUCK BACKER ROD SEE NOTE 3 — 7 & APPROVED SHEET 1 SEALANT JAMB INSTALLATION DETAIL 1/4" TAPCON CONCRETEIMASONRYINSTALLATION SILL TO BE SET NOTES: IN A BED OF APPROVED SEALANT 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETERAND✓OINTSEALANT BYOTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E21 f2 BACKER ROD 1/4" MAX. SIGNED:O6/14/2017 ---- --- ------- ---- SEALANT SHIM SPACE & APPROVED MI WINDOWS AND DOORS LLCWEST OPTIONAL 1X BUCK 650 RATZ,MET PAK17030REET E IV �°+ SEE NOTESHEET 1 . '� % ` SERIES 120/130/140 ALUMINUM SLIDING �1k•' 1 1/4" MIN 8 . GLASS DOOR — IMPACT a :��3/ � EMBEDMENT2 TRACK FLANGE INSTALLATION DETAILSTATO OF wCONCRETE/MASONRY , DRAVIN: t40 •BY OTHERS R.S. 08-03Q86 �A` �\Ni�1 7/8" MIN WAE NTS DATE 04/13/17 SHEET 16 OF 24 ���1t{.1L11Sl�k SEPARATION EDGE DISTANCE VERTICAL CROSS SECTION L.ROBERTO LOMAS AE Luis R. Lomas P.E. CONCRETEIMASONRY INSTALLATION f42 WOODFORO RD LEWISWUE,NC27o23 49"w- g rlomas@1Aomaspe.com FL No.: 62514 REVISIONS 5/8" MIN. REv DF5CRIPn0N DATE I APPROM EDGE DISTANCE WOOD FRAMING OR 2X BUCK BY OTHERS 1 3/8" MIN. EMBEDMENT 1 3/8" MIN. 1/4" MAX. EMBEDMENT— r SHIM SPACE BACKER ROD 1/4" MAX. 5/18u I INTERIOR & APPROVED SHIM SPACE MIN. SEALANT EDGE DISTANCE #14 WOOD SCREW M= ch #14 WOOD EXTERIOR SCREW al- t WOOD FRAMING OR 2X BUCK INTERIOR BY OTHERS E ERIOR NOTES: 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 #14 WOOD SCREW BACKER ROD SILL TO BE SET & APPROVED JAMB INSTALLATION DETAIL I I IN A BED OF SEALANT APPROVED SEALANT WOOD FRAMING OR2X BUCK INSTALLATION BACKER ROD 1/4" MAX & APPROVED SHIM SPACE SEALANT SIGNED:0611412017 30 FSERIES DOWS AND DOORS LLC ��iiillu(flri��f - - - EMBEDMENT WEST TZ,MARPA KET TT0STREET /130/140 ALUMINUM SLIDING *• 0WOOD FRAMING LASS DOOR - IMPACT � OR 2X BUCK 3 TRACK FLANGE INSTALLATION DETAILS -..�"- TAT 5 8" MIN r0 BY OTHERS WOODERTICAL CRSS FRAM/NGOR2XOBUCKlNST4LLAnTION EDGE DISTANCE �� owc No. 08- 86 Re/ �%`j►�%� A` 1�``` NTS 04/13/17 17 OF 24 L.ROBERTO LOMAS RE LUIS R. Lomas P.E. 1432 WOODFORO RD LEMSVILLE,NC27023 FL No.: 62514 434-M-0609 11lomas@6lamaspe.cam REW 90NS 5/8" MIN. REV DESCRIPNON DATE APPROVED EDGE DISTANCE METAL STRUCTURE 1/4" MAX. BY OTHERS SHIM SPACE BACKER ROD 1/4" MAX. � INTERIOR & APPROVED SHIM SPACE 5/8" MIN. SEALANT EDGE DISTANCE 414 SMS OR SELF DRILLING SCREW #14 SMS OR EXTERIOR SELF DRILLING - - -SCREWS - - INTERIOR METAL EXTERIOR STRUCTURE NOTES: BY OTHERS 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE ®rw� mv� DESIGNED IN ACCORDANCE WITH ASTM E2112 #14 SMS OR SELF DRILLING SCREW BACKER ROD SILL TO BE SET & APPROVED SI 1 I BED OF SEALANT APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION BACKER ROD & APPROVED 1 4 MAX. SEALANT / " SIGNED:0611412017 _ F SHIM SPACE MI WINDOWS MARCKET DOORS - `��1\A"tiltl ItLJ�� - 'yr ---_-- GRATZ, PA 17030 `v ti�6N�+ •E{+ SERIES 120/130/140 ALUMINUM SLIDING >A:• 0 9k METAL GLASS DOOR - IMPACT �CZ, STRUCTURE 3 TRACK FLANGE INSTALLATION DETAILS x • . TAT OF •ty�. BY OTHERS 5/8" MIN. VERTICAL CROSS SECTION EDGE DISTANCE DRAwN Dwc No. "� •�d�fi•.+(0R1pF• � R.S. OS-03086 � �` METAL STRUCTURE INSTALLATION �';,Ill�701V 111 GME NTS DAIS 04/13/17 SHEEP 18 OF 24 L.ROBERTO LOMAS P.E Luis R. Lomas P.E. 14V WOODFORD RD LEWISVILLE AIC 27023 FL NO.: 62$14 434-668-0609 ftn%3S@trl0ma5pe=M ROIISIONS - 4 7/16" MIN 1 7/8" MIN SEPARATION EDGE DISTANCE REV DPnon oAh CONCRETE/MASONRY a°• ` a BY OTHERS '. a..° n,• :'._' .. " • °• c ; "•° 1 1/4" MIN. i 1/4" MIN. •; aa. . EMBEDMENT EMBEDMENT 1/4" MAX. OPTIONAL IX BUCK a•, SHIM SPACE SEE NOTES 3 7 'r SHEEP 1 �1 BACKER ROD 1/4" MAX. 1 MIN INTERIOR & APPROVED SHIM SPACE EDGE SEALANT DISTANCE >• -. .. 1/4" TAPCON NOTES: . EXTERIOR 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, o' NOT SHOWN FOR CLARITY. -4 7/16" , - 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE MIN DESIGNED IN A CCORDANCE WITH AS TM E2112 SEPARATION INTERIOR ° EXTERIOR 1/4" TAPCON o 1/4" TAPCON CONCRETE/MASONRY BY OTHERS BACKER ROD SILL TO BE SET OPTIONAL 1X BUCK & APPROVED IN A BED OF SEE NOTE 3 — 1 SEALANT APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETFIMASONRY INSTALLATION BACKER ROD 1/4' MAX. SIGNED:0611412017 & APPROVED SHIM SPACE — — ---SEALANT--- MI ssoDWWS EST AND RDEDOORS LLC ` ll tg Rft.Liy' GRATZ, PA 17030 =�i:'v�t+��S OPTIONAL 1 X BUCK SEE NOTE 3 — 7 ... a " " a `:' SERIES 120/130/140 ALUMINUM SLIDING ATOATle. i a. 1 1/4" MIN SHEET 1EMBEDMENT GLASS DOOR — IMPACT 3 TRACK FLANGE INSTALLATION DETAILS . F, a• ° °.° a 4°. ... '. : _ - -- ° DRAWN: DWG N0. REV /' '• 1d. S'.'+ R.S. 08-03086 q�` ��. CONCRETE/MASONRY 4 7/16" MIN 1 7/8" MIN sOUE NTS Q1TE 04/13/17 snFFr 19 OF 24 BY OTHERS SEPARATION EDGE DISTANCE L ROBERTO COMAS P.E. Luis R. Lomas P.E. VERTICAL CROSS SECTION 1432WOODFORDRDLEWISVILLE,IVC27023 FL No.: 62514 CONCRETFJMASONRYINSTALLATION 4N-668-0609 dlomes[vMomaspe.wm RE19510N5 5/8" MIN. REV sEscemnON DATE I AMMM EDGE DISTANCE WOOD FRAMING OR 2X BUCK 1 1 3/B" MIN. 1/4" MAX. BY OTHERS 1 3/8" IN. EMBEDMENT SHIM SPACE EMBEOM T INTERIOR 5/8" MIN. BACKER ROD 1/4" MAX. EDGE & APPROVED SHIM SPACE DISTANCE SEALANT #14 WOOD SCREW #14 WOOD EXTERIOR SCREW - - WOOD FRAMING OR 2X BUCK BY OTHERS INTERIOR NOTES: EXTERIOR I 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 row, #14 WOOD SCREW SILL TO BE SET I IN A BED OF APPROVED SEALANT BACKER ROD JAMB INSTALLATION DETAIL & APPROVED WOOD FRAMING OR 2X BUCK INSTALLAT70N BACKER ROD SEALANT & APPROVED SEALANT 1 4 MAX. SHIM SPACE SIGNED:0611412017 MI WINDOWS AND DOORS LLC 1 3/8" MIN 650 WEST MARKET STREET EMBEDMENT GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING *�'. 0 �k= GLASS DOOR - IMPACT 4 TRACK FLANGE INSTALLATION DETAILS ! Q AT �F WOOD OR FRAMING CK VERTICAL CROSS SECTION EDGE DISTANCE DRnwN: ows NO. BY OTHERS _ WOOD FRAMING OR 2X BUCK INSTALLATION sou E NTS �� 04/13/17 08_ �20 OF 24 s16 IA` L ROaERTO LOMAS RE Luis R. Lomas P.E. 1432 WOODFORD RD LEMSVILLF-NO 27023 FL No.: 62514 434-688-0609 Abmas@ftmaspe.aom i REMONS 5/8' MIN. DESCFi P1I0N DA>E EDGE DISTANCE 1/4" MAX. METAL I SHIM SPACE STRUCTURE BY OTHERS ^� 5/8' INTERlOA 1/4' MAX MIN. BACKER ROD EDGE & APPROVED SHIM SPACE DISTANCE SEALANT J #14 SMS OR FIE SELF DRILLING #14 SMS OR EXTERIOR SCREW SELF DRILLING SCREWS METAL STRUCTURE INTERIOR BY OTHERS EXTERIOR NOTES: 1, INTERIORAND EXTERIOR r-w5HES,BYOTHERS, ®r NOT SHOWN FOR CLARITY. 2 PERIMETER AND JOINT SEALANT BYOTHERS TO BE #14 SMS OR DESIGNED IN ACCORDANCE WITH ASTM E2112 SELF DRILLING SCREW SILL TO BE SET IN A BED OF APPROVED SEALANT BACKER ROD JAMB INSTALLATION DETAIL BACKER ROD & APPROVED METAL STRUCTURE INSTALLATION SEALANT & APPROVED SEALANT 1/4" MAX. SIGNED:0611412017 An SHIM SPACE MI WINDOWS AND DOORS LLC—------ �Xti,,`a 650 WEST MARKET STREET GRATZ, PA 17030 �'` G S d►,ter. SERIES 120/130/140 ALUMINUM SLIDING *� 0 9t� GLASS DOOR — IMPACT XOy METAL 4 TRACK FLANGE INSTALLATION DETAILS '70. AT STRUCTURE iG BY OTHERS 5/8" MIN. DRAWN: �� �. ECTION EDGE DISTANCE owc NO' i +• DR1� METAL ISTRUCTURE INSSS TALLATION SCALE �� 04/13/17 �308621 OF 24 OS-0 — IQ�a NTS L.ROBERTOLOMIAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC27DM FL No as i 4 434-BBB-0609 A/omas@Idomaspe.cam REWS(ONS it 4 7/16" MIN 1 7/8' MIN. CONCRETE/MASONRY SEPARATION EDGE DISTANCE r REV DE aWMDN DatE APPROVED BY OTHERS a . •' '• .6.. .. a.. '.. .�.• e.. v 1 1/4' MIN. 1/4" MAX. c . < 1 1/4" MIN. EMBEDMENT SHIM SPACE • .'. Q°• •: EMBEDMENT _ n C -+• • + u •4' -•O - OPTIONAL 1X BUCK SEE NOTES 3 - 7 1 7/8" !' INTERIOR SHEET 1 _� MIN. a EDGE BACKER ROD DISTANCE n .: 1/4" MAX. ° & APPROVED SHIM SPACE v SEALANT 1/4- TAPCON Ov EXTERIOR 4 7/16" MIN v ' SEPARATION NOTES: - o 1. INTERIOR AND EXTERIOR FINISHES,BYOTHERS, NOT SHOWN FOR CLARITY. :a 2. PERIMETER ANDJOINT SEALANT BYOTHERS TO BE ° DESIGNED IN ACCORDANCE WITH ASTM E2112 . INTERIOR EXTERIOR 1/4" TAPCON A CONCRETE/MASONRY 1/4" TAPCON BY OTHERS f SILL TO BE SET OPTIONAL 1X BUCK BACKER ROD IN A BED OF SEE NOTE 3 - 7 & APPROVED APPROVED SEALANT SHEET 1 SEALANT JAMB INSTALLATION DETAIL CONCRETEIMASONRY INSTALLATION BACKER ROD 1/4" MAX. --- _&_APP_ROVED N SHIM SPACE SIGNED:06/14/2017 SEALANT MI 650DWESS MARKET DOORS RJEE ``Jg — GRATZ, PA 17030 OPTIONAL 1X BUCK .'� SEE NOTE 3 - 7 , "B ..,, - e SERIES 120/130/140 ALUMINU SHEET 1 a` "' 1 1/4" MIN e e EMBEDMENT GLASS DOOR - IMPAC. Q4 TRACK FLANGE INSTALLATIOice;: TATORAWN: DWG N0. /Z13086 � ..i+CONCRETE/MASONRY OTHERS 4 7/16" MIN 1 7/8" MINNTS �� 04/13/17 08 sOEsr �f��SEPARATION EDGE DISTANCEVERTICAL CROSS SECTION L ROBERD LEWIS SP.ELuis R. Lomas P.E. CONCRETEIMASONRYINSTALLATION f�W-688.0 0.9 woman Ioft a eNG�SpeFL No.: 62514 REV6lONS 1 MIN. REV DEsowFnDN DATE:DATE:1 3/8" MIN, APFROM EMBED BED EMBEDMENT MENT NOTES, WOOD FRAMING WOOD FRAMING 1.INTERIOR AND EXTERIOR FINISHES,BYOTHERS. #14 WOOD OR T BUCK #14 WOOD SCREW OR 2X BUCK NOTSHOWN FOR CLARITY. SCREW BY OTHERS BY OTHERS 2.PERIMETER AND JOINTSEALANTBY OTHERS ToBE DESIGNED INACCORDANCE WITH ASTM E2112 5/8" MIN. 5/8" MIN. EDGE DISTANCE HOOK STRIP EDGF DISTANCE HOOK STRIP INTERIOR INTERIOR PANEL INTERLOCK PANEL INTERLOCK EXTERIOR EXTERIOR HOOK STRIP M 2533 INSTALLATION HOOK STRIP(M-2534)INSTALLATION 2X BUCKANOOD FRAMING 2X BUCKANOOD FRAMING i METAL STRUCTURE METAL STRUCTURE BY OTHERS BY OTHERS I #14 SELF DRILLING #14 SELF DRILLING SCREW SCREW fflmmmno � � 5/8" MIN. 5E D MIN. EDGEDISTANCE EDGE HOOK STRIP HOOK STRIP SIGNED:O6n4/2017 1NTEAlOR INTERIOR MI WINDOWS AND DOORS LLC iti1�1�►11/, 650 WEST MARKET STREETLd - PANEL INTERLOCK ♦ .••• g1 /i PANEL INTERLOCK GRATZ, PA 17030 ` J 4tpFIV '¢�,� SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — IMPACT HOOK INSTALLATION DETAILS •C �, TATkCI: EXTERIOR EXTERIOR DRAWN: DWG NO. REY '►�j.`�. pR�dP. R.S. 1 08-03086 HOOK STRIP M 2533 INSTALLATION HOOK STRIP(M-2534)INSTALLATION se"NTS D"TE 04/13/17 1 SHEET 23 OF 24 7/yIIHAtl.1`i,�t METAL STRUCTURE METAL STRUCTURE L.ROBERTOLOMASRE Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE NC 27023 41"66-6606 gfofflas@IrfOmaspe.com FL No.: 62514 REVISIONS i 1✓£y DESCRIPNON 647E APPROVED 1 1/4" MIN. 1 1/4" MIN. EMBEDMENT EMBEDMENT 1X BUCK BY OTHERS, 1X BUCK BY OTHERS, 1X BUCK TO BE n 1X BUCK TO BE ° PROPERLY SECURED n PROPERLY SECURED MASONRY/CONCRETE MASONRY/CONCRETE 1/4" TAPCON BY OTHERS 1/4" TAPCON BY OTHERS 1 3/4" MIN. HOOK STRIP HOOK STRIP p EDGEDISTANCE MIN. EDGE DISTANCE ° 3/4" INTERIOR INTERIOR 3/4" PANEL INTERLOCK PANEL INTERLOCK 3 1/2" EXTERIOR EXTERIOR HOOK STRIP(M-2533)INSTALLATION HOOK STRIP(M-2534)INSTALLATION MASONRY/CONCRETE MASONAYXONCRETE 3 1/2"SILL EXTENDER 2 518"SILL EXTENDER 1 1/16" ALUMINUM 6063-T5.062'THICK ALUMINUM 6063-T5.062"THICK 3/16" TEMP 3/16" ANN 100" HP PVB BY EASTMAN EXTERIOR 3/16" ANN STAINLESS STEEL BOX SPACER INTERIOR SIGNED:0611412017 ALUMINUM MI WINDOWS AND DOORS LLC ++++11U61 - GLAZING BEAD 650 WEST MARKET STREET \��s .tor7 SILICONE SEALANT GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING 3/4" BITE GLASS DOOR - IMPACT GLAZING AND SILL RISER DETAILS °9 DRAWN. DWG NO. REV 1� �•'Az r 1 GLAZING DETAIL SCALE NTS DAB 04/13/17 08-03086 s0324 OF 24 ss�0NAi I? L ROBERTO LOMAS RE Luis R. Lomas P.E. 1432 WOODFORD RD LEMSVILLE,NC 27023 FL No.: 62514 434-688-0609 d10m8S@ldomaVaC0m