Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS
DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE-LINE DIAGRAM PV-4 SAFETY LABELS PV-5.1 ATTACHMENT PLAN 5.1 PV-5.2 ATTACHMENT PLAN 5.2 PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN APPENDIXMODULE DATASHEET DISCONNECT DATASHEET INVERTER DATASHEET MOUNTING SYSTEM DATASHEET MOUNTING SYSTEM ENGINEERING LETTER UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY ADDRESS 5111 BIRCH DR, FORT PIERCE, FL 34982 US ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) UTILITY COMPANY FLORIDA POWER & LIGHT CO ELECTRICAL CODE 2014 NEC (NFPA 70) FIRE CODE 2015 NFPA 1 OTHER BUILDING CODES 2017 FL BUILDING CODE CONTRACTOR INFORMATION COMPANY EFFICIENT HOME SERVICES ADDRESS 9416 INTERNATIONAL CT ST PETER, PALM BAY, FL 33716 PHONE NUMBER (844) 505-8144 CONTRACTOR SIGNATURE SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A PHOTOVOLTAIC POWER SYSTEM. SOLAR PANELS WILL BE RACKED USING A PREENGINEERED RACKING SYSTEM. THE RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO BATTERY STORAGE DC RATING OF SYSTEM 11.52KW AC RATING OF SYSTEM 8.64KW AC OUTPUT CURRENT 36.0A INVERTER(S)36 X ENPHASE IQ7-60-2-US MODULE Q-CELLS Q.PEAK DUO BLK-G5 320 ARRAY WIRING (2) BRANCH OF 16 IQ7-60-2-US MICROINVERTERS (1) BRANCH OF 4 IQ7-60-2-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF CONNECTION NEW SUPPLY SIDE AC CONNECTION PER NEC 705.12(A) UTILITY SERVICE 120/240V 1Φ SITE DETAILS ASHRAE EXTREME LOW 0°C (32°F) ASHRAE 2% HIGH 33°C (91°F) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORT (KVRB) WIND SPEED 160 MPH (ASCE7-10) RISK CATEGORY II WIND EXPOSURE CATEGORY B P-147695 GRID-TIED SOLAR POWER SYSTEM5111 BIRCH DRFORT PIERCE, FL 34982PROJECT SUMMARY DOC ID:147695-182295-1 DATE:10/21/20 CREATOR: REVIEWER: REVISIONS PV-1 I REYES M RUIZ DONATE PE# 88991 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENTVERSION OF THE FLORIDA BUILDING CODE. This item has been signed and sealed byReyes Manuel Ruiz Donate, 88991PE on 10/21/2020using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 3 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. ROADWAY (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 4:12 (18°) SLOPED ROOF, 19 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 270° AZIMUTH (N) TRANSITION BOX (JB2), OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN PVC-40 CONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE (N) AC COMBINER (C1), OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN PVC-40 CONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE (E) MAIN SERVICE PANEL (MSP), OUTDOOR (E) UTILITY METER, OUTDOOR (N) TRANSITION BOX (JB1), OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN PVC-40 CONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE (N) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER (SW1), OUTDOOR (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 4:12 (18°) SLOPED ROOF, 17 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 180° AZIMUTH P-147695 GRID-TIED SOLAR POWER SYSTEM5111 BIRCH DRFORT PIERCE, FL 34982SITE PLAN DOC ID:147695-182295-1 DATE:10/21/20 CREATOR: REVIEWER: REVISIONS PV-2 PV MODULE MICRO- INVERTER 4 IN BRANCH 16 IN BRANCH 16 IN BRANCH PM1-36 320W 1 2 3 4 5 6 JUNCTION BOXES JB1-2 31 2 AC COMBINER CB2 20A CB1 20A 4 CB3 20A C1 AC GEC LOADS KWHRKWHR PV SYSTEM DISCONNECT UTILITY METER 5 (200A MSP W/200A MCB) SW1 60A F1-2 45A 240/120V 1ɸ, 3W 7 8 MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-36 36 Q-CELLS Q.PEAK DUO BLK-G5 320 320W 297W 9.94A 9.47A 40.6V 33.8V -0.114V/°C (-0.28%/°C)20A INVERTERS REF.QTY.MAKE AND MODEL AC VOLTAGE GROUND MAX OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-36 36 ENPHASE IQ7-60-2-US 240V UNGROUNDED --240W 1.0A 15.0A 48V 97.0% PASS-THRU BOXES AND COMBINERS REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE JB2 1 GENERIC GEN-AWB-TB-2-4X OR EQUIV.30A 240VAC / 600VDC JB1 1 GENERIC GEN-AWB-TB-4-4X OR EQUIV.30A 240VAC / 600VDC C1 1 ENPHASE IQ COMBINER+ OR EQUIV.64A 240VAC DISCONNECTS REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 EATON DG222NRB OR EQUIV.60A 240VAC OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE CB1-2 2 20A 240VAC CB3 1 20A 240VAC F1-2 2 45A 240VAC SYSTEM SUMMARY BRANCH 1 BRANCH 2 BRANCH 3 INVERTERS PER BRANCH 16 16 4 MAX AC CURRENT 16A 16A 4A MAX AC OUTPUT 3,840W 3,840W 960W ARRAY STC POWER 11,520W ARRAY PTC POWER 10,692W MAX AC CURRENT 36A MAX AC POWER OUTPUT 8,640W DERATED AC POWER OUTPUT 8,640W NOTES THE DC AND AC CONNECTORS OF THE ENPHASE IQ7-60-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(A). MATING CONNECTORS SHALL COMPLY WITH NEC 690.17(E). 1 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS), AS PER NEC 690.12.2 MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL3003 AND UL 9703. THE CABLE'S DOUBLE INSULATED RATING REQUIRES NO NEUTRAL OR GROUNDED CONDUCTOR. 3 UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLOR-CODED AS FOLLOWS. DC POSITIVE SHALL BE RED (OR MARKED RED) AND DC NEGATIVE SHALL BE BLACK (OR MARKED BLACK) 4 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45(A). THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47 AND NEC 250.169. THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO NEC 250.166 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 5 MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 43.4V AT 0°C (0°C - 25°C) X -0.114V/C + 40.56V = 43.4V).6 PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER. DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 230.72. 7 POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT, AT A LOCALLY-APPROVED CONNECTION POINT, USING LOCALLY-APPROVED METHODS AND HARDWARE, IN COMPLIANCE WITH NEC 705.12(A). 8 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT / CABLE OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING 1 1 12 AWG THWN-2, COPPER 0.5" DIA. PVC-40 4 20A 12 AWG THWN-2, COPPER 0.76 (55°C)0.8 16A 20A 30A 18.24A 90°C 30A 2 1 12 AWG THWN-2, COPPER 0.5" DIA. PVC-40 4 20A 12 AWG THWN-2, COPPER 0.76 (55°C)0.8 16A 20A 30A 18.24A 90°C 30A 3 1 12 AWG THWN-2, COPPER 0.5" DIA. PVC-40 2 20A 12 AWG THWN-2, COPPER 0.76 (55°C)1.0 4A 5A 30A 22.8A 90°C 30A 4 1 6 AWG THWN-2, COPPER 0.75" DIA. PVC-40 2 N/A 8 AWG THWN-2, COPPER 0.76 (55°C)1.0 36A 45A 75A 57A 75°C 65A 5 1 6 AWG THWN-2, COPPER 0.75" DIA. PVC-40 2 45A X 2 N/A 0.96 (33°C)1.0 36A 45A 75A 72A 75°C 65A REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE:GRID-TIED SOLAR POWER SYSTEMFORT PIERCE, FL 349825111 BIRCH DRPV-3 P-147695 10/21/20 SDT 147695 SINGLE-LINE DIAGRAM 1 PV-3 SINGLE-LINE DIAGRAM NTS GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE 5 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 6 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 7 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 3 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 4 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). SW1 - DISCONNECT (EATON DG222NRB ) MSP - MAIN SERVICE PANEL EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (SW1) ! WARNING ! ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC 690.17(E) AC SOLAR DISCONNECT (SW1) PHOTOVOLTAIC AC DISCONNECT NEC 690.13(B) AC DISCONNECT (SW1) MAXIMUM AC OPERATING CURRENT: 36.0A MAXIMUM AC OPERATING VOLTAGE: 240V NEC 690.54 SEE NOTE NO. 4 (SW1) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN NEC 690.12 AND NEC 690.56(C) ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (SW1, MSP) ! WARNING ! DUAL POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM. NEC 705.12(D)(3) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC 110.21(B). 3 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). 4 LABEL(S) WITH MARKING, "PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN," SHALL BE LOCATED AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT THE LABEL SHALL HAVE 3/8” TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND P-147695 GRID-TIED SOLAR POWER SYSTEM5111 BIRCH DRFORT PIERCE, FL 34982SAFETY LABELS DOC ID:147695-182295-1 DATE:10/21/20 CREATOR: REVIEWER: REVISIONS PV-4 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 4/12 (18.4°) MEAN ROOF HEIGHT 13FT DECK SHEATHING 15/32" OSB CONSTRUCTION RAFTERS (2X4'S), 24IN OC MODULE MECHANICAL PROPERTIES MODEL Q-CELLS Q.PEAK DUO BLK-G5 320 DIMENSIONS (AREA)66.3IN X 39.4IN X 1.3IN (18.1 SQ FT) WEIGHT 41.2LB MOUNTING SYSTEM PROPERTIES RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL ANCHOR MODEL QUICK MOUNT PV QMLM (FLASHED), 1.0IN AIR GAP FASTENING METHOD 3.5 INCH EMBEDMENT INTO RAFTERS WITH (1) 5/16IN DIA. FASTENER MAX. ALLOW. RAIL SPAN 72.0IN (ZONE 1) 48.0IN (ZONE 2) 24.0IN (ZONE 3) MAX. MOUNT SPACING 72.0IN (ZONE 1) 48.0IN (ZONE 2) 24.0IN (ZONE 3) MAX. ALLOW. CANTILEVER 23.8IN (ZONE 1) 15.8IN (ZONE 2) 7.9IN (ZONE 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 17 41.2 700.8 MICROINVERTERS 17 1.1 18.4 LINEAR FEET OF RAIL 114 FT 0.5 57.2 ANCHORS 33 1.0 33.7 MISC. HARDWARE 14.3 14.3 TOTAL ARRAY WEIGHT 824.4 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 17 18.1 307.7 POINT LOAD (824.4 LBS / 33 ATTACHMENTS)25.0 LBS DIST. LOAD (824.4 LBS / 307.7 SQFT)2.68 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 5.2 FT = MAX(MIN(0.4 * 13.0 FT, 0.1 * 59.5 FT), 0.04 * 59.5 FT, 3 FT) P-147695 GRID-TIED SOLAR POWER SYSTEM5111 BIRCH DRFORT PIERCE, FL 34982ATTACHMENT PLAN DOC ID:147695-182295-1 DATE:10/21/20 CREATOR: REVIEWER: REVISIONS PV-5.1 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 4/12 (18.4°) MEAN ROOF HEIGHT 13FT DECK SHEATHING 15/32" OSB CONSTRUCTION RAFTERS (2X4'S), 24IN OC MODULE MECHANICAL PROPERTIES MODEL Q-CELLS Q.PEAK DUO BLK-G5 320 DIMENSIONS (AREA)66.3IN X 39.4IN X 1.3IN (18.1 SQ FT) WEIGHT 41.2LB MOUNTING SYSTEM PROPERTIES RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL ANCHOR MODEL QUICK MOUNT PV QMLM (FLASHED), 1.0IN AIR GAP FASTENING METHOD 3.5 INCH EMBEDMENT INTO RAFTERS WITH (1) 5/16IN DIA. FASTENER MAX. ALLOW. RAIL SPAN 72.0IN (ZONE 1) 48.0IN (ZONE 2) 24.0IN (ZONE 3) MAX. MOUNT SPACING 72.0IN (ZONE 1) 48.0IN (ZONE 2) 24.0IN (ZONE 3) MAX. ALLOW. CANTILEVER 23.8IN (ZONE 1) 15.8IN (ZONE 2) 7.9IN (ZONE 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 19 41.2 783.3 MICROINVERTERS 19 1.1 20.5 LINEAR FEET OF RAIL 129 FT 0.5 64.7 ANCHORS 40 1.0 40.8 MISC. HARDWARE 16.8 16.8 TOTAL ARRAY WEIGHT 926.2 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 19 18.1 343.9 POINT LOAD (926.2 LBS / 40 ATTACHMENTS)23.2 LBS DIST. LOAD (926.2 LBS / 343.9 SQFT)2.69 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 5.2 FT = MAX(MIN(0.4 * 13.0 FT, 0.1 * 59.5 FT), 0.04 * 59.5 FT, 3 FT) P-147695 GRID-TIED SOLAR POWER SYSTEM5111 BIRCH DRFORT PIERCE, FL 34982ATTACHMENT PLAN DOC ID:147695-182295-1 DATE:10/21/20 CREATOR: REVIEWER: REVISIONS PV-5.2 P-147695 GRID-TIED SOLAR POWER SYSTEM5111 BIRCH DRFORT PIERCE, FL 34982ATTACHMENT DETAILS DOC ID:147695-182295-1 DATE:10/21/20 CREATOR: REVIEWER: REVISIONS PV-6 GENERAL NOTES 1 ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED OVER OPENINGS (WINDOWS OR DOORS), ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION, AND ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS (TREE LIMBS, WIRES, OR SIGNS). (NFPA 1 11.12.2.2.1.3) 2 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO CLOSER THAN 1-1/2 FEET TO A HIP OR VALLEY IF MODULES ARE TO BE PLACED ON BOTH SIDES OF THE HIP OR VALLEY. WHERE MODULES ARE LOCATED ON ONLY ONE SIDE OF A HIP OR VALLEY OF EQUAL LENGTH, THE PHOTOVOLTAIC MODULES SHALL BE ALLOWED TO BE PLACED DIRECTLY ADJACENT TO THE HIP OR VALLEY. (NFPA 1 11.12.2.2.2.1.3) 3 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS THAN 3 FT BELOW THE RIDGE. (NFPA 1 11.12.2.2.2.2) ROADWAY 3.0 FT. WIDE SMOKE-VENTILATION SETBACK, PER NFPA 1 11.12.2.2.2.2 ROOF ACCESS POINT 1.5 FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 11.12.2.2.2.1.3 PV MODULES INSTALLED ON ROOF WITH QUICK MOUNT PV QRAIL MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 4/12 SLOPED ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. THE Q-CELLS Q.PEAK DUO BLK-G5 320 IS TYPE 1. 1.5 FT. WIDE FIRE ACCESS PATHWAY TOTAL PLAN VIEW ARRAY AREA IS 627.9 SQ.FT, WHICH REPRESENTS 19.9% OF TOTAL PLAN VIEW ROOF AREA (3162.4 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. CABLES, WHEN RUN BETWEEN ARRAYS, SHALL BE ENCLOSED IN CONDUIT. P-147695 GRID-TIED SOLAR POWER SYSTEM5111 BIRCH DRFORT PIERCE, FL 34982FIRE SAFETY PLAN DOC ID:147695-182295-1 DATE:10/21/20 CREATOR: REVIEWER: REVISIONS PV-7 Q.PEAK DUO BLK-G5 300-3201 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h)2 See data sheet on rear for further information.Q.ANTUM SOLAR MODULEQuality TestedID. 40032587high reliabilitylow degradationfrequentproduct surveillanceENThe new Q.PEAK DUO BLK-G5 solar module from Q CELLS impresses with its outstanding visual appearance and particularly high performance on a small surface thanks to the innovative Q.ANTUM DUO Technology. Q.ANTUM's world-record-holding cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding performance under real conditions — both with low-intensity solar radiation as well as on hot, clear summer days. THE IDEAL SOLUTION FOR:Rooftop arrays onresidential buildingsANTI PID TECHNOLOGY(APT)HOT-SPOT PROTECT(HSP)TRACEABLE QUALITY(TRA.Q™)YIELD SECURITYANTI LID TECHNOLOGY(ALT) Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher powerclasses, and an efficiency rate of up to 19.3 %.INNOVATIVE ALL-WEATHER TECHNOLOGYOptimal yields, whatever the weather with excellent low-light and temperature behavior.ENDURING HIGH PERFORMANCELong-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™.EXTREME WEATHER RATINGHigh-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa) regarding IEC.A RELIABLE INVESTMENTInclusive 12-year product warranty and 25-year linear performance guarantee2. STATE OF THE ART MODULE TECHNOLOGYQ.ANTUM DUO combines cutting edge cell separationand innovative wiring with Q.ANTUM Technology.UL 1703; VDE Quality Tested; CE-compliant; IEC 61215:2016; IEC 61730:2016, Application class ASpecifications subject to technical changes © Hanwha Q CELLS Q.PEAK DUO BLK-G5_300-320_2018-03_Rev02_NAAt least 98 % of nominal power during first year. Thereafter max. 0.54 % degradation per year.At least 93.1 % of nominal power up to 10 years.At least 85 % of nominal power up to 25 years.All data within measurement tolerances.Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your respective country.Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2).Hanwha Q CELLS America Inc.300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.usMECHANICAL SPECIFICATIONQ CELLS PERFORMANCE WARRANTYPERFORMANCE AT LOW IRRADIANCEIRRADIANCE [W/m²]RELATIVE EFFICIENCY [%] 200 400 600 800 10001101009080Irradiance [W/m²]Relative efficiency [%]Format66.3 in × 39.4 in × 1.26 in (including frame)(1685 mm × 1000 mm × 32 mm)Weight41.2 lbs (18.7 kg)Front Cover0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technologyBack CoverComposite filmFrameBlack anodized aluminumCell6 × 20 monocrystalline Q.ANTUM solar half-cellsJunction box2.76-3.35 in × 1.97-2.76 in × 0.51-0.83 in(70-85 mm × 50-70 mm × 13-21 mm), decentralized, IP67Cable4 mm² Solar cable; (+) ≥ 43.3 in (1100 mm), (−) ≥ 43.3 in (1100 mm)ConnectorMulti-Contact MC4, IP68PROPERTIES FOR SYSTEM DESIGNMaximum System Voltage VSYS[V]1000 (IEC) / 1000 (UL)Safety ClassIIMaximum Series Fuse Rating[A DC]20Fire RatingC (IEC) / TYPE 1 (UL)Max. Design Load, Push / Pull (UL)2[lbs/ft2]75 (3600 Pa) / 55 (2667 Pa)Permitted module temperatureon continuous duty− 40 °F up to +185 °F(− 40 °C up to +85 °C)Max. Test Load, Push / Pull (UL)2[lbs/ft2]113 (5400 Pa) / 84 (4000 Pa)2 see installation manualQUALIFICATIONS AND CERTIFICATESPACKAGING INFORMATIONNumber of Modules per Pallet32Number of Pallets per 53' Trailer30Number of Pallets per 40' High Cube Container26Pallet Dimensions (L × W × H)69.3 in × 45.3 in × 46.9 in(1760 mm × 1150 mm × 1190 mm)Pallet Weight1415 lbs (642 kg)NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product.ENRELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]10095908580751552520010YEARS98Q CELLSIndustry standard for tiered warranties*Industry standard for linear warranties**Standard terms of guarantee for the 10 PV companieswith the highest production capacity in 2014 (as at: September 2014)NADETAIL A0.630" (16mm)0.335" (8.5mm)0.965" (24.5mm)38.58" (980mm)66.3" (1685mm) 4 × Mounting slots (DETAIL A)Frame39.4" (1000mm)37.44" (951mm)1.26" (32mm)8 × Drainage holes13.9“ (352.5mm)4 × Grounding points ø 0.177" (4,5mm) 43.3“ ( 1100 mm) 43.3“ ( 1100 mm)CertifiedUL 1703(254141)TEMPERATURE COEFFICIENTSTemperature Coefficient of ISCα[% / K]+ 0.04Temperature Coefficient of VOCβ[% / K]− 0.28Temperature Coefficient of PMPPγ[% / K]− 0.37Normal Operating Module TemperatureNMOT[°F]109 ± 5.4 (43 ± 3 °C)ELECTRICAL CHARACTERISTICSPOWER CLASS300305310315320MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1PMPP[W]300305310315320Short Circuit Current1ISC[A]9.729.789.839.899.94Open Circuit Voltage1VOC[V]39.4839.7540.0240.2940.56Current at MPPIMPP[A]9.259.319.369.419.47Voltage at MPPVMPP[V]32.4332.7833.1233.4633.80Efficiency1η[%]≥ 17.8≥ 18.1≥ 18.4≥ 18.7≥ 19.0MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2MinimumPower at MPPPMPP[W]224.1227.8231.6235.3239.1Short Circuit CurrentISC[A]7.837.887.927.978.01Open Circuit VoltageVOC[V]37.1537.4037.6637.9138.17Current at MPPIMPP[A]7.287.327.377.417.45Voltage at MPPVMPP[V]30.7831.1131.4431.7632.081Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 G according to IEC 60904-3 ∙ 2800 W/m², NMOT, spectrum AM 1.5 G The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency.Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software.IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+MicroinvertersTo learn more about Enphase offerings, visit enphase.comData SheetEnphase MicroinvertersRegion: AMERICASEasy to Install• Lightweight and simple• Faster installation with improved, lighter two-wire cabling• Built-in rapid shutdown compliant (NEC 2014 & 2017)Productive and Reliable• Optimized for high powered 60-cell and 72-cell* modules• More than a million hours of testing• Class II double-insulated enclosure• UL listedSmart Grid Ready• Complies with advanced grid support, voltage and frequency ride-through requirements• Remotely updates to respond to changing grid requirements• Configurable for varying grid profiles• Meets CA Rule 21 (UL 1741-SA)* The IQ 7+ Micro is required to support 72-cell modules.1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.To learn more about Enphase offerings, visit enphase.com© 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-11-19INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-USIQ7PLUS-72-2-US / IQ7PLUS-72-B-USCommonly used module pairings¹235 W - 350 W +235 W - 440 W +Module compatibility60-cell PV modules only60-cell and 72-cell PV modulesMaximum input DC voltage48 V60 VPeak power tracking voltage27 V - 37 V27 V - 45 VOperating range16 V - 48 V16 V - 60 VMin/Max start voltage22 V / 48 V22 V / 60 VMax DC short circuit current (module Isc)15 A15 AOvervoltage class DC portIIIIDC port backfeed current0 A0 APV array configuration1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC) IQ 7 MicroinverterIQ 7+ MicroinverterPeak output power250 VA295 VAMaximum continuous output power240 VA290 VANominal (L-L) voltage/range²240 V / 211-264 V208 V / 183-229 V240 V / 211-264 V208 V / 183-229 VMaximum continuous output current1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V)Nominal frequency60 Hz60 HzExtended frequency range47 - 68 Hz47 - 68 HzAC short circuit fault current over 3 cycles5.8 Arms5.8 ArmsMaximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC)Overvoltage class AC portIIIIIIAC port backfeed current0 A0 APower factor setting1.01.0Power factor (adjustable)0.85 leading ... 0.85 lagging0.85 leading ... 0.85 laggingEFFICIENCY@240 V@208 V@240 V@208 VPeak efficiency97.6 %97.6 %97.5 %97.3 %CEC weighted efficiency97.0 %97.0 %97.0 %97.0 %MECHANICAL DATAAmbient temperature range-40ºC to +65ºCRelative humidity range4% to 100% (condensing)Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US)MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter)Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US)Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors:- PV2 to MC4: order ECA-S20-S22- PV2 to UTX: order ECA-S20-S25Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket)Weight1.08 kg (2.38 lbs)CoolingNatural convection - No fansApproved for wet locationsYesPollution degreePD3EnclosureClass II double-insulated, corrosion resistant polymeric enclosureEnvironmental category / UV exposure ratingNEMA Type 6 / outdoorFEATURESCommunicationPower Line Communication (PLC)MonitoringEnlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy.Disconnecting meansThe AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690.ComplianceCA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions.Enphase IQ 7 and IQ 7+ Microinverters QRail — Fully Integrated Mounting and Racking SystemThe QRail Series is a strong and versatile solar array mounting system that provides unrivaled benefits to solar designers and installers. Combined with Quick Mount PV’s industry-leading waterproof mounts, QRail offers a complete racking solution for mounting solar modules on any roof. QRail, together with Quick Mount PV’s waterproof mounting products, provides the benefit of a single-sourced, seamlessly integrated rooftop installation that works with all roof types — composition/asphalt shingles, flat or curved tile, metal shingle, shake, slate and low slope roofs. The QRail system also works with any roof attachment system for maximum flexibility.Comprehensive, One-Source SolutionFast, Simple Installation: It Just ClicksThe QRail system provides an integrated electrical bonding path, ensuring that all exposed metal parts and the solar module frames are electrically connected. All electrical bonds are created when the components are installed and tightened down.Fully Integrated Electrical BondingQClick TechnologyThe universal mid and end clamps use patented QClick technology to simply “click” into the rail channel and remain upright, ready to accept the module. The pre-assembled clamps fit virtually all module frames and require no extra hardware, eliminating pre-loading and reducing installation time.Superior Strength and VersatilityQRail is engineered for optimal structural performance. The system is certified to UL 2703, fully code compliant and backed by a 25-year warranty. QRail is available in Light, Standard and Heavy versions to match all geographic locations. QRail is compatible with virtually all modules and works on a wide range of pitched roof surfaces. Modules can be mounted in portrait or landscape orientation in standard or shared-rail configurations.STANDARDLIGHT123click!click!2 clamps for modules from 30-45mm or 38-50mm thickUNIVERSAL END CLAMP2 clamps for modules from 30-45mm or 38-50mm thickUNIVERSAL BONDED MID CLAMPQRail’s innovative internal QSplice installs in seconds, requiring no tools or screws. Simply insert QSplice into the rail and slide the other rail on to create a fully structural, bonded splice. An external splice is also available.QSplice TechnologyQSPLICEHEAVYQRails come in two lengths —168 inches (14 ft) and 208 inches (17.3 ft)™™231Mill and Black FinishInstalls in seconds — no tools or hardware requiredInstalling is as easy as 1-2-3Easily design array configurations with the QDesign software application. Generate complete engineering reports and calculate a precise bill of materials for all the mounting, racking and accessories needed for a complete solar array.™ 1AVAILABLE IN MILL, AND BLACK FINISHES234*5* STRUCTURAL SCREW AVAILABLE ON QMLM-ST VERSIONS ONLY 3.30 .040 3.54 2.00 .90 2.50 .397 2.09 1.00 QMLM 3.00 4.50 9.00 12.00 4.20 THIS EDGE TOWARDS ROOF RIDGE 4.04 2.75 QMLM-STITEM NO.DESCRIPTIONQTY.1FLASHING, ROUNDED CORNERS, 9" X 12" X .040", .438" HOLE, 5052, MILL12L-FOOT, 2" X 3.30" FOR .438" O.D. FASTENER, 2-1/16" SLOT, 6061-T6/6005A-T61, MILL13WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS14LAG SCREW, HEX HEAD, 5/16" x 4", 18-8 SS1*5STRUCTURAL SCREW, QMPV, T-30 HEX WASHER HEAD, 5/16" X 4-1/2", 18-8SS19DO NOT SCALE DRAWINGSHEET 1 OF 1RADSCALE: 1:4WEIGHT:REVASIZETITLE:DATE:DRAWN BY:DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONAL 1/8TWO PLACE DECIMAL .19THREE PLACE DECIMAL .094PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. COPYRIGHT © 2016 QUICK MOUNT PV54321UNLESS OTHERWISE SPECIFIED:1.0723QMLM & QMLM-ST: L-MOUNT, 2-1/16" SLOT7/16/2018