Loading...
HomeMy WebLinkAboutproduct approval.:_:..-.. BCIS Home Log In User Registration', Hot Topics '., Submit Surcharge ! Statr &Facts i Publications Contact Us BCIS Site Map Links Search 7 Florida+ 13 " Product Approval ;I USER: Public User '. c tar:Mtt Product Approval Menu > Product or Application Search -- oA - •....r tion Detail � "M7� # FL27499-RI Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Dynamic Meta s 3201 SE Dominica Terace Stuart, FL 34997 juan@dynamicmetai.net Authorized Signature Lara Jesus juan@dynamicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/31/2026 Validated By Lucas A. Turner, P.E., MBA Validation Checklist - Hardcopy Received Certificate of Independence FL27499 RI COI Dyn COI.pdf eferenced Standard and Year (of Standard) Standard ar TAS 100 1995 TAS 110 2003 TAS 125 2003 Equivalence of Product Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised iummary of Products FL # Model, Number or Name 27499.1 DM Class 1000 1" Nailstrip Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. 27499.2 DM Class 1000 1" Nailstrip, Lim ;:; f Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other. Please see Eval report for Limits of Use. 27499.3 02/22/2019 08/29/2019 08/30/2019 10/15/2019 10/24/2020 DM Class 1050 1 1/2" Nailstrip Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eva] report for Limits of Use 27499.4 1 DM Class 1050 1 1/2" Nailstrip Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other. Please see Eval report for Limits of Use. Description 26 Ga. galvalume coated steel roof panel, 16" wide, with 1" snap fit seams. Installation Instructions FL27499 P1 II NSSI6HZ pelf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 R1 AE DM Evall j2d Created by Indenendent Third party• Ypc _032" Aluminum roof panel, 16" wide, with 1" snap fit seams. Installation Instructions FL27499 R1 II NSAI6HZ pd Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 RI AE DM Eval2.pdf Created by Independent Third Party: Yes .032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit seams. Installation Instructions FL27499 R1 II NSAI9HZ.pdf Verified By: Scott Wolters, P.E. FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 RI AE DM Eval3.gdf Created by Independent Third Party: Yes 24 Ga. Galvalume coated steel roof panel, 19" wide, with 1 1/2" snap fit seams Installation Instructions FL27499 R1 II NSSI9HZ.pdf Verified By: Scott Wolters, P.E. FLPE# 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 R1 AE DM Eval4.pdf Created by Independent Third Party: Yes 27499.5 DM Class 1500 1 1/2" Mechanical .032" Aluminum roof panel, 20" wide, with 1 1/2" standing Seam I seams. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. --- �r 27499.E I DM Class 1500 1 1/2" Mechanical Seam Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. 27499.7 DM Class 1500 1 1/2" Mechanical Seam Limits of Use Approved for use in HVHZ: Yes Installation Instructions FL27499 R1 II 15M A 0HZ 12d Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 R1 AE DM Eval5.pdf Created by Independent Third Party: Yes 16 oz. Copper roof panel, 16" wide, with 1 1/2" standing seams. Installation Instructions FL27499 R1 II 15M CHZ.pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 Rl AE DM Eval6 pdf Created by Independent Third Party: Yes 26 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2" standing seams. Installation Instructions FL27499 R1 II 15MSS1626HZ.pdf I Approved for use outside HVHZ, Yes i Verified By: Scott Wolters 62354 Impact Resistant. N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other. Please see Eval report for Limits of Use. FL27499 R1 AE DM Eyal7.pd Created by Independent Third Party: Yes 27499.8 DM Class 1500 1 1/2" Mechanical I fj '032" Aluminum roof panel, 16" wide, with 1 1/2" standing I Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R1 11 15MSA16HZ.pdf Approved for use outside HVHZ. Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva[ report for Limits of Use. FL27499 R1 AE DM Eval&p _d Created by Independent Third Party: Yes 27499.9 DM Class 1500 1 1/2" Mechanical 24 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2" Seam standing seams. Limits of Use Installation Instructions Approved for use in HVHZ.- Yes FL27499 P1 11 15MSS16HZ.pd Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant. N/A Created by Independent Third Party: Yes Design Pressure- N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eval9.pd Created by Independent Third Party., Yes 27499.10 DM Class 1500 1 1/2" Mechanical 24 Ga. galvalume coated steel roof panel, 20" wide, with 1 1/2" Seam, standing seams. 'Limits of Use Installation Instructions Approved for use in HVHZ. Yes FL27499 R1 11 15MSS20HZ.pdf Approved for use outside HVHZ. Yes Verified By: Scott Wolters 62354 Impact Resistant. N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Evall0.2dd Created by Independent Third Party: Yes 127499.11 DM Class 1750 1 3/4" Snaplock 24 Ga. Galvalume coated steel roof panel, 18" wide, with I 3/4" Snaplock seams, attached to metal deck. i I I Limits of Use F Installation Instructions Approved for use in HVHZ- Yes FL27499 Ri II SLSISBDHZ.pd Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354 Impact Resistant. N/A Created by Independent Third Party: Yes Design Pressure. N/A Evaluation Reports Other. Please see Eval report for Limits of Use. FL27499 R1 AE QM Evalll.pd Created by Independent Third Party: Yes 127499.12 DM Class 1750 1 3/4" Snaplock 1.032" Aluminum roof panel, 18" wide, with 1 3/4" Snaplock I I seams, attached to metal deck, I Limits of Use Installation Instructions Approved for use in HVHZ. Yes FL27499 R1 11 SLAISBDHZ.pd Approved for use outside HVHZ. Yes Verified By: Scott Wolters 62354 Impact Resistant. N/A Created by Independent Third Party: Yes Design Pressure. N/A Evaluation Reports Other. Please see Eval report for Limits of Use. FL27499 R1 AE DM Evall2.pd Created by Independent Third Party: Yes 27499.13 j DM Class 1750 1 3/4" Snaplock 032" aluminum roof panel, 18" wide, with 1 3/4" Snaplock -seams. Limits of Use Installation Instructions Approved for use in HVHZ- Yes FL27499 R1 II SLA18HZ.pqf Approved for use outside HVHZ-. Yes Verified By: Scott Wolters 62354 Impact Resistant- N/A f Created by Independent Third Party: Yes Design Pressure- N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eval13.pd Created by Independent Third Party: Yes i27499.14 DM Class 1750 1 3/4" Snaplock 24 Ga. galvalume coated steel roof panel, 18" wide, with 1 3/4" Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R1 II SL518HZ.pd Approved for use outside HVHZ. Yes d Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure. N/A I Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Evail4.pd Created by Independent Third Party: Yes 27499.15 1 DM Class 2000 2" Mechanical Seam 1.032 Aluminum roof panel, 18" wide, with 2" standing seams. i Limits of Use Approved for use in HVHZ: Yes Installation Instructions FL27499 R1 II 2MSA18HZ.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A } Created by Independent Third Party: Yes Design pressure. N/A Evaluation Reports Other: Please see Eval report for Limits of Use. 1 FL27499 R1 AE DM EvallS.pdf 1 ? Created by Independent Third Party: Yes 27499.16 DM Class 2000 2" Mechanical Seam j 24 Ga. gatvaiume coated steel roof panel, 18" wide, with 2" 3 standing seams. Limits of Use Approved for use in HVHZ: Yes Installation Instructions FL27499 Rl II 2MSS18HZ.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Scott Wolters 62354 � Resign pressure: N/A Created by Independent Third Party: Yes � Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Evall6.pdf Created by Independent Third Party: Yes Wu 's 27499.17 �DM Class SQO SV Crimp j 26 Ga. galvalume coated steel roof panel, 24" wide, with SV Ecrimp. Limits of Use �' Installation Instructions i Approved for use in HVHZ: Yes FL27499 R1 11 5VS.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Scott Wolters 62354 Design pressure: N/A Created by Independent Third Party: Yes Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eval17.pdf Created by Independent Third Party: Yes 27499.18 j DM Class 500 5V Crimp _ .032" Aluminum roof panel, 24" wide, with 5V Crimp Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R1 11 5VAL.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes i Design pressure: N/A : Evaluation Reports I Other: Please see Eval report for Limits of Use FL27499 R1 AE DM Evall8.pdf Created by Independent Third Party: Yes aaci< Exr Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication rrith the licensee. However email addresses are public record. if you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ..,.,,.M ® RR Credit Card Safe CtE Ir@ikT��'