HomeMy WebLinkAboutPermit Worksheet PERMIT WORK51-IEE I I page'i orz
E\. J
-PERMIT NUMBER
-New Home ® _Used'Home ❑
Installer EDDIE GRUNDEL License# IH1118467
Home installed to the M6nuf6cturer's Installation Manual
Address of home 478 nettles blvd Home is installed in accordance,with Rule 15=C
being installed
Single wide E] Wind Zone II Wind Zone III
Manufacturer J9
acobsen Length xwidth L^ Double wide Installation Decal# TBD
.
!VOTE:_ if home is a single wide fill out one half of the blocking plan Triple/Quad 'Serial#
if home is a triple or quad wide sketch in remainder of home
I understand Lateral Arm Systems cannot'be used on any home (new or used) PIER SPACING TABLE FO�6ED HOMES
where the sidewall ties exceed 5 ft4 in.
Installer's nl pFl NS'
_. �n
Y1�7 Load Footer Q
ST.LUC v— TJNTY... Z° TNC:eP.-790N 16"x 1 C ply CYp�E � S" 22"x22" 24"X24" 26"x26"
bearing size �1
A t EE iQ/10 � �GS a �00) (484)* (576)* (676)
Typical pier spacing ]R—lWVWWED FOIL CE `lye/ capacity (sq in}` gU \E\ D S
JI EV1A1,, ED B . E Y P oR QDE
2 6 lateral r pS Q ES \.\
Show IARNO
p g�� SDyst�ms Ps N ZNlongitudinal (ut® �` _ V19'�'J T®N J10 pS Q
LLNSPECTION WILL BE MADE. 2500 ps
3000 ps
. . ps
* interpolated from Rule 15G1 pier spacing table.
PIER PADSIZES POPULAR PAD SIZES
I-beam pier pad size 17X22.5,;,
fl �a s„'gYt
,,a
Size q n
'Perim er' QVAbIKJlrlo �„v 16 x
size. � 16 x 18 28T
pit 18.5
Other pier pad sizes x
(required bythe mfg.) x 4
;•• �— \ 13 4 x 4 348
Draw the approximate locations of marriag 20 x20 4
wall openings 4 foot or greater. Use this x25 37TiF 4
marria 1 pie within T of end of home per Rule 15C symbol t0 show the piers. X 1
24 x24 576--
F
List all marriage wall openings greater than 4fool 26 x 7
and their pier pad sizes below.
ANCHORS
Opening Pier pad size
-r-r-I- I- -T-r-r-r-1--I- 1-7-r-r-r-r-1- -T-r-r-r-r I- -z-r-r-r-r�- -7-r-r- Oft X 5ft
1 1 1 I 1 1 1 I 1 1 1 1 1 I I I I 1 1 1 I 1 I I 1 1 1 I I 1 I I 1 1 1 1 -
r-r-r -,--,- -;-r-i-1 1 I I 7-,--r-r-,--,-�-7-r-,--i'-1--I-1-7-7_1r_:
I 1 1 I 1 J
_1-1 _I _�_!-!_!_1-!_L-L.._-__:-J_2_L-L J_!_!-J_!_!_L_i_-i_ ; J_1_L_ -`� 17X22.5
I 1 1 1 1
_ -J- -1-L-'--'- .- - .. _ _ FRAMETI
1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I 1 V-1,
I 1 1 1 1
L-L-1--1-J-i-L-L_L-1_-i--,-1-L-L-I--1- -1 - -1- L L-
1 1 I I 1 1 i I within 2'of end of home X
r-r--1-�-�.---r-r-r-I--I-�-*-r-r-r-r , -r-r-�--�-�-�-T-r-r- I- �-7-r-r-r•_,
I I 1 1 1 I I I I I 1 1 1 1 1 1 1 1 1 1 I 1 1 I I 1 I 1 1 1 Ir
1 I spaced at 5'4'
,
or.. x
-1-1-'r-r- r- �-1-7-T-r-I -
I I I 1 1 1 1 I 1 1 I I 1 1 1 I I I 1 I I 1 1 1 1 1 1 I 1
a[
ro ,_r TIEDOWN COMPONENTS
dip #1
I 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 _,•,m ber
L-1-!-J-J1-1-L-L---1_J-J-1-L-L_1 - J -1-L-�_-1_J-J_.1_L-L- 1- J-1-L-L-1--1
Longitudinal Stabilizing Device(LSD) FIL0—Wal
l-50F
L-1-J--1-1.-L-L-L-1-J,--1-i-L-F-L-1--1- i 1--I-J-•i-+-}-L-L�1 -1-L-L--F--1-J
Manufacturer OLIVER Longitudinal
/--1--I-•t-;-r-F•-I--1-••,-"1- -j'-1•-1--1--,- r- r- -+-"1- 1-�, -�- f-r-f--1-'�, ..
1 ��.-1 �p,^�l�►1 I I l�rn' 1 1 1 1 1 I 1 Longitudinal Stabilizing Device w7 Lateral Arms Warriage wall
r-r-r-,-ti- - -r-r-r-,--1- - -r-r-r r - •r- -1- -T-r-r-' Manufacturer Shearwall
I 1 I I 1 1 1 1 I I I 1 1 1 1 1 1
r-r-r l-�-7-r-r-r-1-'-1-1- -r-r-i-I--I-1-7-r-r-r-r-1-1-7-r-r-f -r-7n-7-i'-r-r-i
I
I
` PERMIT WORKSHEET I page z oT z
�PF:RMIT NUMBER
Site Preparation
POCKET PENETROMETER TEST
Debris and organic material removed YES
The pocket penetrometer tests are rounded down to 1500 psf Water drainage: Natural Swale Pad X—Other
or check here to declare 1000 Ib.soil withouttesting.
Fastening multi wide units
X 150( - X 150(" X 150C
Floor: Type Fastener: LAG Length: 6" Spacing: 24"
Walls: Type Fastener: LAG Length: "
' Spacing: 24
POCKET PENETROMETER TESTING METHOD Roof: Type Fastener: GALV Length: Spacing:
For used homes a min. 30 gauge, 8"wide,galvanized_ metal strip
1. Test the perimeter ofthe home at 6 locations. will be centered over the peak of the roof and fastened with gals.
roofing nails at 2"on center on both sides of the centerline.
2. Take the reading at the depth of the footer.
Gasket(woathorproofing roquiromont)
3. Using 500 Ib. increments,take the lowest
reading and round down to that increment. I understand a properly installed gasket is a requirement of all new and used
homes and that condensation, mold, meldew and buckled marriage walls are
a result of a poorly installed or no gasket being installed. I understand a strip
X 150C X 150( X 150( of tape will not serve as a gasket.
Installer's initials TG
TORQUE PROBE TEST
Type gasket FOAM Installed:
The results of the torque probe testis 285 inch pounds or check Pg. Between Floors Yes X
here if you are declaring 5'anchors without testing . Atest Between Walls Yes X
showing 275 inch pounds or less will require 5 foot anchors. Bottom of ridgebeam Yes X
Note: Astate approved lateral arm system is being used and 4 ft..
anchors are allowed at the sidewall locations. I understand5 ftWeatherproofing
anchors are required at all centerline tie points where the torque test
reading is 275 or less and where the mobile home manufacturer may The bottom board will be repaired and/or taped. Yes X Pg.
requires anchors with 4000 Ib holding capacity. Siding on units is installed to manufacturer's specifications. Yes
TG Installer's initials Fireplace chimney installed so as notto allow intrusion ofrain water. Yes X
ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER Miscellaneous
Installer Name THOMAS GRUNDEL Skirting to be installed. Yes X No
Dryer vent installed outside of skirting. Yes X N/A
Date Tested Range downflow vent installed outside of skirting. Yes X N/A
Drain lines supported at4 foot intervals. Yes X _
Electrical crossovers protected. Yes X
Other:
Electrical
onnect electrical conductors between multi-wide units, but notto the main power
nurce. This includes the bonding wire between mult-wide units. Pg.
Installer verifies all information given with this permit workpheet
Plumbing is accurate and true based theI)
manufacturer's installatio instr ctions� o ta,e 1 2
onnect all sewer drains to an e)asting sewer tap or septic tank. Pg.
onnect all potable water supply piping to an e)asting water meter,water tap, or other Installer Signature Date
eJ e�nonrlent ni�Fcr ciinnlr evc tcmc Pn
-DIA-7