Loading...
HomeMy WebLinkAboutProduct Evaluation ReportBUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 i JELD-WEN, Inc. 398 E. Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Premium Atlantic Vinyl Single Hung - Impact for Florida Product Approval Current Florida Building Code Method: 1— A (Certificate) Category: Windows Sub — Category: Single Hung Product: Premium Atlantic Vinyl Single Hung - Impact Material: PVC Product Dimensions: 3 6 " x 72" (O/X) Prepared For: JELD-WEN, Inc. 3737 Lakeport Blvd. Klamath Falls, OR 97601 Prepared by: ``���ur, i i i,it11,1 Hermes F. Norero, P.E. .�� DES F. O '0:' Florida Professional Engineer # 73778 �`� Q- ,..••'•' "w• . �` ��i Date: 08/11/2014 �� Z�;' �,� '� �p 7 Contents: Evaluation Report Pages 1— 4 = D. T T Digitally signed by Hermes F. Norero,'�•.F�, •''••••••••'•• 'G�=�` Reason: I am approving this document It E����� Date: 2014.09.1916:31:49-04'00' Hermes F. Norero, P.E. Florida No. 73778 BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Manufacturer: Product Category: Product Sub -Category: Compliance Method: JELD-WEN, Inc. Windows Single Hung State Product Approval Method (1)(a) Product Name: Premium Atlantic Vinyl Single Hung — Impact (Impact) 36" x 72" (O/X) Date: 08/11/2014 Report No: 3094 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, Inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions NCTL210-3875-1-FBC, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing NCTL210-3875-1-FBC require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions NCTL210-3875-1-FBC for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 BUILDING DROPS Rate: 0 °�4 Report Noo: : 3094 A Perfect Solution in Every Drop Certificate of Authorization: 29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization #: QUA 1789). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories NW (FBC Organization # TST9341) Report #: NCTL-210-3875-1, Report Date: 4/18/2013 2. Certification Agency National Accreditation and Management Institute (FBC Organization #: CER 1773) 3. Material Certification Miami Dade RER— Product Control Section NOA E.I. DuPont De Nemours & Co., Inc.: PVB Interlayer 4. Material Certification Miami Dade RER— Product Control Section NOA Quanex Building Products: PVC Extrusions Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 ib BUILDING DROPS Date: 0: 30 4 Report No: 94 A Perfect Solution in Every Drop q Certificate of Authorization: 29578 Through Frame Installation: 1. Approved anchor types and substrates areas follows: A. For concrete (Min. f c = 3000 psi) or masonry substrate (Min. f c = 1500 psi) where one by (1X), non-structural, wood bucking is employed, use (1) 3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. B. For concrete (Min. fc = 3000 psi) or masonry substrate (Min. fc = 1500 psi) where wood bucking is NOT employed, use (1) 3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For steel substrate, use (1) #8 Tek Screw type steel frame (min. 18ga.) anchors per location of sufficient length to achieve minimum three threads of penetration beyond steel structure. Nail Fin Installation (Where applicable): A. For wood substrates (Min. S.G. = 0.42) use (1) #10 Wood Screw type installation anchors per location of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. Refer to Installation Instructions (NCTL210-3875-1-FBC) for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Positive 65 PSF Negative 70 PSF Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4