Loading...
HomeMy WebLinkAboutBuilding PlansI&„ S =- y Planning & Development Services Department Building & Code Regulations Division � g g SHEATHING OR PLYWOOD STUD pI SPA C'iIVG STUDS UDS ,� ' 2300 Virginia Avenue, Fort Pierce,.FL34982— (772) 462-1663 Certification for Design Load Compliance Project Name: GARAGEADDITION NAILS `-• ���� Project Address 8239CINNAMONCT. �nY�� g a -----.-...-.-._-__,_, Permit#: Occupancy Type: R Construction Type: V"�"^�8—=�'�.""•""^�--. INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. A - • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Additio . - - o o Any accessary structure requiring a building permit - .. '�+ a C0 -. o Any non-residential structure.. " Note: Form not required for interior renovations provided that no exterior structural elements are affected and - VINYL SIDING certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) - . - 1. DESIGN CODE: Florida Building Code 2017 6th Edition with 20 _supplements using ASCE7-11 Saint Lucie County Building Department Product Approval Submittal Affidavit Permit # I Building Address: SEE PLAN I Contractor: TBD Opening Schedule : Swing doors, Overhead Doors, Sliding Doors, Fixed Glass, Windows & Skylights Opening ID p n8 FL # or NOA # Product Model # Manufacturer Glass Description Attachment Method Type, Size, Spacing & Embedment (DISTANCE FROM CORNER / DISTANCE O.C.) Building Design Pressure Product Design Pressure S.H. WINDOW FL- 14095.1 S.H. WINDOW VINYL JELDWEN IMPACT #10 WOOD SCREWS W/ 11/2" MIN. EMBD. @ 4"/16" O.C. SEE ELEV'S +65/-70 8070 ROLL -UP DOOR FL# 17399.2 O.H.D 790 WAYNE DALTON N/A 1/4" X 2 1/2" LAGS @ 12" O.C. SEE ELEV'S +/-36 Product Model # Manufacturer Attachment Method Type Spacing, Embedment & Stiffener etc. Building Design Pressure Product Design Pressure Roof FL# 7561:1 3" COMPPANELS ELITE/3" X 0.032" X 1 LB EPS SEE PLAN 66.7 70 Siding FL# 23885.1 SIDING IVINYL 1PLYGEM N/A PER DETAIL ON PLAN -34.8 -45 1 have reviewed the above product approval information and approve it. Name: Paul Welch P.E. Certification Number: 29945 1 ALL GLAZED EXTERIOR OPENINGS SHALL BE IMPACT RESISTANT. I SCOPE OF WORK CONSTRUCT NEW ADDITION PER PLAN - NEW ADDITION IS TO BE FREESTANDING PER PLAN AND SHALL NOT BE CONNECTED TO EXISTING STRUCTURE NOTE: ALL CONSTRUCTION MUST COMPLY WITH THE FBC 17, AND THE FBC 17 RESIDENTIAL, 2017 PLUMBING CODE, 2017 MECHANICAL CODE AND THE NEC (NFPA 70) 2014 EDITION. ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE FBC 17 FOR EXISTING BUILDINGS, THE FBC 17, AND THE FBC 17 RESIDENTIAL THIS IS AN ALTERATION LEVEL 2 AND MUST COMPLY WITH THE FBC 17 FOR EXISTING BUILDINGS CHAPTER 6 AND 7 NOTES: THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. - STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER OnA[ r-rN w v Z O N L O� 1 �- � N ILLJ u z O N c..a M