HomeMy WebLinkAboutDM CLASS 1000 - 27499.1 (HVHZ APPROVED)4/10/2020 Florida Building Code Online
`.-
s
BCIS Home Log In ( user Registration ( Hot Topics Submit Surcharge Stats & Facts I Publications ( Contact Us ( BCIS Site Map Links Search
Florida
",s : ,Product Approval
:USER: Public User
b
o,
Product pproval Menu > Product or Application Search > Application List > Application Detail
FL #
FL27499-R1
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Year
Archived
1995
Product Manufacturer
Dynamic Metals
Address/Phone/Email
3201 SE Dominica Terace
Stuart, FL 34997
(772) 872-8030
juan@dynamicmetal.net
Authorized Signature Lara )esus
juan@dynamicmetai.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
. _ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License PE -62354
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Lucas A. Turner, P.E., MBA
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
, Validation Checklist - Hardcopy Received
FL27499 R1 COI Dyn COI pdf
Standard
Year
TAS 100
1995
TAS 110
2003
TAS 125
2003
hftps://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQvvtDquHOE2Ywe%2bOsCepABg3%2bkM6B4KrS3X7m7RLNDTr%2fv7QaQ%3d%... 1/4
4/10/2020 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL #
27499.1
Model, Number or Name
DM Class 1000 1" Nailstrip
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A -
Other: Please see Eval report for Limits of Use.
27499.2 ( DM Class 1000 1" Nailstrip,
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
02/22/2019
08/29/2019
08/30/2019
10/15/2019
27499.3 ( DM Class 1050 1 1/2" Nailstrip
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eva] report for Limits of Use.
27499.4 1 DM Class 1050 1 1/2" Nailstrip
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
27499.5( DM Class 1500 1 1/2" Mechanical
Seam
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
27499.6( DM Class 1500 1 1/2" Mechanical
Seam
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
27499.7( DM Class 1500 1 1/2" Mechanical
Seam
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Description
26 Ga. galvalume coated steel roof panel, 16" wide, with 1"
snap fit seams.
Installation Instructions
FL27499 R1 II NSSI6HZ.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R1 AE DM Evall pdf
Created by Independent Third Party: Yes
.032" Aluminum roof panel, 16" wide, with 1" snap fit seams.
Installation Instructions
FL27499 Rl II NSAI6HZ pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R1 AE DM Eval2.pdf
Created by Independent Third Party: Yes
.032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit
seams.
Installation Instructions
FL27499 Rl II NSAI9HZ pdf
Verified By: Scott Wolters, P.E. FLPE# 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 Rl AE DM Eval3.pdf
Created by Independent Third Party: Yes
24 Ga. Galvalume coated steel roof panel, 19" wide, with 1
1/2" snap fit seams
Installation Instructions
FL27499 Rl II NSSI9HZ pdf
Verified By: Scott Wolters, P.E. FLPE# 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 RI AE DM Eval4.pdff
Created by Independent Third Party: Yes
.032" Aluminum roof panel, 20" wide, with 1 1/2" standing
seams.
Installation Instructions
FL27499 R1 II 15MSA20HZ pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 Rl AE DM Eval5.pdf
Created by Independent Third Party: Yes
16 oz, Copper roof panel, 16" wide, with 1 1/2" standing
seams.
Installation Instructions
FL27499 Rl II 15MSCHZ pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 RI AE DM Eval6.pdf
Created by Independent Third Party: Yes
26 Ga, ga]valume coated steel roof panel, 16" wide, with 1 1/2"
standing seams.
Installation Instructions
FL27499 Rl 1I 15M551626HZ pdf
Verified By: Scott Wolters 62354
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6B4KrS3X7m7RLN DTr%2fv7QaQ%3d°/o... 2/4
ENGINEERING, DRAFTING, CONSULTING
15211 97th Road N
West Palm Beach, FL 33412
Ph/Fx:(561) 225-1982
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
PRODUCT: DM CLASS 1000 26 GA. GALVALUME 1" NAILSTRIP 16" WIDE
ROOF PANEL (FLPA# 27499.1)
MANUFACTURER: DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The DM Class 1000 Series 26 Ga. Galvalume 1" Nailstrip 16" Wide Roof Panel, manufactured by Dynamic
Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the
requirements of Sections 1507.4 and 1518.9 of the 61h Edition (2017) Florida Building Code. The panel has been
tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.40-450-44 and G3443.14-
450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-
02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing 'NSS16-HZ" dated 8/15/19, signed and sealed by Scott Wolters, PE,
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and
by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE,
3. Supplemental Calculations to support "NSS16-HZ" drawing, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 16" (nominal)
Fastener Spacing across panel: 16" (at Nailstrip)
(Panels overlap with male/female snap fit)
Min. Slope: HVHZ: 2"/12"
Non-HVHZ: '/2'/12" (with Lap Sealant)
3'712" (no Lap Sealant in Field Zone)
5FFClXIZIN6IN IMPACTFF515TANTCUp AINWN,I.5, 51O&FONI-5, & WIN[70W5
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Underlayment: Minimum ASTM D 226 Type II with 4" overlaps and 6" end -laps, anchored
with 12 Ga. x 1 %` galvanized roof nails with 32 Ga. Tin caps spaced 6"
O.C. in rows at the perimeter, at overlaps, and two intermediate rows
staggered and spaced 12" O.C.
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, V round plastic caps may be used to prevent
galvanic reactions.
Minimum Substrate: % (15/32" min) 4 -ply CDX Plywood, nailed to 2x rafters spaced 24" max.
O.C. with 8d ring -shank nails spaced 4" O.C.
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
4. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. All panels shall be permanently labeled with the manfacturer's name
and/or logo, and the following statement, "Dynamic Metals
FL# 27499, 1, DM Class 1000".
5PFCIAI RING IN INTACT rH5fft CU6IAINWAl.1.5, 5 OFFFroNTS, & WINbOW5
Field
Installation
Perimeter & Corner
Installation
Max. Design Pressure:
-116 psf
_
-176 psf
Fastener Spacing:
3" From Ends, 6" Max. O.C.
3" From Entls, 6" Max. O.C.
Min Panel Fasteners:
#10x1" Panclip Fasteners
#10x1" Panclip Fasteners
Panel Sealant:
Continuous bead of Geocel 2300
or 2320 at Nailstrip side of seam
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Underlayment: Minimum ASTM D 226 Type II with 4" overlaps and 6" end -laps, anchored
with 12 Ga. x 1 %` galvanized roof nails with 32 Ga. Tin caps spaced 6"
O.C. in rows at the perimeter, at overlaps, and two intermediate rows
staggered and spaced 12" O.C.
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, V round plastic caps may be used to prevent
galvanic reactions.
Minimum Substrate: % (15/32" min) 4 -ply CDX Plywood, nailed to 2x rafters spaced 24" max.
O.C. with 8d ring -shank nails spaced 4" O.C.
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
4. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. All panels shall be permanently labeled with the manfacturer's name
and/or logo, and the following statement, "Dynamic Metals
FL# 27499, 1, DM Class 1000".
5PFCIAI RING IN INTACT rH5fft CU6IAINWAl.1.5, 5 OFFFroNTS, & WINbOW5
Pang[ Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 3rd party QA provider, to the dimensions shown on Drawing NSS1 6 -HZ:
SSQ-6800617 SSQ-5150216 SSQ-6810617
SSQ-6690517 SSQ-4560615 SSQ-8681118
5VC-0490718 5VC-0360516 5VC-0521218
Re -Roofing:
The DM Class 1000 Series 26 Go, Galvalume V Nailstrip 16" Wide Roof Panel
may be installed over a single layer of existing asphalt shingles, provide the existing roof
meets the requirements of Section 1521 (HVHZ) or Section 1511 (outside of HVHZ) of the
Florida Building Code.
If you have any questions or need more information concerning this approval please contact me,
Thank you,
'�J%Mff�"
kk I t1"
C)oz'�' e
C E fv'&**'
No 62354
4 *0,.rs
FL PE# 62354
STATEJz
0 F .4u
e.
AUG 1, 6 7,919
�0',
0 R 0
�
"
'GTA ZING !N I
aanssx
an` �+?" s�¢4-'uV z9u7 S:Huq Your rvur�Qnp,lasua {L%V'v3 SSCL-bb'�:'495}:Hd
anQ" tY`airc: v `rf.Yr.,efrxha
.tori
_tis xawm rasu'c;v
f4Z1 C*Lq EeB51 XY., Ki'CSfi Alvdd.sim
�:t: f9@[tY va+)
�. w_` UMM1hiJWv]N.1 Se3LlMi
Fs+t+pu
uuvrtvn+:]fYvamra avov filhi ov€
_.;...y ttr YwtYB d3tiL
(�'` }i..{((('�yy fi�tt{{'' �Jy��.JR' �{
JlVi=tVV�V Y.V lykl
'Tom 0
%E
!j
i
m
u
ani c
r5
r
X
ea�ui
it
1tj
R