Loading...
HomeMy WebLinkAboutEnergy calcs4114t� /1-111 2Uv 5 - o -4,2 2 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: JUREK RESIDENCE Builder Name: DAVE GOLDEN HOMES Street: TREETOP TRAIL Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2377.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1967.00 ft2 b. Frame - Wood, Adjacent R=11.0 410.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2070.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2070.00 ft2 6. Conditioned floor area above grade (ft2) 2070 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/Aucts _ 2 R 11 R ft2 7. Windows(352.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: LAUNDRY 6 150 a. U-Factor: Sgl, U=0.40 352.00 ft2 SHGC: SHGC=0.25 ft2 12. Cooling systems kBtu/hr Efficiency b. U-Factor: N/A a. Central Unit 35.2 SEER:16.00 SHGC: c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2070.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2070.00 f12 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Total Proposed Modified Loads: 71.82 Area: 0.170 PASS Glass/Floor Total Baseline Loads: 75.28 1 hereby certify that the plans and specifications covered by Review of the plans and 01 this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. ,; „O +r++TOP PREPARED BY: Before construction is completed DATE: - -202U this building will be inspected for compliance with Section 553.908 I hereby certify that this buildJ,aesignis in mpliance Florida Statutes.with QD the Florida Energy Code VVE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: r i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 10/27/2020 1:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6