HomeMy WebLinkAboutEnergy calcs4114t� /1-111
2Uv 5 - o -4,2 2
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: JUREK RESIDENCE
Builder Name: DAVE GOLDEN HOMES
Street: TREETOP TRAIL
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2377.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1967.00 ft2
b. Frame - Wood, Adjacent
R=11.0 410.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (2070.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2070.00 ft2
6. Conditioned floor area above grade (ft2) 2070
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/Aucts
_ 2
R
11
R ft2
7. Windows(352.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
6 150
a. U-Factor: Sgl, U=0.40 352.00 ft2
SHGC: SHGC=0.25
ft2
12. Cooling systems
kBtu/hr Efficiency
b. U-Factor: N/A
a. Central Unit
35.2 SEER:16.00
SHGC:
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.333 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2070.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2070.00 f12
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Total Proposed Modified Loads: 71.82
Area: 0.170
PASS
Glass/Floor
Total Baseline Loads: 75.28
1 hereby certify that the plans and specifications covered by
Review of the plans and
01
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
,; „O
+r++TOP
PREPARED BY:
Before construction is completed
DATE: - -202U
this building will be inspected for
compliance with Section 553.908
I hereby certify that this buildJ,aesignis in mpliance
Florida Statutes.with
QD
the Florida Energy Code
VVE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
r i
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
10/27/2020 1:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6