HomeMy WebLinkAboutPlans, page 1Finish Columns with
5/8" thick cut coral
finished stucco bands
Union Corrugating Co. 26 ga. 5V crimp metal roofing
FLU: 1211A Attach roofing to deck using 49 x 1.5"
wood screws with washer Per Approval over 30 lb Felt
underlayment installed with min. 4" side laps
and 6" end laps fastened with corrosion resistant tin\
caps with 1 1/4" ring shank nails spaced 6" o.c.
at all laps and two stagggered rows 12" o.c. in field.
ROOF deck to be 19/32' COX plywood nailed to
trusses with 8d x 2,5" long ring shank nails per sheeting
attachment detail on roof plan
Max allowable uplift = 85.8 psf
5/8" thick light textured
12
SLOPE 4
stucco on typical concrete
block construction
5/8" thick x 8"w cut
coral finished stucco bands
RIGHT ELEVATION
SCALE: 1/4" = I'—O"
Union Corrugating Co. 26 ga. 5V crimp metal roofing
FLU: 1211A Attach roofing to deck using #9 x LS"
wood screws with washer Per Approval over 30 lb felt
underlayment installed with min. 4" side laps
and 6" end laps fastened with corrosion resistant tin
caps with 1 1/4" ring shank nails spaced 6" o.c.
at all laps and two staggclered rows 12" o.c. in field.
Roof deck to be 19/32 COX plywood nailed to
trusses with 8d x 2.5" long ring shank nails per sheeting
attachment detail on roof plan
Max allowable uplift = 85.8 psf
12
4 SLOP
W—I" T.O.B.
2" 12° 12QLI
H. H
O
O'-O" = Finished Floor
Finish Columns with 5/8" thick light textured
5/8" thick cut coral stucco on typical concrete
finished stucco bands block construction
REAR ELEVATION
�L�V�TIO�I
I�OT�S:
- Overhangs at
!'-O"
unless otherwise noted
on Roof Plan
- Roof pitch et
4:12 unless otherwise noted
Union Corrugating Co. 26 5V crimp metal roofing
— Any changes
t0 this
plan Shall be submitted
to the architect
ga.
FLUwood crews211A Attach roofing to deck using 49 x 1.F
wood screws with washer Per Approval over 30 lb Felt
for a rovaI
p p
in writing
g
prior to startle construction.
p g
underlayment installed with min. 4" side laps
and 6" end laps fastened with corrosion resistant tin
— Return A L L Stucco
Bands Into Window or
D oor. .
caps with 1 1/4" ring shank nails spaced 6" o.c.
at all laps and two stagggered rows 12" o.c. in field.
ROOF deck to be 19/32 CDX plywood nailed to
trusses with 8d x 2.5" long ring shank nails per sheeting
attachment detail on roof plan
Max allowable uplift = 85.8 psf
12
12
4 1 SLOPE
4 15LOPE
SCALE: 1/4" = I'-O"
Union Corrugating Co. 26 ga. 5V crimp metal roofing
FLU: 1211.4 Attach roofing to deck using #9 x 1.5"
wood screws with washer Per Approval over 30 lb felt
underlayment instailed with min. 4" side laps
and 6" end laps fastened with corrosion resistant tin
caps with 1 1/1" ring sfiank Wads spaced
at all laps and two sta99�ered rows 12" o.c. in field.
Roof deck to be 19/32 COX plywood nailed to
trusses with ed x 2.5" long ring shank nails per sheeting
attachment detail on roof plan
Max allowable uplift = 85.8 psf
r4 M
�I�
TEfi Ni ft I htAl micro I htULl
C3 AM FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBIOOF THE
COKfRA= IF FAM
i
ALL MANUFACTURES LABLES SHOWING
U FACTORS AND SHOC COMPLIANCE
WITH FBC ENERGY CODE MUST
REMAIN ON ALL DOORS AND WINDOWS
UNjIL INSPECTIONS ARE APPROVED
5/8" thick x 8% cut
coral finished stucco bands
THESE PANS AND ALL PROPOSED WORK
CW ARE $BJECT TO ANY CORRECTIONS
REQUIF ED BY FIELD INSPECTORS THAT
MAYBE NECESSART11N ORDER TO
COWL WITH ALG APPLICABLE CODES'
4110 k - 05os
ST. LIiCTf _0LiNTY RT.'IT n>1;f DIVISION
REVIBFUR YIP v. `CI
RisVIEt U I�Y � d
DATE
PLANS AN PERYIIT MUST BE KEPT ON JOE
0n NO LNSJECT10N WILL BE NLu, E.
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using ed nails. Substrate
to be 19/32" COX Plgwood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12„ H
®®®® 2„
8'—I" T.O.B.
H.
12" 2�
H" ❑ 5/8" thick x 8"w cut . ; 5/8" thick x 8 w cut ®®®
coral finished stucco bands coral finished stucco bands ®®� ® ® ®O
3 3NZ thick x 8„
u
coral finished stucco ban
5/8" thick light textured
stucco on typical concrete
block construction
/'�Garacai Finished Floor
- -ti -4 A.F.F. 5/8" thick light textured Finish Columns with
= Finished Floor — — — — — — — — — — — 5/8" thick cut coral
stucco on typical concrete block construction finished stucco bands
LEFT ELEVATION FRONT ELEVATION
SCALE: 1/4"
SCALE: 1/4" = 1'-0"
2" x 4" top plate 1I ' 1/2" drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at IC o.c.
base —board II II / 2 x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh
OR
CxC #10/10 WWM on 6 mil Visqueen
over
clean compacted termite treated
fill
Interior
Non -Bearing Partition
nts
Braden it Braden AIA, PA
Wgnne Building
Corp.
Architects - Planners
411 S.E. Coconut Avenue
Carlton 2
°I
Tel (7�2) 281-8258
Fax ('772) 28�1-8283
Spanish Lakes
E-mall: bradenaia comcast. net
St. Lucie County Florida
Stuart. FL 34994 #AACOOOOS2
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR 1=ROI"l THAT DATE
PERMITTING INFORMATION (FORM 100)
Norida Bwidrng Code Residential: 5th Edition and ASCE 1-10 for Wind Loading
Buildina Design is: Enclosed Risk Categorg: II Wind Velocity: 165 mph ultimate
Mean Roof Height: II'-O" Roof Pitch: 4:12
Internal Pressure Co-ee r}—cient: ±O-I8
SubAectabilitg to damage from: Weathering: Negligible Termites: Vero Heavu
Width of Roof End Zone: " Wind Speed: 165 mph ultimate
Wind Exposure Classification: C
Adjustment factor for Exposure Height: 1.21 x 0.6 = 0.126 ASO desiggn
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+0.6WL; O.6DL+0.6WL
Components t Cladding Wind Pressure (NET) Roof Zone. 1. +20.6/-32.6 psf
Roof Zone: 2. +20.6/-51.0 psf
Roof Zone: 3. +20.6/-84.0 psf
Components t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4.+35.8/-38.1 psf
Wall Zone: 5. +35.8/-41.8 paf
Componenta t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3oaf
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? Yes
Are Components an Cladding Det-ate Provided? Yes
Minimum Sol Bearing Pressure:2.500 par. Presumptive: X By Teat: psi
This Buildirg Shall Have the Following:
APPROVED SHATTERS: X IMPACT GLASS: BOTH: NEITHER:
ROOF LIVE LOAD: _31 psf ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: —'i5 psf FLOOR DEAD LOAD 10 psf
.IT2-12
CH
= Roof Zone I
Walla Zone 4
EH = Roof Zone 2
Walls Zone 5
END ZONE
= Corner Zones
Roof Zone 3
JOB ADDRESS:
Date Drawn Revisions Sheet Comm #
12-8-16
GARAGE Drawn by:
LEFT 1
c.c.u.
Checked by:
D.R-B. OF 5