Loading...
HomeMy WebLinkAboutA2P0048A_A and E_CDs_External REV DATE DESCRIPTION A 10/05/20 PRELIM PLANS ATC WOODCREST 0 10/12/20 FINAL PLANS ISSUED 14101 SOUTH ANGLE ROAD bile WEST ST. LUCIE, FLORIDA 34945 ■ ■ ■ ■ O ■® (ST. LUCIE COUNTY) PROJECT NO.: 17-5053.1 DRAWN BY: M.THOMAS PROJECT MANAGER: D. REVELS t l e e ® A2POO48A CHECKED BY: D. REVELS s k tog th rTHIS DRAWING IS COPYRIGHTED AND IS A M E R I CA N TOWER IT IS PRODUCEDOWNER RHE SOLE SO PROPERTY �FOR AFFILIATES. THE ATC SITE NAME/#: ANGLE ROAD / FL-51 10 OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN NATIONAL HARDENING PROJECT IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. PROPOSED GENERATOR INSTALLATION AND POWER UPGRADE RkAlm LOCAL MAP PROPERTY SUMMARY PROJECT DESCRIPTION INDEX OF DRAWINGS 0 GROUP, INC TOGETHER PLANNINR A RRT--RR TOMORROW �a _ FOLIO 1. THE WIRELESS COMMUNICATIONS FACILITY IS NOT INTENDED. •:-a _•s,- ;, SHT. DESCRIPTION REV. p 1332-21 1-0002-000-5 FOR HUMAN OCCUPANCY. NO. NO. 13051 TELECOM PARKWAY, SUITE 100 Lakewood Park TEMPLE TERRACE, FLORIDA 33637 = T1 TITLE SHEET 0 (813) sis-razz 2. THIS FACILITY DOES NOT REQUIRE POTABLE WATER AND WILL \T14 _ PROPERTY OWNER NOT PRODUCE ANY SEWAGE. T2 NOTES 0 CERTIFICATE OR AUTHORIZATION 28767 « d,a INDRIO HOLDINGS LLC 3. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING C1 SITE PLAN 0 1626 90TH AVENUE DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL C2 SET BACK DETAIL 0 - VERO BEACH, FLORIDA 32966 IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE C3 ENLARGED SITE PLAN 0 RESPONSIBLE FOR SAME. T Mobile = c LATITUDE C4 GENERATOR DETAILS (1 OF 2) 0 ■ ■ OC1C 27.47087675 N 4. THE SCOPE OF WORK CONSISTS OF THE FOLLOWING: ' C5 GENERATOR DETAILS (2 OF 2) 0 Stick t0gether® SITE LOCATION�� A INSTALLATION OF (1) PROPOSED 25KW DIESEL GENERATOR C6 FOUNDATION DETIALS 0 LONGITUDE INSTALLATION OF (1) PROPOSED 200A. PPC ENCLOSURE oo coSUNORISE, FL 333z3 SUITE zoo s I E1 ELECTRICAL NOTES 0 o.agenv. _a oa„ge n. ' U ` ' ` ,-- d ' For -80.45106 W INSTALLATION OF (1) PROPOSED 200A. UTILITY METER — INSTALLATION OF (1) PROPOSED 200A. SERVICE DISCONNECT E2 GROUNDING NOTES 0 - ZONING JURISDICTION E3 ENLARGED CONDUIT ROUTING PLAN 0 E4 ONE-LINE AND PANEL SCHEDULE 0 g ST. LUCIE COUNTY :as ewe en a E5 GROUNDING PLAN 0 ``��� D• ///// E6 GROUNDING DETAILS 0 \���M ����,»•••••••• //// s 0 n � �� tv`N:��GENS�•.•.�j► wMudnay.Rd lv; No. 751 •' Ibd �y VICINITY MAP DESIGN CRITERIA CODE COMPLIANCE i tv wgdd•u„IIesrl­•FL DESIGN WIND SPEED: 155 MPH (ULTIMATE 3-SEC GUST) ALL WORK AND MATERIALS SHALL BE PERFORMED AND Q •.,•• STATE OF 120 MPH (NOMINAL 3-SEC GUST) INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF / • F40R�QP..+����\\\ EXPOSURE CATEGORY: C THE FOLLOWING CODES AS ADOPTED BY THE LOCAL // S••• ••••....»..�•aG ``\\ N RISK CATEGORY: II GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE S�oA'p 1 `` i 2�2 CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE // 4AL CODES. JEREMY D. SHARIT PE FL LIC 75137 1. FLORIDA BUILDING CODE, 6TH EDITION (2017) 2. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70, NATIONAL ELECTRICAL CODE, 2014 EDITION. o, 3. TIA-222-G WITH ADDENDUM 1 AND 2 APPLICABLE ATC WOODCREST STANDARDS. fl 4. LIFE SAFETY CODE NFPA-101-2015. 5. FLORIDA FIRE PREVENTION CODE, 6TH EDITION. AZPOO48—A CONTACTS SITE LOCATION 6. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) wAy�xa 360-10 AND 341-10. 14101 SOUTH ANGLE ROAD w A+y@ Rd W A,gI,Rd T-MOBILE SOUTH LLC 7. UNDERWRITERS LABORATORIES (U.L.) WEST (S LUCIE,r. LUCIE ouNl COUNry) FLORIDA 34945 �\ 1300 CONCORD TERRACE SUITE 200 APPROVED ELECTRICAL PRODUCTS. (s \ SUNRISE, FL 33323 8. LOCAL JURISDICTIONAL REQUIREMENTS. SHEET NAME s \` 9. CITY/COUNTY ORDINANCES. V TITLE SHEET SMW ENGINEERING GROUP. INC. PM: SHEET NUMBER DARREN REVELS (813) 503-0218 T 1 7�D�frPt 25{1 m REV DATE DESCRIPTION 1. THE APPROPRIATE UTILITY LOCATING SERVICES SHALL BE CONTACTED PRIOR TO THE START OF CONSTRUCTION IN ORDER TO VERIFY THE EXACT LOCATION OF ALL A 10/05/20 PRELIM PLANS 1. FOR THE PURPOSES OF THESE CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL APPLY: EXISTING UNDERGROUND UTILITIES. 0 10/12/20 FINAL PLANS ISSUED 2. THE INSTALLATION OF NEW UTILITIES SHALL BE COORDINATED WITH LOCAL AUTHORITIES. OWNER - T-MOBILE SOUTH LLC 3. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES. WHERE ENGINEER - SMW ENGINEERING GROUP, INC. REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SUCH UTILITIES SHALL BE RELOCATED AS DIRECTED BY THE CONSTRUCTION MANAGER. EXTREME CAUTION CONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) SHALL BE USED WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. 4. RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 2. PRIOR TO SUBMITTING HIS BID, THE CONTRACTOR SHALL VISIT THE JOB SITE IN ORDER TO (1) VERIFY ALL 5. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES THAT INTERFERE WITH THE EXECUTION OF THE WORK SHALL BE REMOVED AND/OR PROJECT NO.: 17-5053.1 EXISTING CONDITIONS, (2) CONFIRM WHETHER ALL DIMENSIONS ARE AS SHOWN ON THE PLANS AND (3) CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS THAT WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF THE CONFIRM WHETHER THE WORK MAY BE ACCOMPLISHED AS SHOWN. ANY DISCREPANCIES SHALL BE BROUGHT LANDLORD AND/OR LOCAL UTILITIES. DRAWN BY: M. THOMAS TO THE ATTENTION OF THE CONSTRUCTION MANAGER. PROJECT MANAGER: D. REVELS 6. DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION SHALL BE MINIMIZED. 3. A 20-FOOT HORIZONTAL CLEARANCE DISTANCE SHALL BE MAINTAINED FROM ALL EXISTING POWER LINES. CHECKED BY: D. REVELS 7. ANY AREAS OF THE CONSTRUCTION SITE DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A THIS DRAWING IS COPYRIGHTED AND IS 4. THE CONTRACTOR'S USE OF A CONSTRUCTION STAGING AREA SHALL BE COORDINATED WITH THE OWNER WELL UNIFORM SLOPE. SUCH GRADING SHALL CAUSE SURFACE WATER TO FLOW AWAY FROM ANY EQUIPMENT SHELTER AND TOWER AREAS AND THE SOIL SHALL BE THE SOLE PROPERTY OF THE OWNER. IT IN ADVANCE OF THE CONSTRUCTION START DATE. STABILIZED TO PREVENT EROSION. EROSION CONTROL MEASURES,IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES IS PRODUCED SOLELY FOR USE BY THE FOR EROSION AND SEDIMENT CONTROL. OWNER AND ITS AFFILIATES. 5. LABOR, MATERIAL, TOOLS, EQUIPMENT, TRANSPORTATION AND TEMPORARY POWER SERVICES NECESSARY FOR REPRODUCTION OR USE OF THIS DRAWING AND INCIDENTAL TO COMPLETION OF ALL WORK SHALL BE PROVIDED AS INDICATED ON THE DRAWINGS 8. THE SUB-GRADE SHALL BE COMPACTED AND BROUGHT TO A UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN AND/OR AS SPECIFIED HEREIN. LABOR AND MATERIALS SHALL BE FURNISHED AS REQUIRED FOR COMPLETE PERMISSION OF THE OWNER. SYSTEMS, INCLUDING ALL ELEMENTS OBVIOUSLY OR REASONABLY INCIDENTAL TO A COMPLETE INSTALLATION, 9• BACKFILL SHALL CONSIST OF CLEAN SAND FILL APPROVED FOR USE BY THE ENGINEER. NO UNAPPROVED MATERIAL WILL BE ALLOWED. CLEAN SAND FILL SHALL BE WHETHER OR NOT SPECIFICALLY INDICATED ON THE PLANS. FREE OF ALL ROOTS, BOULDERS, OR OTHER DELETERIOUS MATERIAL. 6. FOR TASKS REQUIRED TO BE PERFORMED BUT NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT 10. THE CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO EQUAL TO OR BETTER CONDITION THAN ORIGINAL. DOCUMENTS, THE CONTRACTOR SHALL NOT START WORK ON SUCH TASKS WITHOUT HAVING RECEIVED WRITTEN AUTHORIZATION FROM THE CONSTRUCTION MANAGER TO PROCEED. 11. SITE SIGNAGE SHALL BE PROVIDED IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS FOR SUCH SIGNAGE AS MAY BE CONTAINED IN THESE DRAWINGS. 7. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND EQUIPMENT �N@ N�€�R 0 GROUP, INC � UNLESS OTHERWISE INDICATED BY DIMENSIONS OR DETAILS. EXACT EQUIPMENT LOCATIONS MAY BE MODIFIED SITE WORK NOTES 2 q AS REQUIRED BY ACTUAL FIELD CONDITIONS. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE 13051 TELECOM PARKWAY, SUITE 100 ENGINEER AND THE CONSTRUCTION MANAGER. 1. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE LATEST EDITION OF THE AISC "STEEL CONSTRUCTION MANUAL". TEMPLE TERRACE(813) 615-142222, 0A 33637 8. THE CONTRACTOR SHALL OBTAIN, PAY FOR AND DELIVER ALL REQUIRED PERMITS, CERTIFICATES OF cERnPICArE oP Au HORlznnon 2e7s� INSPECTION, INCLUDING UTILITY CONNECTION FEES, ETC., REQUIRED BY THE AUTHORITIES HAVING 2. MATERIAL: JURISDICTION AND SHALL DELIVER SUCH DOCUMENTS TO THE OWNER PRIOR TO FINAL ACCEPTANCE OF THE A. ALL STRUCTURAL STEEL WF BEAMS SHALL BE ASTM A992 AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM A153 STANDARDS. WORK. B. ALL STRUCTURAL PLATES, ANGLES, AND CHANNELS SHALL BE ASTM A36 AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM A153 STANDARDS, UNLESS NOTED OTHERWISE. 9. THE CONTRACTOR'S OPERATIONS SHALL BE CONFINED TO AREAS OF NEW CONSTRUCTION. C. ALL TS MEMBERS SHALL BE ASTM A500 GRADE B (Fy=46ksi), AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM A153 STANDARDS. 10. ALL NECESSARY PROVISIONS SHALL BE MADE TO PROTECT EXISTING IMPROVEMENTS, LANDSCAPING, PAVING, D. ALL STRUCTURAL PIPE MEMBERS SHALL BE ASTM A500 GRADE B (Fy=42ksi), AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM 'i' • -Mobile• CURBS, GALVANIZED SURFACES, ETC, AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO A153 STANDARDS, UNLESS NOTED OTHERWISE SAME RESULTING FROM THE CONSTRUCTION WORK. ALL DISTURBED AND DAMAGED AREAS SHALL BE E. ALL NON-STRUCTURAL PIPE MEMBERS SHALL BE ASTM A53 GRADE B, AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM A153 stick together' RESTORED TO THEIR ORIGINAL CONDITION OR BETTER UPON COMPLETION OF ALL WORK TO THE SATISFACTION STANDARDS. OF THE CONSTRUCTION MANAGER. 1300 CONCORD E TERRACE32 SUITE zoo 2. DESIGN, FABRICATION, AND CONSTRUCTION OF ALL CONNECTIONS SHALL CONFORM TO AISC STEEL CONSTRUCTION MANUAL. 11. THE FOLLOWING CLEANUP TASKS SHALL BE PERFORMED AS FOLLOWS: (1) ON A DAILY BASIS, KEEP THE GENERAL AREA CLEAN AND HAZARD FREE, REMOVING ALL WASTE, DEBRIS AND TRASH FROM THE SITE AND 3. WELDING: DISPOSING OF SAME IN A LEGAL MANNER. (2) UPON COMPLETION, LEAVE THE PREMISES IN A CLEAN A. ALL WELDS, WELDERS, AND WELD INSPECTIONS SHALL CONFORM TO THE REQUIREMENTS OF AWS D 1.1, LATEST REVISION. CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. B. ALL WELDS SHALL BE MADE WITH E70XX LOW HYDROGEN ELECTRODES. C. ALL STEEL SHALL BE SPRAY GALVANIZED AFTER WELDING. 12 ALL MANUFACTURER'S RECOMMENDATIONS EXCEPT UIPMENT AND MATERIALS SHALL E INSTALL IS SPECIFICALLY D IN AINDICA NCE WITH H OTHERWISE RESPECTIVETHE NTE 4. ALL BOLTS SHALL BE GALVANIZED %" DIAMETER, A325-N, UNLESS NOTED OTHERWISE AND TIGHTENED TO A "SNUG TIGHT' CONDITION AS DEFINED BY AISC. SECURE NUT WITH LOCKING WASHER. CONTRACT DOCUMENTS OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. ���` t-.•'�����•••E111 13. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL 5. THE CONTRACTOR/STEEL FABRICATOR SHALL LOCATE ANY REINFORCEMENT IN THE STRUCTURAL MEMBERS IN SUCH A MANNER SO THAT THERE WILL NOT BE = NO. 751 LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY HAVING CONFLICT WITH THE REINFORCEMENT WHEN INSTALLING ANCHORS. THE ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTION. JURISDICTION OVER THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE 6. THE CONTRACTOR/STEEL FABRICATOR SHALL CONFORM TO THE MINIMUM EDGE DISTANCE REQUIREMENTS IN ACCORDANCE WITH THE AISC MANUAL OF STEEL i e INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AS WELL CONSTRUCTION. s AS LOCAL AND STATE CODES, ORDINANCES AND APPLICABLE REGULATIONS. 0. tea STATE OF 14. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AT ALL TIMES, USING THE BEST SKILLS AND 7. ALL STRUCTURAL STEEL SHALL BE FABRICATED TO FIT AT BOLTED CONNECTIONS WITHIN 1/16 INCH TOLERANCE. STRUCTURAL STEEL SHALL NOT BE FLAME CUT i� . •'���� EA UNDER ANY CIRCUMSTANCES WITHOUT APPROVAL OF THE ENGINEER. �ORI ��r ATTENTION. HE SHALL BE SOLELY RESPONSIBLE FOR ALL OF THE CONSTRUCTION MEANS, METHODS, i s�i..............•�`_ NECLUDIQU NGESCONTQCT NAND COORDINATION AND URES W TH ATHE FCONSTROCDIONTINMANAGER G ALL PANDIONS WITH OF THE THE OWN OR S 8. THE CONTRACTOR/STEEL FABRICATOR SHALL CAP OR SEAL ALL PIPES AS REQUIRED TO PREVENT WATER INTRUSION. /// �NAI-�1�.or �Z�Z UTE AUTHORIZED REPRESENTATIVE. 9. THE CONTRACTOR/STEEL FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO ANY STEEL FABRICATION. AT THE CONTRACTOR'S OPTION, FIELD / SPLICES MAY BE USED FOR ERECTION PURPOSES. IF FIELD SPLICES ARE USED, THE SHOP DRAWINGS SHALL INCLUDE ALL DETAILS FOR THE PROPOSED FIELD JEREMY D. SHAR11 PE FL LIC 75137 15. WITHIN TEN (10) WORKING DAYS AFTER PROJECT COMPLETION, THE CONTRACTOR SHALL PROVIDE A SPLICES. COMPLETE SET OF AS-BUILT DRAWINGS, SWEEP TEST, CYLINDER TESTS, LIEN RELEASES, AND OTHER CLOSEOUT DOCUMENTATION AS REQUIRED BY THE OWNER. ALL SYSTEMS SHALL BE COMPLETELY ASSEMBLED, 10. AT THE CONTRACTOR'S OPTION, SHOP WELDS MAY BE USED INSTEAD OF FIELD WELDS. TESTED, ADJUSTED AND DEMONSTRATED TO BE READY FOR OPERATION PRIOR TO THE OWNER'S ACCEPTANCE. ATC WOODCREST 11. SUBMIT ORIGINAL SHOP DRAWINGS, INCLUDING COMPLETE DETAILS, SCHEDULES OF FABRICATION AND ASSEMBLY, PROCEDURES, AND DIAGRAMS. INCLUDE DETAILS OF CUTS, CONNECTIONS, CAMBER, HOLE, AND OTHER PERTINENT DATA. INDICATE WELDS BY STANDARD AWS A2.1 AND A2.4 SYMBOLS, AND SHOW SIZE, LENGTH, AND TYPE OF WELD. PROVIDE SETTING DRAWINGS, TEMPLATES, AND DIRECTIONS FOR INSTALLATION OF ANCHOR BOLTS AND OTHER ANCHORAGES TO BE INSTALLED A2P0048-A AS WORK OF OTHERS' SECTIONS. 14101 SOUTH ANGLE ROAD WEST ST. LUCIE, FLORIDA 34945 (ST. LUCIE COUNTY) SHEET NAME NOTES SHEET NUMBER GENERAL NOTES F, STRUCTURAL STEEL NOTES 3 T2 8 0' 4' 8' REV DATE DESCRIPTION A 10/05/20 PRELIM PLANS FOR 24"06" DRAWINGS 0 10/12/20 FINAL PLANS ISSUED GRAPHIC SCALE: 1/4" = 1'-0" a FOR 11"x17" DRAWINGS GRAPHIC SCALE: 1/8" = 1'-0" PROJECT NO.: 17-5053.1 (till❑v-) EXISTING EQUIPMENT SHELTER EXISTING ACCESS DRAWN BY: M. THOMAS GATE PROJECT MANAGER: D. REVELS CHECKED BY: D. REVELS I THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT x IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERM SSION OF THE OWNER. X x EXISTING T—MOBILE UTILITY H—FRAME �NOIN€�RI10 GROUP, INC. x ° d X TOQFRTNRR 1'kANNSN®A RRTTRR TII 1m ]% kt tlw d EXISTING T—MOBILE 10OA. UTILITY METER & SERVICE a DISCONNECT (BELOW) I' osi TELECOM PARKWAY, SUITE 00 TEMPLE TERRACE, FLORIDA 33637 TO BE REMOVED is (813) 615-1422 CERTIFICATE OF AUTHORIZATION 28767 EXISTING 300' SELF—SUPPORT %/ I EXISTING T—MOBILE X TOWER '� GENERATOR AND BELLY TANK TO BE REMOVED EXISTING T—MOBILE 100A. T ELECTRICAL PANEL -Mobile TO BE REMOVED x X stick together' 1300 CONCORD TERRACE SUITE 2D0 SUNRISE, FL 33323 >�EXISTING CONCRETE EXISTING CONCRETE GENERATOR PAD X X EQUIPMENT PAD x T-11 d S a 2 X X STATE OF J-k/ //�S•••h•NwwwaNN �/ �� EXISTING CONCRETE EXISTING WAVEGUIDE GENERATOR PAD x BRIDGE (TYP.) X JEREMY D. SHARIT PE FL LIC 75137 a/ ATC WOODCREST x x `R\\ A2 P0048—A EXISTING EQUIPMENT 14101 SOUTH ANGLE ROAD SHELTER WEST ST LUCIE, FLORIDA LUCIE COUNTY) EXISTING PROPANE TANK ON CONCRETE PAD X X NOTE: SHEEP NAME INFORMATION FOR COMPOUND DETAIL TAKEN FROM INFORMATION PROVIDED EXISTING BY T—MOBILE AND A SITE WALK PERFORMED BY SMW ENGINEERING SITE PLAN X X X X X X GROUP, INC. ON 07-24-2020. SHEET NUMBER EXISTING SITE PLAN SCALED AS NOTED C1 16' 0' 8' 16' REV DATE DESCRIPTION A 10/05/20 PRELIM PLANS FOR 24"06" DRAWINGS 0 10/12/20 FINAL PLANS ISSUED GRAPHIC SCALE: 1/8" = 1'-0" a FOR 11"x17" DRAWINGS FLOOD NOTE: GRAPHIC SCALE: 1/16" = 1'-0" THE SUBJECT PROPERTY APPEARS TO BE WITHIN FLOOD ZONE "X" PER FIRM MAP NUMBER 12111CO155J W/ AN EFFECTIVE DATE OF 09/11/2009. PROJECT NO.: 17-5053.1 (till❑v-) EXISTING EQUIPMENT SHELTER EXISTING ACCESS DRAWN BY: M. THOMAS GATE PROJECT MANAGER: D. REVELS CHECKED BY: D. REVELS I THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT x IS PRODUCED SOLELY FOR USE BY THE L-TyOWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PROPOSED T-MOBILE EMERGENCY PERMSSION OF THE OWNER. GENERATOR SHUT-OFF SWITCH TO BE INSTALLED ON EXISTING H-FRAME x EXISTING T-MOBILE UTILITY H-FRAME �NOIN€�RI10 GROUP, INC: x ° x TOQFFTNIRR>A>EAN1i5it®A»@TT@R T@MARR®tl6 d d PROPOSED T-MOBILE 200A., 120/24OV, 10 UTILITY METER & ° I 13051 TELECOM PARKWAY, SUITE 100 SERVICE DISCONNECT (BELOW) TO BE TEMPLE TERRACE, FLORIDA 33637 INSTALLED ON EXISTING H-FRAME e13) s15-lazz CERTIFICATE OF AUTHORIZATION 28767 EXISTING 300' SELF-SUPPORT / PROPOSED T-MOBILE x TOWER ° 25KW DIESEL GENERATOR ON PROPOSED 4'x9' CONCRETE PAD PROPOSED T-MOBILE 200A. o� T ELECTRICAL PANEL -Mobile EXISTING TO BE INSTALLED ON x X EXISTING T-MOBILE H-FRAME stick together' 130000NCORD TERRACE SUITE 2D0 �X SUNRISE, FL 33323 EXISTING CONCRETE EXISTING CONCRETE x EQUIPMENT PAD GENERATOR PAD � d S a 2 x T-11 x Xx>< � F x x 0 STATE OF J-k/ ORI //�S•••h•NwwwwNN �/ �� EXISTING CONCRETE EXISTING WAVEGUIDE //�O'` 1 � 2 2 GENERATOR PAD x BRIDGE (TYP.) x �����11111� / JEREMY D. SHARIT PE F1 LIC 75137 a� ATC WOODCREST x x `R\\ A2 P0048—A EXISTING EQUIPMENT 14101 SOUTH ANGLE ROAD SHELTER WEST ST LUCIE, FLORIDA LUCIE COUNTY) EXISTING PROPANE TANK ON CONCRETE PAD X X NOTE: SHEEP NAME INFORMATION FOR COMPOUND DETAIL TAKEN FROM INFORMATION PROVIDED PROPOSED BY T-MOBILE AND A SITE WALK PERFORMED BY SMW ENGINEERING SITE PLAN x X x x x x GROUP, INC. ON 07-24-2020. SHEET NUMBER PROPOSED SITE PLAN SCALED AS NOTED C2 128' 0' 64' 128 REV DATE DESCRIPTION A 10/05/20 PRELIM PLANS FOR 24"06" DRAWINGS 0 10/12/20 FINAL PLANS ISSUED GRAPHIC SCALE: 1/64" = 1'-0" FOR 11"x17" DRAWINGS GRAPHIC SCALE: 1/128" = 1'-0" I PROJECT NO.: 17-5053.1 DRAWN BY: M. THOMAS PROJECT MANAGER: D. REVELS CHECKED BY: D. REVELS THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. �NOIN€�RI 10 GROUP, INC: RQF3�.'T#1@R IPIANNSN®A»@TT@R TII Mm%RR®tl6 I 13051 TELECOM PARKWAY, SUITE 100 OPEN FIELD TEMPLE TERRACE, FLORIDA 33637 (813) 615-1422 CERTIFICATE OF AUTHORIZATION 28767 T - -Mobile stick together' 130000NCORD TERRACE SUITE 2D0 SUNRISE, FL 33323 I _• No. 751 EXISTING 300' SELF—SUPPORT s TOWERice e % STATE OF ,.••.4 EXISTING FENCED TELECOMMUNICATION t762' °a.1/C4 OP�:'� ` FACILITY ° OR•``°°•N \\ �NAL . 10 i 2/2 JEREMY D. SHARIT PE FL LIC 75137 I 0 ATC WOODCREST A2P0048—A EXISTING PROPERTY BOUNDARY LINE 14101 SOUTH ANGLE ROAD WEST ST. LUCIE, FLORIDA 34945 - - - (ST. LUCIE COUNTY) SHEET NAME SET BACK D ETAI L SHEET NUMBER GENERATOR SETBACK DETAIL SCALED AS NOTED 03 2' 0' 1' 'REV DATE DESCRIPTION A 10/05/20 PRELIM PLANS FOR 24"x36" DRAWINGS O 10/12/20 FINAL PLANS ISSUED GRAPHIC SCALE: 1" = 1'-0" FOR 1 1%17" DRAWINGS NOTES: 103.4" GRAPHIC SCALE: 1/2" = 1'-0" 1. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 2. BATTERY (12 VOLT NEGATIVE GROUND SYSTEM). 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - MAIN LINE CIRCUIT BREAKER 125 AMPS - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. - CONTROL PANEL PROJECT NO.: 17-5053.1 INCLUDES INTEGRATED BATTERY CHARGER O 0 NOTE: 4. REMOVE THE REAR STUB-UP AND REAR ENCLOSURE COVER PANEL TO ACCESS THE DRAWN BY: M. THOMAS STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD 1. RUPTURE BASIN ALARM IS TIED TO PROJECT MANAGER: D. REVELS CONDUIT CONNECTION, NEUTRAL CONNECTION, AND BATTERY CHARGER 120 VOLT AC (0.5 O ALARM PANEL IN GENERATOR. THE AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH ® PROPOSED 25KW O ALARM PANEL WILL NOTIFY T-MOBILE CHECKED BY: D. REVELS CONTROL WIRES DIESEL GENERATOR Ln NETWORK OPERATIONS CENTER VIA 5. ENGINE SERVICE CONNECTIONS OIL DRAIN: 1/2" NPT RADIATOR DRAIN : HOSE CLAMPED TO GENERATOR'S REMOTE ENUNCIATOR THIS DRAWING IS COPYRIGHTED AND IS / THE SOLE PROPERTY OF THE OWNER. IT FRAME PANE IN THE EVENT OF A LEAK. IS PRODUCED SOLELY FOR USE BY THE 6. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. OWNER AND ITS AFFILIATES. 7. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND 2. ALARM WILL SOUND WHEN FUEL LEVEL REPRODUCTION OR USE OF THIS DRAWING RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. IS AT 90% DURING RE-FUELING. ANDISOFORHEo NF RMATIOWITHOUT CONTAINED N 8. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 3. NFPA 704 PLACARD TO BE UTILIZED ON PERMISSION OF THE OWNER. 9. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE THE FUEL TANK. STANDARD SAE TORQUE SPECS) 10. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 11. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. RECOMMENDED MINIMUM PERIMETER(3FT) AND VERTICAL OVER EXHAUST (5FT) CLEARANCE FOR SITE LOCATION. N @ I N€ R I 10 GROUP, 1 N C: 12. GENERATOR MUST BE GROUNDED. RQF3>r.'T#1@R>A>6AN1i1it®A»@'1`I''@R i'@MARR®tl6 GENERATOR PLAN VIEW SCALED AS NOTED 13051 TELECOM PARKWAY, SITE 100 TEMPLE TERRACE, FLORIDA 33637 2' 0' 1' 2' 2' 0' 1' 2' (813) 615-1422 CERTIFICATE OF AUTHORIZATION 28767 FOR 24"06" DRAWINGS FOR 24"06" DRAWINGS GRAPHIC SCALE: 1" = 1'-0" GRAPHIC SCALE: 1" = 1'-0" FOR 11"07" DRAWINGS FOR 11"07" DRAWINGS GRAPHIC SCALE: 1/2" = 1'-0" GRAPHIC SCALE: 1/2" = 1'-0" 33.5" PROPOSED VINYL NFPA 704 PLACARD 84.2" T - -Mobile NOTE: FOR DIESEL TO BE PLACED ON stick together' ALARM WILL SOUND DIESEL TANK IN A LOCATION EASILY WHEN FUEL LEVEL VISIBLE TO EMERGENCY PERSONNEL gg������ ������ � �@ 1300 CONCORD TERRACE SUITE zoo g IS AT 90% DURING - - SUNRISE, FL 33323 __RE-FUELING GENERATOR CONTROL \25KW DIESEL- ALARM PANEL 0 \GENERATOR (LOCATION OF REMOTE ��� ••.•••'••••N••••"••.•, /// ANNUNCIATOR) _Efl �� •• •% / . �ti,••• �G NSF �.�j► 25KW DIESEL DIESEL FUEL GENERATOR ®NO SMOKING i iVO. 751 ®NO OPEN FLAMES \ o I� S x O) • : CC n � STATE OF 'tv 44NAL%11 '� i 2/2 p JEREMY D. SHARIT PE FL LIC 75137 00 q GENERATOR r^i BASETANK �� I J ATC WOODCREST GENERATOR BASETANK A2 P0048—A 14101 SOUTH ANGLE ROAD WEST ST. LUCIE, FLORIDA 34945 (ST. LUCIE COUNTY) 4.3" 18.9" 25.2" 25.1" 25,2 3.9" SHEET NAME .73 rf 73,• _� I� r �i 35.0" GENERATOR DETAILS (1 OF 2) SHEET NUMBER GENERATOR END VIEW SCALED AS NOTED 2 GENERATOR SIDE VIEW NTS 3 04 REV DATE DESCRIPTION A 10/05/20 PRELIM PLANS NOTES: 0 10/12/20 FINAL PLANS ISSUED 1. DIESEL BASE TANK IS DOUBLE WALLED NOTE: 2. RUPTURE BASIN ALARM IS TIED FUEL LEVEL GAUGE/SENDER IS A TO ALARM PANEL IN VISIBLE GAUGE THAT HAS A REMOTE GENERATOR. THE ALARM PANEL SENDER ATTACHED. WILL NOTIFY T-MOBILE NETWORK OPERATIONS CENTER IN THE EVENT OF A LEAK. PROJECT NO.: 17-5053.1 DRAWN BY: M. THOMAS 2271 [89.41 PROJECT MANAGER: D. REVELS TYP CHECKED BY: D. REVELS 259 [10.2] INNER TANK NORMAL VENT TYP (2"NPT FEMALE) THIS DRAWING IS COPYRIGHTED AND IS 132 ]5.2] INNER TANK EMERGENCY VENT CUSTOMER OPTIO OUTER TANK THE SOLE PROPERTY OF THE OWNER. IT (W NPT FEMALE) (2"NPT FEMALE) LEAK DETECTOR IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN OUTER TANK EMERGENCY VENT IT IS FORBIDDEN WITHOUT THE WRITTEN (3"NPT FEMALE) ' PERMISSION OF THE OWNER. o C FUEL TANK C� I TOTAL CAPACITY 908[240] U ° ° -HIGH AND LOW 718 [28.3] SABLE CAPACITY 867[229] FUEL FILL VOLTAGE 786 [30.91 CAPACITY:LITER[GALLON] T 1 (2"NPT FEMALE) o STUB-UP AREA DIMENSIONS:MM[INCH] N@ I N€ R I 10 GROUP, 1 N C: 661 126.01 125 [4.9] TANK IS LISTED TO UL142 AND ULC5601 RQF3�.'T#1@R>A>EAN1i5it®A�@'1`I''@R i'@MARR®tl6 533 [21.0] - - STUB-UP NOTE:STUB-UP AREA FOR HIGH AREA AND LOW VOLTAGE CONNECTIONS, 13051 TELECOM PARKWAY, SUITE 100 236 9.3 CIRCUIT BREAKER,NEUTRAL AND TEMPLE TERRACE, FLORIDA 33637 [ ] CUSTOMER CONNECTION OPENING. (813) 615-1422 CERTIFICATE OF AUTHORIZATION 28767 161[6.3] 38 [1.5] 246 [9.7] FUEL LEVEL FUEL RETUR 170 [6.7] 51 [2.0] GAUGE/SENDER 372 [14.6 FUEL SUPPLY 267 [10.5] 125 [4.9] TYP STUB-UP T - •Mobile 1497 [58.9] 62 [2.5] AREA AREA TYP -91 1569 [61.8 253 [10.0] 850 [33.5] stick together® TYP 1.4 2345 [92.31 1300 CONCORDUNRISETERRACE 33323 SUITE 200 TOP VIEW SPILL CONTAINMENT BOX REMOVABLE OVER SEE NOTE 1043 [41.11 _• No. 751 S t �O:, STATE OF ,.••'��� �01sss [ss] MTG HOLES (10 PLACES) // A•'05 4•OR��r`'•,�`'`\ SEE NOTE 92-- 1 F� 4 /�ti/11111111111'� . 12/2 19 [.7] 851 [33.51 JEREMY D. SHARIT PE FL LIC 75137 TYP MTG CENTERS TYP 888 [35.0] ATC WOODCREST REAR VIEW A2P0048-A 14101 SOUTH ANGLE ROAD 23.2" WEST ST. LUCIE, FLORIDA 34945 (ST. LUCIE COUNTY) 48.3" SHEET NAME 73.5" 98.7" GENERATOR DETAILS 102.6" (2 OF 2) SHEET NUMBER GENERATOR SIDE VIEW NTS C5 REV DATE DESCRIPTION A 10/05/20 PRELIM PLANS 0 10/12/20 FINAL PLANS ISSUED GENERATOR FUEL TANK PROJECT NO.: 17-5053.1 Y2"O HILTI KWIK BOLT WITH 3Y2" EMBED. DRAWN BY: M. THOMAS BOLTS & HARDWARE ARE TO BE STAINLESS PROJECT MANAGER: D. REVELS STEEL CHECKED BY: D. REVELS THIS DRAWING IS COPYRIGHTED AND IS THE SOLE TY OFIT T/O CONCRETE PAD ISPRODUCEDOPER SOL L ORHUSEWNE BYTHE i OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN � PERMISSION OF THE OWNER. Ld m g' m W LIL hk�l Iq fN@IN€�RIN0 GROUP, INO: RQF3�.'T#1@R>A>EAN1i5it®A»@l`1f'@R i'@MARR®tl6 6" MINIMUM 13051 TELECOM PARKWAY, SUITE 100 EDGE DISTANCE TEMPLE TERRACE, FLORIDA 33637 (813) 615-1422 CERTIFICATE OF AUTHORIZATION 28767 GENERATOR ANCHORING DETAIL NTS T - -Mobile' stick together" NOTES: 1300 CONCORD TERRACE SUITE zoo 1. ALL CONCRETE TO HAVE A COMPRESSIVE STRENGTH OF SUNRISE, FL 33323 fc'=3000 PSI WITH COMMERCIAL GRADE FIBER MESH REINFORCEMENT 1.5# PER CU. YARD 2. CONCRETE PAD IS DESIGNED TO BEAR ON 2000 PSF SOIL BEARING CAPACITY TO BE VERIFIED AT TIME OF EXCAVATION BY A SOILS ENGINEER REGISTERED IN THE STATE OF FLORIDA. CONTRACTOR TO PROVIDE TO MDC \\\\\�� p• S1L�,��/�� SOIL STATEMENT ONCE SOIL BEARING CAPACITY HAS 4 / BEEN DETERMINED. ® `�\�`�••1'•��GEj�js••••.�• ,//i ° _• No. 751 #5 REBAR ® 12" O.C. BOTH s e DIRECTIONS (NOT REQUIRED oI • IF FIBERCRETE IS USED) Z, ••••�/ Y2" CHAMFER (TYP.) STATE OF •••ha••nn••••• 3,000 PSI CONCRETE PAD �����11111111111'�°0/12/2 JEREMY D. SHARIT PE FL LIC 75137 6 MIL MIRAFI POLYETHYLENE PLASTIC SHEET OR EQUAL ATC WOODCREST A2P0048—A 9 'a .° 14101 SOUTH ANGLE ROAD ° WEST ST. LUCIE, FLORIDA 34945 COMPACTED ITOT95%EOF �� � ��� � � °� ���� � �� � (sT. LucIE couNTY) MODIFIED PROCTOR DENSITY /V�����A�����A����������������������� �������� SHEET NAME NOTE: �p PER ASTM D1557 � � � � � � FOUNDATION CHOICE OF FIBERCRETE OR CONCRETE PAD TO BE MADE IN THE FIELD BY T—MOBILE DETAILS CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION. SHEET NUMBER ( GENERATOR PAD FOUNDATION DETAIL NTS 2 GENERATOR PAD FOUNDATION ELEVATION NTS 3 C6 REV DATE DESCRIPTION A 10/05/20 PRELIM PLANS 0 10/12/20 FINAL PLANS ISSUED A - GENERAL C - RF (COAX) AND LOW VOLTAGE CABLE Al. ALL ELECTRICAL WORK SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE (EDITION ADOPTED BY LOCAL Cl. RF CABLES AND LOW VOLTAGE CABLING BETWEEN BTS, LNA OR TMA AND ANTENNA SHALL BE SUPPORTED USING JURISDICTION) AND APPLICABLE LOCAL CODES. ANDREW "SNAP-IN" HANGERS OR ACCEPTABLE EQUAL. A2. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE. C2. RF CABLES AND LOW VOLTAGE CABLING BETWEEN BTS, LNA OR TMA AND ANTENNA SHALL BE ROUTED AS PROJECT NO.: 17-5053.1 FOLLOWS: DRAWN BY: M. THOMAS A3. ALL ELECTRICAL EQUIPMENT AND ACCESSORIES SHALL BE U.L. APPROVED OR LISTED. A) RUNNING ALONG HORIZONTAL SURFACES: USE WAVEGUIDE SUPPORTS OR BRIDGE KIT MOUNTED ON PROJECT MANAGER: D. REVELS CONCRETE SLEEPERS. A4. ALL POWER WIRING SHALL BE STRANDED COPPER, TYPE THHN/THHW, AND 90 DEGREES C RATED. B) RUNNING ALONG VERTICAL TOWER FACE: WAVEGUIDE LADDER W/HANGERS OR KELLEMS GRIPS. CHECKED BY: D. REVELS A5. GROUNDING ELECTRODE CONDUCTORS SHALL BE BARE, TIN COATED COPPER AND EQUIPMENT GROUND CONDUCTORS C) RUNNING ALONG OR ADJACENT TO BTS PLATFORM: USE 12 X 3 OPEN OR COVERED ELECTRICAL LADDER THIS DRAWING IS COPYRIGHTED AND IS SHALL BE GREEN INSULATED, UNLESS OTHERWISE NOTED. TRAY. THE SOLE PROPERTY of THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER ITS A6. ALL POWER WIRING SHALL BE INSTALLED IN GALVANIZED RIGID STEEL CONDUIT, PVC, OR FLEXIBLE LIQUIDTIGHT D — IDENTIFICATION REPRODUCTION ORDUSE OFFITIHIS DRAWING CONDUIT, AS INDICATED. AND/OR THE INFORMATION CONTAINED IN D1. LOCATE NAMEPLATE, MARKING, OR OTHER IDENTIFICATION MEANS ON OUTSIDE EQUIPMENT OR BOX FRONT COVERS. IT IS FORBIDDEN WITHOUT THE WRITTEN A7. CONTRACTOR SHALL OBTAIN ALL PERMITS, PAY PERMIT FEES, AND SCHEDULE INSPECTIONS. L PERMISSION of THE OWNER. D2. PROVIDE NAMEPLATE ENGRAVED WITH EQUIPMENT DESIGNATION FOR EACH SAFETY SWITCH AND ALL OTHER A8. CONTRACTOR SHALL APPLY FOR ELECTRICAL SERVICE AS SOON AS POSSIBLE AND COORDINATE REQUIREMENTS, SERVICE ELECTRICAL CABINETS, ETC. ROUTING, AND METER SOCKET TYPE WITH LOCAL POWER COMPANY. D3. DURING TRENCH BACK-FILLING FOR EACH UNDERGROUND ELECTRICAL, TELEPHONE, SIGNAL AND COMMUNICATIONS A9. CONTRACTOR SHALL APPLY FOR TELEPHONE SERVICE AS SOON AS POSSIBLE AND COORDINATE REQUIREMENTS AND LINE, PROVIDE A CONTINUOUS UNDERGROUND WARNING TAPE TWELVE INCHES BELOW FINISHED GRADE. SERVICE ROUTING WITH TELEPHONE COMPANY. "Imq �NOIN€�RI IQ GROUP, INC: A10. PROVIDE ALL LABOR AND MATERIAL DESCRIBED ON THIS DRAWING, AND ALL ITEMS INCIDENTAL TO COMPLETING AND PRESENTING THIS PROJECT AS FULLY OPERATIONAL. A11. WHERE LONG POWER CABLE RUNS PREVAIL, CONTRACTOR SHALL CALCULATE THE VOLTAGE DROP AND SIZE WIRES AND 13051 TELECOM PARKWAY, SUITE 100 CONDUIT ACCORDINGLY. TEMPLE TERRACE, FLORIDA 33637 (813) 615-1422 Al2. WHERE TRANSFORMER IS REQUIRED FOR ELECTRICAL SERVICE, TRANSFORMER SECONDARY SHALL BE GROUNDED PER CERTIFICATE OF AUTHORIZATION 28767 N.E.C., ARTICLE 250-26. A13. REFER TO SITE SPECIFIC DWGS FOR ELEVATIONS. A14. ALL ELECTRICAL DEVICES EXPOSED TO WEATHER SHALL BE OF RAINPROOF CONSTRUCTION AND SHALL REQUIRE WATER TIGHT CONDUIT HUBS. NEMA 3R TYPICAL m 1 - -Mobile A15. CONTRACTOR SHALL COIL CABLES AT HANDHOLE WITH LENGTHS AS REQUIRED BY ELECTRICAL UTILITY FOR CONNECTIONBY UTILITY. stick together' A16. ALL UNDERGROUND SERVICE ENTRANCE POWER CABLES SHALL BE TYPE FOR SUCH USE. CONTRACTOR SHALL 1300 CONCORD TERRACE SUITE zoo SUNRISE, FL 33323 CALCULATE VOLTAGE DROP AND RE-SIZE CABLES PER NEC REQUIREMENTS FOR CABLE RUNS EXCEEDING 250 FEET. B - POWER CABLE AND SERVICE B1. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRING TO BTS AND VERIFY EXACT CONDUIT ROUTING. RACEWAY SYSTEM MATERIALS AND DEVICES FURNISHED SHALL BE IN ACCORDANCE WITH APPLICABLE STANDARDS OF ANSI, NEMA, AND UL. RACEWAY SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE REQUIREMENTS OF THE N.E.C. B2. CONTRACTOR SHALL SEAL AROUND ALL CONDUIT PENETRATIONS THROUGH WALLS, FLOORS AND ROOFS TO PREVENT ���� ••••....•»•....•��• �i� MOISTURE PENETRATION OR VERMIN INFESTATION. B3. CONDUCTORS RUNNING ALONG HORIZONTAL SURFACES (ROOF TOP OR SLAB) SHALL BE INSTALLED IN RIGID CONDUIT SUPPORTED ON ELECTRICAL CONDUIT SUPPORT. NO. 751 B4. ALL VERTICAL RUNS OF POWER CABLE EXCEEDING 80 FEET IN LENGTH SHALL BE SUPPORTED PER N.E.C. ARTICLE 300 i e USING KELLEMS GRIPS OR ACCEPTABLE EQUAL CABLE SUPPORT SYSTEM. s B5. WHERE A SEPARATE ELECTRICAL SERVICE DROP IS ADDED, CONTRACTOR SHALL INSTALL PERMANENT SERVICE 00O•'•a. STATE DISCONNECT OR GROUPING THEREOF, DENOTING ALL OTHER SERVICE ENTRANCES, LOCATION OF EACH AND THE AREAS a,�P, P;•� �� SERVED BY EACH. /��`' '•a �OR� .••'`a_��`��� B6. WHERE ELECTRICAL POWER IS TO BE SUB-FED FROM AN EXISTING DISTRIBUTION SYSTEM, THE FOLLOWING SHALL APPLY: ///11111111111'�012�2 A) CONTRACTOR SHALL PERFORM LOAD TESTING TO DETERMINE MAXIMUM FEEDER DEMAND PER N.E.C. ARTICLE JEREMY D. SHARIT PE FL LIC 75137 220-35. B) CONTRACTOR SHALL VERIFY WHETHER EXISTING FEEDER CAPACITY EXCEEDS VALUE CALCULATED PER N.E.C. ARTICLE 220-35 C) EACH BRANCH CIRCUIT PROTECTIVE DEVICE SHALL HAVE SAME INTERRUPTING RATING AS EQUIPMENT SUPPLYING IT. ATC WOODCREST D) PREFERRED MEANS OF SUPPLY SHALL BE A BRANCH CIRCUIT PROTECTIVE DEVICE LOCATED IN EXISTING PANEL. E) IF A BRANCH CIRCUIT PROTECTIVE DEVICE CANNOT BE OBTAINED OR SPACE IS NOT AVAILABLE, A BRANCH CIRCUIT MAY BE TAPPED FROM EXISTING FEEDER CONDUCTORS USING AN INSTALLED 2-POLE FUSED DISCONNECT A2P0048—A AND METER BASE PER N.E.C. ARTICLE 240-21 WITH TEN FOOT (10) MAXIMUM TAP CONDUCTORS. FUSED DISCONNECT SHALL BE LISTED SAME OR BETTER INTERRUPTING RATING AS EXISTING SOURCE OF SUPPLY. 14101 SOUTH ANGLE ROAD WEST ST. LUCIE, FLORIDA 34945 (ST. LUCIE COUNTY) SHEET NAME ELECTRICAL NOTES SHEET NUMBER ELECTRICAL NOTES 1 E1 REV DATE DESCRIPTION A - GENERAL D - LAND BUILDS AND CO-LOCATES A 10/05/20 PRELIM PLANS 0 10/12/20 FINAL PLANS ISSUED Al. INSTALLATION OF GROUNDING ELECTRODE SYSTEM SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE AND WITH D1. THE GROUND ELECTRODE SYSTEM SHALL CONSIST OF DRIVEN GROUND RODS UNIFORMLY SPACED AROUND THE EQUIPMENT ALL BUILDING CODES OF AUTHORITIES HAVING JURISDICTION. FOUNDATION AND AROUND THE PERIMETER OF THE TOWER FOUNDATION. THE GROUND RODS SHALL BE %" X 10'-0" COPPER CLAD STEEL INTERCONNECTED WITH #2 SOLID TINNED BARE COPPER GROUND CONDUCTOR TO FORM A GROUND RING AT A DEPTH OF 30 A2. GROUNDING CONDUCTORS SHALL BE #2 AWG TINNED SOLID BARE COPPER BELOW AND ABOVE GRADE, UNLESS OTHERWISE NOTED INCHES BELOW THE SURFACE OF THE SOIL. A MINIMUM OF 1 FOOT AND A MAXIMUM OF 3 FEET CLEARANCES SHALL BE MAINTAINED AND SHALL BE ROUTED IN A DOWNWARD PATH TOWARDS GROUND BARS. FROM FOUNDATIONS. TOWER AND EQUIPMENT GROUND RINGS SHALL BE INTERCONNECTED WITH TWO GROUNDING CONDUCTORS OF EQUAL LENGTH AND MATERIALS. A3. GROUNDING CONDUCTORS SHALL BE KEPT AS SHORT AND DIRECT AS POSSIBLE WITH MINIMUM BEND RADIUS OF 12 INCHES. D2. GROUND RODS SHALL BE BONDED TO GROUND RINGS AND INTERCONNECTING CONDUCTORS AT EQUAL INTERVALS OF APPROXIMATELY A4. ALL BELOW GRADE CONNECTIONS SHALL BE CADWELD TYPE CONNECTIONS AND ALL CONNECTIONS TO EQUIPMENT AND GROUND BARS 10 FEET. SHALL BE 2-HOLE BRONZE COMPRESSION CONNECTORS UNLESS OTHERWISE NOTED. PROJECT NO.: 17-5053.1 D3. WAVEGUIDE BRIDGE SHALL BE BONDED TO GROUND RINGS OR INTERCONNECTING CONDUCTORS WITH GROUNDING CONDUCTORS DRAWN BY: M. THOMAS A5. CONTRACTOR SHALL INSTALL NEW PCS GROUNDING SYSTEM PER SPECIFICATIONS AND INTERCONNECT NEW SYSTEMS TO ANY EXISTING BONDED TO DIAGONALLY OPPOSED SUPPORT POSTS. GROUNDING SYSTEMS AS REQUIRED BY NFPA 70 AND 780 (THIS APPLIES TO ELECTRICAL POWER DISTRIBUTION GROUNDING SYSTEM, PROJECT MANAGER: D. REVELS LIGHTNING PROTECTION GROUNDING SYSTEM, COAX CABLE GROUNDING SYSTEM AND ANY OTHER EXISTING GROUNDING SYSTEMS). D4. GROUND BARS SHALL BE BONDED TO GROUND RING WITH SINGLE GROUNDING CONDUCTOR. CHECKED BY: D. REVELS A6. GROUNDING CONDUCTORS SHALL BE BONDED TO CABLE SUPPORTS, ANTENNA FRAMES, AND ANY SUPPORT FRAMES OR RACKS USING D5. BONDS TO ANTENNA MASTS, FENCE POSTS, WAVEGUIDE BRIDGE, TOWER STEEL (UNLESS PROHIBITED BY TOWER MANUFACTURER) AND THIS DRAWING IS COPYRIGHTED AND IS CADWELD OR MECHANICAL CONNECTIONS. THOSE BELOW GRADE SHALL BE EXOTHERMIC TYPE (CADWELD). ALL OTHER BONDS SHALL BE BRONZE 2-HOLE COMPRESSION THE SOLE PROPERTY OF THE OWNER. IT FITTINGS UNLESS OTHERWISE NOTED. IS PRODUCED SOLELY FOR USE BY THE A7. CONTRACTOR SHALL PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND CONDUCTORS, STAINLESS STEEL OWNER AND ITS AFFILIATES. HARDWARE SHALL BE USED THROUGHOUT. REPRODUCTION OR USE OF THIS DRAWING D6. GROUNDING CONDUCTORS MAKING A TRANSITION FROM ABOVE TO BELOW GRADE SHALL BE INSULATED FROM EARTH CONTACT BY AND/OR THE INFORMATION CONTAINED IN PASSING THROUGH PVC CONDUIT. THE CONDUIT SHALL EXTEND AT LEAST 6 INCHES ABOVE AND 12 INCHES BELOW GRADE LEVEL. IT IS FORBIDDEN WITHOUT THE WRITTEN A8. GROUNDING CONDUCTORS EMBEDDED IN CONCRETE OR PENETRATING WALLS AND FLOORS SHALL BE ENCASED IN PVC CONDUIT. NO PERMISSION OF THE OWNER. METALLIC CONDUIT SHALL BE USED FOR GROUNDING CONDUCTORS UNLESS REQUIRED BY LOCAL CODES OR OTHERWISE INDICATED E - LIGHTNING PROTECTION ON DRAWINGS. CONTRACTOR SHALL SEAL AROUND ALL CONDUIT PENETRATIONS TO PREVENT MOISTURE PENETRATION AND VERMIN INFESTATION. E1. IF EXISTING BUILDING HAS AN NFPA 780 AIR TERMINAL SYSTEM, EXISTING SYSTEM SHALL BE BONDED TO A GROUND BAR TO BOND THE EXISTING SYSTEM TO THE NEW SYSTEM. SHOULD THE EXISTING SYSTEM COME WITHIN 8 FEET OF ANTENNA STRUCTURES, A9. CONTRACTOR SHALL BOND PCS GROUNDING SYSTEM VIA THE MASTER GROUND BAR TO ALL METAL OBJECTS WITHIN 12 FEET OF EXISTING SYSTEM SHALL ALSO BE BONDED TO COAX GROUND BARS. EQUIPMENT, CONDUIT AND CABLES. T I E2. IF SITE IS IN A HIGH RISK AREA AND ANTENNAS DO NOT FALL WITHIN EXISTING CONE OF PROTECTION FOR BUILDING, AIR TERMINALS €N Q I N€€R I N C GROUP, 1 N C: A10. BONDING OF GROUNDED CONDUCTOR (NEUTRAL) AND GROUNDING CONDUCTOR SHALL BE AT SERVICE DISCONNECTING MEANS. SHALL BE INSTALLED AT ANTENNAS. A SINGLE AIR TERMINAL MAY BE USED WHEN TWO ANTENNAS ARE MOUNTED ON SAME BONDING JUMPER SHALL BE INSTALLED PER N.E.C. ARTICLE 250-28. STRUCTURE AND IT HAS BEEN DETERMINED THAT BOTH ANTENNAS WILL FALL WITHIN LIGHTNING CONE OF PROTECTION FOR SINGLE AIR TERMINAL. Al 1. CONTRACTOR SHALL VERIFY EXACT CONDUIT ROUTING FOR GROUNDING CONDUCTORS WHERE APPLICABLE. 13051 TELECOM PARKWAY, SUITE 100 T - GROUNDING REQUIREMENTS TEMPLE TERRACE, FLORIDA 33637 Al2. A GROUND LEAD IS REQUIRED ONLY FOR BTS SUPPORTED ON STEEL FRAME. AN ADDITIONAL GROUND LEAD IS REQUIRED IF CABLE (813) 615-1422 TRAY IS USED. T1. CONTRACTOR SHALL INSPECT AND TEST ANY NEW OR EXISTING T-MOBILE GROUNDING SYSTEM WITH A BIDDLE-MEGGER TESTER CERTIFICATE OF AUTHORIZATION 28767 UTILIZING THE FALL OF POTENTIAL METHOD AND CONTACT CONSTRUCTION MANAGER IF RESISTANCE EXCEEDS 5 OHMS AND SHALL A13. CONNECTIONS TO CGB SHALL BE ARRANGED IN THE FOLLOWING THREE GROUPS: FIELD MODIFY GROUNDING SYSTEM AS NECESSARY TO ACHIEVE COMPLIANCE. TEST RESULTS AND CONCLUSIONS SHALL BE RECORDED FOR PROJECT CLOSE-OUT DOCUMENTATION. • SURGE PRODUCERS (COAXIAL CABLE GROUND KITS, TELCO CABINET AND POWER PEDESTAL GROUND). • SURGE ABSORBERS (GROUNDING ELECTRODE RING OR BUILDING STEEL). T2. COAX CABLE OUTER CONDUCTORS (SHIELDS) SHALL BE GROUNDED USING COAX GROUNDING KITS AT A MINIMUM OF TWO POINTS, • NON-SURGING OBJECTS (EGB GROUND IN BTS). INCLUDING AT ANTENNA AND AT MASTER GROUND BAR. THE COAXIAL CABLE SHALL NOT EXCEED 100 FEET BETWEEN GROUNDING ;J; ■ .Mobile A14. DOUBLING OR STACKING OF ANY GROUNDING CONNECTIONS IS NOT ACCEPTABLE. KITS. 11 T3. GROUNDING CONDUCTOR CONSISTING OF 2-#2 AWG TINNED SOLID BARE COPPER WIRE SHALL BE BONDED TO WAVEGUIDE ENTRY stick together' A15. ALL GROUND BARS SHALL BE INSTALLED WITH STAND OFF INSULATORS. GROUND BAR USING CADWELD CONNECTIONS. 300 CONCORD TERRACE SUITE zoo SUNRISE, FL 33323 B - PREPARATION T4. COAX CABLE ENTERING A BUILDING SHALL BE GROUNDED WITH COAX GROUNDING KITS TO AN INSULATED COAX GROUND BAR WHICH SHALL BE INSTALLED ON THE OUTSIDE FACE OF THE BUILDING, BELOW THE CABLE ENTRY PORTS. B1. SURFACES: ALL CONNECTIONS SHALL BE MADE TO BARE METAL. ALL PAINTED SURFACES SHALL BE FIELD INSPECTED TO ENSURE PROPER CONTACT. ALL GALVANIZED SURFACES ON WHICH GALVANIZING HAS BEEN REMOVED BY CUTTING, DRILLING, OR ANY OTHER T5. WHEN COAX CABLES ENTER A BUILDING FROM A TOWER, THE COAX GROUND BAR AT THE BUILDING SHALL BE CONNECTED TO THE OPERATION SHALL BE RE-GALVANIZED IN ACCORDANCE WITH ASTM A780 USING "ZINC RICH" COATING AS MANUFACTURED BY ZRC EXTERNAL GROUND RING USING 2-#2 AWG BARE TINNED SOLID COPPER ISOLATED IN PVC CONDUIT. CHEMICAL PRODUCTS COMPANY (LOCATED IN QUINCY, MASSACHUSETTS), OR ACCEPTABLE EQUAL. NO WASHERS ARE ALLOWED BETWEEN ITEMS BEING GROUNDED. ALL CONNECTIONS ARE TO HAVE A NON-OXIDIZING AGENT ("COPPER SHIELD") APPLIED PRIOR TO T6. WHEN COAX CABLES ENTER A BUILDING FROM A ROOF TOP, THE COAX GROUND BAR AT THE BUILDING SHALL BE CONNECTED TO INSTALLATION. THE MASTER GROUND BAR NEAR THE BTS USING #2 AWG STRANDED INSULATED COPPER CONDUCTOR (SEE BUILDINGS NOTES ON \\ M� D• S /// THIS DRAWING FOR CONNECTION TO PRINCIPLE GROUND BAR AND BUILDING GROUND). \��4 �.•••"••"""•••.• /// B2. GROUND BAR: ALL COPPER GROUND BARS SHALL BE CLEANED, POLISHED AND A NON-OXIDIZING AGENT ("COPPER SHIELD") `� �`,,'��GENS,(••• • �� APPLIED. NO FINGER PRINTS OR DISCOLORED COPPER SHALL BE PERMITTED. `' ••••.•� C - BUILDINGS = No. 751 s Cl. ELECTRICAL CONTRACTOR SHALL PERFORM REQUIRED TESTING ON GROUNDING SYSTEM ONCE GROUNDING SYSTEM IS COMPLETELYCC ' CONSTRUCTED AND BEFORE SERVICE POWER AND GROUND IS CONNECTED (SEE NOTE T1 FOR TEST DESCRIPTION). s STATE OF •'�� C2. A #4/0 AWG COPPER CONDUCTOR SHALL BE ROUTED FROM MASTER GROUND BAR AT BTS SITE TO MAIN METAL COLD WATER PIPE AND BONDED TO PIPE WITH BRONZE 2-HOLE PIPE CLAMP. CLAMP SHALL BE CONNECTED TO WATER PIPE WITHIN 5 FEET OF ENTRY �i '•.F�QR�Op.�• '� OF PIPE INTO BUILDING WITH NO DEVICES BETWEEN ENTRY POINT AND CONNECTION AND SHALL COME IN CONTACT WITH PIPE FORA ��/�AS~•"•••••••'•'••' `a� \�� MINIMUM DISTANCE OF 4 INCHES. '�ONAL, ^lj / C3. METAL RACEWAYS, ENCLOSURES, FRAMES AND OTHER NON-CURRENT CARRYING PARTS OF ELECTRICAL EQUIPMENT SHALL BE KEPT ll1111 10 12 2 AT LEAST 6 FEET AWAY FROM LIGHTNING ROD CONDUCTORS OR THEY MUST BE BONDED TO LIGHTING ROD CONDUCTORS AT THE JEREMY D. SHARIT PE FL LIC 75137 LOCATION WHERE SEPARATION DISTANCE IS LESS THAN 6 FEET. C4. A MASTER GROUND BAR (MGB) SHALL BE INSTALLED NEAR BTS WITH BUILDING PRINCIPAL GROUND BAR (BPG) INSTALLED NEAR ENTRANCE OF MAIN METAL COLD WATER PIPE INTO BUILDING. A #4/0 AWG STRANDED COPPER DOWN CONDUCTOR (VERTICAL ATC WOODCREST GROUND RISER) SHALL BE USED TO INTERCONNECT GROUND BARS. C5. VERTICAL RISER SHALL CONSIST OF A #4/0 AWG (THWN) STRANDED COPPER CONDUCTOR INSIDE 3/4" CONDUIT. A2P0048-A 01 C6. CONTRACTOR SHALL BOND BUILDING PRINCIPAL GROUND BAR BPG NEAR MAIN METAL COLD WATER PIPE TO EXISTING BUILDING SOUTH ANGLE ROAD ( ) WEST ST. LUCIE, FLORIDA 34945 GROUND RING AS WELL AS TO MAIN METAL COLD WATER PIPE WITH #4/0 AWG (THWN) STRANDED COPPER CONDUCTOR. (ST. LUCIE COUNTY) C7. ANTENNA GROUND BARS (AGB) SHALL BE INSTALLED NEAR ANTENNAS AND SHALL BE BONDED TO MASTER GROUND BAR (MGB) WITH SHEET NAME #2 AWG TINNED SOLID BARE COPPER CONDUCTOR. GROUNDING C8. IF CODES REQUIRE VERTICAL RISER TO BE ISOLATED IN CONDUIT, PVC CONDUIT IS PREFERRED. IF METALLIC CONDUIT IS USED, NOTES GROUNDING BUSHINGS SHALL BE INSTALLED ON EACH END OF THE CONDUIT AND BONDED TO GROUND BARS USING #2 AWG (THWN) STRANDED COPPER CONDUCTORS WITH GREEN INSULATION. SHEET NUMBER [GROUNDING NOTES 1 1 E2 2' 0' 1' 2' REV DATE DESCRIPTION A 10/05/20 PRELIM PLANS FOR 24"06" DRAWINGS 0 10/12/20 FINAL PLANS ISSUED GRAPHIC SCALE: 1" = 1'-0" FOR 11"x17" DRAWINGS GRAPHIC SCALE: 1/2" = 1'-0" PROJECT NO.: 17-5053.1 WAVEGUIDE BRIDGE DRAWN BY: M. THOMAS (TYP.) PROJECT MANAGER: D. REVELS CHECKED BY: D. REVELS THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING �9�1 ��, 9 1�_ AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PROPOSED T—MOBILE PERMISSION OF THE OWNER. EMERGENCY GENERATOR COVP SHUT—OFF SWITCH C5 EXISTING T—MOBILE TELCO RRU (TYP.) FiNOIN€9RINO GROUP, INC: ENCLOSURE Q L I TAe T 1€� Ear r11et®� @i @xm� ®W I Fr- SSC 13051 TELECOM PARKWAY, SUITE 100 r1, F ¢ TEMPLE TERRACE, FLORIDA 33637 i / I � PROPOSED T—MOBILE (513) 615-1422 i I 25KW DIESEL GENERATOR PROPOSED T—MOBILE 200A., PROPOSED 2"0 CONDUIT FOR POWER i j I cERnFICAT of AU oRlznnoN 2e7s7 120/24OV, 10 UTILITY FROM EXISTING SERVICE TO PROPOSED ON PROPOSED 4'x9' METER T—MOBILE 200A. UTILITY METER CONCRETE PAD I P I I � PROPOSED 2"0 CONDUIT FOR POWER I T - -Mobile FROM PROPOSED SERVICE DISCONNECT I TO PROPOSED T—MOBILE 200A. PPC FCOA I stick together® PROPOSED T—MOBILE � I 120/240V, 10 SERVICERVICE ENCLOSURE ¢/ � 130o CONCORD TERRACE SUITE zoo DISCONNECT f Q I O SUNRISE, FL 33323 Q COVP / I ---------, I A I I P a CIL 5 C5 j ¢ ------------------------------------------------------- -- ----- A A A A A A A A A `��� ».....•••rye //// GENScc ;.>► PROPOSED T—MOBILE 200A., ? NO. 751 120/240V, 1 PPC PROPOSED 3/4„ CONDUIT FOR (2) CAT5 ALARM CABLES FROM PROPOSED O O ENCLOSURE GENERATOR TO EXISTING FCOA CABINET ® e z � � ��: STATE OF •'�� PROPOSED -'4"0 CONDUIT FOR EMERGENCY i O SHUT—OFF SWITCH W/ (2) #18 ��/�,(�a•.•F�ORfjOP,� (1) PROPOSED 3/4"0 CONDUIT FOR �iONAL BATTERY CHARGER & (1) PROPOSED 3/4"0 CONDUIT FOR GENERATOR BLOCK JEREMY D. SHARIT PE FL LIC 75137 HEATER FROM PROPOSED GENERATOR TO PROPOSED T—MOBILE PPC ENCLOSURE PROPOSED %"0 CONDUIT FOR ALARM ATC WOODCREST WIRING FROM PROPOSED GENERATOR TO PROPOSED T—MOBILE PPC ENCLOSURE PROPOSED 2"0 CONDUIT FOR POWER A2P0048—A FROM EXISTING SERVICE DISCONNECT 14101 SOUTH ANGLE ROAD TO PROPOSED T—MOBILE PPC ENCLOSURE WEST ST. LUCIE, FLORIDA 34945 (ST. LUCIE COUNTY) SHEET NAME CONDUIT ROUTING PLAN N SHEET NUMBER ENLARGED CONDUIT ROUTING PLAN NTS E3 REV DATE DESCRIPTION A 10/05/20 PRELIM PLANS 0 10/12/20 FINAL PLANS ISSUED 2P-40A 2P-60A BTS SURGE 2P-40A 2P-50A SPARE SSC PROPOSED T-MOBILE 200A., 120/240V, 10 UTILITY METER P-20A 1P-15A PROJECT NO.: 17-5053.1 ON EXISTING T-MOBILE H-FRAME SPARE BECEP DRAWN BY: M. THOMAS PROJECT MANAGER: D. REVELS P-10A 1P-20A1 17- CHECKED BY: D. REVELS FROM UTILITY M SPARE __—F �7R CHARGER THIS DRAWING IS COPYRIGHTED AND IS THE SOLE IT (3) #3/0 & (14 GRID1P-20A IS PRODUCEDOPERTY SOLELYOFORHUSEW )# BY THE IN 2"0 CONDUIT BLOCK OWNER AND ITS AFFILIATES. HEATER REPRODUCTION OR USE OF THIS DRAWING THEIN (3) 3/0 & (1) #4 GIRD AITDISOFORBDDENOWITHO T THHEATIONTAINED WRITfEN IN 2"0 CONDUIT PERMISSION OF THE OWNER. Qo PROPOSED T-MOBILE (3) #3/0 & (1)#4 GRID 0 200A., 120/240V, 10 IN 2"0 CONDUIT a PPC ENCLOSURE N PROPOSED 200A. SERVICE RATED BREAKER CNGINI€RING GFI INC: TC fgv,TiiRR PIANNSN®A RRTTRR TOM%RR®tl6 13051 TELECOM PARKWAY, SUITE 100 TEMPLE TERRACE, FLORIDA 33637 (3) 3/0 & (1) #4 GRID IN (813) 615-1422 2"0 CONDUIT CERTIFICATE OF AUTHORIZATION 28767 PROPOSED 25KW DIESEL GENERATOR T • •Mobile: stick topther' 1300 CONCORD TERRACE SUITE 2DO SUNRISE, FL 33323 ELECTRICAL ONE-LINE DIAGRAM NTS 1 PANEL NAME: T-MOBILE PANEL RATING 200 AMPS PHASE 1 200 MCB RATING 200 AMP LOCATION: H-FRAME 120/240 VOLTS WIRE 3 MAIN LUG ONLY 65L AIC �` �����` °•,� CKT DESCRIPTION KVAB AMP WIRE GND COND COND GND WIRE AMP KVA B CKT DESCRIPTION s NO. 751 3 BTS 2-5 2.5 200/2 (E) (E) (E) (E) (E) (E) 60/2 _ _ SURGE 4 Zs STATE OF •'•� 5 SPARE 40/2 (E) (E) (E) (E) (E) (E) 50/2 4.8 - SSC 6 � °••N.....�OR��P`������ 9 SPARE - - 20/1 (E) (E) (E) (E) (E) (E) 15/1 0.18 - RECEP 10 //////s/6NA�- 11 SPARE - - 10/1 (E /(E E 3/4" #10 #10 20/1 - 0.74 BATTERY CHARGER 12 �SHARITil PE FIL� 37 l ) l ) ( ) JEREMY D. SHARIT PE FL LIC 75137 13 SPACE - - - - - - 3/4" #10 #10 20/1 0.74 - BLOCK HEATER 14 15 SPACE - - - - - - - - - - - - SPACE 16 17 SPACE - - - - - - - - - - - - SPACE 18 ATC WOODCREST 19 SPACE - - - - - - - - - - - - SPACE 20 21 SPACE - - - - - - - - - - - - SPACE 22 A2P0048—A 23 SPACE - - - - - - - - - Ett5.05 SPACE 24 14101 SOUTH ANGLE ROAD SUB TOTAL KVA(CONT) 0 0 SUB TOTAL KVA(CONT) wEsr (ST.T. LLUCIE COUNTY)FLORIDA 34945 SUB TOTAL KVA(N ON-C ON T) 2.5 2.5 SUB TOTAL KVA(NON-CONT) SHEET NAME TOTAL KVA 16.3 67.8 TOTAL AMPS NON-CONT+ 125% CONT. ONE—LINE AND PANEL SCHEDULE SHEET NUMBER (PROPOSED PANEL SCHEDULE NTS 2 E4 4' 0' 2' 4' REV DATE DESCRIPTION A 10/05/20 PRELIM PLANS FOR 24"06" DRAWINGS GROUNDING KEY NOTES: 0 10/12/20 FINAL PLANS ISSUED GRAPHIC SCALE: 1/2" = 1'-0" FOR 11"x17" DRAWINGS O1 EXISTING T-MOBILE EQUIPMENT GROUND RING. CONTRACTOR TO VERIFY GRAPHIC SCALE: 1/4" = 1'-0" SERVICEABILITY AND REPAIR/REPLACE AS NEEDED. Q2 #2 AWG BOND TO EXISTING T-MOBILE GROUND RING. K EY PROJECT NO.: 17-5053.1 ♦ BOND DRAWN BY: M. THOMAS INSPECTION WELL PROJECT MANAGER: D. REVELS CHECKED BY: D. REVELS THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. 10 xx xx1 10 GROUP, INC: RQF3�.'T#1@R>A>EAN1i1it®A»@l`1f'@R i'@MARR®tl6 ---------------------------- -- ------- -- --------------%-------------------- l \ 13051 TELECOM PARKWAY, SUITE 100 0/ 4/ - I TEMPLE TERRACE, FLORIDA 33637 / \ (813) 615-1422 CERTIFICATE OF AUTHORIZATION 28767 (TYP.) \]:D T - -Mobile stick together' 1300 CONCORD TERRACE SUITE 200 SUNRISE, FL 33323 (TYP.) I I J I I � I p / 4 ® I �, ;�J► 2 1 `7 a No. 751 (TYP.)) i � 4 - 00 STATE OF ---- ------ ----- ------------------------------------------------------------------- //,,,�NA��1�01 12/2 JEREMY D. SHARIT PE FL LIC 75137 ATC WOODCREST A2P0048—A 14101 SOUTH ANGLE ROAD WEST ST. LUCIE, FLORIDA 34945 (ST. LUCIE COUNTY) SHEET NAME GROUNDING PLAN N ; SHEET NUMBER GROUNDING DIAGRAM (TYP.) SCALE AS NOTED E5 REV DATE DESCRIPTION A 10/05/20 PRELIM PLANS 0 10/12/20 FINAL PLANS ISSUED FINISH GRADE \\ \\ a PLASTIC TEST WELL \\ \\\\ \\\\ oG¢°0 COVER EXTERIOR GROUND PROJECT NO.: 17-5053.1 DRAWN BY: M. THOMAS \\ \ \\\ \\\\ RING, #2 SOLID, 6" PVC TEST LOOP BARE, THINNED NO SLAG OR \r PROJECT MANAGER: D. REVELS z COPPER GROUNDING DEFORMITIES ALLOWED CHECKED BY: D. REVELS CONDUCTOR EXOTHERMIC EXOTHERMIC WELD THIS DRAWING IS COPYRIGHTED AND IS CONNECTION (TYP.) GROUND CABLE (THERMOWELD THE SOLE PROPERTY OF THE OWNER. IT N IS PRODUCED SOLELY FOR USE BY THE 1"x4" SLOT IN PVC OR EQUIVALENT) OWNER AND ITS AFFILIATES. PARALLEL, NO REPRODUCTION OR USE OF THIS DRAWING PIPE AT GROUND T—WELDS ALLOWED. AND/OR THE INFORMATION CONTAINED IN CABLE LOCATION IT IS FORBIDDEN WITHOUT THE WRITTEN 11. PERMISSION OF THE OWNER. 10 3" COMPACTED MINIMUM BENDING RADIUS SAND FILL 45 DEGREES, TYPICAL JUMPER, #2 SOLID, BARE, TINNED N@ I N€ R I 10 GROUP, 1 N C: COPPERCLAD STEEL COPPER GROUNDING CONDUCTOR TAe T1€��Ea�rllet®�axT�xmt� ®W GROUND ROD x 10' (TYP.) 13051 TELECOM PARKWAY, SUITE 100 TEMPLE TERRACE, FLORIDA 33637 (813) 615-1422 CERTIFICATE OF AUTHORIZATION 28767 76, 6 T - -Mobile NOTE: stick together' ALL WORK SHALL CONFORM TO THE LOCAL 73 OCONCORD TERRACE SUITE 200 BUILDING CODES. DEPTH MAY VARY. SUNRISE, FL 33323 GROUND ROD INSPECTION WELL DETAIL NTS 1 EXOTHERMIC WELD DETAIL NTS 2 FINISHED GRADE E COLD GA VANIZE t AFTER COOLING. z �•: STATE IDF •'�� cn FENCE POST i •'. \x �\ COMPACTED BACKFILL �� `' •••• OR`� •• �'`\ o wVA.I�\ \�AA�AA TO 95% OF PROCTOR D_w /\ \ \ \ DENSITY / \\ o \j\j\ 12/2 0 m /�\ \' / / JEREMY D. SHARIT PE FL LIC 75137 WARNING TAPE �\ CY --- Off M — ATC WOODCREST\\ \ '<7CONCRETE 18" TRENCH OR WIRAWG BARE, TINNED,E TO B S GROUND / FOOTING AS REQUIRED BY WIRE A2P0048—A POWER/TELEPHONE RING. \\ \\\\\ 14101 SOUTH ANGLE ROAD COMPANY / \ \\+,'' \\ \\ WEST ST. LUCIE, FLORIDA 34945 . (ST. LUCIE COUNTY) \�j\\,••: .:- /\\/� SHEET NAME VA\VA\VA\ GROUNDING D ETAI LS SHEET NUMBER UTILITY TRENCH DETAIL NTS 3 FENCE POST BONDING DETAIL NTS 4 E6