SD25 Spec Sheet 0K5084
UL2200, UL508, UL142, UL498 NFPA70, 99, 110, 37 NEC700, 701, 702, 708 ISO9001, 8528, 3046, 7637, Pluses #2b, 4 NEMA ICS10, MG1, 250, ICS6, AB1 ANSI C62.41 Image used for illustration purposes only*EPA Certified Prime ratings are not available in the U.S. or its Territories. *Built in the USA using domestic and foreign parts **Certain options or customization may not hold certification valid. SP E C S H E E T 1 OF 6 STANDBY POWER RATING PRIME POWER RATING* CODES AND STANDARDS Generac products are designed to the following standards: POWERING AHEAD For over 50 years, Generac has led the industry with innovative design and superior manufacturing. Generac ensures superior quality by designing and manufacturing most of its generator components, inclu ding alternators, enclosures and base tanks, control syste ms and communications software. Generac’s gensets utilize a wide variety of options, con figurations and arrangements, allowing us to meet the standby power needs of practically every application . Generac searched globally to ensure the most reliabl e engines power our generators. We choose only engines t hat have already been proven in heavy-duty industrial a pplication under adverse conditions. Generac is committed to ensuring our customers’ servi ce support continues after their generator purchase. SD025 | 2.4L | 25 kW INDUSTRIAL DIESEL GENERATOR SE T EPA Certified Stationary Emergency 25 kW, 31 kVA, 60 Hz 23 kW, 28 kVA, 60 Hz ENGINE SYSTEM General Oil Drain Extension Air Cleaner Fan Guard Stainless Steel flexible exhaust connection Critical Exhaust Silencer (enclosed only) Factory Filled Oil Radiator Duct Adapter (open set only) Fuel System Fuel lockoff solenoid Primary fuel filter Cooling System Closed Coolant Recovery System UV/Ozone resistant hoses Factory-Installed Radiator Radiator Drain Extension 50/50 Ethylene glycol antifreeze Engine Electrical System Battery charging alternator Battery cables Battery tray Solenoid activated starter motor Rubber-booted engine electrical connections ALTERNATOR SYSTEM UL2200 GENprotect 12 leads (3-phase, non 600 V) Class H insulation material Vented rotor 2/3 pitch Skewed stator Auxiliary voltage regulator power winding GENERATOR SET Internal Genset Vibration Isolation Separation of circuits - high/low voltage Separation of circuits - multiple breakers Silencer Heat Shield Wrapped Exhaust Piping ENCLOSURE (IF SELECTED) Rust-proof fasteners with nylon washers to protect finish High performance sound-absorbing material Gasketed doors Stamped air-intake louvers Air discharge hoods for radiator-upward pointing Stainless steel lift off door hinges Stainless steel lockable handles TANKS (IF SELECTED) UL 142 Double wall Vents Sloped top Sloped bottom Factory pressure tested (2 psi) Rupture basin alarm Fuel level Check valve in supply and return lines Rhino Coat - Textured polyester powder coat CONTROL SYSTEM Control Panel Digital H Control Panel - Dual 4x20 Display Programmable Crank Limiter 7-Day Programmable Exerciser Special Applications Programmable PLC RS-232/485 All-Phase Sensing DVR Full System Status Utility Monitoring Low Fuel Pressure Indication 2-Wire Start Compatible kW Hours, Total & Last Run Real/Reactive/Apparent Power All Phase AC Voltage All Phase Currents Oil Pressure Coolant Temperature Coolant Level Engine Speed Battery Voltage Frequency Date/Time Fault History (Event Log) Isochronous Governor Control Waterproof/sealed Connectors Audible Alarms and Shutdowns Not in Auto (Flashing Light) E-Stop (Red Mushroom-Type) NFPA110 Level I and II (Programmable) Customizable Alarms, Warnings, and Events Modbus protocol Predictive Maintenance algorithm Sealed Boards Password parameter adjustment protection Single point ground 15 channel data logging 0.2 msec high speed data logging Alarm information automatically comes up on the display Alarms Oil Pressure (Pre-programmable Low Pressure Shutdown) Coolant Temperature (Pre-programmed High Temp Shutdown) Coolant Level (Pre-programmed Low Level Shutdown) Low Fuel Pressure Alarm Engine Speed (Pre-programmed Over speed Shutdown) Battery Voltage Warning Alarms & warnings time and date stamped Alarms & warnings for transient and steady state conditions Snap shots of key operation parameters during alarms & warnings Alarms and warnings spelled out (no alarm codes) 120 VAC Coolant Heater TM Amortisseur winding Brushless Excitation Sealed Bearings Automated manufacturing (winding, insertion, lacing, varnishing) Rotor dynamically spin balanced Full load capacity alternator Protective thermal switch Silencer housed in discharge hood (enclosed only) Standard Factory Testing 2 Year Limited Warranty (Standby rated Units) 1 Year Limited Warranty (Prime rated Units) Silencer mounted in the discharge hood (enclosed only) Rhino Coat - Textured polyester powder coatTM TM Stainless hardware Power Output (kW) Power Factor Auto/Off/Manual Switch SP E C S H E E T 2 OF 6 SD025 | 2.4L | 25 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency STANDARD FEATURES RATING DEFINITIONS ENGINE SYSTEM General О Oil Heater О Industrial Exhaust Silencer Fuel System О Flexible fuel lines О Primary fuel filter ENCLOSURE О Weather Protected О Level 1 Sound Attenuation О Level 2 Sound Attenuation О Steel Enclosure О Aluminum Enclosure О 150 MPH Wind Kit О 12 VDC Enclosure Lighting Kit TANKS (Size on last page) О Electrical Fuel Level О Mechanical Fuel Level О 54 Gal (204.4 L) Usable Capacity О 132 Gal (499.7 L) Usable Capacity О 211 Gal (798.7 L) Usable Capacity О 300 Gal (1135.6 L) Usable Capacity CONTROL SYSTEM ALTERNATOR SYSTEM О Alternator Upsizing О Anti-Condensation Heater CIRCUIT BREAKER OPTIONS О Main Line Circuit Breaker О 2nd Main Line Circuit Breaker О Shunt Trip and Auxiliary Contact О Electronic Trip Breaker GENERATOR SET О Gen-Link Communications Software (English Only) О 8 Position Load Center О 2 Year Extended Warranty О 5 Year Warranty О 5 Year Extended Warranty О 120 VAC Enclosure Lighting Kit О 21-Light Remote Annunciator О Remote Relay Panel (8 or 16) О Oil Temperature Sender with Indication Alarm О Remote E-Stop (Break Glass-Type, Surface Mount) О Remote E-Stop (Red Mushroom-Type, Surface Mount) О Remote E-Stop (Red Mushroom-Type, Flush Mount) О Remote Communication - Modem О Remote Communication - Ethernet О 10A Run Relay О Ground Fault Indication and Protection FunctionsENGINEERED OPTIONS ENGINE SYSTEM О Coolant heater ball valves О Block Heaters О Fluid containment pans ALTERNATOR SYSTEM О 3rd Breaker Systems CONTROL SYSTEM О Spare inputs (x4) / outputs (x4) - H Panel Only О Battery Disconnect Switch TANKS О О UL2085 Tank О ULC S-601 Tank О Stainless Steel Tank О Special Fuel Tanks (MIDEQ and FL DEP/DERM, etc.) О Vent Extensions Standby - Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. Prime - Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. A 10% overload capacity is available for 1 out of every 12 hours. The Prime Power option is only available on International applications. Power ratings in accordance with ISO 8528-1, Second Edition Overfill Protection Valve Engine Electrical System О 10A UL battery charger О 2.5A UL battery charger О Battery Warmer О Tropical coating О Permanent Magnet Excitation О AC/DC Enclosure Lighting Kit О GENERATOR SET О Special Testing О IBC Seismic Certification ENCLOSURE О Motorized Dampers О Door switched for intrusion alert Door Alarm Switch О 8” Fill Extension О 13” Fill Extension О 19” Fill Extension О Enclosure ambient heaters SP E C S H E E T 3 OF 6 SD025 | 2.4L | 25 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency CONFIGURABLE OPTIONS Electronic Isochronous +/- 0.25% SP E C S H E E T 4 OF 6 ENGINE SPECIFICATIONS General Make Generac EPA Emissions Compliance Stationary Emergency EPA Emissions Reference See Emissions Data Sheet Cylinder # 4 Type In-Line Displacement - L (cu In) 2.4 (146.46) Bore - mm (in) 90 (3.54) Stroke - mm (in) 94 (3.70) Compression Ratio 21.3:1 Intake Air Method Turbocharged Cylinder Head Type Cast Iron Piston Type Aluminium Engine Governing Governor Frequency Regulation (Steady State) Lubrication System Oil Pump Type Gear Oil Filter Type Full Flow Crankcase Capacity - L (qts) 6.2 (6.52) Cooling System Cooling System Type Closed Recovery Water Pump Pre-Lubed, Self Sealing Fan Type Pusher Fan Speed (rpm) 2698 Fan Diameter mm (in) 560 (22) Coolant Heater Wattage 1500 Coolant Heater Standard Voltage 120 VAC Fuel System Fuel Type Ultra Low Sulfur Diesel Fuel Fuel Specifications ASTM Fuel Filtering (microns) 5 Fuel Injection Distribution Injection Pump Fuel Pump Type Engine Driven Gear Injector Type Mechanical Fuel Supply Line mm (in) 7.94 (0.31) Fuel Return Line mm (in) 7.94 (0.31) Engine Electrical System System Voltage 12 VDC Battery Charging Alternator Std Battery Size See Battery Index 0161970SBY Battery Voltage 12 VDC Ground Polarity Negative ALTERNATOR SPECIFICATIONS Standard Model 390 Poles 4 Field Type Revolving Insulation Class - Rotor H Insulation Class - Stator H Total Harmonic Distortion <5% Telephone Interference Factor (TIF) <50 Standard Excitation Synchronous Bearings Single Sealed Cartridge Coupling Direct, Flexible Disc Load Capacity - Standby 100% Prototype Short Circuit Test Yes Voltage Regulator Type Digital Number of Sensed Phases All SD025 | 2.4L | 25 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency APPLICATION AND ENGINEERING DATA Regulation Accuracy (Steady State) ±0.25% POWER RATINGS STARTING CAPABILITIES (sKVA) FUEL CONSUMPTION RATES* COOLING COMBUSTION AIR REQUIREMENTS ENGINE EXHAUST Standby Single-Phase 120/240 VAC @1.0pf 25 kW Amps: 104 Three-Phase 120/208 VAC @0.8pf 25 kW Amps: 87 Three-Phase 120/240 VAC @0.8pf 25 kW Amps: 75 Three-Phase 277/480 VAC @0.8pf 25 kW Amps: 38 Three-Phase 346/600 VAC @0.8pf 25 kW Amps: 30 sKVA vs. Voltage Dip 480 VAC 208/240 VAC Alternator kW 10% 15% 20% 25% 30% 35% 10% 15% 20% 25% 30% 35% Standard 25 16 25 33 41 49 57 12 19 25 31 37 43 Upsize 1 35 24 36 48 60 72 84 18 27 36 45 54 63 Upsize 2 40 27 41 54 68 81 95 20 31 41 51 61 71 Diesel - gal/hr (l/hr) Fuel Pump Lift - ft (m) Percent Load Standby 3 (1)25% 0.8 (3.0) 50% 1.33 (5.0) Total Fuel Pump Flow (Combustion + Return) 75% 1.67 (6.3) 4.5 gal/hr 100% 2.5 (9.5) * Fuel supply installation must accommodate fuel consumption rates at 100% load. Standby Coolant Flow per Minute gal/min (l/min) 10 (38) Coolant System Capacity gal (L) 2.8 (10.95) Heat Rejection to Coolant BTU/hr 103,080 Inlet Air cfm (m3/hr) 4,500 (7647) Max. Operating Radiator Air Temp Fº (Cº) 122 (50) Max. Ambient Temperature (before derate) Fº (Cº) 110 (43.3) Maximum Radiator Backpressure in H 2O 0.5 Standby Flow at Rated Power cfm (m3/min) 90 (2.55) Standby Rated Engine Speed rpm 1800 Horsepower at Rated kW** hp 49 Piston Speed ft/min (m/min) 1110 (338) BMEP psi 117 ** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes. Standby Exhaust Flow (Rated Output) cfm (m 3/min) 208 (354) Max. Backpressure (Post Silencer) inHg (Kpa) 1.5 (5.1) Exhaust Temp (Rated Output) ºF (ºC) 790 (421) Exhaust Outlet Size (Open Set) mm (in) 63.5 (2.5) Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards. SP E C S H E E T 5 OF 6 SD025 | 2.4L | 25 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency OPERATING DATA Part No 0K5084 Rev. E 08/19/15 Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53187 P: (262) 544-4811 © 2015 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. SP E C S H E E T 6 OF 6 Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER SD025 | 2.4L | 25 kW INDUSTRIAL DIESEL GENERATOR SET EPA Certified Stationary Emergency DIMENSIONS AND WEIGHTS* OPEN SET RUN TIME HOURS USABLE CAPACITY GAL (L) L x W x H in (mm) WT lbs (kg) - Tank & Open Set NO TANK - 76 (1930.4) x 37.4 (949.9) x 42.2 (1072.1) 2060 (934) 21 54 (204.4) 76 (1930.4) x 37.4 (949.9) x 55.2 (1402.1) 2540 (1152) 52 132 (499.7) 76 (1930.4) x 37.4 (949.9) x 67.2 (1706.9) 2770 (1257) 84 211 (798.7) 76 (1930.4) x 37.4 (949.9) x 79.2 (2011.7) 2979 (1351) 120 300 (1135.6) 92.9 (2360) x 37.4 (949.9) x 82.7 (2100.6) 3042 (1380) STANDARD ENCLOSURE RUN TIME HOURS USABLE CAPACITY GAL (L) L x W x H in (mm) WT lbs (kg) - Enclosure Only Steel Aluminum NO TANK - 94.8 (2408.9) x 38 (965.2) x 49.5 (1258.1) 302 (137) 191 (87) 54 (204.4) 94.8 (2408.9) x 38 (965.2) x 62.5 (1587.5) 132 (499.7) 94.8 (2408.9) x 38 (965.2) x 74.5 (1892.3) 211 (798.7) 94.8 (2408.9) x 38 (965.2) x 86.5 (2197.1) 300 (1135.6) 94.8 (2408.9) x 38 (965.2) x 90 (2286) LEVEL 1 ACOUSTIC ENCLOSURE RUN TIME HOURS USABLE CAPACITY GAL (L) L x W x H in (mm) WT lbs (kg) - Enclosure Only Steel Aluminum NO TANK - 112.5 (2857.1) x 38 (965.2) x 49.5 (1258.1) 455 (206) 288 (131) 54 (204.4) 112.5 (2857.1) x 38 (965.2) x 62.5 (1587.5) 132 (499.7) 112.5 (2857.1) x 38 (965.2) x 74.5 (1892.3) 211 (798.7) 112.5 (2857.1) x 38 (965.2) x 86.5 (2197.1) 300 (1135.6) 112.5 (2857.1) x 38 (965.2) x 90 (2286) LEVEL 2 ACOUSTIC ENCLOSURE RUN TIME HOURS USABLE CAPACITY GAL (L) L x W x H in (mm) WT lbs (kg) - Enclosure Only Steel Aluminum NO TANK - 94.8 (2408.9) x 38 (965.2) x 62 (1573.9) 460 (209) 291 (132) 54 (204.4) 94.8 (2408.9) x 38 (965.2) x 75 (1905) 132 (499.7) 94.8 (2408.9) x 38 (965.2) x 87 (2209.8) 211 (798.7) 94.8 (2408.9) x 38 (965.2) x 99 (2514.6) 300 (1135.6) 94.8 (2408.9) x 38 (965.2) x 102.5 (2603.5) *All measurements are approximate and for estimation purposes only. Sound dBA can be found on the sound data sheet. Enclosure Only weight is added to Tank & Open Set weight to determine total weight. 21 52 84 120 21 52 84 120 21 52 84 120