BLOWER DOOR TEST FORM
House Infiltration Test Cerd flcaidor,
Prescriptive and Performance Me€hod
Date: to permP't, -`: 110 �- —0 16 0
Contractor:
Job Address;
Cons ,ruction: I ✓) New Construction — Complete ) Existing — Ahtter Addition
House Infiltration Tesc Results SLC Clirna•-e Zone 2 r
CFM (50) = 2 0 T est Da• e: (0 1-01-0
Volune = 31 k '� 4
ACI : (50) = CFM (50) is 60 / Volurie = 3. 2 Lt M ,hanical Ventilation required less than 3 ACP1
Passing results must be & ACH (50) or less ( ) Pass ( ) Fall
F-SC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f ), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
Resident-1-al
Where the air infiitration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section P,402 a.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Comnanv
Company Name: Pro -Duct Services Address: '1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Matin Klein
License/Certification #l: 5061633
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
772-462-2165 Fax 772-462-6443
FBC ENERGY CONSERVATION CODE
Duct Sealing Certification
Prescriptive and Performance Method
Date: (� II' V 7 Permit #: ° — J I 60 Lott #�:
Contractor: l�oalr+y F'1 �► P3 Address: 5 D0Y �N�'+z. )�.� V /X' F,(_ e✓ . F� 3`F4 ``Q
Construction: Yp'ost Construction Test ❑ Rough -in Test
Test Conditions:
Date: 'LJ Floor Area (ft2):
Time: 5 » Primary Location of Supply Ductworkrc
Indoor Temperature (F): i 6 Primary Location of Return Ductwork .,-%ac
Outdoor Temperature (F):s
Total Leakage Test Outside
Duct Leakage: 4efult ❑ Prop. Leak Free ❑ Proposed On =
Test Pressure: 'L S (Pa)
Baseline Duct Pressure (optional) v. l (Pa)
Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: Pass ❑ Fail
Installed Pa
1 Total Leakage (cfm): Q U
.` Total Leakage per 100 sgft: 2 ' r 2 �"'�' �- O 'L 4)
CFM25 x 100 divided by the CFA = Duct Leakage CFM1100 sqft.
Testing Company
Company Name: Pro -Duct Services Address:
I hereby certify that the above Duct Sealing Leakage results demonstrate compliance with 5t' Edition FBC Energy Conservation requirements in accordance with
Section R403.2.2.
Signature:
Printed Name: Martin Klein License/Certificate #: 5061633
BUILDING PERFORMANCE INSTITUTE, INC.
107 Hermes Road, Suite 210
Malta, NY 12020
(877) 274-1274
www.bpi.orgPL
•
.
Martin Klein
:BPI
BPI IDO: 5061633
1nf& a0pn & Duct Leakage (IDL) 4 262021