Loading...
HomeMy WebLinkAboutBlower Test 5008Planning OR Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34902 Phoeta: 772-462-2-165 Fam 772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Cerd flcaidor, Prescriptive and Performance Me€hod Date: to permP't, -`: 110 �- —0 16 0 Contractor: Job Address; Cons ,ruction: I ✓) New Construction — Complete ) Existing — Ahtter Addition House Infiltration Tesc Results SLC Clirna•-e Zone 2 r CFM (50) = 2 0 T est Da• e: (0 1-01-0 Volune = 31 k '� 4 ACI : (50) = CFM (50) is 60 / Volurie = 3. 2 Lt M ,hanical Ventilation required less than 3 ACP1 Passing results must be & ACH (50) or less ( ) Pass ( ) Fall F-SC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f ), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Resident-1-al Where the air infiitration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section P,402 a.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Comnanv Company Name: Pro -Duct Services Address: '1915 Rio Vista Drive, Ft. Pierce, FL 34949 I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: Matin Klein License/Certification #l: 5061633 Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 772-462-2165 Fax 772-462-6443 FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method Date: (� II' V 7 Permit #: ° — J I 60 Lott #�: Contractor: l�oalr+y F'1 �► P3 Address: 5 D0Y �N�'+z. )�.� V /X' F,(_ e✓ . F� 3`F4 ``Q Construction: Yp'ost Construction Test ❑ Rough -in Test Test Conditions: Date: 'LJ Floor Area (ft2): Time: 5 » Primary Location of Supply Ductworkrc Indoor Temperature (F): i 6 Primary Location of Return Ductwork .,-%ac Outdoor Temperature (F):s Total Leakage Test Outside Duct Leakage: 4efult ❑ Prop. Leak Free ❑ Proposed On = Test Pressure: 'L S (Pa) Baseline Duct Pressure (optional) v. l (Pa) Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: Pass ❑ Fail Installed Pa 1 Total Leakage (cfm): Q U .` Total Leakage per 100 sgft: 2 ' r 2 �"'�' �- O 'L 4) CFM25 x 100 divided by the CFA = Duct Leakage CFM1100 sqft. Testing Company Company Name: Pro -Duct Services Address: I hereby certify that the above Duct Sealing Leakage results demonstrate compliance with 5t' Edition FBC Energy Conservation requirements in accordance with Section R403.2.2. Signature: Printed Name: Martin Klein License/Certificate #: 5061633 BUILDING PERFORMANCE INSTITUTE, INC. 107 Hermes Road, Suite 210 Malta, NY 12020 (877) 274-1274 www.bpi.orgPL • . Martin Klein :BPI BPI IDO: 5061633 1nf& a0pn & Duct Leakage (IDL) 4 262021 BUILDING PERFORMANCE INSTITUTE, INC.