HomeMy WebLinkAboutREVISION, energy calc 10.28.20EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 610/27/2020 1:07 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
DAVE GOLDEN HOMESJUREK RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL , 34951
TREETOP TRAIL
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
2070
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.40 352.00 ft²
SHGC=0.25
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2070.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1967.00 ft²
b. Frame - Wood, Adjacent R=11.0 410.00 ft²
c. N/A R=f t ²
10. Ceiling Types
a. Roof Deck (Unvented)R=20.0 2070.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:1.333 ft.
Area Weighted Average SHGC:0.250
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
3
(352.0 sqft.)
(2377.0 sqft.)
(2070.0 sqft.)
(2070.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
35.2 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 150
EF: 0.980
Glass/Floor Area: 0.170
Total Proposed Modified Loads:
Total Baseline Loads:
71.82
75.28 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
10-27-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
DAVE GOLDEN HOMES
1
JUREK RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
2070
3
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL , 34951
FORT PIERCE ,
St. Lucie
TREETOP TRAIL
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 2070 21573
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 CLST 3 24 240 No 0 Yes Yes1 Yes
2 BEDROOM 3 156 1560 No 0 1 Yes Yes1 Yes
3 HALL 48 480 No 0 Yes Yes1 Yes
4 BATH 2 78 780 No 0 Yes Yes1 Yes
5 BEDROOM 2 169 1690 No 0 1 Yes Yes1 Yes
6 CLST 2 26 260 No 0 Yes Yes1 Yes
7 FOYER 63 630 No 0 Yes Yes1 Yes
8 FAMILY ROOM 342 3933 No 0 Yes Yes1 Yes
9 OFFICE 154 1540 No 0 Yes Yes1 Yes
10 KITCHEN 242 2420 Yes 0 Yes Yes1 No
11 DINING 144 1439 No 0 Yes Yes1 Yes
12 MASTER BEDROO 240 2760 No 0 1 Yes Yes1 Yes
13 M WIC 96 960 No 0 Yes Yes1 Yes
14 M TOILET 25 250 No 0 Yes Yes1 Yes
15 M BATH 119 1190 No 0 Yes Yes1 Yes
16 M HALL 28 280 No 0 Yes Yes1 No
17 LAUNDRY 102 1020 No 0 Yes Yes1 No
18 PANTRY 14 140 No 0 Yes Yes1 No
10/27/2020 1:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 24 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014 ft CLST 3
2 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -013 ft BEDROOM 3
3 48 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -04 ft HALL
4 78 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -019 ft BATH 2
5 169 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -013 ft BEDROOM 2
6 26 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft CLST 2
7 63 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft FOYER
8 342 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -017 ft FAMILY ROOM
9 154 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -018 ft OFFICE
10 242 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft KITCHEN
11 144 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -024 ft DINING
12 240 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -021 ft MASTER BEDRO
13 96 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -022 ft M WIC
14 25 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft M TOILET
15 119 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft M BATH
16 28 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M HALL
17 102 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LAUNDRY
18 14 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft PANTRY
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Metal 2315 ft² Light 0.1 20 26.6______No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 2070 ft² N N0
10/27/2020 1:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented)0 24 ft² 0.1 Wood______CLST 3 Blown
2 Under Attic (Unvented)0 156 ft² 0.1 Wood______BEDROOM 3 Blown
3 Under Attic (Unvented)0 48 ft² 0.1 Wood______HALL Blown
4 Under Attic (Unvented)0 78 ft² 0.1 Wood______BATH 2 Blown
5 Under Attic (Unvented)0 169 ft² 0.1 Wood______BEDROOM 2 Blown
6 Under Attic (Unvented)0 26 ft² 0.1 Wood______CLST 2 Blown
7 Under Attic (Unvented)0 63 ft² 0.1 Wood______FOYER Blown
8 Under Attic (Unvented)0 342 ft² 0.1 Wood______FAMILY ROOM Blown
9 Under Attic (Unvented)0 154 ft² 0.1 Wood______OFFICE Blown
10 Under Attic (Unvented)0 242 ft² 0.1 Wood______KITCHEN Blown
11 Under Attic (Unvented)0 144 ft² 0.1 Wood______DINING Blown
12 Under Attic (Unvented)0 240 ft² 0.1 Wood______MASTER BEDRO Blown
13 Under Attic (Unvented)0 96 ft² 0.1 Wood______M WIC Blown
14 Under Attic (Unvented)0 25 ft² 0.1 Wood______M TOILET Blown
15 Under Attic (Unvented)0 119 ft² 0.1 Wood______M BATH Blown
16 Under Attic (Unvented)0 28 ft² 0.1 Wood______M HALL Blown
17 Under Attic (Unvented)0 102 ft² 0.1 Wood______LAUNDRY Blown
18 Under Attic (Unvented)0 14 ft² 0.1 Wood______PANTRY Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0CLST 3 0002 10S Concrete Block - Int Insul 0.10Exterior20.0 ft² ____
2 4.1 0CLST 3 00012 10W Concrete Block - Int Insul 0.10Exterior120.0 ft² ____
3 4.1 0BEDROOM 3 00013 10S Concrete Block - Int Insul 0.10Exterior130.0 ft² ____
4 4.1 0HALL0004 10S Concrete Block - Int Insul 0.10Exterior40.0 ft² ____
5 4.1 0BATH 2 0006 10E Concrete Block - Int Insul 0.10Exterior60.0 ft² ____
6 4.1 0BATH 2 00013 10S Concrete Block - Int Insul 0.10Exterior130.0 ft² ____
7 4.1 0BEDROOM 2 00013 10E Concrete Block - Int Insul 0.10Exterior130.0 ft² ____
8 4.1 0CLST 2 0004 10N Concrete Block - Int Insul 0.10Exterior40.0 ft² ____
9 4.1 0CLST 2 0002 10E Concrete Block - Int Insul 0.10Exterior20.0 ft² ____
10 4.1 0FOYER0007 10E Concrete Block - Int Insul 0.10Exterior70.0 ft² ____
11 4.1 0FAMILY ROO 06017 11W Concrete Block - Int Insul 0.10Exterior195.5 ft² ____
12 4.1 0OFFICE00014 10E Concrete Block - Int Insul 0.10Exterior140.0 ft² ____
13 4.1 0OFFICE0004 10S Concrete Block - Int Insul 0.10Exterior40.0 ft² ____
14 11 0OFFICE00011 10N Frame - Wood 0.10.1Garage110.0 ft² ____
15 11 0KITCHEN0005 10N Frame - Wood 0.10.1Garage50.0 ft² ____
16 4.1 0DINING00011 10S Concrete Block - Int Insul 0.10Exterior110.0 ft² ____
17 4.1 0DINING00013 10W Concrete Block - Int Insul 0.10Exterior130.0 ft² ____
18 4.1 0MASTER BE 0606 11S Concrete Block - Int Insul 0.10Exterior69.0 ft² ____
19 4.1 0MASTER BE 06015 11W Concrete Block - Int Insul 0.10Exterior172.5 ft² ____
20 4.1 0M WIC 00016 10N Concrete Block - Int Insul 0.10Exterior160.0 ft² ____
21 4.1 0M WIC 0006 10W Concrete Block - Int Insul 0.10Exterior60.0 ft² ____
22 4.1 0M TOILET 0006 10N Concrete Block - Int Insul 0.10Exterior60.0 ft² ____
10/27/2020 1:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
23 4.1 0M BATH 0007 10N Concrete Block - Int Insul 0.10Exterior70.0 ft² ____
24 11 0M BATH 00011 10E Frame - Wood 0.10.1Garage110.0 ft² ____
25 11 0LAUNDRY00010 10E Frame - Wood 0.10.1Garage100.0 ft² ____
26 11 0PANTRY0004 10N Frame - Wood 0.10.1Garage40.0 ft² ____
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 S Low-E Single 0.4 0.25 18.0 ft² 1 ft 4 in 1 ft 4 in NoneVinyl None______Yes3 N
2 E Low-E Single 0.4 0.25 6.0 ft² 1 ft 4 in 1 ft 4 in NoneVinyl None______Yes5 N
3 E Low-E Single 0.4 0.25 36.0 ft² 1 ft 4 in 1 ft 4 in NoneVinyl None______Yes7 N
4 E Low-E Single 0.4 0.25 16.0 ft² 1 ft 4 in 1 ft 4 in NoneVinyl None______Yes10 N
5 E Low-E Single 0.4 0.25 24.0 ft² 1 ft 4 in 1 ft 4 in NoneVinyl None______Yes10 N
6 W Low-E Single 0.4 0.25 96.0 ft² 1 ft 4 in 1 ft 4 in NoneVinyl None______Yes11 N
7 E Low-E Single 0.4 0.25 36.0 ft² 1 ft 4 in 1 ft 4 in NoneVinyl None______Yes12 N
8 S Low-E Single 0.4 0.25 36.0 ft² 1 ft 4 in 1 ft 4 in NoneVinyl None______Yes16 N
9 W Low-E Single 0.4 0.25 36.0 ft² 1 ft 4 in 1 ft 4 in NoneVinyl None______Yes17 N
10 S Low-E Single 0.4 0.25 18.0 ft² 1 ft 4 in 1 ft 4 in NoneVinyl None______Yes18 N
11 W Low-E Single 0.4 0.25 24.0 ft² 1 ft 4 in 1 ft 4 in NoneVinyl None______Yes19 N
12 N Low-E Single 0.4 0.25 6.0 ft² 1 ft 4 in 1 ft 4 in NoneVinyl None______Yes23 N
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 462 ft² 462 ft² 41 ft 10 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1797.7 598.69.000331Wholehouse .1275185.6Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 35.2 kBtu/hr 1056 cfm 0.8______sys#1Split1 Single
10/27/2020 1:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 150 ft² Attic 15 ft² Default Leakage LAUNDRY (Default) c______1 1 (Default) c
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 KITCHEN DINING
Default(8 lbs/sq.ft.f t ² f t 0.3 GREAT ROOM
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 3
Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY
Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 GALLERY
Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
Default(8 lbs/sq.ft.f t ² f t 0.3 HER WIC
Default(8 lbs/sq.ft.f t ² f t 0.3 HIS WIC
Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 CABANA
10/27/2020 1:07 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������