HomeMy WebLinkAboutA-1-REBUILD-DECKSHEET NO.TRUSSES:DRAWN BY:OWNER'S SIGNATURE DATEOWNER REVIEW ACKNOWLEDGEMENTCOMMUNITY:OWNER'S SIGNATURE OWNERS:DATE 9/16/2019 DATE:GG A-1ENGINEER #:N/AACCUBLEND CONCRETE DESIGN Port St Lucie Fl 34953LOT ENGINEER :DATE:NOTE: WHEN PLANS ARE PRINTED ON 11"x 17"SHEETS, EVERYTHING IS REDUCED BY 50%. (e.g.1/4" SCALE BECOMES 1/8" SCALE.REVISED:REVISED:Joseph Simmons P.E.10/06/2020 52101
DE
S
I
G
N
S
T
A
T
E
M
E
N
T
:
TH
I
S
S
T
R
U
C
T
U
R
E
H
A
S
B
E
E
N
D
E
S
I
G
N
E
D
T
O
M
E
E
T
O
R
E
X
C
E
E
D
T
H
E
W
I
N
D
L
O
A
D
IN
D
I
V
I
D
U
A
L
D
E
S
I
G
N
D
R
A
W
I
N
G
S
S
H
O
W
S
P
E
C
I
A
L
L
O
A
D
I
N
G
C
O
N
D
I
T
I
O
N
S
:
DE
S
I
G
N
C
O
D
E
:
F
B
C
2
0
1
4
/
T
P
1
2
0
0
7
WI
N
D
C
O
D
E
:
A
S
C
E
7
-
1
0
{
A
L
L
H
E
I
G
H
T
}
W
I
N
D
S
P
E
E
D
:
1
6
0
M
P
H
RO
O
F
L
O
A
D
:
4
0
.
0
P
S
F
F
L
O
O
R
L
O
A
D
:
N
/
A
P
S
F
A-
1
PR
O
J
E
C
T
I
N
D
E
X
I
N
F
O
R
M
A
T
I
O
N
,
S
P
E
C
,
P
R
O
D
,
A
P
P
R
O
V
A
L
A-
2
DE
C
K
D
E
M
O
L
I
S
I
O
N
L
A
Y
O
U
T
P
L
A
N
/
R
E
B
U
I
L
T
D
E
C
K
1 414
Jo
h
n
P
a
u
l
E
d
g
a
r
55
1
2
P
i
n
e
T
r
e
e
D
r
i
v
e
Ft
.
P
i
e
r
c
e
F
l
o
r
i
d
a
,
3
4
9
8
2
-
7
5
6
9
IN
D
E
X
O
F
D
R
A
W
I
N
G
S
SQUARE FOOTAGE SECOND FLOOD DECK 168 SQ.FT TOTAL RENOVATED DECK
1
6
8
S
Q
.
F
T
DE
S
I
G
N
P
A
R
A
M
E
T
E
R
:
20
1
7
F
L
O
R
I
D
A
R
E
S
I
D
E
N
T
I
A
L
B
U
I
L
D
I
N
G
C
O
D
E
,
6
t
h
E
D
I
T
I
O
N
BU
I
L
D
I
N
G
D
E
S
I
G
N
:
F
R
A
M
E
D
O
P
E
N
D
E
C
K
UL
T
I
M
A
T
E
W
I
N
D
S
P
E
E
D
:
1
5
0
M
P
H
3
S
E
C
O
N
D
G
U
S
T
Ar
c
h
i
t
e
c
t
u
r
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
Ge
n
e
r
a
l
S
c
o
p
e
o
f
W
o
r
k
:
1.
M
A
T
E
R
I
A
L
S
A
N
D
M
E
T
H
O
D
S
O
F
C
O
N
S
T
R
U
C
T
I
O
N
S
S
H
A
L
L
C
O
N
F
O
R
M
T
O
T
H
E
R
E
Q
U
I
R
E
M
E
N
T
S
O
F
T
H
E
C
I
T
Y
O
F
F
T
.
P
I
E
R
C
E
FL
O
R
I
D
A
,
A
N
D
T
H
E
F
L
O
R
I
D
A
R
E
S
I
D
E
N
T
I
A
L
B
U
I
L
D
I
N
G
C
O
D
E
2
0
1
7
,
6
T
H
E
D
I
T
I
O
N
.
2.
S
C
O
P
E
O
F
W
O
R
K
I
N
C
L
U
D
E
S
:
a)
R
E
M
O
V
E
A
L
L
R
O
T
T
E
D
W
O
O
D
S
U
P
P
O
R
T
B
E
A
M
S
,
W
H
I
C
H
I
N
C
L
U
D
E
S
T
H
E
W
O
O
D
B
A
L
C
O
N
Y
A
N
D
E
L
E
C
T
R
I
C
F
A
N
RE
P
L
A
C
E
A
N
D
R
E
B
U
I
L
D
W
O
O
D
D
E
C
K
B
A
L
C
O
N
Y
.
A
N
D
A
D
D
(
3
)
E
X
T
E
R
I
O
R
F
A
N
PA
I
N
T
A
N
D
R
E
F
I
N
I
S
H
T
O
M
A
T
C
H
E
X
I
S
T
I
N
G
F
I
N
I
S
H
O
W
N
E
R
S
C
H
O
I
C
E
WO
O
D
1.
P
L
Y
W
O
O
D
:
A
P
A
E
X
P
-
1
,
C
D
X
.
R
O
O
F
S
H
E
A
T
H
I
N
G
S
E
L
F
A
D
H
E
A
S
I
V
E
W
A
T
E
R
P
R
O
O
F
R
O
L
L
:
3
/
4
"
P
L
Y
W
O
O
D
2.
L
U
M
B
E
R
:
F
U
R
R
I
N
G
&
B
L
O
C
K
I
N
G
:
D
O
U
G
L
A
S
F
I
R
-
L
A
R
C
H
,
H
E
M
-
F
I
R
,
S
O
U
T
H
E
R
N
P
I
N
E
,
N
O
.
2
O
R
B
E
T
T
E
R
,
M
A
X
.
M
O
I
S
T
U
R
E
CO
N
T
E
N
T
.
U
S
E
P
R
E
S
S
U
R
E
T
R
E
A
T
E
D
W
H
E
R
E
N
O
T
E
D
A
N
D
O
R
R
E
Q
U
I
R
E
D
A
N
D
I
D
E
N
T
I
F
I
E
D
P
E
R
F
B
C
2
3
0
3
.
1
.
8
.
1
.
3.
F
R
A
M
I
N
G
A
N
C
H
O
R
S
:
S
I
M
P
S
O
N
G
A
L
V
A
N
I
Z
E
D
,
W
/
A
L
L
N
A
I
L
S
,
S
C
R
E
W
S
A
S
S
C
H
E
D
U
L
E
D
,
4.
A
N
C
H
O
R
A
D
H
E
S
I
V
E
:
S
I
M
P
S
O
N
A
T
A
C
R
Y
L
I
C
-
T
I
E
,
2
C
O
M
P
O
N
E
N
T
,
C
A
T
.
P
A
.
6
9
PA
R
T
Pr
o
d
u
c
t
Mo
d
e
l
#
M
a
n
u
f
a
c
t
u
r
e
r
Glass Description
S
i
z
e
,
S
p
a
c
i
n
g
E
m
b
e
d
m
e
n
t
(psi)(Fyb )Product Design Pressure (psf)
1
SI
M
P
S
O
N
H
U
S
2
1
0
-
4
CO
N
C
E
A
L
E
D
F
L
A
N
G
E
HU
S
2
1
0
-
4
FL
#
1
0
5
3
1
-
1
1
SIMPSON STRONG-TIE 2151 SOUTH AIRPORT DRIVE McKINNEY, TX 75069N/A0.148" x 3 1/4" nails may be used where 0.148" x 3" nails are specified with no reduction in load. Where 0.162" x 3 1/2"nails are specified, 0.148" x 3" or 0.148" x 3 1/4" nails may be used at 0.85 of the table load.N/A
N
/
A
2
SI
M
P
S
O
N
A
B
U
6
6
P
O
S
T
MO
U
N
T
AB
U
6
6
FL
#
1
0
8
6
0
.
2
SIMPSON STRONG-TIE 2151 SOUTH AIRPORT DRIVE McKINNEY, TX 75069N/AInstallation:xABA, ABU - for pre-pour installed anchors. For Simpson Strong-Tie epoxy or mechanical anchors,select and install in accordance with www.strongtie.com.xProducts require washers between the nut and the base. Washers are supplied with the ABU but not the ABA, which requires a standard cut washer.90,000 90,000 N/A
3
SI
M
P
S
O
N
P
C
6
Z
PC
6
Z
FL
#
1
0
8
6
0
.
2
8
SIMPSON STRONG-TIE 2151 SOUTH AIRPORT DRIVE McKINNEY, TX 75069N/APCZ/EPCZ post caps are designed with their post and beam flanges in-line so that one PCZ/EPCZ model can accommodate several post sizes. The PCZ/EPCZ uses 0.148" x 3" nails. An alternate choice of fastener is the #9 x 1 1/2" Strong-Drive®SD Connector screw. ZMAX® finish is standard to meet exposure conditions in many environments.N/A
N
/
A
4
SI
M
P
S
O
N
H
U
S
2
1
0
-
2
FL
A
N
G
E
HU
S
2
1
0
-
2
FL
#
1
0
6
5
5
.
1
1
SIMPSON STRONG-TIE 2151 SOUTH AIRPORT DRIVE McKINNEY, TX 75069N/A0.148" x 3 1/4" nails may be used where 0.148" x 3" nails are specified with no reduction in load. Where 0.162" x 3 1/2"nails are specified, 0.148" x 3" or 0.148" x 3 1/4" nails may be used at 0.85 of the table load.N/A
N
/
A
5
WE
A
T
H
E
R
A
B
L
E
S
VI
N
Y
L
R
A
I
L
I
N
G
CW
R
-
R
3
6
-
E
8
HOME DEPOT WEATHERABLES GROVEPORT, OHN/A
N
/
A
N
/
A
6
SE
L
F
A
D
H
E
A
S
I
V
E
WA
T
E
R
P
R
O
O
F
R
O
L
L
50
0
3
0
0
2
NO
A
#
1
5
-
0
7
2
8
.
1
1
FL
2
8
9
-
R
3
HOME DEPOT GCP APPLIED TECHNOLOGY 62 WHITTENMORE AVENUE CAMBRIDGE MA 02140THICKNESS 40 MIL––––N/A
N
/
A
RI
S
K
C
A
T
E
G
O
R
Y
:
I
I
IN
T
E
R
N
A
L
P
R
E
S
S
U
R
E
C
O
E
F
F
I
C
I
E
N
T
:
+
/
-
0
.
1
8
BU
I
L
D
I
N
G
M
E
A
N
H
E
I
G
H
T
:
N
/
A
RO
O
F
O
V
E
R
H
A
N
G
:
N
/
A
RO
O
F
P
I
T
C
H
:
N
/
A
CO
N
S
T
R
U
C
T
I
O
N
:
FR
A
M
E
D
D
E
C
K
AR
E
A
T
A
B
U
L
A
T
I
O
N
S
RE
B
U
I
L
D
R
O
T
T
E
D
D
E
C
K
A
R
E
A
:
1
6
8
S
Q
.
F
T
.
TO
T
A
L
:
1
6
8
S
Q
.
F
T
.
5512 Pine Tree Drive Fort Pierce, Florida
Di
l
a
p
i
d
a
t
e
d
S
e
c
o
n
d
Fl
o
o
r
D
e
c
k
R
e
b
u
i
l
d
S-
1
SI
T
E
P
L
A
N