Loading...
HomeMy WebLinkAboutRevision - revisied engery calcs OFFICE USE ONLY: DATE FILED: PERMIT# 2 005 REVISION FEE: ' ` o � S RECEIPT# PLANNING&DEVELOPMENT SERVICES BUILDING&CODE REGULATION DMSION 2300 VIRGINIA AVENUE FORT PIERCE,FL 34982-5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: ) / .0 �' Z ?c i�y L `J c DETAILED DESCRIPTION OF PROJECT REVISIONS: ( / CONTRACTOR INFORMATION: STATE of FL REG./CERT.#: -7 Sal 2 ST.LUCIE CO CERT.#: BUSINESS NAME: `�c�e,.c .S cu- i-p,—e s Z t C1 QUALIFIERS NAME: e• ADDRESS: 2c, ' Sw i F e_ CITY: e S L_ STATE: F�, ZIP: PHONE(DAYTIME): `?'? 2 3 7 �-,S-! Z FAX: OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: STATE: PHONE(DAYTIME: FAX: f ARCHITECT/ENGINEER INFOR//MATION: NAME: ADDRESS: CITY: 214 54 Lvc-c STATE: rZ ZIP: PHONE(DAYTIME):• ' = ' �'�r' FAX: SLCCC. 9123109 Revised 06130/17 t� :.i FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Montoya Residence Builder Name: Dansar Homes Street: 2802 Grove Street Permit Office: St. Lucie County City,State,Zip: Fort Pierce,FL,34981 Permit Number: Owner: Montoya Residence Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1746.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block-Int Insul, Exterior R=4.1 1447.50 ftz b. Frame-Wood,Adjacent R=19.0 177.33 ftz 3. Number of units,if multiple family 1 c. Frame-Wood,Adjacent R=11.0 121.33 ft' 4. Number of Bedrooms 3 d. N/A R= ftZ 5. Is this a worst case? No 10.Ceiling Types (1614.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1614.00 ftz 6. Conditioned floor area above grade(ftz) 1614 b. N/A R= ftz Conditioned floor area below grade(ftz) 0 c.Duct R= ftz 11. Duucts R ftz 7. Windows(125.8 sqft.) Description Area a. Sup:Attic,Ret:Attic,AH:Garage 6 105 a. U-Factor: Sgl,U=0.65 125.80 ftz SHGC: SHGC=0.25 b. U-Factor: N/A ftz 12.Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 30.0 SEER:15.75 c. U-Factor: N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Strip Heat 27.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems 8. Floor Types (1614.0 sqft.) Insulation Area a. Electric Tankless Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 1614.00 ft' b. Conservation features EF:0.950 b. N/A R= ft' None c. N/A R= ft2 15.Credits CF Pstat Glass/Floor Area: 0.078 Total Proposed Modified Loads: 54.28 PASS Total Baseline Loads: 56.51 1 hereby certify that the plans and specifications covered by Review of the plans and OFTNE ST,41, this calculation are in compliance with the Florida Energy specifications covered by this ti Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed _ -- DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. � FILE COP Op�,�v OWNER/AGENT: BUILDING OFFICIAL. DATE: DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as ,,�� ,,� hg2z certified factory-sealed in accordance with R403.3.2.1. ! - V -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1 ilLVIEWIED FOR CODE COMPLIANCe g t� ST. LUCIIECOUNT; 10/15/2020 9:13 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant S Jb��( G Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Montoya Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1614 Lot# Owner Name: Montoya Residence Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Dansar Homes Rotate Angle: 0 Street: 2802 Grove Street Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City,State,Zip: Fort Pierce, Family Type: Single-family FL, 34981 New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V/ Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1614 15475.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Bedroom 3 245 2303 No 1 1 1 Yes Yes Yes 2 Bath 2 66 620.4 No 0 1 Yes Yes Yes 3 Bedroom 2 201 1889.4 No 1 1 1 Yes Yes Yes 4 Kitchen 224 2105.6 Yes 2 1 Yes Yes Yes 5 Dining 64 601.6 No 0 1 Yes Yes Yes 6 Master Bedroom 304 3161.6 No 2 1 1 Yes Yes Yes 7 Master Bath 84 789.6 No 0 1 Yes Yes Yes 8 Laundry 49 460.6 No 0 1 No Yes Yes 9 Great Room 340 3196 No 2 1 Yes Yes Yes 10 Hall 37 347.8 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Bedroom 3 33 ft 245 ft2 __-- 1 0 0 2 Slab-On-Grade Edge Insulatio Bath 2 6 ft 66 ft2 ____ 1 0 0 3 Slab-On-Grade Edge Insulatio Bedroom 2 34 ft 201 ft2 1 0 0 4 Slab-On-Grade Edge Insulatio Kitchen loft 224 ft2 ____ 1 0 0 5 Slab-On-Grade Edge Insulatio Dining 8 ft 64 ft2 1 0 0 6 Slab-On-Grade Edge Insulatio Master Bedroom 35 ft 304 ft2 _--- 1 0 0 7 Slab-On-Grade Edge Insulatio Master Bath 7 ft 84 ft2 ____ 1 0 0 10/15/2020 9:13 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab-On-Grade Edge Insulatio Laundry 1 ft 49 ft2 1 0 0 9 Slab-On-Grade Edge Insulatio Great Room 17 ft 340 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio Hall 1 ft 37 ft2 _-__ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1748 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 22.6 / ATTIC v # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1614 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Bedroom 3 30 Batt 245 ft2 0.1 Wood 2 Under Attic(Vented) Bath 2 30 Batt 66 ft2 0.1 Wood 3 Under Attic(Vented) Bedroom 2 30 Batt 201 ft2 0.1 Wood 4 Under Attic(Vented) Kitchen 30 Batt 224 ft2 0.1 Wood 5 Under Attic(Vented) Dining 30 Batt 64 ft2 0.1 Wood 6 Under Attic(Vented) Master Bedroom 30 Batt 304 ft2 0.1 Wood 7 Under Attic(Vented) Master Bath 30 Batt 84 ft2 0.1 Wood 8 Under Attic(Vented) Laundry 30 Batt 49 ft2 0.1 Wood 9 Under Attic(Vented) Great Room 30 Batt 340 ft2 0.1 Wood 10 Under Attic(Vented) Hall 30 Batt 37 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block-Int InsuBedroom 3 4.1 13 0 9 5 122.4 ft2 0 0 0.4 0 2 W Exterior Concrete Block-Int InsuBedroom 3 4.1 20 0 9 5 188.3 ft2 0 0 0.4 0 3 W Exterior Concrete Block-Int Insul Bath 2 4.1 6 0 9 5 56.5 ft2 0 0 0.4 0 4 E Exterior Concrete Block-Int InsuBedroom 2 4.1 5 0 9 5 47.1 ft2 0 0 0.4 0 5 S Exterior Concrete Block-Int InsuBedroom 2 4.1 14 0 9 5 131.8 ft2 0 0 0.4 0 6 W Exterior Concrete Block-Int InsuBedroom 2 4.1 15 0 9 5 141.3 ft2 0 0 0.4 0 7 N Exterior Concrete Block-Int Insul Kitchen 4.1 10 0 9 5 94.2 ft2 0 0 0.4 0 8 N Exterior Concrete Block-Int Insul Dining 4.1 8 0 9 5 75.3 ft2 0 0 0.4 0 9 N Exterior Concrete Block-Int InsMaster Bedro 4.1 19 0 10 5 197.9 ft2 0 0 0.4 0 10 E Exterior Concrete Block-Int InsMaster Bedro 4.1 16 0 10 5 166.7 ft2 0 0 0.4 0 11 E Exterior Concrete Block-Int InsWaster Bath 4.1 7 0 9 5 65.9 ft2 0 0 0.4 0 12 S Exterior Concrete Block-Int InsdBreat Room 4.1 17 0 9 5 160.1 ft2 0 0 0.4 0 10/15/2020 9:13 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below it Ornt Tn Wall T-YPP 13 N Garage Frame-Wood Master Bath 19 12 9 4 112.0 ft2 0.23 0.4 0 14 N Garage Frame-Wood Laundry 19 7 9 4 65.3 ft2 0.23 0.4 0 15 W Garage Frame-Wood Great Room 11 13 9 4 121.3 ft2 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Great Room None .39 3 6 10 20.5 ft2 2 S Wood Great Room None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang v # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 0 in 0 ft 5 in None None 2 S 5 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft 0 in 0 ft 5 in None None 3 N 7 Metal Low-E Single Yes 0.65 0.25 N 40.8 ft2 1 ft 0 in 0 ft 5 in None None 4 N 9 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 0 in 0 ft 5 in None None 5 E 11 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 0 in 0 ft 5 in None None 6 S 12 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft 0 in 0 ft 5 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 399 ft2 399 ft2 32 ft 9.4 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000366 1547.6 84.96 159.78 .1362 6 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15.75 30 kBtu/hr 900 cfm 0.7 1 sys#1 10/15/2020 9:13 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.95 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply--- —Return---- Air CFM 25 CFM25 HVAC# V/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 105 ft2 Attic 35 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r May rl Jun Jul n Aug rl Se Oct Nov Dec Heatin Jan lX Feb X Mar f Apr I May Jun f Jul AuSeP Oct Nov H Dec Ventin Jan [ Feb X Mar [X A r May Jun [ Jul Aug Se [X]Oct HX Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room Default(8 Ibs/s .ft. ft2 ft 0.3 Hall 10/15/2020 9:13 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Montoya Residence Builder Name: Dansar Homes Street: 2802 Grove Street Permit Office: St. Lucie County City, State,Zip: Fort Pierce, FL,34981 Permit Number: Y 0 Owner: Montoya Residence Jurisdiction: St. Lucie County w Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and an gaps in the air barrier shall be sealed. Y 9 P shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend i in and winna. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire r nkl r cover ulates and walls or ceilinas. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 10/15/2020 9:14 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location &insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Garage 3. No. of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 30.0 a)Split system SEER 15.8 5. Is this a worst case?(yes/no) 5. No b)Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area(sq. ft.) 6. 1614 d) Room unit/PTAC EER e)Other 7.Windows, type and area a)U-factor,(weighted average) 7a. 0.650 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.250 14. Heating system: Capacity 27.0 c)Area 7c. 125.8 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE f)Other 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised (R-value) 9b. 15. Water heating system c)Concrete, raised(R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10. Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1. Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f)Heat recovery unit HeatRec% B.Adjacent: g)Other 1. Wood frame(Insulation R-value) 1061. varies 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed(Performance Method) 11. Ceiling type and insulation level a)Ceiling fans Yes a)Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11b. c)Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d)Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: �--��� Date: Q /!o Address of New Home: 2802 Grove Street City/FL Zip: Fort Pierce, FL 34981 10/15/2020 9:14:41 PM EnergyGaugeO USA 6.0.04(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1