HomeMy WebLinkAboutCompaction TestPort St. Lucle
FBPE CA # 4930
607 NW Commodity Cove
Port SL Lucie, FL 34986
Phone: 772-924-35751 Fax: 772-924-3580
Soil Nuclear Gauge
Report Date: 10/28/2020
Test Method: ASTM D 6938
Client:
James Weir, Inc.
P.O. Box 1638
Palm City, FL 34991
19-3888.00
James Weir, Inc. 2019 Master Agreement
North Palm Beach, Martin, Saint Lucie
Indian River, Okeechobee and Brevard
counties...
FL
` 11111111/////
HN KF .,
�•'�1GENSF
mak'
o63218
Kent,
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1
Test Results
--
In Place
In Place
Optimum Maximum
In Place
Dry
Wet
Probe
Min/Max
Retest
Test
Soil Moisture Dry Density
Moisture
Density
Density
Depth Percent
Comp.
Test#
Of
Date ProctorlD Method
Classification I%) (pcf)
(°/,)
(pcf)
(pcf)
(in) Compaction
I%) I
Remark
7
10/27/20 P-1
N/A 10.8 115.2
11.1
113.3
125.9
12 98
98/105
Pass
8
10/27/20 P-1
N/A 10.8 115.2
10.9
113.8
126.2
12 99
98/105
Pass
Test Information
Gauge
Test #
Test Location
Elevation
Reference
Make / Model I SNI Calibrated
Field Technician
7
Backfill: Lot 901, 10701 S Ocean Drive, Jensen Beach, Permit # SLC -2008-0316,
0-1'
Troxler / 3430 / P-34784 /
Stone, Brent
Stem Wall Backfill, Back Yard, East Section
8
Backfill: Lot 901, 10701 S Ocean Drive, Jensen Beach, Permit # SLC -2008-0316,
0-1'
Troxler / 3430 / P-34784 /
Stone, Brent
Stem Wall Backfill, Back Yard, West Section
Remarks
Comments
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
7, 8: 1-2' HCP=40+, > 95 % Compaction, PASS. HCP tests are
empirically correlated to the relative density of the soil.
` 11111111/////
HN KF .,
�•'�1GENSF
mak'
o63218
Kent,
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1