Loading...
HomeMy WebLinkAboutMAKROLON POLYCARBONATE TESTING DATAM IAM I -RADE MIAMI-DADE COUNTY # PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Bayer MaterialScience LLC (MA) 119 Salisbury Road Sheffield, MA 01257 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Makrolon Polycarbonate Sheets APPROVAL DOCUMENT: Drawing No. G08-01, titled "Polycarbonate Sheets ", sheet 1 of 1, dated 09/12/2008, with revision B dated 05/11/2012, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: None LABELING: Each sheet shall bear a permanent label with the manufacturer's name or logo, city, state, model/series and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA # 10-0329.03 and consists of this page I and evidence page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 12-0605.05 Expiration Date: August 27, 2017 !,r/; �l Z Approval Date: December 6, 2012 Page 1 Bayer MaterialScience LLC (MA) NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. G08-01, titled "Polycarbonate Sheets", sheet 1 of 1, dated 09/12/2008, with revision B dated 05/11/12, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. I� TESTS Report No. Test Date 1. B2577.01-106.31 ASTM D 1929/2843/63 5/63 8 04/27/12 ASTM D2565 "Submitted under NOA # 08-0926.15" 2. 72305.01-106-18 ASTM D1929/2843/635/638 08/06/08 3. 72305.02-106-18 4. 72305.03-106-18 5. 72305.04-106-18 6. 72305.05-106-18 8. 72305.06-106-18 9. 72305.07-106-18 10. 72305.08-106-18 C. CALCULATIONS 1. None. 113 E. ASTM G155 ASTM D1929/2843/635 ASTM D1929/2843/635 ASTM D1929/2843/635 ASTM D1929/2843/635 ASTM D1929/2843/635 ASTM D1929/2843/635 ASTM D1929/2843/635 Seal & Signature G. T. Hartman, P.E. Joseph A. Reed, P.E. 08/19/08 Joseph A. Reed, P.E. 08/21/08 Joseph A. Reed, P.E. 08/21/08 Joseph A. Reed, P.E. 08/22/08 Joseph A. Reed, P.E. 08/26/08 Joseph A. Reed, P.E. 08/26/08 Joseph A. Reed, P.E. 08/26/08 Joseph A. Reed, P.E. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to 2010 FBC and no financial interest issued by Al-Farooq Corporation, dated 05/18/2012, signed and sealed by Javad Ahmad, P.E. 2. Certificate of merger of Sheffield Plastics Inc, and Bayer MaterialScience LLC, dated 03/31/2009. arlos M. Utrera, P.E. Product Control Examiner NOA No. 12-0605.05 Expiration Date: August 27, 2017 Approval Date: December 6, 2012 E -1 PRODUCT PROPERTIES * WEATHERING PER SECTION 2612 OF FLORIDA BLDG. CODE 2010. PRODUCT PROPERTIES GP- GENERAL PURPOSE SL- ENHANCED UV PROTECTION AR- ABRASION AND UV RESISTANT 15- LONG TERM WEATHERABLE POLYCARBONATE SHEETS CAN BE CLEAR OR COLORED WITH POLISHED, MATTE OR TEXTURED SURFACES. TEST DESCRIPTION TEST METHOD TEST RESULTS MAKROLON HYGARD ® SHEET INTERLAYER TEST RESULTS CG 750 .780 OVERALL THICKNESS BR 1000 EX 1000 1.05 OVERALL " THICKNESS BR 1250 EX 1250 BR 750 1.30 OVERALL .775 OVERALL " THICKNESS THICKNESS MS 1250 EX 1300 1.30„ OVERALL THICKNESS SELF IGNITION TEMP. ASTM D1929 MAKROLON® POLYCARBONATE SHEET 896'F 878'F 896'F FLASH IGNITION TEMP. ASTM D1929 SL 806'F 15 824'F 680'F 698'F SMOKE DENSITY RATING (MAX.) GP GP UV AR EX 45% 50.6% TEST 1/32" 1/16" TO 1/2" 1/8" TO 1/2" 1/8" TO 1/2" 1/8° TO 1/2" TEST DESCRIPTION METHOD THICKNESS THICKNESS THICKNESS THICKNESS THICKNESS SELF IGNITION TEMP. ASTM D1929 10227 10407 1022'F 10407 10587 FLASH IGNITION TEMP. ASTM D1929 824'F 8247 8247 8067 8427 SMOKE DENSITY RATING (MAX.) ASTM 2843 43.7% 69.4% 57.7% 50.9% 51.5% AVERAGE RATE OF BURNING ASTM D635 -- -- -- -- -- BURNING RATE CLASS ASTM D635 CC2 CC1 CC1 CC1 CC1 TENSILE STRENGTH (MEAN) ASTM D638 8986 9071 PSI PSI * BEFORE AFTER * WEATHERING PER SECTION 2612 OF FLORIDA BLDG. CODE 2010. PRODUCT PROPERTIES GP- GENERAL PURPOSE SL- ENHANCED UV PROTECTION AR- ABRASION AND UV RESISTANT 15- LONG TERM WEATHERABLE POLYCARBONATE SHEETS CAN BE CLEAR OR COLORED WITH POLISHED, MATTE OR TEXTURED SURFACES. TEST DESCRIPTION TEST METHOD TEST RESULTS MAKROLON HYGARD ® SHEET INTERLAYER CG 500 CG 375 EX 500 .390 OVERALL .530 OVERALL " THICKNESS THICKNESS CG 750 .780 OVERALL THICKNESS BR 1000 EX 1000 1.05 OVERALL " THICKNESS BR 1250 EX 1250 BR 750 1.30 OVERALL .775 OVERALL " THICKNESS THICKNESS MS 1250 EX 1300 1.30„ OVERALL THICKNESS SELF IGNITION TEMP. ASTM D1929 9147 896'F 896'F 878'F 896'F FLASH IGNITION TEMP. ASTM D1929 7347 806'F 824'F 680'F 698'F SMOKE DENSITY RATING (MAX.) ASTM 2843 69.6% 50.6% 45% 50.6% 45.3% AVERAGE RATE OF BURNING ASTM D635 -- -- -- .405 IN./MIN. 370 IN./MIN. BURNING RATE CLASS ASTM D635 CC1 CC1 CC1 CC2 CC2 MAKROLON HYGARD ® CG 375 3/16” MAKROLON AR -1 POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 3/16" MAKROLON AR -1 POLYCARBONATE SHEET MAKROLON HYGARD ® CG 500 MAKROLON HYGARD ® EX 500 1/8" MAKROLON AR -1 POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/4" MAKROLON POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/8" MAKROLON AR -1 POLYCARBONATE SHEET MAKROLON HYGARD ® CG 750 1/8" MAKROLON AR -1 POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/2" MAKROLON POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/8" MAKROLON AR -1 POLYCARBONATE SHEET MAKROLON HYGARD ® BR 1000 MAKROLON HYGARD ® EX 1000 1 /8" MAKROLON AR -1 POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 3/8" MAKROLON POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 3/8" MAKROLON POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/8" MAKROLON AR -1 POLYCARBONATE SHEET MAKROLON HYGARD ® BR 1250 MAKROLON HYGARD ® EX 1250 1/8" MAKROLON AR -1 POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/2" MAKROLON POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/2" MAKROLON POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/8" MAKROLON AR -1 POLYCARBONATE SHEET MAKROLON HYGARD ® BR 750 1/8" MAKROLON AR -1 POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/2" ACRYLIC SHEET .025" POLYURETHANE INTERLAYER 1/8" MAKROLON AR -1 POLYCARBONATE SHEET MAKROLON HYGARD ® MS 1250 MAKROLON HYGARD ® EX 1300 1/8" MAKROLON AR -1 POLYCARBONATE SHEET .025" POLYURETHANE INTERLAYER 1/2" MAKROLON OP SHEET .025" POLYURETHANE INTERLAYER 1/2" ACRYLIC SHEET .025" POLYURETHANE INTERLAYER 1/8" MAKROLON AR -1 POLYCARBONATE SHEET PRODUCT DESCRIPTION: POLYCARBONATE SHEETS ARE EXTRUDED RESINS WITH PRIMARY USE AS GLAZING AND LIGHT TRANSMITTING SYSTEMS. STANDARD SIZES ARE UPTO 120" LONG CUSTOM SIZES ARE ALSO AVAILABLE. FROM POLYCARBONATE FOR WINDOWS, SKYLIGTHS AND 96" WIDE. MAKROLON POLYCARBONATE MATERIAL COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2010 EDITION INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). MAKROLON GP REPRESENTS THE UNCOATED POLYCARBONATE SHEET AND IS APPROVED FOR USE IN EXTERIOR APPLICATIONS WITHOUT THE UV PROTECTIVE COATING. MAKROLON GP ALSO INCLUDES: OP, GP MATTE, GP PEBBLE, GP PRISMATIC AND GP SATIN. NOTF- THIS IS A COMPONENT APPROVAL AND DOES NOT INCLUDE AN EVALUATION OF STRUCTURAL PERFORMANCE OF THIS COMPONENT. SYSTEMS INCORPORATING THESE COMPONENTS SHALL APPLY FOR A NOA TO THE MIAMI-DADE COUNTY PRODUCT CONTROL DIVISION AND SHALL SUBMIT TEST REPORTS AND OTHER REQUIRED DOCUMENTS SHOWING THAT THE SYSTEM USING THESE COMPONENTS WILL RESIST THE LOADS ACCORDING TO CHAPTER 16 OF THE FBC 2010. i'RC0UCT REVISPD m a onus with dw Fkcids Accepiom Nle j2-064 oS > i�c•bR 17 sY L Mihai Product ConW ngr: JAVAD AHMAD CAVIL FLA. PE # 70592 C: A. N. 3538 O I 0 c� i z opo _z N O c�'o � Hz( " Lu Q 2 N O o a� M � O oU OM pada.°-I Oo 00 O Q W � tf^! �Zv? �o Lo Q wCrli F r` U o i J rn N Fes- LLQ N Lu U M, w z w .. LLJ V)0N u- 0 Qn,o M Ix w >- co � d� v Qm� o too CLr,) J ci- Q w M w (A m = w drawing no. G08-01 sheet 1 of 1