Buchmeyer Residence Load Calcs
2020-Oct-21 11:43:36 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Residence CO2Manual S Compliance Report Job: Buchmeyer Date: Oct 21, 2020Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For: 20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 Cooling Equipment Design Conditions °F75.2Entering coil DB:Btuh27713Sensible gain:°F90.4Outdoor design DB: °F63.2Entering coil WB:Btuh7364Latent gain:°F77.4Outdoor design WB: Btuh35076Total gain:°F75.0Indoor design DB: cfm1200Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: 4TTR6042J1+TEM6A0C42H41++TDRModel:TraneManufacturer: cfm1200Actual airflow: % of load111Btuh30676Sensible capacity: % of load108Btuh7982Latent capacity: %79SHR:% of load110Btuh38658Total capacity: Heating Equipment Design Conditions °F69.7Entering coil DB:Btuh28323Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: BAYHTR1510BRKCModel:TraneManufacturer: cfm1200Actual airflow: °F25Temp. rise:% of load116kW9.6Output capacity: Meets all requirements of ACCA Manual S. 2020-Oct-21 11:43:36 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Building Analysis Date: Oct 21, 2020Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For: 20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 Design Conditions Location:CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5050Relative humidity (%)°N28Latitude: Outdoor:56.924.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) Blower doorMethod)L(15-Daily range (°F) 3 (partial) / 1Shielding / stories77-Wet bulb (°F) 50 Pa / 2323 cfmPressure / AVF7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ducts % of loadBtuhBtuh/ft²Component 26.374413.1Walls 8.824889.1Glazing 2.572017.4Doors 16.346101.6Ceilings 12.936461.31.3Floors 19.856092.1Infiltration 13.43809Ducts 00Piping 00Humidification 00Ventilation0Adjustments 100.028323Total Cooling Walls Glazing Doors Ceilings Infiltration Ducts Internal Gains % of loadBtuhBtuh/ft²Component 24.166862.8Walls 25.5707826.0Glazing 2.672817.6Doors 12.835601.3Ceilings 000Floors 6.016700.6Infiltration 9.22541Ducts 00Ventilation 19.75450Internal gains 00Blower 0Adjustments 100.027713Total Latent Cooling Load = 7364 Btuh Overall U-value = 0.199 Btuh/ft²-°F Data entries checked. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-21 11:43:36 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Residence CO2Load Short Form Job: Buchmeyer Date: Oct 21, 2020Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For: 20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 Design Information InfiltrationClgHtg Blower doorMethod9041Outside db (°F) 3 (partial) / 1Shielding / stories7570Inside db (°F) 50 Pa / 2323 cfmPressure / AVF1529Design TD (°F) L-Daily range 5050Inside humidity (%) 5724Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Trane Make Trane Trade Trane Trade TRANE Model BAYHTR1510BRKC Cond 4TTR6042J1 AHRI ref Coil TEM6A0C42H41++TDR AHRI ref 8628154 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input kW9.6 Sensible cooling Btuh31600 Heating output Btuh32757 Latent cooling Btuh8400 Temperature rise °F25 Total cooling Btuh40000 Actual air flow cfm1200 Actual air flow cfm1200 Air flow factor cfm/Btuh0.042 Air flow factor cfm/Btuh0.043 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.79 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Sitting Room 176 2765 2570 117 111 Master Bedroom 269 1939 1743 82 75 WC 28 489 233 21 10 Master Bath 141 2002 1182 85 51 Master Closet 125 1335 875 57 38 Office 117 222 914 9 40 Entry 72 994 763 42 33 Playroom 162 1370 912 58 39 Bedroom 3 181 2635 1485 112 64 Pantry 18 0 0 0 0 Bath 3 65 124 305 5 13 Laundry 129 1538 1474 65 64 Bedroom 2 172 2578 1722 109 75 Bath 2 55 542 271 23 12 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-21 11:43:36 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 2 ...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Great Room 512 6346 8507 269 368 Bedroom 4 159 1413 931 60 40 Kitchen 340 2031 3826 86 166 Entire House 2720 28323 27713 1200 1200 Other equip loads 0 0 Equip. @ 1.00 RSM 27713 Latent cooling 7364 TOTALS 2720 28323 35076 1200 1200 2020-Oct-21 11:43:36 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Residence CO2Component Constructions Job: Buchmeyer Date: Oct 21, 2020Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For: 20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5050Relative humidity (%)°N28Latitude: Outdoor:56.924.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) Blower doorMethod)L(15-Daily range (°F) 3 (partial) / 1Shielding / stories77-Wet bulb (°F) 50 Pa / 2323 cfmPressure / AVF7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Blk wall, Hardie ext, R-5 int bd ins, 8" thk, 5/8" gyps 5.00.120352ne 10272.9212263.48 14412.9217193.485.00.120494se 9932.9211853.485.00.120341sw 14152.9216893.485.00.120485nw 48772.9258203.485.00.1201672all Knee Wall R-13 2672.672362.3613.00.081100ne 6712.675932.3613.00.081251se 2672.672362.3613.00.081100sw 5642.674992.3613.00.081211nw 17692.6715642.3613.00.081662all 2 x 6 R-19 401.37571.9719.00.06829se Partitions (none) Windows Double Pane, Low-E, Vinyl: Double Pane, Low-E, Vinyl; NFRC rated (SHGC=0.19); 50% blinds 45°, medium; foreground = new concrete (0.32); 10 ft overhang (4 ft window ht, 2.5 ft sep.); 25.3 ft head ht 17817.8908.9900.31010se Double Pane, Low-E, Vinyl: Double Pane, Low-E, Vinyl; NFRC rated (SHGC=0.19); 50% blinds 45°, medium; foreground = new concrete (0.32); 12 ft overhang (5.25 ft window ht, 2.5 ft sep.); 6.8 ft head ht 144117.87288.9900.31081se 41925.91468.9900.31016nw 185919.18738.9900.31097all Double Pane, Low-E, Vinyl: Double Pane, Low-E, Vinyl; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; foreground = green grass (0.23); 2 ft overhang (5.25 ft window ht, 2.5 ft sep.); 6.8 ft head ht 57817.92828.7000.30032sw Double Pane, Low-E, Vinyl: Double Pane, Low-E, Vinyl; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; foreground = new concrete (0.32); 12 ft overhang (5.25 ft window ht, 2.5 ft sep.); 6.8 ft head ht 87026.92828.7000.30032nw 2020-Oct-21 11:43:36 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 2 ...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Double Pane, Low-E, Vinyl: Double Pane, Low-E, Vinyl; NFRC rated (SHGC=0.20); 50% blinds 45°, medium; foreground = new concrete (0.32); 12 ft overhang (6.7 ft window ht, 2.5 ft sep.); 6.8 ft head ht 107526.83859.5700.33040nw 161326.85779.5700.33060nw 268926.89629.5700.330101all Doors Door, mtl fbrgl type 36917.636517.46.30.60021ne 35917.635517.46.30.60020se 72817.672017.46.30.60041all Ceilings Metal Roof, Encapsulated R-19 35601.2746101.6420.00.4052811 Floors Slab on Grade 00364616.900.582216 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-21 11:43:36 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Project Summary Date: Oct 21, 2020Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For:20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 Westerberg Architecture 8196 25th St Vero Beach, FL 32866 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh24514 Structure Btuh25171 Ducts Btuh3809 Ducts Btuh2541Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh28323 Use manufacturer's data y Rate/swing multiplier 1.00InfiltrationEquipment sensible load Btuh27713 Method Latent Cooling Equipment Load SizingBlower door Shielding / stories 3 (partial) / 150 Pa / 2323 cfmPressure / AVF Structure Btuh4813 Ducts Btuh2550Central vent (0 cfm)Btuh0 CoolingHeating (none)27202720Area (ft²)Equipment latent load Btuh7364 2787127871Volume (ft³)Air changes/hour 0.210.38 Equipment Total Load (Sen+Lat)Btuh35076 Equiv. AVF (cfm)99176 Req. total capacity at 0.79 SHR ton2.9 Heating Equipment Summary Cooling Equipment Summary Make Trane Make TraneTrade Trane Trade TRANE Model BAYHTR1510BRKC Cond 4TTR6042J1AHRI ref Coil TEM6A0C42H41++TDR AHRI ref 8628154Efficiency100 EFF Efficiency 13.5 EER, 16 SEER Heating input kW9.6 Sensible cooling Btuh31600Heating output Btuh32757 Latent cooling Btuh8400 Temperature rise °F25 Total cooling Btuh40000Actual air flow cfm1200 Actual air flow cfm1200 Air flow factor cfm/Btuh0.042 Air flow factor cfm/Btuh0.043Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-21 11:43:36Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 21, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Entire House Sitting Room 2 Exposed wall 216.0 ft 27.0 ft 3 Room height 10.2 ft 9.3 heat/coolft 4 Room dimensions ft11.0x16.0 5 Room area 2720.0 ft²176.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 373 352 1226 1027 0 0 0 0 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 21 21 365 369 0 0 0 0 .WW Knee Wall R-13Knee Wall R-13 0.0810.081 nene 2.362.36 2.672.67 100 100 236 267 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 39 29 57 40 0 0 0 0 11 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 10 10 90 178 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 595 494 1719 1441 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 81 81 728 1441 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 20 20 355 359 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 sese 2.362.36 2.672.67 251 251 593 671 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 373 341 1185 993 103 103 357 299 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 32 5 282 578 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 swsw 2.362.36 2.672.67 100 100 236 267 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 634 485 1689 1415 149 109 380 318 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 32 0 282 870 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 16 0 146 419 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 40 0 385 1075 40 0 385 1075 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 60 0 577 1613 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 nwnw 2.362.36 2.672.67 211 211 499 564 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 2811 2811 4610 3560 176 176 289 223 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 2720 216 3646 0 176 27 456 0 6 c) AED excursion 904 262 Envelope loss/gain 18905 18051 1866 2177 12 a) Infiltration 5609 1670 528 157 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 5 1150 0 0 Appliances/other 4300 0 Subtotal (lines 6 to 13)24514 25171 2394 2334 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 24514 25171 2394 2334 15 Duct loads 16%10%3809 2541 16%10%372 236 Total room load 28323 27713 2765 2570 Air required (cfm)Air required (cfm)1200 1200 117 111 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-21 11:43:36Right-Suite® Universal 2019 19.0.21 RSU27939 Page 2...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 21, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Master Bedroom WC 2 Exposed wall 15.5 ft 5.5 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft269.0x1.0 ft5.5x5.0 5 Room area 269.0 ft²27.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 0 0 0 0 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW Knee Wall R-13Knee Wall R-13 0.0810.081 nene 2.362.36 2.672.67 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 11 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 sese 2.362.36 2.672.67 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 145 112 391 327 51 51 178 149 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 32 5 282 578 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 swsw 2.362.36 2.672.67 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 nwnw 2.362.36 2.672.67 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 269 269 441 341 28 28 45 35 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 269 16 262 0 28 6 93 0 6 c) AED excursion 247 -5 Envelope loss/gain 1375 1493 316 179 12 a) Infiltration 303 90 107 32 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1678 1583 423 211 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1678 1583 423 211 15 Duct loads 16%10%261 160 16%10%66 21 Total room load 1939 1743 489 233 Air required (cfm)Air required (cfm)82 75 21 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-21 11:43:36Right-Suite® Universal 2019 19.0.21 RSU27939 Page 3...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 21, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Master Bath Master Closet 2 Exposed wall 20.5 ft 12.5 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft141.3x1.0 ft125.3x1.0 5 Room area 141.3 ft²125.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 0 0 0 0 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW Knee Wall R-13Knee Wall R-13 0.0810.081 nene 2.362.36 2.672.67 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 11 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 117 100 350 293 117 100 350 293 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 16 16 146 288 16 16 146 288 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 sese 2.362.36 2.672.67 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 75 75 260 218 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 swsw 2.362.36 2.672.67 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 nwnw 2.362.36 2.672.67 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 141 141 232 179 125 125 205 159 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 141 21 346 0 125 13 211 0 6 c) AED excursion -23 -17 Envelope loss/gain 1332 954 911 722 12 a) Infiltration 401 119 244 73 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1733 1073 1156 795 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1733 1073 1156 795 15 Duct loads 16%10%269 108 16%10%180 80 Total room load 2002 1182 1335 875 Air required (cfm)Air required (cfm)85 51 57 38 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-21 11:43:36Right-Suite® Universal 2019 19.0.21 RSU27939 Page 4...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 21, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Office Entry 2 Exposed wall 0 ft 6.5 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft13.0x9.0 ft11.0x6.5 5 Room area 117.0 ft²71.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 0 0 0 0 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW Knee Wall R-13Knee Wall R-13 0.0810.081 nene 2.362.36 2.672.67 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 39 29 57 40 11 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 10 10 90 178 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 0 0 0 0 22 1 4 4 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 20 20 355 359 WW Knee Wall R-13Knee Wall R-13 0.0810.081 sese 2.362.36 2.672.67 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 swsw 2.362.36 2.672.67 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 nwnw 2.362.36 2.672.67 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 117 117 192 148 72 72 117 91 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 117 0 0 0 72 7 110 0 6 c) AED excursion -18 -15 Envelope loss/gain 192 130 733 656 12 a) Infiltration 0 0 127 38 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 700 0 Subtotal (lines 6 to 13)192 830 860 693 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 192 830 860 693 15 Duct loads 16%10%30 84 16%10%134 70 Total room load 222 914 994 763 Air required (cfm)Air required (cfm)9 40 42 33 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-21 11:43:36Right-Suite® Universal 2019 19.0.21 RSU27939 Page 5...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 21, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Playroom Bedroom 3 2 Exposed wall 12.0 ft 27.5 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft13.5x12.0 ft181.0x1.0 5 Room area 162.0 ft²181.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 145 145 503 422 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW Knee Wall R-13Knee Wall R-13 0.0810.081 nene 2.362.36 2.672.67 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 11 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 112 96 333 279 112 96 333 279 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 16 16 146 288 16 16 146 288 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 sese 2.362.36 2.672.67 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 swsw 2.362.36 2.672.67 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 nwnw 2.362.36 2.672.67 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 162 162 266 205 181 181 297 229 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 162 12 203 0 181 28 464 0 6 c) AED excursion -18 -29 Envelope loss/gain 947 755 1743 1189 12 a) Infiltration 235 70 537 160 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1182 824 2281 1349 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 5 3 0 0 14 Subtotal 1186 828 2281 1349 15 Duct loads 16%10%184 84 16%10%354 136 Total room load 1370 912 2635 1485 Air required (cfm)Air required (cfm)58 39 112 64 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-21 11:43:36Right-Suite® Universal 2019 19.0.21 RSU27939 Page 6...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 21, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Pantry Bath 3 2 Exposed wall 0 ft 0 ft 3 Room height 10.8 heat/coolft 9.3 heat/coolft 4 Room dimensions ft4.5x4.0 ft65.3x1.0 5 Room area 18.0 ft²65.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 0 0 0 0 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW Knee Wall R-13Knee Wall R-13 0.0810.081 nene 2.362.36 2.672.67 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 11 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 sese 2.362.36 2.672.67 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 swsw 2.362.36 2.672.67 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 nwnw 2.362.36 2.672.67 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 19 19 31 24 65 65 107 83 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 18 0 0 0 65 0 0 0 6 c) AED excursion -1 -6 Envelope loss/gain 31 24 107 77 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 200 Subtotal (lines 6 to 13)31 24 107 277 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -31 -24 0 0 14 Subtotal 0 0 107 277 15 Duct loads 16%10%0 0 16%10%17 28 Total room load 0 0 124 305 Air required (cfm)Air required (cfm)0 0 5 13 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-21 11:43:36Right-Suite® Universal 2019 19.0.21 RSU27939 Page 7...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 21, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Laundry Bedroom 2 2 Exposed wall 12.0 ft 27.0 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft129.3x1.0 ft171.9x1.0 5 Room area 129.3 ft²171.9 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 112 91 317 265 117 117 406 340 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 21 21 365 369 0 0 0 0 .WW Knee Wall R-13Knee Wall R-13 0.0810.081 nene 2.362.36 2.672.67 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 11 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 sese 2.362.36 2.672.67 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 swsw 2.362.36 2.672.67 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 135 119 414 347 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 16 0 146 419 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 nwnw 2.362.36 2.672.67 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 129 129 212 164 172 172 282 218 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 129 12 203 0 172 27 456 0 6 c) AED excursion -29 83 Envelope loss/gain 1096 769 1703 1407 12 a) Infiltration 235 70 528 157 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)1331 1339 2231 1564 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1331 1339 2231 1564 15 Duct loads 16%10%207 135 16%10%347 158 Total room load 1538 1474 2578 1722 Air required (cfm)Air required (cfm)65 64 109 75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-21 11:43:36Right-Suite® Universal 2019 19.0.21 RSU27939 Page 8...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 21, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Bath 2 Great Room 2 Exposed wall 5.5 ft 32.0 ft 3 Room height 9.3 heat/coolft 12.3 heat/coolft 4 Room dimensions ft10.0x5.5 ft511.6x1.0 5 Room area 55.0 ft²511.6 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 0 0 0 0 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW Knee Wall R-13Knee Wall R-13 0.0810.081 nene 2.362.36 2.672.67 0 0 0 0 45 45 105 119 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 11 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 sese 2.362.36 2.672.67 0 0 0 0 247 247 584 660 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 swsw 2.362.36 2.672.67 0 0 0 0 57 57 135 152 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 51 51 179 150 299 206 716 600 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 32 0 282 870 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 60 0 577 1613 WW Knee Wall R-13Knee Wall R-13 0.0810.081 nwnw 2.362.36 2.672.67 0 0 0 0 60 60 142 160 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 55 55 90 70 567 567 930 718 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 55 6 93 0 512 32 540 0 6 c) AED excursion -5 572 Envelope loss/gain 362 214 4011 5466 12 a) Infiltration 107 32 1482 441 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 4 920 Appliances/other 0 900 Subtotal (lines 6 to 13)469 246 5492 7727 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 469 246 5492 7727 15 Duct loads 16%10%73 25 16%10%853 780 Total room load 542 271 6346 8507 Air required (cfm)Air required (cfm)23 12 269 368 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-21 11:43:36Right-Suite® Universal 2019 19.0.21 RSU27939 Page 9...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 21, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Bedroom 4 Kitchen 2 Exposed wall 12.5 ft 0 ft 3 Room height 9.3 heat/coolft 12.1 heat/coolft 4 Room dimensions ft158.8x1.0 ft339.8x1.0 5 Room area 158.8 ft²339.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 0 0 0 0 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW Knee Wall R-13Knee Wall R-13 0.0810.081 nene 2.362.36 2.672.67 0 0 0 0 55 55 131 148 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 11 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 117 100 350 293 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 16 16 146 288 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 sese 2.362.36 2.672.67 0 0 0 0 4 4 9 11 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 swsw 2.362.36 2.672.67 0 0 0 0 43 43 101 115 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 WW Knee Wall R-13Knee Wall R-13 0.0810.081 nwnw 2.362.36 2.672.67 0 0 0 0 151 151 357 404 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 159 159 260 201 374 374 614 474 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 159 13 211 0 340 0 0 0 6 c) AED excursion -18 -75 Envelope loss/gain 966 764 1213 1076 12 a) Infiltration 244 73 531 158 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 1 230 Appliances/other 0 2000 Subtotal (lines 6 to 13)1211 837 1744 3464 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 12 9 15 11 14 Subtotal 1223 846 1758 3475 15 Duct loads 16%10%190 85 16%10%273 351 Total room load 1413 931 2031 3826 Air required (cfm)Air required (cfm)60 40 86 166 2020-Oct-21 11:43:04 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Residence CO2Static Pressure and Friction Rate Job: Buchmeyer Date: Oct 21, 2020Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For: 20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 Available Static Pressure CoolingHeating (in H2O)(in H2O) 0.700.70External static pressure Pressure losses 00Coil 0.040.04Heat exchanger 0.030.03Supply diffusers 0.030.03Return grilles 0.250.25Filter 00Humidifier 0.030.03Balancing damper 00Other device 0.320.32Available static pressure Total Effective Length ReturnSupply (ft)(ft) 1122Measured length of run-out 5048Measured length of trunk 180195Equivalent length of fittings 241266Total length 506Total effective length Friction Rate CoolingHeating (in/100ft)(in/100ft) OK0.063OK0.063Supply Ducts OK0.063OK0.063Return Ducts Fitting Equivalent Length Details 4X=35, 2A0=35, 11G=5, 11G=5, 11I=10, 11A=20, 11G=5, 11G=5, 11A=20, 11G=5, 11G=5, 1A=35, USR1=10: TotalEL=195 Supply 11A=20, 6M=20, 11G=5, 10G=75, 8E=10, 11G=5, 11G=5, 5A=40: TotalEL=180Return 2020-Oct-21 11:43:04 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Residence CO2Duct System Summary Job: Buchmeyer Date: Oct 21, 2020Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For: 20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.38in H2O0.38 Available static pressure in H2O0.32in H2O0.32 Supply / return available pressure 0.168 / 0.152 in H2O in H2O0.168 / 0.152 Lowest friction rate in/100ft0.063in/100ft0.063 Actual air flow cfm1200cfm1200 Total effective length (TEL)ft506 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st3140.020.2VlFx0x04.00.105120271cBath 2 st2105.016.6VlFx0x04.00.138130305cBath 3 75.06.0VlFx0x06.00.2077501722cBedroom 2 st2105.017.4VlFx0x06.00.1376401485cBedroom 3 st5135.034.5VlFx0x05.00.099400931cBedroom 4 st5135.045.0VlFx0x05.00.093330763cEntry st4115.041.9VlFx0x07.00.1079202127cGreat Room st4115.039.9VlFx0x07.00.1089202127cGreat Room-A st3130.026.8VlFx0x07.00.1079202127cGreat Room-B st3120.023.0VlFx0x07.00.1179202127cGreat Room-C st5135.041.3VlFx0x07.00.0958301913cKitchen st5135.029.7VlFx0x07.00.1028301913cKitchen-A st2105.015.1VlFx0x06.00.1406401474cLaundry st7190.063.8VlFx0x06.00.0665101182cMaster Bath st4115.053.2VlFx0x07.00.1007501743cMaster Bedroom st7200.052.1VlFx0x05.00.067380875cMaster Closet st7210.051.3VlFx0x06.00.064400914cOffice-A st2105.021.5VlFx0x05.00.133390912cPlayroom st4125.059.2VlFx0x08.00.09111102570cSitting Room st7195.070.6VlFx0x04.00.063100233cWC 2020-Oct-21 11:43:04 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 2 ...ns 10-21-2020\Buchmeyer Residence CO2 Final.rup Calc = MJ8 Front Door faces: SE Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st7 Peak AVF 0 139 0.063 397 8.0 0x0 RectFbg st6 st3 Peak AVF 0 567 0.091 530 14.0 0x0 RectFbg st1 st4 Peak AVF 0 371 0.091 472 12.0 0x0 VinlFlx st3 st1 Peak AVF 0 567 0.091 530 14.0 0x0 VinlFlx st5 Peak AVF 0 378 0.063 353 14.0 0x0 VinlFlx st2 st6 Peak AVF 0 139 0.063 314 9.0 0x0 VinlFlx st5 st2 Peak AVF 0 559 0.063 523 14.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb5 0x 00 75 185.4 0.082 279 7.0 x0 0 VlFx rt2 rb6 0x 00 395 183.2 0.083 503 12.0 x0 0 VlFx rt2 rb1 0x 00 175 240.8 0.063 320 10.0 x0 0 VlFx rt4 rb8 0x 00 40 240.6 0.063 202 6.0 x0 0 VlFx rt4 rb2 0x 00 111 235.4 0.065 319 8.0 x0 0 VlFx rt4 rb7 0x 00 300 234.8 0.065 382 12.0 x0 0 VlFx rt4 rb3 0x 00 40 230.1 0.066 205 6.0 x0 0 VlFx rt3 rb4 0x 00 64 226.7 0.067 241 7.0 x0 0 VlFx rt3 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt2 Peak AVF 0 574 0.066 537 14.0 0x0 VinlFlx rrs1 rrs1 Peak AVF 0 1200 0.063 576 17.0 15x20 RectFbg rt1 rt4 Peak AVF 0 626 0.063 448 16.0 0x0 VinlFlx rrs1 rt3 Peak AVF 0 105 0.066 300 8.0 0x0 VinlFlx rt2 rt1 Peak AVF 0 1200 0.063 533 16.1 18x18 RectFbg