Loading...
HomeMy WebLinkAboutMontoya - Energy - RevisedEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 510/15/2020 9:13 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County Dansar Homes Montoya Residence Montoya Residence Street: City, State, Zip: Fort Pierce , FL , 34981 2802 Grove Street Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 1614 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.65 125.80 ft² SHGC=0.25 N/A f t ² N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1614.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1447.50 ft² b. Frame - Wood, Adjacent R=19.0 177.33 ft² c. Frame - Wood, Adjacent R=11.0 121.33 ft² 10. Ceiling Types a. Under Attic (Vented)R=30.0 1614.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 1 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:1.000 ft. Area Weighted Average SHGC:0.250 Description Area Insulation Area Insulation Area Insulation Area 15. Credits CF, Pstat 3 (125.8 sqft.) (1746.2 sqft.) (1614.0 sqft.) (1614.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 30.0 SEER:15.75 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 105 Tankless EF: 0.950 Glass/Floor Area: 0.078 Total Proposed Modified Loads: Total Baseline Loads: 54.28 56.51 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 10-16-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County Dansar Homes 1 Montoya Residence Montoya Residence Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 1614 3 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34981 Fort Pierce , St. Lucie 2802 Grove Street Street Address Comment: Building Type: User Cross Ventilation: No Whole House Fan: No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 1614 15475.6 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 Bedroom 3 245 2303 No 1 1 Yes Yes1 Yes 2 Bath 2 66 620.4 No 0 Yes Yes1 Yes 3 Bedroom 2 201 1889.4 No 1 1 Yes Yes1 Yes 4 Kitchen 224 2105.6 Yes 2 Yes Yes1 Yes 5 Dining 64 601.6 No 0 Yes Yes1 Yes 6 Master Bedroom 304 3161.6 No 2 1 Yes Yes1 Yes 7 Master Bath 84 789.6 No 0 Yes Yes1 Yes 8 Laundry 49 460.6 No 0 Yes Yes1 No 9 Great Room 340 3196 No 2 Yes Yes1 Yes 10 Hall 37 347.8 No 0 Yes Yes1 No # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 245 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -33 ft Bedroom 3 2 66 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft Bath 2 3 201 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -34 ft Bedroom 2 4 224 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -10 ft Kitchen 5 64 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -8 ft Dining 6 304 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -35 ft Master Bedroom 7 84 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -7 ft Master Bath 10/15/2020 9:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 8 49 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Laundry 9 340 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -17 ft Great Room 10 37 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Composition shingles 1748 ft² Medium 0.6 0 22.6______ No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 1614 ft² N N150 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented) 30 245 ft² 0.1 Wood______ Bedroom 3 Batt 2 Under Attic (Vented) 30 66 ft² 0.1 Wood______ Bath 2 Batt 3 Under Attic (Vented) 30 201 ft² 0.1 Wood______ Bedroom 2 Batt 4 Under Attic (Vented) 30 224 ft² 0.1 Wood______ Kitchen Batt 5 Under Attic (Vented) 30 64 ft² 0.1 Wood______ Dining Batt 6 Under Attic (Vented) 30 304 ft² 0.1 Wood______ Master Bedroom Batt 7 Under Attic (Vented) 30 84 ft² 0.1 Wood______ Master Bath Batt 8 Under Attic (Vented) 30 49 ft² 0.1 Wood______ Laundry Batt 9 Under Attic (Vented) 30 340 ft² 0.1 Wood______ Great Room Batt 10 Under Attic (Vented) 30 37 ft² 0.1 Wood______ Hall Batt WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0Bedroom 3 05013 9N Concrete Block - Int Insul 0.40Exterior 122.4 ft² ____ 2 4.1 0Bedroom 3 05020 9W Concrete Block - Int Insul 0.40Exterior 188.3 ft² ____ 3 4.1 0Bath 2 0506 9W Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____ 4 4.1 0Bedroom 2 0505 9E Concrete Block - Int Insul 0.40Exterior 47.1 ft² ____ 5 4.1 0Bedroom 2 05014 9S Concrete Block - Int Insul 0.40Exterior 131.8 ft² ____ 6 4.1 0Bedroom 2 05015 9W Concrete Block - Int Insul 0.40Exterior 141.3 ft² ____ 7 4.1 0Kitchen 05010 9N Concrete Block - Int Insul 0.40Exterior 94.2 ft² ____ 8 4.1 0Dining 0508 9N Concrete Block - Int Insul 0.40Exterior 75.3 ft² ____ 9 4.1 0Master Bedro 05019 10N Concrete Block - Int Insul 0.40Exterior 197.9 ft² ____ 10 4.1 0Master Bedro 05016 10E Concrete Block - Int Insul 0.40Exterior 166.7 ft² ____ 11 4.1 0Master Bath 0507 9E Concrete Block - Int Insul 0.40Exterior 65.9 ft² ____ 12 4.1 0Great Room 05017 9S Concrete Block - Int Insul 0.40Exterior 160.1 ft² ____ 10/15/2020 9:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 13 19 0Master Bath 412 9N Frame - Wood 0.40.23Garage 112.0 ft² ____ 14 19 0Laundry 47 9N Frame - Wood 0.40.23Garage 65.3 ft² ____ 15 11 0Great Room 413 9W Frame - Wood 0.40.23Garage 121.3 ft² ____ # Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Wood .39 20.5 ft² None______ S Great Room 1063 2 Wood .46 17.8 ft² None______ S Great Room 8682 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 N Low-E Single 0.65 0.25 15.0 ft² 1 ft 0 in 0 ft 5 in NoneMetal None______ Yes1 N 2 S Low-E Single 0.65 0.25 20.0 ft² 1 ft 0 in 0 ft 5 in NoneMetal None______ Yes5 N 3 N Low-E Single 0.65 0.25 40.8 ft² 1 ft 0 in 0 ft 5 in NoneMetal None______ Yes7 N 4 N Low-E Single 0.65 0.25 15.0 ft² 1 ft 0 in 0 ft 5 in NoneMetal None______ Yes9 N 5 E Low-E Single 0.65 0.25 15.0 ft² 1 ft 0 in 0 ft 5 in NoneMetal None______ Yes11 N 6 S Low-E Single 0.65 0.25 20.0 ft² 1 ft 0 in 0 ft 5 in NoneMetal None______ Yes12 N # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 399 ft² 399 ft² 32 ft 9.4 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1547.6 684.96.000366Wholehouse .1362159.78Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtype BlockSpeed 1 Electric Strip Heat/ COP:1 27 kBtu/hr ______ sys#1None 1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtype BlockSubtype 1 Central Unit/ SEER: 15.75 30 kBtu/hr 900 cfm 0.7______ sys#1Split 1 Singl 10/15/2020 9:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.95 1 gal 60.9 gal 120 deg None______ Tankless Garage FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert # Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply ---- ---- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 105 ft² Attic 35 ft² Default Leakage Garage ( D e f a u l t ) ______ 1 1 ( D e f a u l t ) TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078 Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Bedroom 3 Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 2 Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 2 Default(8 lbs/sq.ft. f t ² f t 0.3 Kitchen Default(8 lbs/sq.ft. f t ² f t 0.3 Dining Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bedroom Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bath Default(8 lbs/sq.ft. f t ² f t 0.3 Laundry Default(8 lbs/sq.ft. f t ² f t 0.3 Great Room Default(8 lbs/sq.ft. f t ² f t 0.3 Hall 10/15/2020 9:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT