HomeMy WebLinkAboutMontoya - Energy - RevisedEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 510/15/2020 9:13 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie County
Dansar Homes
Montoya Residence
Montoya Residence
Street:
City, State, Zip: Fort Pierce , FL , 34981
2802 Grove Street
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
1614
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.65 125.80 ft²
SHGC=0.25
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1614.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1447.50 ft²
b. Frame - Wood, Adjacent R=19.0 177.33 ft²
c. Frame - Wood, Adjacent R=11.0 121.33 ft²
10. Ceiling Types
a. Under Attic (Vented)R=30.0 1614.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 1 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:1.000 ft.
Area Weighted Average SHGC:0.250
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits CF, Pstat
3
(125.8 sqft.)
(1746.2 sqft.)
(1614.0 sqft.)
(1614.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
30.0 SEER:15.75
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 105
Tankless
EF: 0.950
Glass/Floor Area: 0.078
Total Proposed Modified Loads:
Total Baseline Loads:
54.28
56.51 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
10-16-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie County
Dansar Homes
1
Montoya Residence
Montoya Residence
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
1
1614
3
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL , 34981
Fort Pierce ,
St. Lucie
2802 Grove Street
Street Address
Comment:
Building Type: User
Cross Ventilation: No
Whole House Fan: No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 1614 15475.6
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 Bedroom 3 245 2303 No 1 1 Yes Yes1 Yes
2 Bath 2 66 620.4 No 0 Yes Yes1 Yes
3 Bedroom 2 201 1889.4 No 1 1 Yes Yes1 Yes
4 Kitchen 224 2105.6 Yes 2 Yes Yes1 Yes
5 Dining 64 601.6 No 0 Yes Yes1 Yes
6 Master Bedroom 304 3161.6 No 2 1 Yes Yes1 Yes
7 Master Bath 84 789.6 No 0 Yes Yes1 Yes
8 Laundry 49 460.6 No 0 Yes Yes1 No
9 Great Room 340 3196 No 2 Yes Yes1 Yes
10 Hall 37 347.8 No 0 Yes Yes1 No
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 245 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -33 ft Bedroom 3
2 66 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft Bath 2
3 201 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -34 ft Bedroom 2
4 224 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -10 ft Kitchen
5 64 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -8 ft Dining
6 304 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -35 ft Master Bedroom
7 84 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -7 ft Master Bath
10/15/2020 9:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
8 49 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Laundry
9 340 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -17 ft Great Room
10 37 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Composition shingles 1748 ft² Medium 0.6 0 22.6______ No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 1614 ft² N N150
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented) 30 245 ft² 0.1 Wood______ Bedroom 3 Batt
2 Under Attic (Vented) 30 66 ft² 0.1 Wood______ Bath 2 Batt
3 Under Attic (Vented) 30 201 ft² 0.1 Wood______ Bedroom 2 Batt
4 Under Attic (Vented) 30 224 ft² 0.1 Wood______ Kitchen Batt
5 Under Attic (Vented) 30 64 ft² 0.1 Wood______ Dining Batt
6 Under Attic (Vented) 30 304 ft² 0.1 Wood______ Master Bedroom Batt
7 Under Attic (Vented) 30 84 ft² 0.1 Wood______ Master Bath Batt
8 Under Attic (Vented) 30 49 ft² 0.1 Wood______ Laundry Batt
9 Under Attic (Vented) 30 340 ft² 0.1 Wood______ Great Room Batt
10 Under Attic (Vented) 30 37 ft² 0.1 Wood______ Hall Batt
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0Bedroom 3 05013 9N Concrete Block - Int Insul 0.40Exterior 122.4 ft² ____
2 4.1 0Bedroom 3 05020 9W Concrete Block - Int Insul 0.40Exterior 188.3 ft² ____
3 4.1 0Bath 2 0506 9W Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____
4 4.1 0Bedroom 2 0505 9E Concrete Block - Int Insul 0.40Exterior 47.1 ft² ____
5 4.1 0Bedroom 2 05014 9S Concrete Block - Int Insul 0.40Exterior 131.8 ft² ____
6 4.1 0Bedroom 2 05015 9W Concrete Block - Int Insul 0.40Exterior 141.3 ft² ____
7 4.1 0Kitchen 05010 9N Concrete Block - Int Insul 0.40Exterior 94.2 ft² ____
8 4.1 0Dining 0508 9N Concrete Block - Int Insul 0.40Exterior 75.3 ft² ____
9 4.1 0Master Bedro 05019 10N Concrete Block - Int Insul 0.40Exterior 197.9 ft² ____
10 4.1 0Master Bedro 05016 10E Concrete Block - Int Insul 0.40Exterior 166.7 ft² ____
11 4.1 0Master Bath 0507 9E Concrete Block - Int Insul 0.40Exterior 65.9 ft² ____
12 4.1 0Great Room 05017 9S Concrete Block - Int Insul 0.40Exterior 160.1 ft² ____
10/15/2020 9:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
13 19 0Master Bath 412 9N Frame - Wood 0.40.23Garage 112.0 ft² ____
14 19 0Laundry 47 9N Frame - Wood 0.40.23Garage 65.3 ft² ____
15 11 0Great Room 413 9W Frame - Wood 0.40.23Garage 121.3 ft² ____
# Door Type U-Value AreaStorms
DOORS
Ornt Space
Width
Ft In Ft In
Height
1 Wood .39 20.5 ft² None______ S Great Room 1063
2 Wood .46 17.8 ft² None______ S Great Room 8682
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 N Low-E Single 0.65 0.25 15.0 ft² 1 ft 0 in 0 ft 5 in NoneMetal None______ Yes1 N
2 S Low-E Single 0.65 0.25 20.0 ft² 1 ft 0 in 0 ft 5 in NoneMetal None______ Yes5 N
3 N Low-E Single 0.65 0.25 40.8 ft² 1 ft 0 in 0 ft 5 in NoneMetal None______ Yes7 N
4 N Low-E Single 0.65 0.25 15.0 ft² 1 ft 0 in 0 ft 5 in NoneMetal None______ Yes9 N
5 E Low-E Single 0.65 0.25 15.0 ft² 1 ft 0 in 0 ft 5 in NoneMetal None______ Yes11 N
6 S Low-E Single 0.65 0.25 20.0 ft² 1 ft 0 in 0 ft 5 in NoneMetal None______ Yes12 N
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 399 ft² 399 ft² 32 ft 9.4 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1547.6 684.96.000366Wholehouse .1362159.78Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Strip Heat/ COP:1 27 kBtu/hr ______ sys#1None 1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/ SEER: 15.75 30 kBtu/hr 900 cfm 0.7______ sys#1Split 1 Singl
10/15/2020 9:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.95 1 gal 60.9 gal 120 deg None______ Tankless Garage
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 105 ft² Attic 35 ft² Default Leakage Garage ( D e f a u l t ) ______ 1 1 ( D e f a u l t )
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878
Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Bedroom 3
Default(8 lbs/sq.ft. f t ² f t 0.3 Bath 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Kitchen
Default(8 lbs/sq.ft. f t ² f t 0.3 Dining
Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bedroom
Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bath
Default(8 lbs/sq.ft. f t ² f t 0.3 Laundry
Default(8 lbs/sq.ft. f t ² f t 0.3 Great Room
Default(8 lbs/sq.ft. f t ² f t 0.3 Hall
10/15/2020 9:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT