HomeMy WebLinkAboutSIGN LTR HELIC ESSI AUTIN RES 7100 LORRAINE CT PSL CEGNutting E Engineers of Florida Inc. I Established 1967 Your Project is Our Commitment October 26, 2020 Mr. Scott Synakowski Eastern Structural Services, Inc. 4851 SE 128`h Avenue Geotechnical & Construction Materials Engineering, Testing, & Inspection Environmental Services Offices throughout the state of Florida www.nuttingengineers.com info@nuttingengineers.com Okeechobee, Florida 34975 Phone: 772.349.5507 Email: estructuralservices.com Subject: Report of Helical Pier Installation Monitoring Proposed Autin Residence Repairs 7100 Lorraine Court Port St. Lucie, Florida Dear Mr. Synakowski: Nutting Engineers of Florida, Inc. (NE) has completed the observation of the helical pier installation operations at the above referenced site in Port St. Lucie, Florida. Eastern Structural Services, Inc. (ESSI) installed 15 piers on October 20, 2020. We note that pier 11 was not installed due to access issues and utilities around the existing A/C unit. The piers size and depth anticipation were based upon our review of prior boring log information by AMEC dated January 11, 2013 performed in the area and the structural engineer recommendations. The installation characteristics of each pier are presented in the attached Helical Pier Installation Data. Identification of each pier location followed by the pier number are shown on the Helical Pier Location Plans attached. Each pier record in the attached summary tables shows the following information: ■ RECORD NUMBER IN CHRONOLOGICAL ORDER ■ THE HELICAL PIER NUMBER (AS FOUND ON ATTACHED PLANS) ■ LENGTH OF PIER FROM GROUND SURFACE TO TIP ■ THE INSTALLATION TIME ■ THE DATE OF INSTALLATION ■ THE HELICAL PIER TYPES ■ AND GENERAL COMMENTS AS NEEDED The piers were designed for an allowable compressive capacity of 10 tons as indicated on the structural plans. The helical piers were installed to depths of twenty-seven to forty feet below the existing ground surface where torque conditions or refusal on the hard limestone formation. The drilling operations were monitored in the field by our field inspector in order to approximately evaluate the type of material being penetrated. 1310 Neptune Drive • Boynton Beach, Florida 33426 • (561) 736-4900 • Fax (561) 737-9975 Broward (954) 941-8700 • Port St. Lucie (772) 408-1050 • Miami Dade (305) 624-0060 The piers achieved their design capacity based on a predetermined hydraulic pressure amount indicated on a ft-lbs guage observed in the field during installation or refusal on the limestone formation, whichever occurred first. The piers consisted of a lead seven, which was a 2-7/8-inch round shaft with one 10-inch helix at the tip, one 12-inch helix at thirty inches from the tip, and one 14-inch helix at sixty inches from the tip. The helices were attached at the first shaft and additional five or seven foot, 2-7/8-inch diameter round shafts with no helixes were added to the pier until capacity was achieved. Upon completion of this inspection process, and review of the recorded data, it is our opinion that the helical piers installed at this time attained the required design compressive capacity of 10 tons for the proposed construction. The piers were also constructed in compliance with the plans and specifications. We note that it was monitored and ensured that the piers began installation at the survey locations provided in the field. If during drilling operations it was discovered that gross deviations from original locations have occurred, the deviation was attempted to be rectified. Nutting Engineers is not responsible for minor deviations, which have occurred during installation operations, along with incorrect surveyed pier locations during pier installation. This condition is beyond the control of the site inspector and undersigned engineer. Our client for this geotechnical evaluation was: Mr. Scott Synakowski Eastern Structural Services, Inc. 4851 SE 128th Avenue Okeechobee, Florida 34975 NE shall bear no liability for the implementation of recommended inspection and testing services as described in this report if implemented by others. NE has no ability to verify the completeness, accuracy or proper technique of such procedures if performed by others. The Geotechnical Engineer warrants that the findings, recommendations, specifications, or professional advice contained herein, have been presented after being prepared in accordance with general accepted professional practice in the field of foundation engineering, soil mechanics and engineering geology. No other warranties are implied or expressed. We appreciate the opportunity to provide these services for you. If you should have any questions, or if we can be of any further assistance in this matter, please feel free to contact us. Respectfully Submitted, NUTTING ENGINEERS OF FLORIDA, INC. Christopher E. Gworek, P.E. #69947 Senior Geotechnical Engineer Attachments: Pier Location Plan Pier Installation Records LTR RELIC ESSI AUTIN RES 7100 LORRAINE CT PSL CEG Nutting E Engineers of Florida Inc. I Established 1967 Your Project is Our Commitment This item has been digitally signed and sealed by Christopher E. Gworek on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. o G99 � e STATE OF 4LI o��`' FCORIOP:''G�'���`� 2020-10-26 2 Z - P � ®� a °CTC2�2 C1 AY Ryo i�On�>��o -i Or- Z�mm® mDNmma-m� zOm9z�z4 OOmn,�Dz_r-mmD�i1m�Drmo �-OZm, 1 mrtDzom9l mz-A��-�Oi(�ID°Zu<�AqnDT~-ZCO�2rmm�VNZT�OTrm A{TOmm TDOmocNtiCcnrNzZCzmzc= rDs'0`z�' DNm'p�°D rD�Apt-cil1 N jpprU LOmDZmA .7D7 �Cy .10 0 0, Z O: p 0 D xmD�N171 G Z iahT y ce O m�vox zDO�mmzma <n z O T C Cl pm -{3omm ON_v Or O1z Rt O Z.� z ac:•ran: n�� 5 n=f A y-°-nv> m CTCGzizOOz�'1TO DA ��}7 A N m m Z D m my�D n zoonz=v�o Ty Z -i c9 r z Nod j m Domonmy� m > N o C A D :�a,:a., d m AODz °9xO��mNn, �� N _ ..I 941 mzOo 3!�LAOmo o r0 rpmN _ _ _ mix o a tiNzzo 3 D o Z O aim m� A v S y GI A W NT O n - m m 1= m D D Z { j j r N 0 �m m �QN mx n �� 0 o C TO O 2 D N r m Z 2 C? C v 1„ mz Zm TO z 2 m N w v U) W W N T m O W p W E u °aN r 3 Zz ! II 0 G) D o� m a 1 m 5 oh m G O N mA �i I� TO 0Z O m a z a O � m V � D s ao{c m Ff 1 -ri Z C ;a W Uf V ca 0 N p A O p O = Z O y mm IJ � __ o7 7 7 T°AT y I A? r C — _ n n 'p n cn Q A Z TO W c D / o o N FOUNDATION UNDERPINNING 7100 LORRAINE CT PORT ST LUCIE, FL 34952 PERMIT PLAN DgE,,ao3a DESIDNO.2 DD PROJECTND.303DL01 HOmZ.ScgLE:1"=10' poT.,Dq E wq cirll]D.Ewg -- ftEVI51DN5: HELICAL PIER INSTALLATION RECORDS Client: Eastern Structural Services, Inc. Date(s): 10/20/2020 Project: Autin Res Repairs, 7100 Larraine Ct., PSL Weather: Sunny Contractor: Eastern Structural Services, Inc. Required Capacity: 10 Tons NEF Inspector: Juan Duran Pier Brand: Ideal Manufacturing Record No. Pier No. Final Depth* (ft) Final Torque (ft- Ibs) Equivalent Allowable Capacity (tons) Shaft Lengths (ft)& Number Used Notes 1 16 28 4,800 10 1-7', 5-5' 2 15 27 5,500 10 1-7', 4-5' 3 14 29 5,100 10 1-7', 5-5' 4 12 38 4,000 10 4-7', 2-5' 5 13 35 4,400 10 4-7', 2-5' 6 10 32 4,100 10 5-7' 7 9 40 4,000 10 5-7', 1-5' 8 8 30 4,000 10 5-7' 9 7 30 4,700 10 5-7' 10 6 31 4,200 10 4-7', 1-5' 11 5 36 4,400 10 4-7', 2-5' 12 4 28 4,200 10 3-7', 2-5' 13 3 29 4,000 10 1-7', 5-5' 14 2 28 4,000 10 4-7' 15 1 28 4,000 10 4-7' Helic Shaft Size : 2-7/8" Average Install Time Per Pier: 20 minutes Helicies Size and Location From Tip: 10" @ tip, 12" @ 30" from tip, 14" @ 60" from tip - 7' Onsite Torque/Pressure Value to Tonnage Conversion: 10 ton--4,000 ft-Ibs or Spin Out (S.O.) on Rock Add. Notes: All depths based on adjacent site grades. S/O = Spin out. Pier #11 Not installed (A/C) ESSI AUTIN RES REPAIRS 7100 LORRAINE CT PSL CEG Nutting L Engineers of Florida Inc. 1 Established 1967 Your Project is Our Commitment