Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Watts Gen Specs
20/22 kW INCLUDES: • True Power" Electrical Technology r Two-line multilingual digital LCD Evolution'" controller (English/Spanish/French/Portuguese) • 200 amp service rated smart switch transfer switch available Electronic governor s Standard Wi-Fi® connectivity to System status & maintenance interval LED indicators • Sound attenuated enclosure a Flexible fuel line connector • Natural gas or LP gas operation • 5 Year limited warranty s Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in (457 mm) to a structure.` 'Mustbe located away from doors, windows, and fresh air intakes and in accordance with local codes. haps: //assets.swri. org/library/DirectolyOfListedProducts/ Constructionlndustryl973_DoC_204_13204-01-01 _Rev9. pdf FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- erac's success in providing the most reliable generators possible. Generac's G - Force engine lineup offers added peace of mind and reliability for when it's needed the most. The G -Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER— ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: ✓ PROTOTYPE TESTED ✓ NEMA MG11-22 EVALUATION ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY O MOBILE LINK® CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. GENERA,C® GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating G007038-1, G007039-1, G007038-3, G007039-3 (Aluminum - Bisque) - 20 kW 60 Hz G007042-2, G007043-2, G007042-3, G007043-3 (Aluminum - Bisque) - 22 kW 60 Hz ONor C DS /I`]C �,/ Mobilecus LISTED u k Note: CETLor CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are ETL or UL certified in the USA only. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac mod- els. It provides optimized FAST RESPONSE to changing load conditions and MAXI- MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the small- est electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. W G E N E R A C .�� fit � PROMISE 1a 1 GENERAL® 20/22 kW Features and Benefits Engine • Generac G -Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows fora smaller, lightweight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple, low-cost installation. Evolution" Controls • AUTO/MANUAUOFF illuminated buttons • Two-line multilingual LCD display • Sealed, raised buttons • Utility voltage sensing • Generator voltage sensing • Utility interrupt delay • Engine warm-up • Engine cool -down • Prcgrammable exercise • Smart battery charger • Main line circuit breaker • Electronic governor Unit • SAE weather protective enclosure • Enclosed critical grade muffler • Small, compact, attractive Selects the operating mode and provides easy, at -a -glance status indication in any condition. Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. Smooth, weather -resistant user interface for programming and operations. Constantly monitors utility voltage, setpoints 65% dropout, 80°% pick-up, of standard voltage. Constantly monitors generator voltage to verify the cleanest power delivered to the home. Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Verifies engine is ready to assume the load, setpoint approximately 5 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. Protects generator from overload. Maintains constant 60 Hz frequency. Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure. GENERAC® 20/22 kW Features and Benefits Installation System • 14 in (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity (Wi-Ff equipped models only) • Ability to view generator status Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENER C" 20/22 kW Specifications Generator Model G007038-1, G007039-1 G007042 -2,G007043-2 G00703M,G007039-3 G007042 -3,G007043-3 Rated maximum continuous power rapacity (LP) (20 kW) (22 kW) (20 kW) (22 kW) 20,000 Watts" 22,000 Watts* 20,000 Watts* 22,000 Watts* Rated maximum continuous power capacity (NG) Rated voltage 18,000 Watts* 19,500 Watts' 18,000 Watts* 19,500 Watts Rated maximum continuous load current- 240 volts (LP/NG) 240 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 Total Harmonic Distortion Less than 5% Main line circuit breaker Phase 90 amp 100 amp 90 amp 100 amp Number of rotor poles P Rated AC frequency 60 Hz Power factor 1.0 Battery requirement (not included) 12 Volts, Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight (lb / kg) Dimensions (L x W x H) in / cm 448/203 466/211 436/198 445/202 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load** 48 x 25 x 29 /121,9 x 63.5 x 73.7 67 67 Sound output in dB(A) at 23 ft (7 m) with generator in Quiet -Test' low -speed exercise mode** 67 67 55 57 55 Exercise duration 57 5 min Engine Engine type Numberof cylinders GENERAL G -Farce 1000 Series , Displacement 999 cc won Cylinder block Valve arrangement Aluminum w/ cast iron sleeve Ignition system Overhead valve Governor system Solid-state magneto Compression ratio ro Electronic Starter 9.5D1 Oil rapacity including filter 12 VDC Approx. qt/ 18 L Operating rpm 3,600 Fuel consumption Natural gas ft3/hr (m3/hr) 1/2 Load 204 (5.78) 228 (6 46) 164 (4.64)203 (5.75) L Full Load Liquid propane 10/hr (gal/ho [Uhr] 301 (8.52) 327 (9.26) 287 (8.13) 306 (8.66) 1/2 Load 67 (2.37) [8.99] 92 (2.53) [9.57] 86 (2.36) [8.95] 92 (2 53) [9.57] Full Load 130 (3.56) [13.48] 142 (3.90) [14 771 136 (3.74) [14.15] 142 (3.90) [14.77] Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7 in water column (0.87-1.74 kPa) for NG, 10-12 in crater column (2.49-2.99 kPa) for LP gas. For BTU content, multiply fta/hrx 2500 (LP) or 113/hr x 1000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons: AUTO Automatic start on utility failure. Weekly, Bi -weekly, or Monthly selectable exerciser. MANUAL Start with starter control, unit stays on. If utility fails, transfer to load takes place. OFF Ready to Run/Maintenance messages Stops unit. Power is removed. Control and charger still operate Engine run hours indication Standard Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable (brownout setting) From 140-171 V / 190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/AIamVMaintenance togs 50 events each Engine start sequence Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). Starter lock -out Smart Battery Charger Starter cannot re-engage until 5 sec after engine has stopped. Charger Fault/Missing AC warning Standard Standard _ Low Battery/Battery Problem Protection and Battery Condition indication_ Standard _ Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection _ Standard Automatic Law Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Faoltnncorrect Widng protection Standard Common external fault capability Standard Field upgradable firmware Standard **Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). * Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megaieule content, ambient temperature, altitude, engine level; and also will decrease approximately 1% for each 10 °F (6 °C) above 60 °F (16 °C). power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 ft (304.8 m) above sea 20/22 kW Service Rated Smart Switch Features • Includes digital power management technology (DPM) standard. • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load, 100% equipment rated, both inductive and resistive. • 2 -pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Dimensions 200 Amps 120/240, 1a Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 26.75 30.1 L26.67 0.5 13.5 6.91 cm 67.95 76.45 34.29 17.55 Wire Ranges Conductor Lug I Neutral Lug Ground Lug 400MCM-#4 350MCM-#6 1 2/0-#14 GEN FRAC® Switch Options G007039-1 (20 kW) Model G007043-2 (22 kW) G007039-3 (20 kW) G007043-3 (22 kW) No. of poles Current rating (amps) 200 Voltage rating (VAC) 120/240,10 Utility voltage monitor (fixed)* -Pick-up 80% -Dropout 65% Return to utility* Approx.13 sec Exercises bi-weekly for 5 minutes` Standard ETL or UL listed Standard Enclosure type NEMA/UL 3R Circuit breaker protected 22,000 Lug range 250 MCM - #6 *Function of Evolution controller Exercise can be set to weekly or monthly 20/22 kW Available Accessories Model # Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). G007101-0 Battery Pad Warmer Pad warmer rests under the battery. Recommended for use if temperature regularly falls below 0 IF (-18 °C). (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil fitter. Recommended for use if temperature regularly falls below 0 IF (-18 °C). ' G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not Contact Kit be needed. Not compatible with 50 amp pre -wired switches. G007027-0 - Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators. This offers a sleek, con - (Standard on 22 kW) toured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0 - Bisque Touch -Up Paint Kit If the generator enclosure is scratched or damaged, it is importantto touch up the paintto protect from future corro- sion. The touch-up paint kit includes the necessary paintto correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit I Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator (oil not included). G007005-0 WI-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring Monitor the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected powerfailure. Status alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0 (50 amp) Smart Management Module Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages large G007006-0 (100 electrical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can amp) reduce the overall size and cost of the system. G007169-0 Mobile Link® Cellular The Mobile Link family of Cellular Accessories allows users to monitor generator status from anywhere in the world, Accessories using a smart phone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account with an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. Dimensions & PCs 72 12 - - L-- -] LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GG N E R AC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2020 Generac Power systems, Inc. All rights reserved. All spec'rfications are subject to change without notice. Part No. A0000221268 Rev. B 05/28/2020