HomeMy WebLinkAboutBottonne4-
Business & Professional •~a•1
• BCIS Home I tog In I User Registration Hot Topics Submit Surcharge i Stets & Facts k Publications FEC scarf SCIS Slte Map ! Links Search ;
I rida
USaductApproaal
USER: Public User
ro
Lr _,mei' rs
Product Aonrovel Menu > Product or Aoollcatton Search > Aoolicatten Ust> Application uamtl
FL #
FL17800-R2
.
Application Type
Revision
Code. Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer
IKO Industries, Ltd
Address/Phone/Email
40 Hansen Road South
Brampton, NON-US L6W 3H4
(708) 496-2800 Ext 200
rmetz001@tampabay.rr.com
AUthorized•Slgnature
Robert Metz
rmetz001@tampabay.rr.com
Technical Representative
Bob Metz
Address/Phone/Emall
. REMCO of Pinellas
456 Avila Circle NE
Saint Petersburg, FL 33703 .
(727) 776-5261
rmetz001@tampabay.rr.com
Quality Assurance Representative
Don Shaw
Address/Phone/Email
IKO Industries LTD
120 Hay Rd.
Wilmington, DE 19808
(717)579-6706
don.shaw@iko.com
Category
Roofing
Subcategory
Asphalt Shingles
Compliance Method
Test Report
Testing Lab
PRI Construction Materials Technologies, LLC
Quality Assurance Entity
FM Approvals - QA
Quality Assurance Contract Expiration Date
12/31/2020
Validated By
Locke Bowden
2 Validation Checklist - Hardcopy Received
Certificate of Independence
F1,17800 R2 COI FM-COI 2015Xdf
COI PRT CMT Cert of Independence odf
F 17800 22
Referenced Standard and Year (of Standard)
Standard Year
D3161 Modified to 110 MPH 2016
D3462 2010
E108 20il
TAS 100 1995
TAS 107 1995
Equivalence of Product Standards
Certified By
Approved Certification Agency
-"ar D3161 letter - f9-7h-20171 from
ASTM
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
FMTpdf
FL17800 R2 Eouiv Letter - ASTM E108 letter - (9-26-2017).odf
Method 1 Option 5
10/23/2017
10/28/2017
10/30/2017
12/12/2017
FL fie Model, Number or Name
Description
17800.1 Dynasty laminated Shingle
A Cambridge type laminated shingle with an additional
relnfinrcing tape applied to the specific normal nail line area
Identified as Armourzone that provides for enhanced nail pull
resistance for the shingle.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other:
Installation Instructions
F1,17801) R7 II DvnastV Application Instructions.odf
FL17800 R2 II TKO -186-02-01 Letter - Installation
Instructions fx—FBr g t7Rnn for Intl code 10-27-2017.12df
Verified By: Duc T Nguyen 65034
Test Reports
FL17S00 R2 TR 3013597 - Dynasty shingle pdf
FL17800 R2 TR IKO-125-02-01 KE Dynasty TAS 107
D3161.pd
FI 17800 R2 TR IKO-127-02-01 KE Dynasty D3462.pdf
FL17800 R2 TR IKO-148-02-01 Report -TAS 300 for
Dynasty ((Kankakee ILI (6 nails).ndf
Seek Next
Contact Us :: 7601 Blair Stone Road. Tallahasc-" ZIS-2 Phone: 850-487-1824
The State of Florida Is an WEED employer. CGRvdG`t 2bD7-2013 State of Florida. privacy Statement ;: dates=_;bl0ty Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The
emalls provided may he used for official communication with the licensee. However email addresses are public record. If you do not wish to supply personal ersonal address,
please provide the Department with an email address which can be made available o the public. To determine if you are a licensee under Chapter 455, F.S., please
Product Approval Accepts;
®®®19®
Credit Card
Safe
:DynastyCArnrii�urzane. Sh.ingfes
Ap:pM :cation si.
DIRECTIONS`•... : • .....:: ,., .. ....., :.... •.. .. .:...,..... � ..
NOTE: SHINGLES MUST BE APPLIED PROPERLY. WE ASSUME NO RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING
FROM POOR.APPLICATION OR FAILURE TO PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO
PROVIDE PROPER VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS. REVIEW
ALL APPLICABLE BUILDING CODES,. MINIMUM PROPERTY STANDARDS AND REQUIREMENTS PRIOR TO APPLYING THESE
SHINGLES USING THE APPLICATION INSTRUCTIONS FOUND ON THE WRAPPER. PLEASE USE CAUTION WHEN STACKING
BUNDLES ON SLOPED ROOFS.
ROOF DECK: Must be smooth, firm, dry and securely nailed. Plywood must be exterior grade, conforming to building
code requirements. Half-inch plywood is recommended for best deck performance. The Installation of asphalt shingles on
dimensional lumber'(including shiplap/board decks) is -not recommended as it may potentially cause buckling problems.
Buckling is riot covered by our Limited Warranty. REROOFING:.Split'and re -nail curled or buckled shingles, replace -any
missing shingles, remove loose or protruding nails, and sweep surface clean. Roof slope should be 4:12 or steeper. For
slopes 4:12 to 2:12, see special underlayment requirements outlined below. Never apply asphalt shingles to roof slopes
less than 2:12.
EAVE PROTECTION: Apply eave protection as per building code requirements, overhanging eaves by a nominal 1/4"
minimum and extending up the .roof at least 24" beyond the interior wall line. ice & Water Protector is recommended for
best performance, applied according to instructions printed on each wrapper.
UNDERLAYMENT: For areas where the roof slope is less than 4" per foot down to 2" per foot, use one layer of ICE AND
WATER PROTECTOR,.applied according to instructions printed. on each wrapper; Alternately, use 2 layers of asphalt
saturated felt (or equivalent), the first sheet overlapping the eave protection by 191, followed by full 36" widths
overlapping each preceding course by 19". (NOTE: IF THESE PROCEDURES. ARE FOLLOWED, SHINGLES APPLIED TO SLOPES
3:12 TO 4:12 WILL BE WARRANTED FOR THE FULL WARRAN'T'Y TERM FOR THE SHINGLE. SHINGLES ON SLOPES 2:12 TO
3:12 WILL BE WARRANTED FOR 12 YEARS.) For areas where the roof slope is 6" per.foot down to 4" per foot, it is strongly
recommended to lover the remainder of the deck with one ply esphalt saturated felt (or equivalent) laid parallel to the
eaves, with 2" horizontal laps and 4"' end laps. Apply metal drip edges on top of any underlay. -along rake edges and
directly to the deck*along eaves.
CHALK LINES: Sufficient chalk lines should be struck -to ensure accurate vertical and horizontal alignment of shingles.
Vertical chalk lines every 4 to 5 shingle lengths are recommended.
FLASHINGS: Base flashing should be in place before shingles are applied. Cali flashings of sheet metal and base flashing
of metal or mineral surfaced roofing should be used at chimneys, skylights, vents, walls and other vertical surfaces and
sealed with asphalt plastic cement. Flashing shall conform to the requirements of applicable building codes and good
Fw_n—etv Armourzone. ADDlns $TrDYAZEf5.2015-05_reformatted 2015.05
Page 1
Dynasty Armourzone Shingles.
Application Instructions
NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long .enough
to penetrate through plywood or 3/4" into boards. Use. 4 nails per shingle placed in the nailing area, either between
the lines or on the lines, spaced as shown below. Drive nails straight so that nail head is flush with, but not.cutting into
shingle surface.
NAILING ON STEEP SLOPES: On slopes. of 21" per foot (600) or more, use 6 instead of 4 nails per shingle placed. as shown
below. Ensure that no nails is within 2" of a' joint/cutout of the underlying shingle. NOTE: Each nail MUST penetrate both
layers of the shingle by nailing into the lower nail line only. Normal nail zone cannot be used to ensure penetrating both
layers. Seal down each- shingle at time of application with three 1 " diameter (approx. size and thickness of a quarter)
spots of asphalt plastic cement placed under the shingle 7" above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderationsince excessive amounts may cause blistering. CAUTION: Shingles should seal to the
underlying course when the factory applied asphalt Sealant is sufficiently warmed by the heat of direct sunlight. When
application conditions might limit the effectiveness of the sealing strip, such as in cool weather or in areas subject to high
windsor blowing dust, shingle adherence should be ensured through manual sealing as described above.
To ensure coverage under the High Wind Resistance Limited Wind Resistance Warranty;
- Manual sealing is not required in the state of Florida.
- starterstrip shingles mustbe used at all eaves. Rake application ofstarterstrips is not required.
OPEN METAL VALLEY: (FIGURE 1) For longer roof performance, metal valleys are recommended. Complete valley flashing
before shingles are applied. Center a 36" width strip of ICE & WATER PROTECTOR (A) in the valley. Ensure flashing is tight
to the deck, then fasten with only enough nails to hold in place, nailing at the edges only. Center a minimum 24" wide,
minimum 28 gauge pre-finished/galvanized metal valley liner (B) in the valley, and fasten with only enough nails to hold
in place, nailing at the edges only. Snap two chalk lines (C) the full length of the valley, 6" apart at the top and increasing
NAILS
rage c
CEMENT
STEEP SLOPE NAIL
PLACEMENT
2015 -as
OEM
I ME
I
CEMENT
STEEP SLOPE NAIL
PLACEMENT
2015 -as
Dynasty Armouraone Shingles
Application Instructions
in width 1/8" per foot towards the bottom. When the shingles are
m
being applied, laytheover the valley flashing, trim the ends to
the chalk line, and cut a 2" triangle off the comer to direct water
into the valley (D). Embed the valley end of each shingle into a 3"
band of asphalt plastic cement (E),.and nail the shingles 2" back
from the chalk line, 7 3/8" down from -the top edge of the shingle.
CLOSED CUT -011 WOVEN VALLEYS ARE ALSO ACCEPTABLE.
STARTER COURSE: (FIGURE 2) Use Leading Edge Plus shingles or
if 3 -tab shingles are used, cut off the tabs along a line level with
the top of the cutouts. Install the starter course with the factory
applied sealant adjacent to theeaves overhanging the rake edge
and eaves by a nominal 1/4" minimum. Begin starter course (A)
with a •shingle cut 4" short so that joints will not coincide with
joints between first course shingles.
FIRST COURSE: Start with a complete shingle applied flush with
starter course at rake and eave (B). Nail as described above and
continue across roof with full shingles.
SECOND, THIRD AND FOURTH COURSES: (FIGURE 2)
Trim off 10", 20", and 30" respectively, from the left
end of the starting shingle and apply to overhang
rake edge by 1/4' to 3/811. Continue each course
across the roof with full shingles butting ends loosely.
Align the bottom. edge of the shingles with the tops
of the saw teeth of the shingles in the underlying
course (C). Note that other offsets between 4" -10"
are permitted.
FIFTH AND SUCCEEDING COURSES: Repeat the
sequence of the first four courses up the roof.
For maximum wind protection, cement shingles
at rake edges.
eEr_1 Erre
FIGURE 2
UNDERLAYMENT
METAL DEEP EDGE
2015.05
CONSTRUCTION MATERIALS
TECHNOLOGIES
October 27, 2017
IKO Industries, Ltd
120 Hay Rd.
Wilmington, DE 19809
Re: FBC FL17800
Sir(s),
PRI Construction Materials Technologies has completed a technical review and attached sealed shingle
instructions in compliance the 2017 Florida Building Code.
This review was completed based on the receipt of following evidence from IKO Industries,. Ltd:
1) IKO DynastyArmourcone Shingles Application Instructions
(EN -Dynasty Armourzone Appins 8TTDYAZEFS-2015-01 reformatted 2015-02)
2) ASTM D3161 / FBC (HVHZ) TAS 107 Test Report (PRI Project No. IKO-125-02-01)
3) FBC,(HVHZ) TAS 100 Test Report (PRI Project No. IKO-148-02-01)
The attached instructions should be used in conjunction with the published manufacturer's application
instructions and applicable code. In the event the instructions conflict, these instructions shall govem.
Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not
have nor plan to acquire a financial interest in any company manufacturing or distributing products for which
the test reports are issued. .
1L / ,
Signed: Signed:
Brad Cirryb s Dnc L g en
j Managing rector Florida R r Professional Engineer
P.E. Number. 55034
Date: October 27, 2017 Date: October 27, 2017
Attachments: A) IKO Dynasty Armourzone Shingles Application Instructions
IKO-156-02-01
PPIC=tructlonMate<ialsTechnologies,LLC. 64128adgerDas 7ampa,FL33610 Tel:813-621-5771 F=813-621-5840 a-mekmatedelat dllg@pricmt= WebSite,EflpJMWf#,Pdrmtwm
IKO
Installation Instructions for
Asphalt Shingles
Page 2 of 2
IKO Dynasty Armourzone Shingle Application Instructions
(ASTM D3161, Class F — IKO Dynasty Armourzone. Lamiinated Shingle)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONDUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT, THESE INSTRUCTIONS WILL GOVERN.
ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC.
UNDERLAYMENT: Applied in accordance with building code requirements. Forareas where the roof slope is
less than 4" per foot down to 2" per foot, use 2 layers of undedayment conforming to building code
requirements, the first sheet overlapping the .eave protection by 19", followed by full 36" widths overlapping
each preceding course by 19" or other Approved underiayments in accordance with the qualified application
instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of
underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top
of any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements.
NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/$" diameter heads, long
enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed in the nailing area,
either between the lines or on the lines, spaced as shown below. Nailing area is 1-1/4" wide and located 6-
5/16" to 7-9/16" below the top edge. Drive nails straight so that nail head is flush with, but not cutting into
shingle surface.
Additional for FBG (HVHZ): Asphaltic shingles shall be installed in accordance with RAS 915. Installation shall
be limited to a roof mean height of 33'. Use 6 approved roofing nails (e.g. approved 12 gauge by 1-1/4'
corrosion -resistant annular ring shank roofing nails) per shingle as shown below for steep slope nail
placement, except asphalt plastic cement is not required.
NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (600) or more, use 6 nails per shingle placed
as shown' below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each
shingle at time of application with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt
plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the
'teat of direct sunlight.
EXPOSURE: installed shingles shall have a maximum average exposure of 5-7/8".
� f
6378' __.�_ ...
M 171
NAILS
STEEP SLOPE NAIL
PLACEMENT
--------------
s}
1 -
CEMBU
PRI Construction Matedals Technologies, LLC. 641213adgerDbe Tampa. k33610 Tel:8*621-5W FMC BS621-WO a -mail: matedal3tes#ng@pdcmtcom WeMte: http:/AwN- ricmt.00m