Loading...
HomeMy WebLinkAboutProduct approvals, windows10/28/2020 77 Florida Building Code Online C1 pFX P @ � C C r }:�vj,d+j g/AAf"YarH 46i+q f� g 'R' m 17 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL14911-R11 Revision 2017 Approved 'File Copy REVIEWED FOR BODE COMPLIANCE ST, L CIE COUNTY BOCC 101l9fZ6 Silver Line Building Products Corp. One Silverline Drive North Brunswick, NJ 08902 (800) 542-9118 Ext413596 luanne.harris@cornerstone-bb.com Jon Berrian jonberrian@slbp.com Jon Berrian One Silverline Drive North Brunswick, NJ 08902 (732)435-1000 jonberrian@sibp.com Windows Single Hung Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Hermes F. Norero, RE. Evaluation Report Florida License PE-73778 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality Assurance Contract Expiration Date 08/03/2021 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL14911 R11 COI COI Silverline SS 2017-06-14.pdf Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA/101/I.S.2/A440 2008 AAMA/WDMA/CSA/101/I.S.2/A440 2011 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 ASTM E1996 2012 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 https://floridabuilding.orgtpr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj59%2fDrx21 btdSCx8gXOAG%2bvoMHV6Fk8dHGU%2f4khcg%3d%3d 1/3 10/28/2020 Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/17/2018 Date Validated 10/14/2018 Date,Pending FBC Approval 10/08/2018 Date Approved 10/18/2018 Date Revised 10/25/2020 Cummary of Products FL # Model, Number or Name Description 14911.1 VI Series/50 Series (2000) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use. 14911.2 �Vl Series/50 Series (2111) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use. 14911.3 l VI Series/50 Series (2200/2300) .. ... _ ..................._..__ _ ._.. _ . . Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use. 14911.4 V1 Series/70 Series (2127) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use. Single -Hung Window Installation Instructions FL14911 R11 II SWD017 SS 2018-10-11.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL14911 R11 AE PER5140 SS 2017-10-20.pdf Created by Independent Third Party: Yes Single -Hung Window ..... _.... ...... ..-.__- _-_._..-----------.._..-_.-------._ .. _....---------j Installation Instructions FL14911 R11 II SWD018 SS 2018-10-11.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL14911 R11 AE PER5141 SS 2017-10-20.pdf Created by Independent Third Party: Yes Single -Hung Window Installation Instructions FL14911 R11 II SWD019 SS 2018-10-11.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL14911 R11 AE PERS142 SS 2017-10-20.pdf Created by Independent Third Party: Yes Single Hung Window Installation Instructions FL14911 R11 I1 SWD049 SS 2018=10-1l.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FI-14911 R11 AE PER5485 SS 2018-02-14.pdf Created by Independent Third Party: Yes �. 14911.5 I Vl Series/70 Series (2127) Single -Hung Window I Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL14911 R11 II SWD050 SS 2018-10 il.pdf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Impact Resistant: Yes Created by Independent Third Party: Yes { Design Pressure: N/A Evaluation Reports Other: See Installation Instructions and Product Evaluation FL14911 R11 AE PER5486 SS 2018-04-19.pdf i Report for allowable design pressures, sizes, installation } Created by Independent Third Party: Yes i requirements and limits of use Il _ __� _.... _ — ... — 14911 6 Vl Series/70 Series (2907/4907) Single -Hung Window Limits of Use Installation Instructions https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj59%2fDrx2l btdSCx8gXOAG%2bvoMHV6Fk8dHG U°/a2f4khcg%3d%3d 2/3 SILVER LINE BUILDING PRODUCTS CORP. V1 SERIES170 SERIES SINGLE HUNG WINDOW (2127) (IMPACT RA TED) (HVHZ) GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT EDITION FLORIDA BUILDING CODE (FBC), INCLUDING HVHZAND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06/09/12 • AAMA/WDMA/CSA 101/I.S.2/A440-08 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2X FRAMING, AND METAL FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION 15 THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. IX AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN NON-HVHZ AREAS. IN HVHZ AREAS, ONE TIME PRODUCT APPROVAL TO BE OBTAINED FROM MIAMI-DADE PER OR AHJ. S. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. WINDOW FRAME MATERIAL: PVC 7. IN ACCORDANCE WITH THE CURRENT EDITION FBC, WOOD COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN CHAPTER 23. B. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 GLASS CHARTS. SEE SHEET 1 FOR GLAZING DETAILS. MAX OVERALL SIZE CONFIG. DESIGN MISSILE WIDTH HEIGHT PRESSURE IMPACT RATING 52" 73" O/X +55 /-60 PSF LMI/SMI TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 - GENERAL NOTES & GLAZING DETAIL 2 - ELEVATION & ANCHOR LAYOUTS 3 - VERTICAL SECTIONS 4 HORIZONTAL SECTIONS S HORIZONTAL & VERTICAL SECTIONS, INSTALLATION NOTES & REINFORCEMENT DETAILS EXTERIOR STEELSPACER 1/8" OR 3/32" SETTING BLOCK 43/64" O.A. I.G. LAMINATED GLASS CONSISTING OF: 1/8"ANNEALED GLASS 7/32" STEEL SPACER 0 ANNEALED GLASS F-3/32" 0.090"SAFLEX PVBINTERLAYER 8Y 0.09 EASTMAN CHEMICAL COMPANY ANNEALED GLASS INTERIOR MIN. GLASS BITE 7/16" 1 QQS CFAI ANT GLAZING DETAIL 1 NOTE: ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH SAFETY GLAZING REQUIREMENTS OUTLINED IN CURRENT FBC AND ASTM E 1300 GLASS LOAD RESISTANCE. Af Silver Line hrAndc�sei5 ONE SILVERUNE DRIVE NORTH BRUNSWIM, NJ 08902 zyy LwJ.7� z N e G2Sm N 3 0 z0 0d3M2a ,0 ~Z a g4Q L)• 3m•As z �3 �z o 3 wz z� z DO M z N = m m w r H w w a mmwmal.w .OF NEiAJEE PJ 84RE7JL� d.E EIARIDA PZ N. 73 BUOJNNC WW% INC 39B L DN BEAM M / J3B ONOA BFACN, R ]3004 FBPE CEW. M MU ORJZAIIM N. 21) lS FL M: FL14911 DATE: 01.23.18 DWG. BY: CHK. BY: HR HFN SCALE: NTS owG. u: SW D050 I F 5 MAX. O.A FRAME WIDTH 52" MAX. D.L.O. WIDTH 47.69" A B MAX. FROM 3 3 COO RNERS 6" MAX. MAX. D.L.O. "0" O.C. 0 HEIGHT33.50" C 4 MAX. O.A FRAME HEIGHT 73" D 4 MAX. D.L.O. X. "XI,HEIGHT 33.50" 3" MAX. FROM CORNERS ELEVATION SINGLE HUNG WINDOW _ 6" MAX. 6.25" MAX. O.C. FROM I� CORNERS NOTE: ALL FASTENERS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK MUST BE FLAT HEAD 12.50" MAX. O.C. ANCHOR LAYOUT NAIL FIN - SINGLE HUNG WINDOW 6.25" MAX. FROM CORNERS ANCHOR LAYOUT THROUGH FRAME - SINGLE HUNG WINDOW Silver Line hiYitl(JClSCh ONE SILVERLINE DRIVE NORTH BRUNSWICK, NI O89O2 PH: (BDO 2U4228 J r U � Z�yy O -Ca' 0 z_ a Z !S w Z o DO 3 m .. a REMARKS BY DATE ``tttttltl tll/1//'/ q N 7 7� S A OF 'ck HERL68 CI bOREAd�a.E. FUIBDA P.E. No 7S1T8 BUILDING DROPS, INC 388 E II. eEw. BIL ONUA FTiAMO FL OPE CERT, OF AUTNORIIATION pI NaN20528 FL tt: FL14911 DATE: 01.23.18 DWG. BY: CHK. BY: HR I HFN SCALE: NTS DWG. a: SWD050 I SECTION FOR INTERIOR BLOCK & TACKLE SEE GLAZING BALANCERS o\ DETAIL SHEET 1 I p /— \ / J EXTERIOR D.L.O. MAX. FRAME WIDTH HORIZONTAL SECTION (� UPPERSASH SEE GLAZING DETAIL SHEET 1 INTERIOR EXTERIOR D.L.O. MAX. FRAME WIDTH HORIZONTAL SECTION 4 LOWER SASH SECTION FOR SEE GLAZING CONSTANT FORCE DETAILSHEETI BALANCERS SEE GLAZING DETAIL SHEET 1 I- Silver Line IvAnderseri ' ��4 .;1 ONE SILVERUNE DRIVE NORTH BRUNSWICK, NJ U902 PH: IBM23"228 j V z� z z � ^m cc oz a 1z7`��E w Us 2 J 3 m CO m � 2 > m UU w r I- z � a a .� v STAX OF 7���"�I�vMAI_ HEIOIEE iP 7! Fl.pBDA Na ] 8 INCBURDMG D N. ROGE ! 388 E ONM Br BLVD. / 338 DNBA R ]30D1 veae ever. OF AUTH wTHownmoH N. 2n57e FL #: FL14911 DATE: 01.23.18 DWG. BY: CHK. BY: HR I HFN SCALE: NTS DWG.#: SWD050 SHEET: `lf OF 5 IN SEE GLAZING DETAIL, SHEET 1 INTERIOR _ SEE GLAZING DETAIL, SHEET 1 VERTICAL SECTION 3 NAIL FIN SEE GLAZING DETAIL, SHEET 1 INTERIOR _ SEE GLAZING DETAIL, SHEET 1 VERTICAL SECTION 3 THRU FRAME Silver Line ONE.LVERUNE MVE NORTH aRUNSWICK, NJ 09902 RN: MW 1341228 W U � u h Z m E ZN ~ O y CL o O $ w m o oz � � P r ooaa�� 3 w Z � 7 > in m = > w r a ` F- REMARKS I BY I DATF \\l\ll{(il I7JJfJ v��s .Po p SA OF 'cr� FL= al xoRrsl.�di: F101LOA P.E. N9 , NC aim 8 oRors, me 399 E IA 9EACH BLVD. 059 oANu MAN, rt 330W iHRE =T. a AUTHORMATION Nw 29509 FL It: FL14911 DATE: 01.23.18 DWG. BY: I CHK. BY: HR HFN SCALE: NTS DWG.#: ;wDnSn OF J5 C t PERIMETER SEALANT J BY OTHERS MIN. SUBSTRATE EDGE DISTANCE /—BYOTHERS MIN. V11011A EMBEDMENT 1/4" MAX. SHIM SPACE EXTERIOR u INTERIOR VERTICAL SECTION 6 THROUGH FRAME (HEAD) 1/4" MAX. SUBSTRAT SPACE BY OTH ERS t\ INTERIOR EXTERIOR 1/4" MAX. SHIM SPACE INTERIOR p f PERIMETER SEALANT BY OTHERS EXTERIOR BY OTHERS SCREW IN THE INTERIOR CHANNEL MIN. EDGE DISTANCE SCREW IN THE EXTERIOR CHANNEL MIN. EMBEDMENT rff� HORIZONTAL SECTION 6 THROUGH FRAME (JAMB) MIN. EMBEDMENT SUBSTRATE r-- / BY OTHERS W W Z Z N O C=o O 1/4' MAX. SHIM SPACE EXTERIOR INTERIOR C HORIZONTAL SECTION 6 NAIL FIN (HEAD) REINFORCEMENT DETAILS 0 83" � � �0.87" [— 0.34" 11 f 0.13" 0.77" 9 I �'1 0.46" INTERIOR T 04� 0.06" 0.87' O LOCK RAIL ALUMINUM TOP O ALUMINUM LOCK NG RAIL O ALUMO UMW RAIL &SASH MIN. EDGE DISTANCE D� HORIZONTAL SECTION VERTICAL SECTION 6 NAIL FIN (JAMB) 6 MEETING STILE INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION OF THE MAXIMUM SIZE LISTED. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF 31/21NCH THE DEPICTED LOCATION & SPACING IN THE ANCHOR LAYOUT DETAILS (I.E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACKTO BE 3/81NCH. SHIM' WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. S. FOR MASONRY OR CONCRETE OPENINGS, 1X WOOD BUCK MAY BE USED (OPTIONAL AS LONG AS THE MINIMUM EMBEDMENT AND EDGE DISTANCE REQUIREMENTS ARE STILL MET WITHIN THE CORRESPONDING HOST SUBSTRATE. SEE GENERAL NOTE #3 ON SHEET 1 FOR MORE INFORMATION. 6. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. S. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 9. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 10. FOR INSTALLATION ANCHORS ABOVE THE MEETING RAIL IN THE INTERIOR IAMB TRACK, USE FLAT HEAD ANCHORS. ANCHOR SCHEDULE METHOD SUBSTRATE ANCHOR SCHEDULE MIN EMBEDMENT MIN. EDGE DISTANCE WOOD: MIN. SG=0.55 #8 WOOD SCREW I.S. 0.75' PAN HEAD NAILING FIN METAL: 18 GAUGE St-1, q0 TEK SCREW 3 THREADS MIN MIN. Fy = 33K51 PENETRATION BEYOND 0.50, METAL 010 PAN HEAD IN 1.5' 0.75' EXTERIOR CHANNEL WOOD: MIN. SO.0.55 010 FLAT HEAD IN THE 1.5' 0.75' INTEMORCHANNEL 010 PAN HEAD IN 3 THREADS MIN EXTERIOR CHANNEL PENETRATION BEYOND 0.50' METAL: 18 GAUGE SI-I, METAL THROUGH FRAME MIN. Fy = 33KSI NFLATHEAD IN THE 3 THREADS MIN INTERIOR CHANNEL IN PENETRATION BEYOND 0.50' METAL CONCRETE: Pc=3000PSI 9/16'ITWTAPCON 125' 1.75' FLATHEAD MASONRY: CMU Per ASTM 3/16'ITWTAPCON 125' 1.75' C90 MIN. 2000 PSI FLAT HEAD Silver Line 1m\rd&r &i ONE SILVERUNE DRIVE NORTH BRUNSWICK. M 09902 Vr O U m z A. E N� ESQ io m^8 O Uzz Np kDSW�Sa N3 �gW oo�`�' w (7 ¢QO J w 3 Ecz zt;Z 0— �m }m vW� > O o r F a REMARKS BY DATE 398 E DANIA BEACH BLVD. / 33B DANIA BEACH. FL 3300i FBPE CERT. OF AUMORIZATION N. 29578 FL #: FL14911 DATE: 01.23.18 DWG. BY: CHK. BY: HR HFN SCALE: NTS DWG.#: SWD050 I