HomeMy WebLinkAbout1st Floor Plan 2020 10 23 - KleinEXIST POOL WALL
1
EXIST. RD. WIN. -
NEW F.G. RD, WIN.
(MATCH EXIST. SIZE)
AHU ON SHELF - REMOVE
EXIST. W.H. (BELOW) - ADD
TANKLESS (GAS) W.H. TO
OUTSIDE
SOFFIT 5'
ABV. BUILT-IN
i
DEN
\ REMOVE EXIST,
\ FIR, DR, 8 S.L. -
NEW SL. GL, DR.
9 o" \
+'S\
O y
NEW PRE- F B. MTL,
FIREPL E - VERIFY NEW
FINIS W/ OWNER
LIVING ROOM
FLAT CLG.
\
\
J
NEW ROLL-DN
/ SCREEN FOR OPN'G.
BELOW BM.
Y
NEW ROLL-DN
SCREEN FOR OPN'G,
BELOW BM.
SC
F(
GENERAL ADDITION NOTES:
-THE DETAILS CONTAINED PER THESE PLANS MAY NOT BE
EXACT AND SHALL BE VERIFIED PRIOR TO ANY CONSTRUCTION
BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR).
-OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) SHALL NOTIFY
ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING
CONSTRUCTION.
-EXISTING CONDITIONS ON ADDITIONS/RENOVATIONS ARE TO BE
VERIFIED BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR)
EXAMPLE: EXISTING SOFFIT MATERIALS, EXTERIOR FINISHES, TRIM
MATERIALS, ROOFING MATERIALS, FASCIAS, ETC.
-OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) IS RESPONSIBLE
FOR PROVIDING AND VERIFYING DESIGN GUIDELINES AND
RESTRICTIONS PER SUBDIVISION'S ARCHITECTURAL REVIEW BOARD.
-M.A. CORSON 8 ASSOC, INC. SHALL NOT BE LIABLE FOR ANY LOSS,
DAMAGE OR INCONVENIENCE ARISING FROM INACCURACIES.
-CONTRACTOR TO HAVE CERTIFIED FLORIDA SURVEYOR
LAYOUT BUILDING ON LOT TO ASSURE THAT NO SETBACKS
OR EASEMENTS ARE ENCROACHED. (OWNER, 8 OR
— — — — — — — — \ CONTRACTOR, IS RESPONSIBLE FOR PROVIDING SETBACKS,
EASEMENTS, LOT COVERAGES, ETC.)
+ \ `
o,, \ \
O ` `
c0 \
x \
CNI <>
\
2 6 x 8 O J, cc'.` \
o,,
O
ID /REOOVE EXIST, \
CAST STONE TRIM - \
A +� ADD STUCCO TRIM \
OYER REPLACE (2) S.H.\ \
\ WIN, W/ NEW \
\ \ 14444 F.G. - VERIFY `
\ \ q +�q, SIZE (5 PLACES)
\ \d
\ \0 I I
\\\qs O I I
\ \ 0 I I
\ \ x I I
\ \ O I I
\ m2'611x 011 I I
RD. GONG.
COL,
I I +s o
I I
I I �
I I �
I 1 0
I I ow
I I: I 14 DINING ROOM
---•
I I
O
I I u
P
t
I I q
P O
I I
'
I I
'
I I
I I
ARCHED
— — — OPN'G_
' oven
1
tower
1
TF -L:::7�—
P.R.
'
\
OYO
♦ EXIST. SOFFIT ABV.
\ TO REMAIN
'
,
REMOVE EXIST.
SUPPLY
REF.REF
SUMMER KIT. ��
GAS
'
25' 4"
(BBQ 8 SINK)
TO ISLAND 16' O"
I
O O
REMOVE EXIST.
O ==
;
H.R. WIN. - NEW I
O
LARGER Ii'O"x8'0"
F.G. WIN. -VERIFY
I r----
KITCHEN
I
J�
{�
\EENED
CONC.IWALLBC/OLS.)
I REVEE EXIST. SOFFITS
[X
i i
#
RICH
I I
I
I
I
1
I
I
O
9'O'l CLG, HT.
1
\ I L_I__QW_J _L IG_L______,
I I
\--------------- 1 SPG6 O'
D NEW ROLL-N
SCREEN FOR OPN'G, REOEE EXIST, NON-BRG.
♦BELOW BM.0 WALLS
FIXED SCREEN
NEW STUCCO ON , ` \ ENCLOS. W/
BLK. RETAINING — — — DOOR — — — — —
WALL - MATCH ---_-----------
EXIST, SEE DETAIL ,
ON SHT, S
5' 115/5"
O +�
°j REMOVE EXIST.
NEW FOLDING GL. DR,
MORNING RM,
9'O" CLG. HT.
REMOVE EXIST.
S.H. WIN. - NEW
9'O"x(o'O" F.G. WIN.
VERIFY SIZE
3' 1"x6'4"
SH 26
F. 011
5 4"
3' IIIx o'41
SH 26
F. 011
TANKLESS
W.H. (GAS)
NEW - VERIFY
LOCATION
T' 6'l
WALL LEGEND
F,5,C, 2011 l(oTN EDITION) FOR
EXISTING BUILDiNGS
SUMMARY:
THE ALTERATION AREA HAS BEEN
DESIGNED TO- LEVEL 2
* Chapter 5 of the FBC 201-1 Existing Building
* less than 5051. of the aggreregate area
* The lateral -force -resisting system of the existing
structure is adaquate to withstand any new lateral
loads of the new addition per Section 501.5 of the
2011 FBC Existing Buildings.
* The existing residence has hardwired smoke alarms and
the new addition shall be hardwired and interconnected
to the exist, system where accessible Per R314.3
201-1 FBC,
THE ADDITION HAS BEEN DESIGNED TO- CHAPTER 5
*Chapter & of the FBC 2011 Existing Building
8 2011 FBC 8 CHAPTER 6 OF 48CE 1-10
HOLLOW 3 HATCHED =
EXISTING WALL TO REMAIN
SOLID = NEW WALLS
DASHED = EXISTING
---------- WALL TO BE REMOVED
4
U
4
>
W
iL
F
N
X
ul
SH 36
4' 5" x 6' 4"
I I
I I
I I
I I
R8S
4 O EXIST
STL,
COLS.
13' O"
5EDR00M 2
5'O"x5'3"
EXIST. H.R. (IMPACT)
(TO BE PAINTED WHITE)
-----------------------
-----------------------
GARAGE
°
I
9'10" CLG. HT, p x�j
a'2" ABV. (0'0' .F,F) m OLL
I '
I
o I I
I
II
I
I � o
I o
I (�
I
II
I
II
I _
' O
I '
ND
I LC
xLL
O
a" 24' 0"
I m
II
I
I '
-�'4" FIN. FL,
VARIES
I
NEW 8
----
________________ RELOCATEDI -
Panel Parpl
2, SIl
FIN. (RELOCATE)
FL. RELOCATE
4' 6" 3' 5 UP I m EXIST. VAC
REMOVE EXIST. I SH 36 I O fo I R LQCATED Q
4' 5 x 6' 4 2 6"
QUAD.WIN. - NEW-
3'O"x3'O" F.G. SQ.
w
IS
EXIST.
I I STEPS D .
I I O'O" FIN. FL.
I I °
T' 0 3' SI
AREA CALCULATIONS
Exist, let Floor a/c
3,405 S,F,
Exist. 2nd Floor a/c
1,301 S.F,
NEW 2nd Floor a/c
544 S,F.
Total A/C
5,250 S,F,
Garage
1,109 S,F,
Covered Patio
518 S,F,
Total Non A/G
1,621 S,F.
Total Under Roof
6,8l-t S.F.
* Contractors to verify all
footages
* All areas are calculated to
outside dimensions,
4'OIIx6'O"
F.G. W/ TRANS.
VERIFY SIZE
----------------------
II
I
GOLF CART
ro I
SO" CLG. AT,
I
I
I '
I
- - - - - - - - - - - - - - - - - - - - - - - '
Digitally signed
by Mark A
Mark A. Corson
Corson Date:
2 2 1 22 En
0 0. 0.
16:32:21-04'00'
---------- >
---------- Q
-- -------- 8 M
--- 3-9
ir---J I 4' 6"
61I 6"
-
-- --1 -T- 1 OELE\/+----------�
M DIFY FLAT GD ` 1 EQUIP, 1 I x 2
A V. (FL. DEPTH) 3 0 R6MOWE 1 1 1 I I = N
2ND L WALL ABV. l , E>{IST, W.;'
- - _-�- - - -�� EXIST. - - - - - 1 1'
I ' STL. J�U \D 1 11 1� 1 1 1 I IY
»������
L COL,
ul
r r 5 6 m 4 6 w Lu
U
I I
VAC 8"
0
F TANKLESS
13' O° W.H. (GAS)
NEW
' UJ.I.0
5EDROOM 3
OMIT SINK 8 ADD GAB, W/ IT O
KNEE SPACE
I �
LINE OF BALCONY COLS. / I I O NEW FREE
[PIERS ABV. TO BE REMOVED �p STANDING N
(a PLACES) TUB X U
.-- w LL
1
1� ` 0
F -1I �. MIR' �`-- ' MIR ° O -
5' O x 5' 3 EXIST. IMPACT
EXIST. H.R. (IMPACT)'
(TO BE PAINTED WHITE) F.G.
I NEW COND.
VLOJ
,a, EXIST. BLK. PRIVACY WALL
_
I �
I I
lL
>
5w 10"
O
z
- W
O91
>
z 0 z
- « m -
0 0 s 0 0
O�W
' .,- 3 N ��
q c 9
Q 0
4 N
0 O
zd)
c
0— �u�a�zo
v W
V N N 0 lL T
O?d
4N m SL3S "'4
Q) 0 3 3 N
•
u
z
z
V
O�
�
U
M
v
.4
OUrA
CIS
N
v
;3
eq
cis
�
N
�
O
O
"
O
N
U
•
DATE : 10/23/20
DRAWN BY pig me
CHECKED MC
REVISIONS