MIAMI-DADE COUNTY:
PRODUCT CONTROL. SECTION,'
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (PER) 11805 SW 26 Street;,' Room 208 j
B ARD AND CODE ADMINISTRATION DIVISION Miami, Florida 13175-2474
T (786) 315-2590 F (780) 315-2599
OTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv
Gardner Asphalt Corporation
4161 W. 7`a Avenue
Tampa, FL. 33605 Ae0c
SCOPE: �6J
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
duet ancrltatioi submitted has been reviewed and accepted by Miami -Dade County RER - Product Contro
l Section to be ;
u ed in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction 4�G1 t D D C.n r t
ti 1ItoL sEc rIO.,v
2(
is A s iajl not be valid after the expiration date stated below. The Miami -Dade County Productt",'
;
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to>Mvp thi )pTgdvo
qr t r al tested for quality assurance purposes. If this product or material fails to perform in the ggcq maKuae4, t$e
nac �cr will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
rQQ 1�°4)Ct or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
Perm rl¢d b},'N idt&Dade County Product Control Section that this product or material fails to meet the requirements
o rrli6 applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
inOudifig the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Gardner Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city[ state and fo11r ,'fig ^' ,
sta(ernent: ",Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has bccn no change
in [tie applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change 1,l the,;
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal ofNOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entircty.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the: Building Official.
This NOA revises NOA # 17-1221.15 and consists of pages I through 6.
The Submitted, documentation was reviewed by Alex Tigera.
MIAMI-DADE COUNTY
,...1 1
. 1t
NOA: 18-04091.0 6
Expiration Date: 03/28/23
Approval Date:. 05/10/18
Pagel of 6
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: Asphalt
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product
Description
Asphalt Saturated Felt underlayment, 2
square #30.
Product
ArOC Tuff --Felt 26 ,,s
Manufacturing
Location #1, 2
5 ,
IJ gdtFGUR20
rert, luring
ctg.;#1, 2
pp
Manufacturing
Location #1, 2
Nb.30 ASTIVI
Manufacturing
Location #1, 2
APOC Tuff -'Felt 46
M 1171!licturing
Location #1, 2
Chited'FGUR10
Mant facturing
Location #1, 2
AP6C45
Man'gi actu'ring
Locatiot3#1, 2
No: 15 ASTM
kanu%acturing
Location #1, 2
Nited FGUR70
Manufacturing
Location #1, 2
MIAMI-DADE COUNTY
Test
Dimensions Specification
36" x 72' rolls ASTM D 226 Type II
36" x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment. 2
square #30.
36" x 72' rolls ASTM D 226 Type II Asphalt Saturated; Felt underlaymcnt, 2
square #30.
,ct
36" x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt'uAV� Ia*1'e#W,11
square #30.
36" x 144' rolls ASTM D 226 Type I Asphalt Saturated'Feki Yi6
,'1a`3j]f i; 4.
square #15.
36" x 144' rolls ASTM D 226 Type I Asphalt Saturated Fe14 tinti'ellaji3'ent; 4
square #15.
36" x 144' rolls ASTM D 22.6 Type I Asphalt Saturated Felt uiuldlaymen't, 4
square #15.
36" x 144' rolls ASTM D 226 Type I Asphalt Saturated F'eit iin htlayrhe-0t', 4
square #15.
18" x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underl6yftietl'i;
square #30.
NOA: 18-0409.(16
Expiration Date: 03/28/23
ApproOal'Datei'-05/1(6 8
Page 2 of 6
z i ...nd9„ib
FRADI iNAMES,OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product '' 'I
Product Dimensions Specification Description ""
GatorSkin 42" x 285.8' rolls ASTM D 226 Type II Synthetic roof underlayment comprised
Manufacturing of layers of polyolefin film.
Location #3
GatorSkin-10
42" x 285.8' rolls
ASTM D 226 Type II Synthetic roof underlayment comprised
Manufacturing
of layers of polyolefin film.
Location #5
W&alher-Armor CX-L
37.25" x 145' rolls
ASTM D 226 Type II High strength hybrid underlayment
Manufacturing
comprised of two layers of polyolefin nno
Location #3
polyester synthetic fabric with a thiIn layer
of modified bitumen bdtAen the two
plies.
Weather -Armor SB-1
36" x 65' 8" rolls
ASTM D 1970 Glass fiber reinforced, polymer modified
Manufacturing
asphalt, granulated self -adhered
Location #4 '
underlayment.
Gard -Lock
36" x 65' 8" rolls
ASTM D 1970 Glass fiber reinforced, polymer modified
Manufacturing
asphalt, granulated self -adhered
Location-#4 -
underlayment.
iti 41 ).� !j� .•11t1
Weather -Armor HT'
39" x 65' 8" rolls
ASTM D 1970 60-mils thick (nommallyt) �s.w, a Fhiering
Manufacturing
membrane composed of4ibstio#dliymers,
Location #4
bitumen, glass rein£orcements aid -across
laminated sheet surfacing;'
Weather -Armor FT'
39" x 65' 8" rolls
TAS 103 60-mils thick (nominally)'sclAadhering
Manufacturing
membrane composed of elastic, I?Aymers,
Locution #4,,
bitumen polyester and glass
reinforcement.
NUFACTURING LOCATIONS:
], Tacoma, WA.
2. Eutaw, AL.
3. Hangzhou, China.
4. Springville, AL.
j.,,
5. Tampa, FL.
NOA: 1 H-0a0".06
Expiration Date:_63/28/23
Approval Date: 05/10/13
Page 3 of 6
EVIDENCE SUBMITTED:
Test A¢enev Test Identifier Test Name/Report " Date..
PT I Construction Materials GGI-100-02-01 ASTM D 226 06/22/12
Tt chnologies
GGI-101-02-01 ASTM D 226 06/22/12
GGI-132-02-01 ASTM D 226 04/28/15
GGI-176-02-01 ASTM D 226 09/26/16
GGI-178-02-01 ASTM D 1970 10/25/16
GGI-194-02-01 ASTM D 1970 08/04/17
GGI-196-02-01 TAS 103 08/08/17
GGI-206-02-01 ASTM D 226 03/09/18
GGI-207-02-01 ASTM D 226 03/Q9/18
GGI-201-02-01 ASTM D 1623 61/2`97i ,
GGI-178-02-01 ASTM D 1970 -.. '01%29/,$'�3 ;
GGI-178-02-02 ASTM D 1970 -. 0; 2�4`/,18
GGI-199-02-02 ASTM D 226 " I 2117
`A PROVED ASSEMBLIES:
n-,:1,
Deck Type 1:
Wood, Non -insulated
Deck Description:
'9h2" or greater plywood or wood plank i f.1 2 `' 1 o
System E(1):
Anchor sheet mechanically fastened to deck. K o-1:1 ;>0,,11k ,
,
3/OL"" 18
Anchor Sheet:
One or more plies of APOC Tuff -Felt 26, United FGUR20, United FGUR70, APOC 2-ijX ?' 30
ASTM, GatorSkin, GatorSkin-10 or Weather -Armor CX-L with a minimum 4" headlap"andl0"
end lap mechanically fastened to deck with approved nails and tin caps 6 inches o.c. mihitl it'b" ;
at all laps and three staggered rows fastened at 12 inches o.c, minimum in the field of
Nails shall be driven flush and 90 degrees to the roof deck.
Surfacing:
Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles qU ry
slate, metal roof applications, and as an anchor sheet in roof tile applications. Must Cor ly With
applicable Roofing Application Standards and Building Codes.
Deck TXpe <:
Wood, Non -insulated
Deck Description:
11/32" or greater plywood or wood plank
System E(2)::.
Anchor sheet mechanically fastened to deck.
Anchor Sheet:
Minimum 2 plies or more of APOC Tuff -Felt 46, United FGUR10, APOC 45, or No. 15-AST v1
with a minimum 19" headlap and a 6" end lap mechanically fastened to deck'witli appr6'v6W
nails and tin caps 6 inches o.c. minimum at: all laps and three staggered rows fastened at 12
inches o.c. minimum in the field of the roll. Nails shall be driven flush and 90 degrees to the
roof deck.
Surfacing:
Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, metal roof applications, and as an anchor sheet in roof tile applications. Must Comply with
applicable Roofing Application Standards and Building Codes.
MIAM4DADE COUNTY
• •
NOA: 18-0409,,06
Expiration Date: 03128/23
Approval Date:. 05/10/18
Page 4 of 6
Deck Type 1:
Wood, Non -insulated ri ts; t
Deck Description:
19/32" or greater plywood or wood plank
System E(3):
Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet:
One or more plies of ASTM D 226 Type lI or ASTM D 2626 with a minimum 4", headlap and.};,
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane:
One or more plies of Weather -Armor SB-1, Gard -Lock, or Weather -Armor HT''self-adhering
membrane adhered to the anchor sheet with a minimum 3" headlap and 6" end lap.
Surfacing:
Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarrya' '
1
slate, and metal roof applications. Must Comply with applicable Roofing Application $taii'dardst
and Building Codes.
Deck Type 1:
Wood, Non -insulated
D c4, pes.ertetion:
19/32" or greater plywood or wood plank d :
S�stem E(4):
Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type lI or ASTM D 2626 with a minimum 4" headlap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6"'6'c,.at thd:sidollap
edge and in a grid pattern spaced 12" o.c, in the field of the roll. al;
Membrane: One or more plies of Weather -Armor FT self -adhering membrane adhered to thO�an*4As e& r
with a minimum 3" headlap and 6" end lap. ct:iu, t,iva 3'
Surfacing: • Weather -Armor FT3 Shall be acceptable for use in approved asphaltic shingles, wot' d
shakes, & shingles, quarry slate, metal roof, and mechanically fastened roof the d
applications.
• Weather -Armor FT3 may be used with any approved adhered roof tile system as slikilis`A in
their current NOA using the following tile adhesives with current NOA:
• The Dow Chemical Company's TILE BOND Roof Tile Adhesive
" • ICP Adhesives and Sealants, Inc.'s ICP Adhesive Polyset AH-160
Must Comply with applicable Roofing Application Standards and Building Codes.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,
state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade Courn
Product Control Seal as shown below.
APPROVED
NOA: 1$ 6409.06
Expiration Dote: f 03A28/23
Approval Datel, 05/10/18
Poge 5 of 6
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following: u
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable' building code in order to properly evaluate
the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be, in compliance
with applicable building code.
3. Weather -Armor SB-1, and Weather -Armor FIT shall not be hot mopped; refer to manufacturer's published
literature for product compatibility. i,;
4. Gardner Underlayments listed herein are components used in roof assemblies. Roof assemblies areiapprove&
under specific assembly Notice of Acceptance.
_.. 'V ccukAarc
5. APbC-Tuff Felt 26, United FGUR20, APOC 25, No. 30 ASTM, APOC-Tuff Felt 46, United FGUR10,
APOC 45, No. 15 ASTM, United FGUR70, GatorSkin, GatorSkin-10 and Weather Armor CX-L listed
herein shall not be left exposed as a temporary roof for longer than 30 days of application.
6. Gard -Lock and Weather Armor SB-1 listed herein shall not be left exposed as a temporAry rddf forrlorigcy
than 90 days of application.
7. Weather -Armor HT and Weather -Armor FT3 listed herein shall not be left exposed as a teritpot&rptoof f'oe
longer than 180 days of application.
&. Gardner Underlayments listed herein may be used with any approved roof covering `Notide of Aoceplim, e
listing Gardner Underlayments listed herein as a component part of an assembly in the Notice of Acceptance.
If Gardner Underlayments listed herein is not listed; a request may be made to the Authority pyiim
Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided.A1at,
appropriate documentation is provided to detail compatibility of the products, wind uplift resistanceand fire,
testing results. s
9.. For, fire classification of specific roof assemblies using Gardner Underlayments listed herein refer to a
current Approved Roofing Materials Directory for fire ratings of this product.
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
Li;tar,;: i
M MI•DADECOUNTY NOAC 18-(1409106
Expiration Date: 03/28/23
Approval Date: 05/1.0/18