Loading...
HomeMy WebLinkAboutPolyglass MTS.pdf6/18/2020 Florida Building Code Online /Yl J a BCIS Home Log In Use, aegistraban Hot TOPICS Submit SurcluiMe Stats a Facts publuebms Contact us BCIS Site Map Lints Search dbpra)) Product Approval (I USER: Public User GrmuR Annmval Mnnu > Product of AnObraboc Search > Agpl¢atmn List > Application Detail FL * FL5259-R29 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1330 Ext 242 malpert@ polyglass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative TECH REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (866)802.8017 uspolyglasstechnical@polyglass.com Quality Assurance Representative QA REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888) 410-1375 uspolyglasstechniral@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/21/2022 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL5259 R29 COI 2019 01 COI NIEMINEN PAE Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2009 hops:llwww.floridabuilding.org/pr/pr app_d0.aspx?param-vGEVXQwtDgvbSgAaZp3Crk2vS%2fegOlipmaCfgJXCANGg3CNQhK30Sg%3d%3d 1/2 6/18/2020 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FL K• Model, Number or Name 5259.1 Polyglass Roof Underlayments Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-622.5 Other: 1.) The design pressure in this application relates to one particular underlayment system (over Concrete deck) for use under foam -on tile systems (where the underlayment forms part of the load -path). Refer to ER Section 5.6.1 for other systems, other deck types and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. Florida Building Code Online FM 4474 2011 FRSA/TRI April 2012 2012 UL 1897 2012 Method 1 Option D 10/15/20t9 10/16/2019 10/20/2019 12/10/2019 Description Roofing underlayments Installation Instructions FL5259 R29 II 2019 IO FINAL ER POLYGLASS UNDERLAYMENTS F 5 59- Verified By: Robert Nleminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL5259 R29 AE 2019 30 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- R29.R4f Created by Independent Third Party: Yes 49.0i0SLU5:: 2601 Blair Stone Read, Tallshassee Ft. 32399 phone: 850-487-181 The State of Florida is an Aa/EED employer. QW-W.Lgb 20D7-2m3 State of F[odtla.:: Edv y Statement v AccesslElley, statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic malt to Nis entity. instead, cuntaa the elate by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'pursuant to Section 455.275(l), Florida Statutes, eff dove October 1, 2012, licensees licensed under Chapter 455, F.S. must provide We De,s rtrnent with an email address If they have one. The emalls provided may be used for offidal communication with the licensee. However email addresses are public record. If you do not wish to supply is personal address, please provide the Department wind an ema I address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please csck here . Product Approval Accepts: M]Urelaq gnu M Security A3PTitiCS' https:IAvww.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXOMDgvbSgAaZp3Crk2vS%2fegOlipmacfgJXCANGg3CNQhK30Sg%3d%3d 2/2 NEMO l etc. Certificate Of Authorization #32455 '4 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY Polyglass USA, Inc. Evaluation Report P12060.02.09-R25 1111 West Newport Center Drive FL5259-R29 Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009 (954) 233-1230 Revision 25: 10/14/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOJetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO(etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 16 Prepared by: "': - Robert J.M. Nieminen, P.E. Florida Re(Jlgtfo[lon No. 59166, Florida DCA ANE2983 The facsimile seal appearing was authorized by Robert Nieminen, P.E- on 10/14/2019. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOI etc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC, LLC ONEMOletc. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 6" Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3 / 1507.1.1 Physical Properties ASTM D226 2009 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 1507.11.2 Physical Properties ASTM D6509 2009 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date Entity Examination Reference Date ERD ITST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD (TST 60491 Tensile adhesion P40390.04.15 04/03/2015 Ego (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 60491 TAS103 P44360.30.14-R1 05/18/2015 Ego (TST 6049) Wind Uplift PI740.01.07 01/04/2007 ERD (TST 6049) Wind Uplift PLYG-SC8905.05.16.1 05/17/2016 ERD (TST 6049) ASTM D1970 P5110.04.07.1 04/11/2007 ERD ITST 6049) ASTM D1970 PLYG-SC10130.06.16-1 06/27/2016 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/20DS Ego (TST 6049) Tensile adhesion PLYG-SC70130.06.16-2 06/27/2016 ERD (TST 6049) Wind Uplift P30540.11.09-R1 11/30/20D9 ERD (TST 6049) TAS103 PLYG.SCI0130.06.16.3 G6/27/2016 ERD (TST 60491 Tensile Adhesion P1I030.11.09.1 11/30/2009 ERD(TST 6049) ASTM D3970/D4798 PLYG-SC8080.07.16 07/16/2016 ERD (TST 60491 Wind Uplift P13030.11.09-2 11/30/2009 ERD (TST 60491 Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD (TST 60491 ASTM D4977 P11030.11.09.3 11/30/2009 ERD (TST 6049) TAS 103 PLYG-SC13040.12.16 12/27/2016 ERD (TST 6049) ASTM D1970 P33360.06.10 06/25/2010 ERDITS76049) 30/90 physicals PLYG-SC11900.03.17 03/10/2017 ERD (TST 6049) TAS103 P33370.03.11 03/02/2011 ERD ITST 6049) TAS103 PLYG-SC12115.08.17 08/08/2017 ERD (TST 6049) Tensile Adhesion P33370.04.11 04/26/2011 ERD (TST 6049) TAS103 PLYG-SC13035.G8.17 10/31/2017 ERD (TST 6049) ASTM 01970 P37300.10.11 10/19/2011 FM ITST 1867) Wind Uplift 3004091 01/12/2000 Ego (TST 6049) TAS103 P40390.08.12.1 08/06/2012 ICC-ES(EVL 2396) IBC Compliance ESR-1697 04/01/2019 ERD (TST 60491 Tensile Adhesion P40390.08.12.2 06/07/2012 M-D(CER 1592) HVHZ Compliance NOA 17-0614.22 07/06/2017 ERD (TST 60491 Tensile Adhesion C41420.09.12.3 09/I1/2012 MTI(TST 2508) ASTM D4798 1A2GH7A 04/01/2008 ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 NEMO (TST 6G49) ASTM D1970 4-PLYG-IB-004.03.18 03/29/2018 ERD (TST 6049) ASTM D1970 P45370.04.13 04/26/2013 NEMO (TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 01/11/2019 Ego (TST 6049) Wind Uplift 1`1738.02.07.R2 04/29/2013 NEMO (TST 6049) ASTM D6163 45-PLYG.18.002.01.19-A 01/24/2019 ERD ITST 60491 Wind Uplift 117ST04.01-1-RI 04/30/2013 NEMO ITST 6049) ASTM D6222 45-PLYG-18.002.05.19-C 05/20/2019 ERD (TST 6049) ASTM D6164 P37590.03.13.3A 05/06/2013 NEMO (TST 6049) TAS103 4S-PLYG-18.004.10.19-G 10/08/2019 ERD (TST 60491 ASTM D6509 P37590.03.13.1-R1 06/26/2013 NEMO (TST 60491 TAS103 45-PLYG.19-004.10.194 10/08/2029 ERD (TST 60491 Wind Uplift P41630.08.13 08/06/2013 NEMO (TST 60491 TAS1D3 4S.PLYG-18-004.10.19-L 10/09/2019 ERD (TST 6049) ASTM D4601 P45940.09.13 09/04/2013 NEMO ITST GD491 TAS103 4j-PLYG49-SSUDL-01A 10/10/2019 ERD (TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 PRI(T5T 5878) Tensile Adhesion PRI01111 04/08/2002 ERD (TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 PHI (TST 58781 TAS103 PUSA-018-02-01 07/14/2003 ERD (TST 6049) 30/90 physicals P45270.05.14 05/12/2014 PHI (TST 5878) TA5103 PUSA-035-02-01 09/29/2006 ERD(TST 60491 Tensile adhesion 6020.09.14.5 09/08/2014 PRI(TST 5878) TAS103 PUSA-055-02-02 12/10/2007 ERD (TST 60491 Tensile adhesion 6020.09.14.6 09/08/2014 PRI(TST 5878) ASTM D6222 PUSA-061-02-02 01/28/2008 ERD ITST 6049) Tensile adhesion P46520.10.14 10/03/2014 PRI (TST 5878) ASTM D6164 PUSA 088.02-01 07/29/ZG09 ERD (TST 6049) ASTM D1970/04798 P43290.30.14 10/17/2014 Polyglass USA P/LAf6davit Mule -Hide Cross Ltg 03/01/2008 NEMO ETC, U.C. Evaluation Report P32060.02.09-R25 Ctnif,,cote ofAuthomorion a32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlayments; (954) 233.1230 Revision 25: 10/14/2019 Page 2 of 16 Entity Examination Reference Date EnUN ERD(TST 6049) TAS 103 PLVG-sC7550.03.15 03/24121 Polyglass USA UL(QUA9625) C 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 NNEM131jetc. Examination Reference Date Materials Affidavit Polystick Compound 08/18/2011 Quality Control service Confirmation 09/13/2018 PRODUCT DESCRIPTION: Product Specification Plant(s) Description Elastobase ASTM D6163 FL Fiberglass -reinforced, SBS modified bitumen base sheet Elastobase P ASTM D6164 FL Polyester -reinforced, SBS modified bitumen base sheet Elastoflex G TU M-D 13-004 PA Polyester -reinforced, modified bitumen tile underiayment FRSA/TRI April 2012 composed of a sand -surfaced SBS modified bitumen back- side and granule -surfaced APP modified bitumen top -side Elastoflex S6 G ASTM D6164 FL Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TRI April 2012 Elastoflex 56 G FR ASTM D6164 FL Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TRI April 2012 Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI April 2012 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt TAS 103 waterproofing membrane, fiberglass reinforced, with a FRSA/TRI April 2012 polyester fabric surface Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet (FR) FRSA/TRI April 2012 Polyflex G ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRI April 2012 use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems Polyflex G FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRI April 2012 use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems Polyflex SA P ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI April 2012 Polyflex SA P FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI April 2012 Polyglass Base ASTM D6509 FL Fiberglass -reinforced, APP modified bitumen base sheet Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass -reinforced, asphaltic base sheet Polystick IR-Xe ASTM D1970 FL, PA Nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface Polystick MTS Plus TAS 103 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI April 2012 membrane, glass fiber reinforced, surfaced with polyolefinic film surface NEMO ETC, U.C. Evaluation Report P32060.02.09.RZ5 Certificate o/AuMonration 032455 (1 EDITION (20171 FRC NON-HVHZ EVALUATION F1.5259-1129 Polyglass Roof Underlayments; (954) Z33-1230 Revision 25: 10/14/2019 Page 3 of 16 NNEMOletc. 4. PRODUCT DESCRIPTION: Product Specification Plant(s) Description 4.18 Polystick MU-X ASTM D1970 FL, NV, PA Nominal 54-mil thick dual -layer rubberized asphalt (See Section 5.8) waterproofing membrane, fiberglass reinforced, with a polypropylene film surface 4.19 Polystick TU Max ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing TAS 103 membrane with a 190 g/m2 polyester fabric surface FRSA/TRI April 2012 4.20 Polystick TU P TAS 103 TX Nominal 130-mil thick rubberized asphalt waterproofing FRSA/TRI April 2012 membrane, glass-fiber/polyester reinforced, with a granular surface 4.21 Polystick TU Plus ASTM D1970 FL, PA Nominal 80-mil thick rubberized asphalt waterproofing TA5 103 membrane, glass fiber reinforced, with a polyester fabric FRSA/TRI April 2012 surface 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Wood Shakes Underlayment Asphalt Shingles Nail -on Tile Foam -On Tile Metal &Shingles Slate Elastobase Yes Yes Yes Yes Yes Yes (Base Sheet In 2ply system) (Base Sheet n 2-ply system) Elastobase P Yes Yes Yes Yes Yes Yes (Base Sheet in 2-ply system) (Base Sheet in 2-ply system) Polyglass Base No Yes Yes No No No (Base Sheet In 2-ply nWaa; IS.. Sheet In 2-ply m em) Polyglass G2 Base No Yes Yes No No No lease Sheet in 2-plyn tem) (Base Sheet in 2•piy system) Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6G Yes Yes Yes (See 5.5.1) No Yes Yes Elastofex 56 G FR Yes Yes No No Yes Yes HydraGuard Dual Pro Yes No No Yes Yes Yes HydraGuard Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Mule -Hide SA-APP Cap Sheet Yes Yes Yes (See 5.5.1) No Yes Yes Mule -Hide SA-APP Cap sheet(FR) Yes Yes Yes (See 5.5.1) No Yes Yes PolynexG Yes Yes Yes (See5.5.1) No Yes Yes Poly lea G FR Yes Yes No No Yes Yes PaIYRex SAP Yes Yes Yes (See 5.5.1) No Yes Yes Polyaex SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Polystick lR-Xe Yes No No No Yes Yes NEMO ETC, U.C. Evaluation Report P32060.02.09-R25 Cenirc re OfAerh rin.don g32455 6n' EDITION (20171 FSC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019 Page 4 of 16 NNEMOjetc. TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nall -On Tile Foam -On Tile Metal Wood Shakes &Shingles Slate Polystick Mrs Plus Yes Yes No Yes Yes Yes Polystick MU-x Yes No No Yes Yes Yes Polystick TU Max No Yes Yes (See 5.5.1) Yes No No Polystick TUP No Yes Yes (See 5.5.1) No No No Polystick TU Plus Yes Yes Yes (See5.S.11 Yes Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' Florida Product Adhesive Approval Underlayments DAP Foam Touch'n Seal StormBond FL14506 Polystick TU Max or Polystick TU Plus Roof Tile Adhesive Dow TileBond" FL22525 HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus Elastoflex G TU, Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP ICP Adhesives Polyset" AH-160 FL6332 Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule- ICP Adhesives Polyset° RTA-1 FL6276 Hide SA-APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus 5.6 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) Deck / (Optional) ASTM D41 plywood, OSB, Southern Yellow Pine or Huber HydraGuard Dual Pro, Engineered Woods "ZIP System" Panels HydraGuard Tile Pro, sheathing ASTM D41 structural concrete Polystick (all variations), Mule -Hide SA-APP Cap self- (Optional) ASTM D41 ASTM C1289 Type II Class 1 polyisocyanurate, ASTM Sheet, Mule -Hide SA-APP adhering Insulation or WB-3000 C1289 Type V polyisocyanurate-composite, DensDeck Cap Sheet (FR), Polyflex Prime or SECUROCK Gypsum -Fiber Roof Board Base N/A ASTM D226 felt, Elastobase, Elastobase P or Mule -Hide SA P or Polyflex SA P FR Sheet Nail Base Deck ASTM D41 structural concrete Insulation (Optional) ASTM D41 DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR hot asphalt Base ASTM D226 felt, Elastobase, Elastobase P, Mule -Hide Nall N/A Sheet Base or Polyglass G2 Base Deck ASTM D41 structural concrete Polyflex G or Polyflex G FR torch- Insulation (Optional) ASTM D41 DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board Base N/A Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass applied Sheet G2 Base or Polyglass Base I Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, U.C. Evaluation Report P32060.02.09-R25 Cenipcore afAuehonmtion 4324SS 6" EDITION (20171 FBC NON-HVHZ EVALUATION FL5259-RZ9 Polyglass Root Underlayments; (954) 233-1230 Revision 25; 10/14/2019 Page 5 of 16 ONEMOletc. 5.6.1 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: The following wind uplift limitations apply to underiayment systems that are not prescriptively addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on or mortar -senile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure = -52.5 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all OSB joints Base Ply: Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Pius, self -adhered. #2 Maximum Design Pressure =-90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #3 Maximum Design Pressure = -97.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1X" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure = -105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga, x lY:'ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-Inch D.C. #5 Maximum Design Pressure = -135 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #6 Maximum Design Pressure = -315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG300 or ASTM 041 Base Ply: (Optional) Polystick MTS Pius, self -adhered. Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #7 Maximum Design Pressure = -622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. NEMO ETC, U.C. Evaluation Report P12060.02,09.R25 CenifraN, ofAuNorirorion a32455 6'"EDITION (20171 FBC NON-HVHZ EVALUATION FL5259•R29 Polyglass Roof Underlayments; (954) Z33.1230 Revision 25: 10/14/2019 Page 6 of 16 NNEMOJetc. #8 Maximum Desien Pressure = -30.0 Dsf•: Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-Inch O.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TV Max, Polystick TU P or Polystick TU Plus, self -adhered. #9 Maximum Desien Pressure = -37.5 Dsf•: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TV P or Polystick TV Plus, self -adhered. #10 Maximum Design Pressure =-37.5 Dsf•: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type 11 felt Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #11 Maximum Design Pressure =-45 osf': Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type II felt Fasteners: 31 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c, at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TV P or Polystick TU Plus, self -adhered or Elastoflex G TV, applied in full mopping of hot asphalt. #12 Maximum Design Pressure =-45 Dsf": Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two (2) layers ASTM D226, Type It felt Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered or Elastoflex G TV or Elastoflex S6 G, applied in full mopping of hot asphalt. #13 Maximum Design Pressure =-45 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TV or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #14 Maximum Design Pressure = -45.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. NEMO ETC, U.C. Evaluation Report P12060.02.09-R25 Certificate of Authodration#32455 6"° EDITION (2017) FBC NON-HVHZ EVALUATION FLS259-1129 Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019 Page 7 of 16 NNEMOletc. #15 Maximum Design Pressure = -45.0 osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #16 Maximum Design Pressure = -45.0 Ds : Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #17 Maximum Design Pressure =-52.5 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #18 Maximum Desien Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #19 Maximum Desien Pressure =-52.5 osf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c, at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #20 Maximum Design Pressure = -60 osf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #21 Maximum Design Pressure=-60 osf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. NEMO ETC, U.C. Evaluation Report P32060.02.09-1125 Certificate ofauthanzatian x32455 6TH EDITION(20171 FBC NON-HVHZ EVALUATION F1.5259-1129 Polyglass Roof Underlayments; (9541 233-1230 Revision 25: 10/14/2019 Page 8 of 16 *NEMO etc. #22 Maximum Design Pressure = -60.0 osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. N23 Maximum Design Pressure =-60.0 osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. N24 Maximum Design Pressure = -60.0 osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: $-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. US Maximum Design Pressure =-67.5 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment) Fasteners: 12 ga. x 1.25-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 84nch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #26 Maximum Design Pressure=-67.5 osf Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Primer: (Optional) PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #27 Maximum Design Pressure = -67.5 DO: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. NEMO ETC, U.C. Evaluation Report P12060.02.09-R25 Certfcate o,FA.th.a=,.4032455 6°iEDITION (2017)FRC NON-HVHZ EVALUATION FLS259-R29 Polyglass Roof Underlayments; (954) 233.1230 Revision 25: 10/14/2019 Page 9 of 16 ONEMO etc. 928 Maximum Design Pressure = -67.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #29 Maximum Design Pressure = -75 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 30-inch o.c. at the 4-Inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #30 Maximum Design Pres<ure =-90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch D.C. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #31 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3' Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #32 Maximum Design Pressure = -90 osf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3- Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastofiex S6 G, applied in full mopping of hot asphalt. #33 Maximum Design Pressure=-90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #34 Maximum Design Pressure = -90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MIS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. NEMO ETC, LLC. Evaluation Report P32060.02.09-R25 Cenilirnte OfAuthwitatlon 432455 6"'EDITION (20171 FBC NON-NVH2 EVALUATION FL5259-R29 Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019 Page 10 of 16 ONEMOletc. #35 Maximum Design Pressure = -90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch D.C. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #36 Maximum Design Pressure = -90.0 osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #37 Maximum Design Pressure = -97.5 osf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #38 Maximum Design Pressure = -97.5 osf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #39 Maximum Design Pressure=-97.5 osf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 5-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mapping of hot asphalt. #40 Maximum Design Pressure = -97.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. 441 Maximum Design Pressure=-105 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-Inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. NEMO ETC, U.C. Evaluation Report P32060.02.09-R25 Cernfimte of Authorimticn#32455 6t"EDITION (2017)FRC NON-HVH2 EVALUATION FL5259-R29 Polyglass Roof Underlayments; (9S4) 233-1230 Revision 25; 10/14/2019 Page 11 of 16 NNEMO etc. #42 Maximum Design Pressure = -105.0 osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex $A P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #43 Maximum Design Pressure = -105.0 osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #44 Maximum Design Pressure = -105.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 64nch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #45 Maximum Design Pressure = -112.5 osf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG 100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MTS Plus, self -adhered Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #46 Maximum Design Pressure = -120 psf: Deck: Min. 15/32-inch plywood to meet Project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #47 Maximum Design Pressure =-120 osf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. NEMO ETC, U.C. Evaluation Report P12060.02.09-R25 Certificate GfAuthenmtion p32455 fin. EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlayments; (954) 233.1230 Revision 25: 10/14/2019 Page 12 of 16 ONEMOJetc. H48 Maximum Design Pressure = -127.5 osf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG300 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. k49 Maximum Design Pressure=-127.5 osf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch O.C. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. H50 Maximum Design Pressure = -127.5 osf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. 5.6.1.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.6.1.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table IA. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1.29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Maximum Exposure (days) Elastoflex G TU, HydraGuard Dual Pro, HydraGuard The Pro, Polystick MTS Plus, Polystick TU Max, Polystick TU P or Polystick TU Plus 180 Polystick IR-Xe or Polystick MU-X 90 Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base 30 180 Elastoflex S6 G, Elastoflex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (for adhesive -set tile) UNLIMITED (FR), Polyflex G, Polyflex G FR, Polyflex $A P or Polyflex $A P FR (for mechanically fastened roof prepared roof covers) 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970.15, should be established as to slip resistance. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1125 CeOifcate ofAuthoriration a32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof Underlaymenn; (9541 233-1230 Revision 25; 10/14/2019 Page 13 of 16 ONEMO etc. 5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Elastoflex G TU Flat 10-tile stack 7:12 Lugged 8-tile stack (6 over 2) 6:12 Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 HydraGuard Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS Plus Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Max Polystick TU P Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 10-tile stack 6:12 Flat 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nail Base: 6.3.1 Non -Tile Aoolications Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule - Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.1 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual. NEMO ETC, U.C. Evaluation Report P32060.02.09-1125 Cenirxme 0Aeth.,konn N32455 6-EDITION 12017)FBC NON-HVHZ EVALUATION FL52S9.RZ9 Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019 Page 14 of 16 6.4 6.4.1 6.4.2 6.4.3 6.4.4 6.5 ONEMOletc. HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick IR-Xe, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P or Polystick TU Plus: General: All seal -lap seams (selvage laps) must be firmly rolled with a in accordance with Polyglass requirements to ensure full contact and adhesion. For HydraGuard Dual Pro and HydraGuard Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Ovelap Senor of HydraGuard Dual Pro and HydraGuard Tile Pro Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements. Tile Applications /excludes HydraGuard Dual Pro, Polystick IR-Xe and Polystick MU-X): Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI April 2012 (04-12) and Polyglass published requirements. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.1 herein. Multi -Ply Underlavment Systems: Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable If a 2-ply underlayment system Is desired. Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR: 6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. NEMO ETC, LLC. Evaluation Report P12060.02.09-R25 Certificate olAvthomatian a32455 6n' EDITION (2017) FBC NON-HVH2 EVALUATION FL5259-R29 Polyglass Roof Underlayments; (954) 233-1230 Revision 25: 10/14/2019 Page 15 of 16 ONEMOletc. 6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 I Polyflex G or Polyflex G FR: 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04- 12) beneath mechanically fastened or adhered tile roof systems (Refer to Table 2 for base sheet options). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Refer to Table 2 for base sheet options). 6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Polyglass published requirements for file staging. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. Refer to Section 4 herein for product & production locations having met codified physical properties specifications. 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - NEMO ETC, U.C. Evaluation Report P32060.02.09-R25 Certificate ofAuthorlxotion C32455 6"'EDITION (2017)FOC NON-HVHZ EVALUATION FL5259-R29 Polyglass Roof UnderlaVraents; (954) 233-1230 Revision 25; 10/14/2019 Page 16 of 16