HomeMy WebLinkAboutHealth deprtment approvalAPPLICATION #: AP 1453375 STATE OF FLORIDA PERMIT #:56 -SF -2016735 DEPARTMENT OF HEALTH DOCUMENT # : FI 1523734 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:01/10/2020 FEE PAID.2 5.0 0 RECEIPT #:56 -PID -4263095 APPLICANT: Sergio Fernandez AGENT: Mike DiFrancesio (DiFrancesio Construction Inc.) PROPERTY ADDRESS: 18601 Tranquility Base Ln Port Saint Lucie, FL 34987 LOT: 18 BLOCK: 3 SUBDIVISION: Aero Acres ID#: 3215-801-0071-000-6 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1537.00 [2] 483.00 [ ] [27] SURFACE WATER FT [ ] [02] TANK MATERIAL Polypropylene [ ] [28] DITCHES FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS FT [ ] [04] MULTI-CHAMBERED [ L_!j N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL -68 [ ] [31] IRRIGATION WELLS FT [ ] [06] LEGEND 1. 70-143-16DC4 2. 70-143-54SC4 [ ] [32] POTABLE WATER 100 FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 9 FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES 31 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 792.4 [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 7.00 2. [ ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 10/23/2020 [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 3.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS 1.00 [ ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [23] FILL TEXTURE [ ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION or I APPROVED / St. Lucie CHD DATE: 09/09/2020 DISAPPROVED ] : En it mental specia ' c rian J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: St. Lucie CHD DATE: 10/23/2020 Environmental Spe ' r t II Brian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 40161 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1453375 EID2016735 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #: AP 14.53375 PERMIT #:56 -SF -2016735 DOCUMENT #: F11523734 DATE PAID:01/10/2020 FEE PAID:25.00 RECEIPT #:56 -PID -4263095 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 460 gpd. Tanks not installed. Buried FPL power line located in the incorrect area and will be moved. 7x10 long bed DF installed. No violations, DF ok to cover. Needs 2nd inspection for tank installed. New ST, filter, DT, and liberty 1/3 hp pump installed. No violations, system ok to cover. Needs final inspection for well inspection/setback, mound system, alarm check, and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1453375 EID2016735