Loading...
HomeMy WebLinkAboutCompaction TestHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB # :205338-2pd/CH/jo CONTRACTOR:A & G Concrete Pools PERMIT #:2006-0520 JOB LOCATION:8441 Muirfield Way NUC #417 Port St Lucie, Florida Nuc Model:3500 Nuc Serial #:3417 P.O. #:2006146/Lynch ITEM TESTED :Pool Backfill Compaction - Retest TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE PERCENT COMPACTION 1 Southwest 0'-1'40 108.8 110.6 98.4% 2 1'-2'40 -"95.0% + 3 2'-3'45 -"95.0% + 4 3'-4'45 -"95.0% + 5 Northeast 0'-1'45+109.2 110.6 98.7% 6 1'-2'45+."95.0% + 7 2'-3'45+-"95.0% + 8 3'-4'45+-"95.0% + 9 Southeast 0'-1'40 109.1 110.6 98.6% 10 1'-2'45 -"95.0% + 11 2'-3'45 -"95.0% + 12 3'-4'45 -"95.0% + Soil Description: Brown Sand with some Clay In Place Moisture: 11.4% Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 110.6 @ Test Locations the Density & Penetrometer reading indicate the Degree of Compaction Meets Minimum Requirement for Unplumbed Backfill Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 10/29/2020 Email to: St Lucie Building Department; ABirmingham@angpools.com SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 October 29, 2020 Disclaimer:Contractor is responsible to maintain the pool backfill in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the poolbackfill has been altered from the approved inspected condition. Proudly Serving Florida since 1990 107.0 108.0 109.0 110.0 111.0 112.0 8 9 10 11 12 13 14 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight