Loading...
HomeMy WebLinkAboutBuilding PlansCool and Cobb Engineering Company __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ 203 W. Main St. Avon Park, FL 33825 Office: (863) 657-2323 Fax: (863) 657-2324 Date:   10/19/2020  Job:   Mark Damanti  Location:   2052 Nettles Blvd.   Jensen Beach, FL 34957  PUSH PIER DESIGN ANALYSIS  The load requirements for the piers designed to assist in supporting the identified areas of the subject residence  were determined. The selected piling locations and the specific piling are identified on the Pier Identification and  Location Plan attached. The calculated total loads on the piers in the specific location, including both dead and  live loads are documented in the attached table which is designated as Attachment “A”. Based on the total load  requirements for each of these piers, the 5k driver is to be employed. The 5k torque driver should be employed  with a selected gauge pressure of _2,250____ psi, which will provide pile capacity, including the 2 to 1 safety  factor of _34,388___ lbs. which is greater than the maximum calculated total load of _16,200___ lbs. which  occurs on the pier identified as no. _1__. Based on this analysis, the use of the 5k torque driver for the piers with  a specific gauge pressure of _2,250___ psi and a minimum depth of 10’ is approved and certified as meeting all  of the requirements of the Florida Building Code 2017 6th Edition, and good engineering practice. This is not to  be the primary support structure, but a supplement support to assist in support of the weight of the structure,  which will reduce the total pressure on the existing soils. After completion of installation, Cool and Cobb  Engineering Company shall be supplied with a drilling log of the location and depths of each pile installed so they  can evaluate the installation and prepare the “As Built” drawings.  General Notes:  1.All piers to be installed in accordance with ICC ES AC 358 2.A log of each pier to be kept by Contractor noting depth and final torque installed for each pier. 3.Minimum pier depth to be 10’‐0” 4.All pier calculations are based on a maximum spacing of 6’‐0” 5.Push piers installed less than 48” apart are to be battered 10° away from each other. 6.This design is based on the loads of the structure placed on the shallow soils under the structure. 7.No deep soils geotechnical testing information was provided for this design. 8.This design does not address any possible sink hole activity as defined in Florida Statute § 627.706. __10/19/2020___  Carl Cool P.E.  State of Florida  Professional Engineer No. 16921  Job Details Alpha Foundation Specialists, Inc. 66 Industrial Park Monticello FL 32344 Job Location 2052 Nettles Blvd Jensen Beach FL 34957-3221 Page 2/5 10-19-2020 Two Story Residential Concrete Block Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825 Date: Job: Location: PILE NO. 1 16,200 lbs 2 16,200 lbs 3 16,200 lbs 4 16,200 lbs 5 16,200 lbs 6 16,200 lbs 7 16,200 lbs 8 16,200 lbs 16,200 lbs Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825 CA# 29713 Carl E. Cool, P.E. PE# 16921 Cool and Cobb Engineering Company Maximum Total Load on Pile: 10/19/2020 10/19/2020 Mark Damanti 2052 Nettles Blvd. Jensen Beach, FL 34957 Attachment "A" Total Load on Pile (Live Load + Dead Load) TOTAL CALCULATE LOAD 10/19/2020 Carl E. Cool, P.E. PE# 16921 Cool and Cobb Engineering Co. 203 W. Main St. Avon Park, FL 33825 10/19/2020 Carl E. Cool, P.E. PE# 16921