HomeMy WebLinkAboutRUi-SP-1-N Series Condensing Residential Indoor Spec Sheet• Concentric or Schedule 40 PVC/CPVC
• Direct Vent (Concentric and Twin Pipe)
• Non-Direct Vent (Room Air)
• Common Vent (Direct Vent and Room Air)
• Maximum Equivalent Vent Lengths:
SUPER-HIGH-EFFICIENCY (CONDENSING)
TANKLESS WATER HEATER
Installation Type Internal (Indoor) Residential
Applications. Manufactured (Mobile)
Home Certified
Model Numbers RU199i (REU-N3237FF-US)
RU180i (REU-N2934FF-US)
RU160i (REU-N2530FF-US)
RU130i (REU-N2024FF-US)
Approved Gas Types Natural and Propane
Uniform Energy Factor (UEF) RU199i, RU180i, RU160i: 0.93
RU130i: 0.91
Energy Factor (EF)
(Canada)
RU199i: 0.96
RU180i, RU160i, RU130i: 0.95
High Altitude Approved Up to 10,200 ft (3,109 m)
Water Flow Control Water Flow Sensor, Electronic Water
Control and Bypass Control
Controller Standard: Integrated Controller
Optional: MC-195T-US, MC-100V-1US,
BC-100V-1US, MCC-91-2US
Certifications AHRI, ANSI Z21.10.3, CSA 4.3, and
ENERGY STAR®
Warranty
• Heat Exchanger: 15 years or 12,000 operation hours, whichever
occurs first
• All Other Parts and Components: 5 Years
• Reasonable Labor: 1 Year
Safety Devices
Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM
Check, Over Current - Glass Fuse, Remaining Flame (OHS) and
Automatic Frost Protection
Included with Purchase
Tankless Water Heater, Wall Mounting Bracket, Pressure Relief Valve
and Adapter, Isolation Valve Kit, Vent Screens (x2), Vent Screen
Screws (x2) and Self-Tapping Screws (x2)
Additional Features
• Mobile Home Certified
• Complies with South Coast
Air Quality Management
District 14 ng/J or 20 ppm
NOx Emission Levels
• Ultra Low NOx
• Tankless Rack System™ Compatible
• 1/2 in. (13 mm) Gas Line Compatible
●
• Compact Design to Save Space
• Wi-Fi Technology for Remote Monitoring and Management
• Sliding Mounting Bracket for Easy Installation
• Simple Gas Conversion
Room Air Screen, Condensate Neutralizer, ScaleCutter, Drain
Down Kit, Additional Controllers, Pipe Cover, Recirculation
Pump, DPS/MIS Switch, EZConnect™ Cables, Control-R™
Wi-Fi Module, Wireless Accessories, and many more.
Visit rinnai.us for a complete list of accessories.
Vent Sizes 2 in. X 4 in. 3 in. X 5 in.
Vent Lengths 65 ft (20 m) 150 ft (46 m)
Vent Sizes 2 in. (51 mm) 3 in. (76 mm)
Vent Lengths 65 ft (20 m) 150 ft (46 m)
Twin Pipe
Concentric
Flow curves apply only to incoming water temperatures of 70° F (21° C) or less.
For incoming water temperatures greater than 70° F (21° C), please contact Rinnai.
1 Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
Minimum activation flow is 0.4 GPM (1.5 L/min). 2 The maximum gas supply pressure must not exceed the value specified by the manufacturer.
* 0 in. from vent components
** Clearance for servicing is 24 in. (610 mm) in front of water heater
*** Add 0.25 in. (6.35 mm) for recess box
in. (mm)
Vent Connection:
2 in. (51 mm)
nominal PVC/
Polypropylene or
3 in./5 in.
Concentric.
0 25 50 75 100 125 150
SPECIFICATION RU199i RU180i RU160i RU130i
Dimensions - w, h, d 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm)
Minimum Gas
Consumption Btu/h 15,000
Maximum Gas
Consumption Btu/h 199,000 180,000 160,000 130,000
Flow Rate1
(Min - Max)
0.26 - 9.8 GPM
(1.0 - 37 L/min)
0.26 - 9.0 GPM
(1.0 - 34 L/min)
0.26 - 8.0 GPM
(1.0 - 30 L/min)
0.26 - 6.6 GPM
(1.0 - 24 L/min)
Max Flow Rate with
Parameter Adjustment
11 GPM
(42 L/min)
10 GPM
(38 L/min)
9 GPM
(34 L/min)
7 GPM
(26 L/min)
Weight 64 lb (29 kg) 64 lb (29 kg) 62 lb (28 kg) 62 lb (28 kg)
Sound Level 48 dB 47 dB 47 dB 47 dB
Normal 84 W 65 W 52 W 38 W
Standby 1.3 W
Freeze Protection 148 W
Max Current 4 Amps
Fuse 10 Amps
Temperature
• Minimum: 98° F (37° C) Default • Maximum: 120° F (49° C) Default
140° F (60° C) With Parameter Adjustment
By-Pass Flow Control Electronic
Gas Supply Pressure2 • Natural: 3.5 in. w.c. - 10.5 in. w.c. • Propane: 8.0 in. w.c. - 13.5 in. w.c.
Ignition System Direct Electronic Ignition
Electronic Connections • Appliance: AC 120 Volts, 60Hz. • Temperature Controller: DC 12 Volts (Digital)
Water Supply Pressure • Minimum: 50 PSI (Recommended 60-80 PSI for max performance) • Maximum: 150 PSI
Controller Cable Non-Polarized Two Core Cable (Minimum 22 AWG)
Service Connections
• Gas Supply: 3/4 in. (19 mm) NPT • Cold Water Inlet: 3/4 in. (19 mm) NPT • Hot Water Outlet: 3/4 in. (19 mm) NPT • Condensate Drain: 1/2 in. (13 mm) NPT
Clearances Electrical • Top: 2 in. (51 mm)* • Bottom/Ground: 12 in. (305 mm) • Front: 0 in.**
• Back: 0 in. • Sides: 2 in. (51 mm)*** • Vent: 0 in.
NOTE: Maximum flow rates may vary based
on set temperature, Delta T and altitude.
COLD F 9.54 242
C 3.56 90
HOT H 14.27 362
B 6.16 156
GAS E 3.57 91
D 2.78 71
G 10.39 264 PRV A 7.60 193
Connection mm in.
SIDE
FRONT
BOTTOM