HomeMy WebLinkAboutRevised Energy Calcs FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 15 Block 5 Waterstone 1820 BGL Builder Name: ADAMS HOMES
Street: 5357 San Bendetto Place Permit Office:
City,State,Zip: Fort Pierce,FL,34951 Permit Number:
Owner: Jurisdiction: 661000
Design Location: FL,ST_LUCIE_CO_INTL County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2120.0 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1850 00 ft'
b.Frame-Wood,Adjacent R=13 0 270.00 ft'
3. Number of units,if multiple family 1 c. NIA R= ft'
4. Number of Bedrooms 4 d.NIA R= ft'
10.Ceiling Types (1820 0 sg(t.) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1820.00 ft'
6. Conditioned floor area above grade(ft') 1820 b.NIA R= ft'
Conditioned floor area below grade(42) 0 c.NIA R= ft'
11.Ducts R ft'
7. Windows(239.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH-Main 6 364
a. U-Factor: Dbl,U=0.33 168.74 W
SHGC: SHGC=0.23
b. U-Factor: ON,U=0.33 32.38 ft' 12.Cooling systems kBtulhr Efficiency
SHGC: SHGC=0.21 a.Central Unit 350 SEER:15.50
c. U-Factor: Dbl,U=0.33 20A2 W
SHGC: SHGC=0.31 13,Heating systems kBtufhr Efficiency
d. U-Factor: other(see details) 17.78 ft' a.Electric Heat Pump 34.6 HSPF:8.50
SHGC: other(see details)
Area Weighted Average Overhang Depth: 4.112 ft. 14,Hot water systems
Area Weighted Average SHGC: 0.269
8 Floor Types (1820.0 sgft.) Insulation Area a.Electric Cap:50 gallons
EF:0.940
a.Slab-On Grade Edge Insulation R=0.0 1820.00 W b. Conservation features
b. WA R- ft' None
c KA R= ft' 15.Credits Pstat
Glass/Floor Area: 0.131 Total Proposed Modified Loads: 62.66 PASS
Total Baseline Loads: 68,84
1 hereby certify that the plans and specifications covered by Review of the plans and itirill E STAp
this calculation are in complia y the Florid erj `� specifications covered by this bit
Code. calculation indicates compliance
With the Florida Energy Code. rru� ."-•. �j
PREPARED BY' Before construction is completed �
DATE: Winn Keornany this building will be inspected for 0 �.
compliance with Section 553.908 f
1 hereby certify that this buildiq, as si.es4as4,A in compliance Florida Statutes.
with the Florida Energy Code. CQD Wei
OWNER/AGENY UILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed In accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
3124/2020 11:33 AM EnergyGauge®USA 6.0.02(Rev 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Lot 15 Block 5 Waterstone 18 Bedrooms: 4 Address Type: Lot Information
Building Type: User Conditioned Area: 1820 Lot# 15
Owner Name: Total Stories: 1 Block/Subdivision: Waterstone
#of Units: 1 Worst Case: No PlatBook:
Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5357 San Bendetto Pla
Permit Office: Cross Ventilation- No County: St.Lucie
Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Fort Pierce,
Family Type: Single-family FL, 34951
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium
BLOCKS
Number Name Area Volume
1 Blockl 1820 18200
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 33 ft 0 1820 ft: 0.42 0 0.58
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pilch
# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Gable or Shed Composition shingles 2035 ft' 456 ft7 Medium N 0.85 N 0.85 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS iRCC
1 Full attic Vented 300 1820 ft' N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1820 ft' 0.11 Wood
3/24/2020 11:33 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
SpacerEraCtinnrea
Snr1 SW Exterior Concrete Block-Int Insul Main 41 59 0 10 0 590.0 ft' 0 0 0.6 0
2 SE Exterior Concrete B'ock-Int Insul Main 4.1 20 0 10 0 200.0 ft' 0 0 0.6 0
3 NE Exterior Concrete Block-Int Insul Main 4.1 66 0 10 0 660.0 ft' 0 0 0.6 0
4 NW Exterior Concrete Block-Int Insul Main 41 40 0 10 0 400.0 ft' 0 0.6 0
5 - Garage Frame Wood Main 13 27 0 10 0 270.0 ft' 0 0.23 0.01 0
DOORS
# Ornt Door Type Space Storms U Value Width Height Area
Ft In Ft In
1 SE Insulated Ma-n None .25 3 6 8 2002
2 - Wood Main None 25 2 8 6 8 17.8 ft'
WINDOWS
Orientation shown is the entered,Proposed orientation.
/ Wall Overhang
# Oml ID Frame Panes NFRC U-Factor SHGC Jmp Area Depth Separation Int Shade Screening
1 SW 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft' 1 ft 4 in 0 ft 10 in None Exterior 5
2 SW 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.601 1 ft 4 in 0 ft 10 in None Exterior 5
3 SE 2 Vinyl Low E Doub'e Yes 0.33 0.31 N 7 1 ft' 9 ft 0 in Oft 6 in None None
4 SE 2 Vinyl Low.E Double Yes 0.33 0.21 N 16.2 ft' 1 ft 4 in 1 ft 0 in None Exterior 5
5 SE 2 Vinyl Low-E Double Yes 033 0.21 N 16.2 ft' 1 ft 4 in 1 0 0 in None Exterior 5
6 SE 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft' 9 ft 0 in 2 ft 0 in None None
7 NE 3 Vinyl Low-E Double Yes 033 0.23 N 48.6 ft' 1 ft 4 in 0 ft 10 in None Exterior 5
8 NW 4 Vinyl Law-E Double Yes 0.55 0.7 N 17.8 ft' 11 ft 5 in 0 ft 6 in None Exterior 5
9 NW 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft' 1 ft 4 in 0 ft 10 in None Exterior 5
10 NW 4 Vinyl Low-E Double Yes 0.33 0.23 N 32A ft' 11 ft 6 in 0 ft 6 in None Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 396 ft' 396 ft' 64 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000445 2123.3 116.57 219.22 .1685 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBlulhr i sys#1
3/24/2020 11:33 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER:15.5 35 kBtulhr 1167 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ ---Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 364 ft' Main 91 W Default Leakage Main (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin Jan Feb [ Mar [ ]Apr [ ]May [X]Jun [X Jul [X Aug Se Oct Nov Dec
Heating H Jan f?C�Feb [X Mar []AApr [ ]Maay [ ]Jun [ ]Jul [ l Aug Sep Oct Nov Dec
Oct XNov HDec
Venting Jan [ ]Feb XMar [X] [ ] [ ]Jun [ Jul [ Aug Sep
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 fib 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 66 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 lbsls .ft. 0 ft' 0 ft 0.3 Main
3/24/2020 11:33 AM EnergyGauge&USA 6.0.02(Rev 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the Energy Performance Index,the more efficient the home.
1. New home or,addition 1. New(From Plans) 12. Ducts,location&insulation level
a)Supply ducts R 6.0
2.Single-family or multiple-family 2. Single-family b)Return ducts R 6.0
c)AHU location Main
3. No.of units(if multiple-family) 3. 1
4.Number of bedrooms 4. 4 13.Cooling system: Capacity 35.0
a)Split system SEER 15.5
5. Is this a worst case?(yes/no) 5. No b)Single package SEER
c)Ground/water source SEER/COP_
6. Conditioned floor area(sq.ft. 6. 1820 d) Room unit/PTAC EER
e)Other _
7. Windows,type and area
a) U-factor.(weighted average) 7a. 0.346
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.269 14. Heating system: Capacity 34.6
c)Area 7c. 239.3 a)Split system heat pump HSPF 8.5
b) Single package heat pump HSPF
8. Skylights c) Electric resistance COP
a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE_
b)Solar Heat Gain Coefficient(SHGC) 8b- NA e)Gas furnace,LPG AFUE
f)Other
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b}Wood, raised(R-value) 9b. 15.Water heating system
c)Concrete, raised(R-value) 9c. a) Electric resistance EF 0.94.
b) Gas fired, natural gas EF�_
10.Wal?type and insulation: c)Gas fired, LPG EF
A.Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e)Dedicated heat pump with tank EF
2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g) Other
1. Wood frame(Insulation R-value) 10B1. 13.0
2. Masonry(Insulation R-value) 1082.
16. HVAC credits claimed(Performance Method)
11. Ceiling type and insulation Level a)Ceiling fans
a)Under attic 11 a. 3o.0 b)Cross ventilation No
b)Single assembly 11b. c)Whole house fan No
c)Knee wallstskylight walls 11c. d) Multizone cooling credit
d)Radiant barrier installed 11d. No e)Multizone heating credit
f)Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT.
I certify that this home has complied with the Florida Building Code,Energy Conservation,through the above energy
saving features which will be installed(or exceeded)in this home before final inspection.Otherwise,a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: -- Date:
Address of New Horne: 5357 San Bendetto Place City/FL Zip: Fort Pierce, FL 34951
3.24F2ti120 11:34:00 AM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1