Loading...
HomeMy WebLinkAboutdesign pressure calcsIRA "Building Our Quality Reputation One Customer At A Time" SCC131150472 Property_Inforniation _� l Building Information_ Owner: BRUCE & THERESA KNIGHT Wind Zone: 170 MPH. Address: 13549 S INDIAN RIVER DR Exposure Category: C JENSEN BEACH, EL 34957 Minimum Building Dimension: 60 ft. Mean Roof Height: 12 ft. Risk Category: L___ Design Pressure Calculations Opening cation Device Device evice axPositive Max Negativeativeo Number Z Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) I Int 125 80 7 44.9 -48.1 2 Int 50 45 7 48.3 -51.5 3 Int 72 45 7 48.3 -51.5 4 End 50 45 7 48.3 -59.7 5 End 39 46 7 49.1 -61.4 6 Int 39 46 7 49.1 -52.3 7 Int 39 46 7 49.1 -52.3 8 Int -39 46 7 49.1 -52.3 9 Int 109 60 7 45.9 -49.1 10 End 34 48 7 49.3 -61.8 11 End 34 48 7 49.3 -61.8 12 End 108 81 7 45.2 -53.6 13 Int 72 35 7 48.3 51.5 14 End 109 45 7 46.6 -56.4 15 End 39 45 7 49.2 -61.5 16 Int 38 80 7 47.8 -51.0 17 Int 46 22 7 49.6 -52.8 18 End 50 45 7 48.2 -59.6 19 Int 72 45 7 47.7 -50.9 20 Int 50 45 7 48.2 -51.4 21 Int 50 46 7 48.2 -51.4 22 Int 72 46 7 47.6 -50.8 23 End 50 46 7 48.2 -59.5 24 End 39 46 7 49.1 -61.4 25 Int 25 46 7 49.6 52.8 Page 1 of 2 111�121111 1311!"1113 -MI -1 NINA f I� "Building Our Quality Reputation One Customer At A Time" SCC131150472 F- Property Information Building Information Owner: BRUCE & THERESA KNIGHT Wind Zone: 170 MPH. Address: 13549 S INDIAN RIVER DR Exposure Category: C JENSEN BEACH, FL 34957 Minimum Building Dimension: 60 ft. Zone Mean Roof Height: 12 ft. Pressure (psf) Risk Category: ji Prepared in acca dmrce mlth: dSCE 7-10, Chapler 30. Wh&Loads - Comiponenls and Cladding, &I Edition (1017) Florida Building Code. Page 2 of 2 Design Pressure Calculations I- g Opening Location Device Device Device Max Positive Max Negative g L-Ieight Number Zone Width (in) (in) Elevation (ft) Pressure (psf) Pressure (psi) 26 Int 39 46 7 49.1 -52.3 27 End 39 46 7 49.1 -61.4 28 End 50 46 7 48.2 -59.5 29 Int 72 46 7 47.6 -50.8 30 Int 50 46 7 48.2 -51.4 31 Int 23 22 7 49.6 -52.8 32 Int 46 21 7 49.6 -52.8 33 Lit 50 46 7 48.2 -51.4 34 Int 72 46 7 47.6 -50.8 35 End 50 46 7 48.2 -59.5 36 End 39 46 7 49.1 -61.4 37 Int 39 46 7 49.1 -52.3 38 Int 39 46 7 49.1 -52.3 39 End 39 46 7 49.1 -61.4 40 End 50 46 _ 7 48.2 -59.5 41 Int 72 46 7 48.2 -51.4 42 Int 50 46 7 48.2 -51.4 43 End 37 80 7 47.9 -58.9 Prepared in acca dmrce mlth: dSCE 7-10, Chapler 30. Wh&Loads - Comiponenls and Cladding, &I Edition (1017) Florida Building Code. Page 2 of 2